14-1091-004ELECTRICAL LOAD CALCULATION - TYPE EXISTING DESCRIPTION GENERALLOAD DESCRIPTION A. GENERAL LIGHTING LOAD MAIN BUS : 200 AMPS 5,727 VA B. (2) SMALL APPLIANCE BRANCH CIRCUIT @ 1,500 VA EACH SERVICE RESIDENCE EXISTING PANEL �!A" DAMPER RESISTANT ED NEUTRAL 9,600 VA 200 AMPS 1,200 VA DISHWASHER VOLTAGE 240/120 V 1.. - 3W. 200 VA WATER HEATER 4,800 VA MAINS 32,227 VA 200 AMPS 10,000 VA REMAINDER @ 40% (22,227 VA X.4) MOUNTING SURFACE 18,891 VA AIR CONDITIONING (OR HEATING) 7,680 VA TOTAL AIC CALCULATED LOAD FOR SERVICE 10,000 AMPS 26,571 VA / 240 V = 111 A (SERVICE RATING) AMPS POLES TOTAL COND WIRE REMARKS CKT. C. LAUNDRY 1,500 VA CKT. REMARKS WIRE COND TOTAL POLES AMPS 2. P - PROPOSED FIXTURE, AIR SUPPLY AND ELECTRICAL POINT AS REQUIRED V.A. SIZE+ 4. CEILING TO BE PATCHED & PAINTED AS REQUIRED TO MATCH EXISTING NO NO SIZE+ V.A. 20 1 1/2" 12 SINK OUTLET & DINING ROOM 1 2 STOVE 6 1" 9,600 2 50 20 1 1,200 1/2" 12 DISHWASHER 3A 20 1 * 1/2" 12 GARAGE LIGHT & OUTLET 313 4 20 1 SPACE 5A 20 1 1/2" 12 FRONT OUTSIDE OUTLET 5B 6 AIR HANDLER - AHU -1 6 1" 7,680 2 40 20 1 1,500 192'° 12 KITCHEN OUTLETS 7A 20 1 * 1/2" 12 BROWN BATHROOM 7B 8 20 1 1/2" 12 1 OUTSIDE LIGHT ISLAND 9A 20 1 * 1/2" 12 MASTER BATHROOM 913 10 DRYER 8 112" 5,000 2 40 15 1 1/2" 12 DINING ROOM 11 12 20 1 * 192" 12 DINING ROOM 13 14 WATER HEATER 8 1/2" 4,800 2 20 20 1 * 1/2" 12 MASTER BED & PATIO WALL 15 16 20 2 4,800 1/2" 10 AIR COMPRESSOR 17 18 WASHER 12 1/2" 1,500 1 20 20A MASTER BEDROOM 12 1/2" 1 15 19 20B FRONT BEDROOM 12 1/2" * 1 15 22A GARAGE DOOR 12 1/2" * 1 20 15 1 1,200 1/2" 12 MICROWAVE 21 22B MIDDLE BEDROOM 12 1/2" 1 20 15 1 * 1/2" 12 GARAGE SWITCH 23 24 LIVING ROOM / FAM ROOM 12 1/2" 1 15 15 1 1,200 112" 12 REFRIGERATOR 25 26 GARAGE LIGHTS 12 1/2" 1 15 15 1 * 1/2" 12 OUTSIDE CHEEKEE OUTLETS 27 28 KIT LIGHTS & OUTSIDE REC. 12 1/2" 1 15 20 1 - 1/2" 12 CHEEKEE GFCI RECEPT. 29A 30 GARAGE DOOR 12 1/2" 200 1 20 20 1 1/2" 12 SMOKE DETECTORS 29B ` - SEE GENERAL LIGHTING LOAD CALCULATION FEEDER 3 -2/0 THWN IN 2" CONDUIT, (VIF) FED FROM : EXISTING SERVICE ELECTRICAL LOAD CALCULATION - LEGEND EXISTING PANEL A DESCRIPTION GENERALLOAD DESCRIPTION A. GENERAL LIGHTING LOAD RECESSED MOUNTED LIGHT 1,909 SF x 3VA = 5,727 VA B. (2) SMALL APPLIANCE BRANCH CIRCUIT @ 1,500 VA EACH 3,000 VA C. LAUNDRY BRANCH CIRCUIT 1,500 VA D. FASTENED IN PLACE APPLIANCES DAMPER RESISTANT ED RANGE 9,600 VA MICROWAVE 1,200 VA DISHWASHER 1,200 VA DRYER 5,000 VA GARAGE DOOR OPENER 200 VA WATER HEATER 4,800 VA TOTAL GENERAL LOAD 32,227 VA FIRST 10 KVA 9100% 10,000 VA REMAINDER @ 40% (22,227 VA X.4) 8,891 VA SUBTOTAL GENERAL LOAD 18,891 VA AIR CONDITIONING (OR HEATING) 7,680 VA TOTAL 26,571 VA CALCULATED LOAD FOR SERVICE 15A OR 20A 26,571 VA / 240 V = 111 A (SERVICE RATING) INTERRUPTER RECEPTACLE. LISTED FEEDER NEUTRAL LOAD, PER NEC 220.61 LISTED TAMPER RESISTANT A. GENERAL LIGHTING LOAD 5,727 VA B. SMALL APPLIANCE 3,000 VA C. LAUNDRY 1,500 VA 3,000 VA @ 100% 7,227 VA @ 35% i � 1 liwills-, "M i. �.. •- V_ � •r DISHWASHER TOTAL CALCULATED LOAD FOR NEUTRAL 18,000 VA / 240 V = 75 A 10,227 VA 3,000 VA 2,530 VA 5,530 VA 5,530 VA 6,720 VA 4,550 VA 1,200 VA 18,000 VA NOTE: SMOKE DETECTOR SHALL NOT BE CLOSER THAN 3' FROM AIR REGISTER & BATH DOOR AND 20' FROM COOKING APPLIANCES. NOTE: PROVIDE SMOKE DETECTOR & MONOXIDE OF CARBON COMBO SYSTEM TO BE INSTALLED IN ACCORDANCE W/ NFPA 72/99. NOTE: ALL NEW CIRCUITS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER NOTE: PROVIDE TAMPER PROOF FOR ALL NEW RECEPTACLES, AS PER 406.11 N.E.C. EXISTING OVERHEAD SERVICE ENTRANCE - (2) (3) 2/0 THWN IN 3 -2/0 THWN IN 2" 2" CONDUIT CONDUIT, (V.I.F.) EXIST. EXIST. 200 ELECTRIC AMP PANEL "! METER & MAIN DISC. `-1 #4 THWN IN 1/2" COND. (V.I.F.) (2) 5/8" 0 x 10' -0" L. COPPER CLAD GROUNDING ROD. CONNECT TO 3/4" WATER PIPE (V.I.F.) ELECTRICAL RISER ELECTRICAL NOTES 1. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ACCORDANCE WITH THESE DRAWINGS 2. COMPLY WITH THE 2008 N.E.C. AND THE FLORIDA BUILDING CODE 2010. 3. PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM. 4. CONTRACTOR SHALL OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT. 5. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY OTHER TRADES. 6. NO APPLIANCES OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEVATION 7. COORDINATE ALL OUTLET LOCATIONS WITH BUILDING ARCHITECTURAL FEATURES. 8. CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. 9. A/C COMPRESSOR SHALL BE INSTALLED ABOVE BASE FLOOD ELEVATION 10. OUTDOOR CONDUITS SHALL BE SCHEDULE 40 PVC.MINIMUM COVER SHALL BE 24 11. ALL MOUNTING HARDWARE SHALL BE BY CONTRACTOR. 12. ELECTRICAL OUTLETS BELOW BASE ELEVATION SHALL BE INSTALLED AT THE HIGHEST PERMITTED ELEVATION AND SHALL BE INSTALLED (SEPARATE) AS INDEPENDENT CIRCUITS FROM THOSE IN THE HABITABLE AREAS, 13. MAIN CIRCUIT BREAKER PANELS SHALL BE LOCATED ABOVE BASE FLOOD ELEVATION 14. CONTRACTOR SHALL CONFIRM ELECTRICAL METER LOCATION AND COMPLIANCE WITH F.E.M.A. REQUIREMENTS WITH F.P.L. 15. ALL RECEPTACLES AND SWITCHES WILL BE MODEL DECORA AS MANUFACTURED BY LEVITON. 16. ELECTRICAL CONTRACTOR TO MAINTAIN JOB SITE CLEAN SMOKE DETECTOR NOTE: 1. SMOKE DETECTOR SYSTEM TO BE INSTALLED IN ACCORDANCE W /NFPA 72/99 2. SMOKE DETECTOR SHALL BE NOT BE CLOSER THAN 3' FROM AIR REGISTER & BATH DOOR AND 20' FROM COOKING APPLIANCES SCALE: 1/4"= l'-O" STING :CTRICAL 4EL "A" EXISTING ELECTRICAL METER CEILING LEGEND SYMBOL DESCRIPTION SYMBOL DESCRIPTION O RECESSED MOUNTED LIGHT �0 WALL MOUNTED LIGHT FIXTURE FIXTURE DAMPER RESISTANT ED CEILING MOUNTED LIGHT FIXTURE MOUNTED LIGHT FIXTURE AMILCAR R. ME LEN FLORIDA REGISTRATION AR93063 CEILING MOUNTED HARDWIRED EF EXHAUST FAN FIXTURE ® COMBINATION CARBON MONOXIDE & SMOKE ALARM. SEE NOTE 1 TV /CABLE CONNECTION $ LIGHT SWITCH GFCI 15A OR 20A GROUND -FAULT CIRCUIT 15A OR 20A INTERRUPTER RECEPTACLE. LISTED LISTED TAMPER RESISTANT TAMPER RESISTANT PER 2008 NEC PER 2008 NEC 406.11 406.11. NOTES: 1. SMOKE ALARM. ALARM DEVICES SHALL BE INTERCONNECTED IN SUCH A MANNER THAT THE ACTUATION ON ONE ALARM WILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL DWELLING UNIT 2. P - PROPOSED FIXTURE, AIR SUPPLY AND ELECTRICAL POINT AS REQUIRED 3. ER - EXISTING FIXTURE TO REMAIN 4. CEILING TO BE PATCHED & PAINTED AS REQUIRED TO MATCH EXISTING le architect PA 1001 SW 67 AVE, STE 102, Miami, FL 33144 TEL.: +1 305 894 6605 FAX.: +1 786 347 7692 INFO @ARM- ARCHITECT.COM DE CARDENAS RESIDENCE project name. project address. A .. , drawn by. ARM project no. 14052 E�1 "� date. 08.212014 drawing no. AIIIIIIIIIIIIIIII 0 2014 ARM ARCHITECT, P.A. AMILCAR R. ME LEN FLORIDA REGISTRATION AR93063 le architect PA 1001 SW 67 AVE, STE 102, Miami, FL 33144 TEL.: +1 305 894 6605 FAX.: +1 786 347 7692 INFO @ARM- ARCHITECT.COM DE CARDENAS RESIDENCE project name. project address. A .. , drawn by. ARM project no. 14052 E�1 "� date. 08.212014 drawing no. AIIIIIIIIIIIIIIII 0 2014 ARM ARCHITECT, P.A.