14-1091-002[�® _I I EXISTING WALL TO REMAIN w� I REMOVE EXISTING STUD/ GYPSUM BOARD WALL KEYNOTES E 01 EXISTING PARTITION WALL TO BE REMOVED AS REQUIRED FOR PROPOSED LAYOUT. SEE GENERAL REMOVAL NOTES 02 EXISTING DOOR TO BE REMOVED. SEE GENERAL REMOVAL NOTES 03 EXISTING PLUMBING FIXTURES TO BE REMOVED. PLUMBING SYSTEM TO BE RELOCATED, SEE GENERAL REMOVAL NOTES EXISTING LIGHTING FIXTURES IN EXISTING MASTER BATHROOM AND MASTER CLOSET 04 TO BE REPLACED. REFER TO ELECTRICAL SHEETS FOR PROPOSED LAYOUT. SEE REMOVAL NOTES. ki • • 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LABOR, EQUIPMENT AND SERVICES REQUIRED TO PROPERLY EXECUTE THE DEMOLITION AND REMOVAL WORK INDICATED ON THESE CONSTRUCTION DOCUMENTS. 2. THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE EXISTING BUILDING AND VERIFY THAT ALL ITEMS INDICATED TO BE EXISTING ARE IN PLACE AND SHOWN ACCURATELY. 3. ALL DEMOLITION WORK SHALL BE PERFORMED BY CAUSING THE LEAST POSSIBLE DAMAGE TO THE EXISTING WORK TO REMAIN. 4. PROVISIONS SHALL BE MADE TO MINIMIZE THE SPREAD OF DEBRIS AND DUST TO ADJACENT PROPERTIES. SITE SHALL BE MAINTAINED AS CLEAN AS POSSIBLE AT ALL TIMES. 5. CONTRACTOR SHALL IDENTIFY ANY HAZARDOUS MATERIALS TO BE REMOVED, SUCH AS ASBESTOS, PRIOR TO THE BEGINNING OF DEMOLITION. HAZARDOUS MATERIALS SHALL BE REMOVED IN ACCORDANCE WITH LOCAL, STATE, OR FEDERAL CODES AND REGULATIONS 6. ALL DEBRIS AND MATERIALS DEMOLISHED OR REMOVED FROM THE BUILDING SHALL BE DISPOSED OF IN ACCORDANCE WITH LOCAL, STATE, OR FEDERAL REGULATIONS. T EXISTING WORK TO REMAIN WHICH HAS BEEN DAMAGED OR DISTURBED AS A RESULT OF THE DEMOLITION PROCESS SHALL BE RESTORED TO "LIKE NEW" CONDITION. ALL EXISTING SURFACES AND FINISHES REQUIRED TO MATCH AND ALIGN WITH NEW CONSTRUCTION SHALL BE REPLACED IF DAMAGED OR ALTERED. 8. DO NOT REMOVE ANY EXISTING STRUCTURAL MEMBERS BEFORE SHORING AND BRACING AS REQUIRED. CONTACT ARCHITECT WITH ANY QUESTIONS OR CONCERNS REGARDING UNCLEAR INFORMATION ABOUT THE REMOVAL OF ANY STRUCTURAL MEMBER. 9. WHERE ELECTRICAL WORK NEEDS TO BE ABANDONED, REMOVE WIRE BACK TO THE ELECTRICAL PANEL. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. 10. WHERE PLUMBING PIPING NEEDS TO BE ABANDONED REMOVE PIPING WHERE IT CAN BE CAPPED. WHERE PLUMBING VENTS NEED TO BE ABANDONED, REMOVE ENTIRELY. PATCH AND REPAIR ROOF PENETRATIONS. ALL PLUMBING DEMOLITION SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR. 11. CONTACT GAS UTILITY COMPANY IF GAS LINES ARE REQUIRED TO BE REMOVED OR ABANDONED. SCALE: 1/4"= 1 ° -0" 3-1, AMILCAR R.41)[END •$.'`° FLORIDA REGISTRATION AR93063 project address. drawing title. drawn by. project no. date. • i I IN 1 1 08.21.2014 1 drawing no. 2014 ARM ARCHITECT, P.A.