14-1091-002[�® _I I EXISTING WALL TO REMAIN
w� I REMOVE EXISTING STUD/
GYPSUM BOARD WALL
KEYNOTES
E 01
EXISTING PARTITION WALL TO BE REMOVED AS REQUIRED FOR PROPOSED LAYOUT.
SEE GENERAL REMOVAL NOTES
02
EXISTING DOOR TO BE REMOVED. SEE GENERAL REMOVAL NOTES
03
EXISTING PLUMBING FIXTURES TO BE REMOVED. PLUMBING SYSTEM TO BE
RELOCATED, SEE GENERAL REMOVAL NOTES
EXISTING LIGHTING FIXTURES IN EXISTING MASTER BATHROOM AND MASTER CLOSET
04
TO BE REPLACED. REFER TO ELECTRICAL SHEETS FOR PROPOSED LAYOUT. SEE
REMOVAL NOTES.
ki
• •
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL LABOR,
EQUIPMENT AND SERVICES REQUIRED TO PROPERLY EXECUTE THE
DEMOLITION AND REMOVAL WORK INDICATED ON THESE CONSTRUCTION
DOCUMENTS.
2. THE CONTRACTOR SHALL VISIT THE SITE AND INSPECT THE EXISTING
BUILDING AND VERIFY THAT ALL ITEMS INDICATED TO BE EXISTING ARE IN
PLACE AND SHOWN ACCURATELY.
3. ALL DEMOLITION WORK SHALL BE PERFORMED BY CAUSING THE LEAST
POSSIBLE DAMAGE TO THE EXISTING WORK TO REMAIN.
4. PROVISIONS SHALL BE MADE TO MINIMIZE THE SPREAD OF DEBRIS AND
DUST TO ADJACENT PROPERTIES. SITE SHALL BE MAINTAINED AS CLEAN AS
POSSIBLE AT ALL TIMES.
5. CONTRACTOR SHALL IDENTIFY ANY HAZARDOUS MATERIALS TO BE
REMOVED, SUCH AS ASBESTOS, PRIOR TO THE BEGINNING OF DEMOLITION.
HAZARDOUS MATERIALS SHALL BE REMOVED IN ACCORDANCE WITH LOCAL,
STATE, OR FEDERAL CODES AND REGULATIONS
6. ALL DEBRIS AND MATERIALS DEMOLISHED OR REMOVED FROM THE
BUILDING SHALL BE DISPOSED OF IN ACCORDANCE WITH LOCAL, STATE, OR
FEDERAL REGULATIONS.
T EXISTING WORK TO REMAIN WHICH HAS BEEN DAMAGED OR DISTURBED AS
A RESULT OF THE DEMOLITION PROCESS SHALL BE RESTORED TO "LIKE
NEW" CONDITION. ALL EXISTING SURFACES AND FINISHES REQUIRED TO
MATCH AND ALIGN WITH NEW CONSTRUCTION SHALL BE REPLACED IF
DAMAGED OR ALTERED.
8. DO NOT REMOVE ANY EXISTING STRUCTURAL MEMBERS BEFORE SHORING
AND BRACING AS REQUIRED. CONTACT ARCHITECT WITH ANY QUESTIONS
OR CONCERNS REGARDING UNCLEAR INFORMATION ABOUT THE REMOVAL
OF ANY STRUCTURAL MEMBER.
9. WHERE ELECTRICAL WORK NEEDS TO BE ABANDONED, REMOVE WIRE BACK
TO THE ELECTRICAL PANEL. ALL ELECTRICAL WORK SHALL BE PERFORMED
BY A LICENSED ELECTRICAL CONTRACTOR.
10. WHERE PLUMBING PIPING NEEDS TO BE ABANDONED REMOVE PIPING
WHERE IT CAN BE CAPPED. WHERE PLUMBING VENTS NEED TO BE
ABANDONED, REMOVE ENTIRELY. PATCH AND REPAIR ROOF PENETRATIONS.
ALL PLUMBING DEMOLITION SHALL BE PERFORMED BY A LICENSED
PLUMBING CONTRACTOR.
11. CONTACT GAS UTILITY COMPANY IF GAS LINES ARE REQUIRED TO BE
REMOVED OR ABANDONED.
SCALE: 1/4"= 1 ° -0"
3-1,
AMILCAR R.41)[END •$.'`°
FLORIDA REGISTRATION AR93063
project address.
drawing title.
drawn by.
project no.
date.
• i
I IN
1 1
08.21.2014 1 drawing no.
2014 ARM ARCHITECT, P.A.