13-1329R-003CL: -J -J OIL T.O. PILE CAP PROPERTY CORNER AND 4 LIMITS OF CONSTRUCTION DIMENSION MAY VARY, = 2' CONFIRM w/ SURVEYOR API A - _ F-i. 6" CIP CONC. STAIR W/ #5 12PC; 0 12 "o.c. E.W. BOTT. TYP. I MF40.24 C -2 B - CANTI EVERED BEAM. 4 5 5.1 5.6.1 SEE S CTION 12/j 2 /S4.03 0 2' -1j" 24' -111" 0 M NOTE 16 AT GENERATOR WITH 2 CANT.- CW -1 SLAB CANTILEVERED 1 a �r C TOWER CRANE - FOUNDATION SEE S3.22 0 I i I 1 2 3 4 5 5.1 5.6.1 o.c. 25' -2" - 20' -0" 29' -0" 12' -8" T -11 9' -11" 3' -51 "I 2' -1j" 24' -111" INTEGRAL WITH NOTE 16 AT GENERATOR WITH 2 EL: -5' -5' T.O. PILE CAE' ,. , CW -1 0 CANTILEVERED 1 a INDICATES #5 TOP BARS 6" CONCRETE W/ #5 ® 6" o.c. EACH WAY (U.N.O.). POST - TENSION 4 I ' 4 IM. T NSIONED FUEL TANK ` ._. C -2 T 0 LANDIN C -2 SPCS ;..a I -,. C -2 5PCS I, . s4.oa C -2 C -2 s4.oz I III C -2 s4.oz 2A I 0" -0" SLABo ., -.; .,_.,� r, RW -4 RW -4 - CW -1- - - CW -1 - RW 1 +CW -1 O GB -1 Ism'; `- GB -1 -I-� GB -2 - - L - � I I ` EL. td -o" 174.051 I Il 1.00 I I, s( EL =5 -5 III I I I I I I I I I r PROVIDE 8 "x16 "W /2#6 ;T B T.O. SLAB T.O. PILE CAP I I W/ #3 C� 7 o.c. RAKED I 01 m BEAM IN CMU WALL TO L - - � L- 7-IT - 3 SUPPORT EDGE` 0 'STAIR �r EDGE OF POST- Ui I ! cn o I to `r'r- I I� 3 I m TENSIONED SLAB �` I oo 14 ° I I`_ EL. -3.4 I I I w ; r` I� ,T.O. ,SLAB �., 7f 7 e , C -4 C -4 ,z s u s M-1 Im CANTILEVERED POST - TENSIONED -2 " 6PC I I 1e I I i Z'I I 1 3 1` C 4 PC SLAB AT INTERMEDIATE LANDING T.O. PILE CAP ABOVE. EDGE LOADING FROM may_ I `STAIR ON PT CANT. SLAB ISM I DL -10 KIPS�_LL�5.KIPS - -1 RW -5 1 0 `"1 1 4.00 � I I I I I I I - - CW CW -1 r I r - - - �- T rf 00 -4 GB -2 GB 4 L - - - - - J T.O. PILE CAP I aol cDl j _ I (STEPPED GRADE BEAM, ' II C -4 I _o..,�'`' - - - -:, -, I SEE S3.05 AND 6/54.03) _._... ° T23 0 ^ 0 5 I OPE UP 16" CONC. HYDROSTATIC SLAB W/ 5 7B 54.0 I o s; -o _ #7 0 8 " or #6 0 " O.C. E.W. T &B Q 04.03 w/ 5 FEET OF WA R HEAD ABOVE -1 I _..____, DOWN �•UI m` \ <-`> _ HYDROSTATIC SLA UNTIL BUILDING SLOP \ / �o SHELL (FLOOR COLUMNS & WALLS) w II } IS CONSTRUCTED UP TO THE 5TH �-# I LEVEL SLAB ( 8" POST -TE of W NS ONED -` j> ....' ( I SLAB f'c 5000 PSI ` I ( 1PCS 5 CONC SLAB -ON -GRADE / \ < m ( w/ 6x6, W2.9 x W2.9 WWF SUPPORTING ` 'o I HYDROSTATIC ON 10 MIL VAPOR BARRIER 1 -•� " _ .:.- ::: -1,a >;, 1 s4. I SLAB, TYP ON (COMPACTED, TREATED II C- SUB -SOIL (TYPICAL) ( C -3 C C -1 - =- -- -2 5P - , 4.00 1.00 17 f - c -9. L J - 03 -�A EL - 5' -5" I SR -50 i s4.oz L- - J T O ;PILE CAP T -1� 8" CIP CONC WALL W/ #5 EDGE OF POST- w !`��- ® 7 "o.c. E.F. `VERY. & 5 TENSIONED SLAB Lq I I # I , I F @ 16 "o:c. E F HORIZ. C -2 C -2 / 3 0V v v I C -2 I - , C -2 0 \,�; ,; 1.00 / / / \ \ / / \ \ / / \ \ / / \ \ / / \ \ / / \ \/ / / \\ 4.00 CW 1 CW -1 TC -1 CW -1 4 00 C.1 j. AMS I A DENOTES #5 0 12" TOP & BOTTOM Q 16) PROVIDE L6x4x1 /2 "x12" LG GALVANIZED STEEL ANGLES ® EA. ENDS & MIDPOINTS OF INTERIOR GENERATOR /FUEL DIRECTION THROUGH SUPPORT COLUMNS (PER ACI 18.12.4) y: o.c. 0 - 8 INDICATES #4 HAIRPIN �' f I INTEGRAL WITH INI - CW -1 i R CW -1 CW -1 0 CANTILEVERED 1 a INDICATES #5 TOP BARS 6" CONCRETE W/ #5 ® 6" o.c. EACH WAY (U.N.O.). POST - TENSION RETAINING 1.00 }.' 15) , ALL, PARAPET ..WALLS.,9RE­ MW-4 -TYPICAL ,U:N.O: A ... -d T NSIONED o 11120113 I 10) I WALL BELOW 2A I SOAR INTERMEDIATE o r _ ,1 8 POST- TENSIONED GL SHOWN OTHERWISE. 2B s4.oz SLOPE UP LANDING ABOVE. _I 3 `SLAB f'c= 5000 PSI ►� I 8" POST - TENSIONED >f {° f EDGE LOADING `° FROM STAIR ON PT 5 �c�i - CANT.----._ I,�}�- -cal C -2 / C -1 -C-1 / C -1 SF 1 f ° CANT. SLAB IS - f'c= 5000 PSI ". 7 G DL =6.5 KIPS, LL =3.5 KIPS I 1203 7A 00 SLAB 7.00 ' ' J I } I o0 I 04,03 i-•. 04.03 1 O_ I I SLAB AT INTERMEDIATE LANDING NMI" j ^ S4.02 -- O w \ 3.00 ABOVE. EDGE LOADING FROM x . o ° LJ - / -j � - i - EDGE OF ICI_ _ II N STAIR ON PT CANT. SLAB IS F POST-TENSION I'D ' SLAB AT EDGE OF � IOC _ 1 i DL =10 KIPS, LL=5 KIPS I I STAIR LANDING Y 7q - ' f SEE SECTION I I I #6 TOP w/ 6" C -9 s4.o3 I I I } HOOK f;h 6" I 12/04.03 & B AMS I A DENOTES #5 0 12" TOP & BOTTOM Q 16) PROVIDE L6x4x1 /2 "x12" LG GALVANIZED STEEL ANGLES ® EA. ENDS & MIDPOINTS OF INTERIOR GENERATOR /FUEL DIRECTION THROUGH SUPPORT COLUMNS (PER ACI 18.12.4) y: o.c. 0 1 MASONRY WALLS ARE NOT TO' BE COMPLETED UNTIL 8 INDICATES #4 HAIRPIN 9) " STAIRS SHALL BE 6" CONCRETE W/ #5 ®6 o.c. LONGIT. INTEGRAL WITH INI - r- g I E�. 4' -tT.LO'FS�LAB 0 THE FLOOR ABOVE HAS BEEN POURED, CABLES r- INDICATES #5 TOP BARS INDICATES #5 TOP BARS 6" CONCRETE W/ #5 ® 6" o.c. EACH WAY (U.N.O.). POST - TENSION D - - - INDICATES #5 BOTTOM BARS 15) , ALL, PARAPET ..WALLS.,9RE­ MW-4 -TYPICAL ,U:N.O: A ... -d 10118113 o 11120113 INDICATES #5 TOP BARS ® 12 "o.c. (6' LONG W/ 10" HOOK) 10) GENERAL CONTRACTOR TO PROVIDE 3/4" RECESS FOR CANTILEVERED LAB I�� _ - I _ GL SHOWN OTHERWISE. T -2 INDICATES #5 TOP BARS ®12 "o.c. (10° LONG) SLOPE UP _ IV - � I 8" POST - TENSIONED SLOPE DOWN R " TENSIONED $ POST 5 o - CANT.----._ I,�}�- -cal I SLAB f c= 5000 PSI - f'c= 5000 PSI SLAB r° BEAM I I CANTILEVERED POST- TENSIONED SLAB AT INTERMEDIATE LANDING S4.02 ABOVE. EDGE LOADING FROM ICI_ _ II STAIR ON PT CANT. SLAB IS IOC _ i DL =10 KIPS, LL=5 KIPS Y 7q 04.03 C -9 s4.o3 7 16' -7" CIP 1 CONCRE 4" CONC SLAB-ON-GRADE Ell A$ ;• • rrar r ir••Imm•Imms•IIIr: - nr••►.•- �..• .;r � ��rrrn►, � -; !ON 10 MIL VAPOR i��.�! COMPACTED, TREATED i _ C M 6.00 .........r11 W, • 1 OF POST- OF CONC. N POISON -AF - - - _ - - - - �, - T.E. - - - I I i �q- INDICATES STEP IN FND /GRADE BEAM T.O. SL B :. SW -3 I I ® INDICATES CMU WALLS (SEE SCHEDULE). J Q INDICATES CONCRETE WALL (SEE SCHEDULE). T -1 I �` I INDICATES CONCRETE COLUMN (SEE SCHEDULE) / f + lk I ( C.J. INDICATES SAW CUT VERTICAL JOINTS ® 12 "o.c. E.W. MAX. CID En I' ICI T.E. INDICATES 8 "x16" THICKENED EDGE W/ 2 #5 x CONT. TYP. 8 " POST- SIONED - I I 1 CW -1 INDICATES 8" CONCRETE CRASH WALL W/ #4 ® 6 "o.c. E.F. SLAB f'c= f 000 PSI :, ,, . C I VERTICAL AND #4 ® 12 o.c. E.F. HORIZONTAL. RW- INDICATES CONCRETE RETAINING WALL _ f -_ .. INDICATES 14 "0 AUGERCAST PILE INDICATES 14 "0 AUGERCAST TENSION PILE 8" C NCRETE WALL kTYP) C -3 I C -7 I I I I I INDICATES (2) #4 x 5' -0" LONG RE- ENTRANT BARS TYP. C -31 3PC { TC -1 I C -5 8 ,� // r 2PC ( 3PC I I INDICATES 1PCS. L J GB -3 sR -15 FOUNDATION NOTES: • 1. FOR COLUMN SIZES AND REINFORCING REQUIREMENTS REFER TO SCHEDULE ON S3.21. 2. TOP OF PILE CAPS SHALL BE -2' -6" U.N.O. TOP OF IPL =TOP Fe =324K Fe =324K 1• EL. t0' n ff -• o • . 1 ••• 4 I I HYDROSTATIC SLAB 3. FOR PILE CAP DETAILS REFER TO SHEET S3.22. 4. BRACE RETAINING WALLS DURING CONSTRUCTION. II 5. COORDINATE THIS PLAN WITH CIVIL SITE PLAN. FUTURE TNANT I 6. ALL CMU TO BE MW -1 UNLESS NOTED OTHERWISE. SLAB -ON -GRADE wI{ 7. ALL GRADE BEAMS ARE CENTERED UNDER WALLS /PILE CAPS N.I.C. ~Id IIII UNLESS NOTED OTHERWISE. (I 3 I I 8. PROVIDE • 2 #4 x 6'-0" TOP IN CONCRETE SLAB AT CORNERS MW -7 1,- I ►I OF CMU TYPICAL. ' 1 9. PROVIDE HSS 6x4x1 /2 GALV. MINIMUM 14'- 0 "o.c. MAX (HORIZONTALLY AND VERTICALLY) AT STOREFRONT AND / I s4.oa CURTAIN WALL SYSTEMS. COORDINATE STRUCTURAL HSS 1 MEMBERS WITH ARCHITECTURAL AND SUBMIT SIGNED AND SEALED CALCULATIONS AND SHOP DRAWINGS FOR THE C_1 I C -3 i 4PC I _ 1 STOREFRONT AND CURTAIN WALL SYSTEMS INCLUDING ALL _... SR__3 I 1 y 2PC1 I ( 3PC CONNECTIONS TO CONCRETE SLABS /WALLS /COLUMNS. �6 � i � a FIRE RATING REQUIREMENTS PER ARCH'L ANALYSIS: 1. BEARING WALLS = 2HRS 2. FLOOR CONSTRUCTION = 2HRS. 3. COLUMNS & BEAMS = 2 HRS 4. DOOR CONSTRUCTION = 1 HRS 5. TENANT SEPARATION = 1 HRS. I I i Ij I I NOTE 1 I I I ( CONCRETE WALLS CW -1 ARE NOT TO BE C -3 C -7I'I I I COMPLETED UNTIL THE FLOOR ABOVE HAS C -2 C -3 I EXTENDED---_ I SR -12 MW -1 ~ ` C -4 C -4 C -4 C -3 / I I 4PC I I BEEN POURED, CABLES TENSIONED AND FLOOR I I I 00I SLAB pr. INDICATES TURN 7.00 -2 I 7.00 ( SR -2 �'.r 700 0 T7 ( e��51� I , �I) 2PC I I 3PC L SHORES AND RESHORES REMOVED. DOWN BEAM ` g oo _ ( lO SR -26 6 -MW -7 v 6 �� r q- - Fe =351K SEE SECTION Q _ o o S 2 ° 7.00 , �.__..__.�_- . I - .: x - - E^ 8 _ 'l 1 4.00 I, I I I - - -- _ 1.00 - f ,- _ L. f lot 3.00 6 r 00 SW - -_ GB-3 I %`` I I J I / oo - I -2 • i I I 11 I DO i W 12 II = MF40.24 s4. _ rn - CW 1 : , ,: I i �j I , f NOTE 16 3 MW -1 r ( m m II E � AT FUEL =' � p 3 , T 1 ` 6" CIP CONC. STAIR T -1 B -1 -� 'TANK 2, L W/ #5 C� 12"c. c. ,' / ,% I I T -1 I a E.W. BOTT. r I TI I �' �, I ,'. I I I, I I III I ;,o-1 S( C -6 `°I - - -- - - -- - -- I 'I 2 B 1 I J' J m N s I 6 PC ill 1 I r f� , Fe =351 K -4.0-01 1 I Uj o _ r � I I I SR -26 SR -26 7.00 i it F .. -- - - -- 7 400 . ' - - -- -- - -J r I , -. w.., - [ T�. N CW -1 CW -1 CW -1 2.00 CW 1 1.00 FR MW -2 M47 MW -6 o .� P CONC. STAIR 8" CIP CONCRETE STAIRS Si e� 4A 4 I I 1 MW -6 c C -10 , I F' I C -2 q" k F _... I' C -2 I C -2 C -2 s4.o ` I W/ #5 0 12 "o.c.A I TYP. s ±.oa W/ #5 ®8 o.c. E.W. s4o i I I o I - I BOTT. TYPI. I I t .0 -�l -- - L_ I A E.W. BOTT. TYP. v r r�r�mnvv rvv r rte. A DENOTES #5 0 12" TOP & BOTTOM Q 16) PROVIDE L6x4x1 /2 "x12" LG GALVANIZED STEEL ANGLES ® EA. ENDS & MIDPOINTS OF INTERIOR GENERATOR /FUEL DIRECTION THROUGH SUPPORT COLUMNS (PER ACI 18.12.4) y: to 0 1 MASONRY WALLS ARE NOT TO' BE COMPLETED UNTIL 8 INDICATES #4 HAIRPIN 9) " STAIRS SHALL BE 6" CONCRETE W/ #5 ®6 o.c. LONGIT. SR -# INDICATES STUD RAIL SHEAR REINFORCING. SYSTEM. THERE IS A TOTAL OF 3 ANGLES PER LONG SIDE & 2 PER SHORT SIDE, & 10 ANGLES TOTAL. FASTEN' E.F. VERTICAL AND #4 012 "o.c. E.F. HORIZONTAL r- g GROUT FILLED CELL AT EVERY CORNER, BOTH EDGES OF EVERY OPENING AND AS AND #4 ® 12" o.c. TRANSV. BOTT. LANDINGS SHALL BE 0 THE FLOOR ABOVE HAS BEEN POURED, CABLES r- INDICATES #5 TOP BARS INDICATES #5 TOP BARS 6" CONCRETE W/ #5 ® 6" o.c. EACH WAY (U.N.O.). o > TENSIONED AND ALL SHORES AND RESHORES REMOVED. - - - INDICATES #5 BOTTOM BARS 15) , ALL, PARAPET ..WALLS.,9RE­ MW-4 -TYPICAL ,U:N.O: A ... -d 10118113 Revision Prooress Set 11120113 INDICATES #5 TOP BARS ® 12 "o.c. (6' LONG W/ 10" HOOK) 10) GENERAL CONTRACTOR TO PROVIDE 3/4" RECESS FOR v' 2) EXTERIOR MASONRY WALLS ARE TYPE (MW -2) UNLESS MASONRY WALLS AT ALL SLAB EDGES OR STEPS (TYP.). GL SHOWN OTHERWISE. T -2 INDICATES #5 TOP BARS ®12 "o.c. (10° LONG) _ 11) FOR EXTERIOR WALL SEGMENTS 8" LONG OR LESS R - 5 : iii ?f�',•�?xCiiG'3:iL4{,i�`?i,�.� ., i i:,IC���+et:i£ ,:►4� �3'Ib�l'�5�•:,L- �rr•�x. ���sl� �'t�£��brr ` ��C�rr1'��H�::k'.ti�i��'.m,} �f�'������;�.�a°�l° o OTHERWISE. A DENOTES #5 0 12" TOP & BOTTOM Q 16) PROVIDE L6x4x1 /2 "x12" LG GALVANIZED STEEL ANGLES ® EA. ENDS & MIDPOINTS OF INTERIOR GENERATOR /FUEL DIRECTION THROUGH SUPPORT COLUMNS (PER ACI 18.12.4) y: to ° WALLS AND INTERIOR COLUMNS AND SHE ARWALLS T -4 INDICATES 2 4 DIAGONAL TOP & BOTTOM. 5' LONG (} # ( ) 12) CW -, INDICATES 8" CONCRETE CRASH WALL W / #4 @6 "o.c. o 4 ALL MASONRY WALLS TO HAVE A REINFORCED, SR -# INDICATES STUD RAIL SHEAR REINFORCING. SYSTEM. THERE IS A TOTAL OF 3 ANGLES PER LONG SIDE & 2 PER SHORT SIDE, & 10 ANGLES TOTAL. FASTEN' E.F. VERTICAL AND #4 012 "o.c. E.F. HORIZONTAL r- g GROUT FILLED CELL AT EVERY CORNER, BOTH EDGES OF EVERY OPENING AND AS T -5 " " INDICATES #5 TOP BARS 0 12 o.c. (14 LONG W/ 10 HOOK) W- 13) ( INDICATES 8" CIP CONCRETE WALL W / #5 ®10 "c /c E:W. E.F. g INDICATED PER THE MASONRY WALL SCHEDULE. > INDICATES #5 TOP BARS 14) DRILL & EPDXY REBAR 5" INTO CONCRETE. 08/14113 5) INTERIOR MASONRY WALLS ARE TO STOP 1/2 BELOW CONCRETE SLAB ABOVE. - - - INDICATES #5 BOTTOM BARS 15) , ALL, PARAPET ..WALLS.,9RE­ MW-4 -TYPICAL ,U:N.O: A ... -d NOTE: A MINIMUM OF TWO TENDONS SHALL BE PROVIDED IN EACH ai 6) PROVIDE CONTROL JOINTS BETWEEN MASONRY A DENOTES #5 0 12" TOP & BOTTOM Q 16) PROVIDE L6x4x1 /2 "x12" LG GALVANIZED STEEL ANGLES ® EA. ENDS & MIDPOINTS OF INTERIOR GENERATOR /FUEL DIRECTION THROUGH SUPPORT COLUMNS (PER ACI 18.12.4) y: M � ° WALLS AND INTERIOR COLUMNS AND SHE ARWALLS " " W HI TI HIT HY150 ADHESIVE TANK. CURB &FASTENED ANGLE TO SLAB W/ 3/4 DIAM. BOLTS W/ 8 EMBED / L Site an Resubmission 07124112 EXCEPT THE AREA OVER THE SPREAD FOOTINGS. SR -# INDICATES STUD RAIL SHEAR REINFORCING. SYSTEM. THERE IS A TOTAL OF 3 ANGLES PER LONG SIDE & 2 PER SHORT SIDE, & 10 ANGLES TOTAL. FASTEN' : -F 5� 0o Permit Set SEE TYPICAL DETAIL ON SHEET 04.01 THE CURBS TO THE ANGLES W/ FASTENERS INCLUDED WITH EQUIPMENT CURB BY MANUFACTURER. GENERATOR W/ Structural Drawing Updated 12 -20 -13 M o 7) ALL REINF. BARS ON PLAN ARE #5 U.N.O. AMOUNT OF FUEL TANK MAXIMUM SERVICE WEIGHT (WET) =2,900 LBS. FUEL TANK SERVICE WEIGHT (WET) =3,340 LBS. Based on Architectural Backgrounds Dated 10 -28 -13 08/14113 BARS ARE INDICATED ON PLAN. 09113113 DeyelVngntal Agreement -2nd HeadDg ea k r, 4: .` >�fi 0 11 1 Or (OEDERI P:E: L• ORIDA" .F . a REG. #60791 PERMIT SIFT 11/20/13 I I Z I I [ t I I Ci r ARCHITECTURE & C. - INTERIOR DESIGN, INC. -` - mANs m, I ARCfiI wnm I weam D6S m C m 745 odenta avenue, suite 1121 altamonte springs, fl 32701 -` phone: 407.830.1400 Ce fax: 407.830.4143 AA0002731 www.forumarchitecture.com m r 2 LL up° °pn 0 aoo °fin C D c U C BENEFICIAL COMMUNITIES a 2206 Jo-An Drive Sarasota, FL 34231 Metro South Apartments South Miami, FL i SET DISTRIBUTIONS: i r r r r I 04123112 Owner Review 05116112 Site Plan Resubmission 05123112 Site Plan Resubmission 06/28112 Site an Resubmission 07124112 Owner Review 07131112 90% kDgress Set 08113112 Permit Set 06126113 8 Story Elevations 07117/13 61817 Sto Bevations 07118/13 417 Stojy Elevations _ 08/14113 Develognental Agreement Revisions 09113113 DeyelVngntal Agreement -2nd HeadDg 10118113 Revision Prooress Set 11120113 Issued for Permit Q SHEET REVISIONS: 10125113 4 Seven Story Revision 12124/13 5 Coordinatlon 03112114 10 AST Systems Comments 03126114 12 Building Depadrnent Comments #3 04107/14 15 Misc. Coordination 06118114 16 Structural Re-engineednIg 07!31 /14 17 Crane Tower Foundation Rev. U EDITED BY: Yp r PROJECT NO. 11 -2795 U Z 0 0 W 0 0 Foundation / os W First Floor Plan D W F U Q S3.10 0 LL ,