11-816-005PARTIAL FIRST FLOOR N DEMO PLAN SCALE 1/4" = 1' -0" (�l ALTERNATE Is 61VE AN ALTERNATE PRICE TO REPLACE ALL ELECTRICAL OUTLETS, IN ROOMS 0101, #102, #103 ALTERNATE 2. REPLACE WOOD DOOR #3 TO FILE ROOM WITH NEW HARDWARE PER DOOR SCHEDULE. SPECIFIC DEMOLITION NOTES: DEMOLITION ELAN LEGEND TYPE EXI5TING TO REMAIN TYPE – — — — — — – EXISTING TO BE DEMOLISHED 1O REMOVE EXISTING FLOORING AND BASE. (REMOVAL OF CARPETING SHALL BE COMPLETED BY OWNERS ABATEMENT ( ONTRAGTOR) O REMOVE EXI5TIN67 DOOR. @ EXI5TING DOOR TO BE REMOVED AND RELOCATED. (5EE FLOOR PLAN FOR NEW LOCATION) O REMOVE EXISTING PORTION OF WALL AS INDICATED AND /OR REQUIRED. O REMOVE EXISTING DOOR d FRAME REPLACE. PREP TO RECEIVE NEW WALL PARTITION. PATCH d REPAIR EXISTING ADJACENT AREAS AS REQUIRED. O LIGHT SWITCH TO BE RELOCATED. O EXISTING FIRE EXTINGUISHER TO REMAIN. O EXISTING ELECTRICAL OUTLETS TO REMAIN. ® EXISTING DATA OUTLETS TO REMAIN. gO EXISTING UPPER WALL MOUNT CABINETS ABOVE OE5K5 TO BE REMOVE AND REINSTALL. PRIOR TO START OF CONSTRUCTION RE- ANCHOR AT SAME LOCATION UPON COMPLETION. COORDINATE 5TORAGE WITH OWNER. 99 EXISTING UPPER WALL MOUNT CABINET TO BE REMOVE AND RELOCATED. COORD 5TORAGE d EXACT FINAL LOCATION IN OWNER. TO PROVIDE BACKING. 10 EXISTING DOOR TO REMAIN. 11 EXI5TING CEILING TILE AND GRID TO BE REMOVED. GENERAL DEMO NOTES: 1. WALL HUNG ART -WORK TO BE REMOVED, STORED, d RE -HUNG BY OWNER. EXISTING ANCHORS TO REMAIN. (TYPJ LEGEND TYPE DESCRIPTION TYPE DESCRIPTION a EXI5TIN6 ELECTRIC OUTLETS < X� PARTITION TYPE NUMBER OX DOOR TYPE r 24'x24' SUPPLY AIR DIFFUSER PATH OF TRAVEL (X' -X') LIGHT FIXTURE DISTANCE PER LEG FE NEW 2'X2' ACOUSTIC TILE FIRE EXTINGUISHER d GRID SYSTEM EXISTING WALL NEW DRYWALL PARTITION ALIGN NEW PARTITION TO ADJACENT WALL 1 5 EXISTING EXISTING OFFICE OFFICE I103 � 102 FE� .1 0 L ALIGN NEW PARTITION 1 TO ADJACENT WALL 1 1 NEW SWITCH < 1 4 J LO( ATION —rj_ + F_ 2 3 EX NEW FINISHES TO MATCH TH15 ROOM 1 I�FE n ... EXISTING OFFICE 104 EXI5TIN6 DOOR TO BE SANDED AND RE -STAIN TO MATCH NEW. SEE FIN15H SCHEDULE 0 PARTIAL FIRST FLOOR PLAN SCALE 1/4" = 1' -0" SPECIFIC FLOOR PLAN WORK NOTES: EXISTING MEDICAL STAFF OFFICE / RECEPTION 101 5 LSJ� L N EXISTING HALLWAY 100 1❑ NEW CARPET TO MATCH EXISTING ADJACENT SPACE (EXI5TIN6 OFFICE #104). CONFIRM SAMPLE 5ELECTION WITH OWNER. R2 FILL IN OPENING WITH NEW TYPICAL INTERIOR PARTITION (PI WALL TYPE). PATCH d REPAIR EXI5TING ADJACENT AREAS AS REQUIRED. R3 EXI5TING DOOR IN NEW LOCATION. PATCH d REPAIR EXI5TING ADJACENT AREAS AS REQUIRED. ® EXISTING WALL MOUNT CABINETS TO BE REINSTALLED. R5 EXISTING WALL MOUNT CABINETS TO BE REINSTALLED. 6.6 TO PROVIDE BACKING FOR NEW LOCATED WALL MOUNTED UPPER CABINET. VERIFY EXACT FINAL LOCATION WITH OWNER. GENERAL DEMOLITION NOTES: I. TITLE TO MATERIALS: TITLE TO ALL MATERIAL AND EQUIPMENT TO BE DEMOLISHED AND REMOVED EXCEPTING ITEMS INDICATED TO BE TURNED OVER TO THE OWNER 15 VESTED IN THE CONTRACTOR AT START OF PROJECT. ALL PLUMBING FIXTURES, LIGHTING FIXTURES, A/C EQUIPMENT, APPLIANCES, TRAYS, SPECIALTY ITEMS, ETC. SHALL BE EVALUATED BY A REPRESENTATIVE OF THE M.H.5. AS TO THE STATUS OF THEIR REMOVAL. THE OWNER WILL NOT BE RESPONSIBLE FOR THE CONDITIONS, LOSS OR DAMAGE OF SUCH PROPERTY AFTER NOTICE TO PROCEED. 2. THE CONTRACTOR SHALL VISIT THE 517E OF THE WORK AND EXAMINE THE PLANS AND IT WILL BE A55UMED THAT THE CONTRACTOR HAS INVESTIGATED AND 15 FULLY INFORMED AS TO THE CONDITIONS AND MATERIALS TO BE ENCOUNTERED AS TO CHARACTER, QUALITY AND QUANTITIES OF WORK TO BE PERFORMED AND MATERIALS TO BE FURNISHED AND AS TO THE REQUIREMENTS OF THE PLANS. 3. THE CONTRACTOR SHALL REMOVE ALL SPECIFIC ITEMS INDICATED ON THESE DRAWINGS AND AL50 REMOVE ANY OTHER ITEMS OR CONSTRUCTION AS REQUIRED TO ACCOMPLISH ALL NEW WORK TO AREAS SHOWN 4. ALL REMOVED ITEMS SHALL BECOME THE PROPERTY OF THE CONTRACTOR WITH THE APPROVAL OF THE OWNER, AND SHALL BE REMOVED FROM THE SITE. 5. ALL DIMENSIONS SHOWN ARE TO BE VERIFIED IN THE FIELD AND ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROGEEDIN6 WITH THE WORK. 6. GENERAL CONTRACTOR SHALL DO ALL CUTTING AND PATCHING OF EXISTING CONCRETE SLABS, PARTITIONS, ETC. AS MAY BE REQUIRED FOR ALL TRADES TO AC-COMPL15H ALL WORK REQUIRED BY THESE CONTRACT DOCUMENTS. CONTRACTOR SHALL DO ALL PATCHING AND PROVIDE NEW FINISHES TO MATCH EXISTING 50 AS TO MAKE THE "PATCHED AREA' INDISCERNIBLE TO THE EXISTING ADJACENT AREA. 1. BUILDING CONTRACTOR TO REMOVE EXISTING FINISHES, CEILINGS, PARTITION WALLS, ETC. AS 5HOWN. PATCH d REPAIR EXISTING FINISHES DAMAGED BY DEMOLITION WORK THAT ARE INTENDED TO REMAIN. 8. THE CONTRACTOR SHALL OBTAIN ALL PERMITS REQUIRED FOR HAULING AND LEGALLY DISPOSING OF MATERIALS REMOVED IN DEMOLITION WORK. 8. THE AMOUNT OF DUST RE5ULTIN6 FROM DEMOLITION SHALL BE CONTROLLED TO PREVENT THE SPREAD OF DUST TO AVOID CREATION OF A NUISANCE IN THE 5URROUNDING AREA. USE OF WATER WILL NOT BE PERMITTED WHEN IT WILL RESULT IN, OR CREATE, HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOOOIN6 AND POLLUTION. 4. THE CONTRACTOR SHALL PROCEED WITH EXTREME CAUTION 50 AS NOT TO DISRUPT EXISTING UTILITIES. VERIFY LOCATION OF ALL UTILITIES PRIOR TO DEMOLITION WORK. REMOVE AND GAP ALL UNUSED LINES AS MAY BE REQUIRED. 10. COORDINATE THE EXTENT OF MECHANICAL/ ELECTRICAL/ PLUMBING DEMOLITION AND NEW WORK WITH THE MEP DRAWINGS. II. SEE ELECTRICAL DRAWINGS FOR THE LOCATION OF ALARMS, SMOKE DETECTORS, EMERGENCY EXIT LIGHTS AND SIGNS, ETC. EXI5TIN6 ITEMS ARE TO BE RE -U5ED WHERE APPLICABLE. 12. ANY LIGHT SWITCHES ON WALLS SCHEDULED TO BE REMOVED ARE TO BE RELOCATED TO CLOSEST ADJACENT WALL. 13. CONTRACTOR SHALL REMOVE AND RE- INSTALL EXISTING SPEAKERS, FIRE ALARM DEVICES, ETC. AS REQUIRED TO FACILITATE THE INSTALLATION OF NEW WORK. CONTRACTOR SHALL AL50 RELOCATE ANY EXISTING CONDUITS THAT INTERFERE IN INSTALLATION OF NEW DUCTWORK. COORDINATE WITH MECHANICAL CONTRACTOR TO MAINTAIN CIRCUIT CONTINUITY. 14. GARBAGE REMOVAL SHOULD BE BY COVERED CART ONLY. 15. CONTRACTOR SHALL BE RESPONSIBLE FOR COVERING AND PROTECTING ALL REMAINING EQUIPMENT AND CABINETRY. 16. ALL EXISTING SURFACES SUCH AS WALLS, FLOORS, CEILINGS, BASES, ETC. THAT ARE AFFECTED BY THESE ALTERATIONS AND WERE INTENDED TO REMAIN. ARE TO HAVE NEW MATERIAL AND FINISH AS REQUIRED TO MATCH ALL ADJACENT EXISTING FINISHES. 11. PROTECTION, PROVIDE TEMPORARY BARRICADES AND OTHER FORMS OF PROTECTION AS REQUIRED TO PROTECT GENERAL PUBLIC FROM INJURY DUE TO SELECTIVE DEMOLITION WORK. 18. PROVIDE PROTECTIVE MEASURES AS REQUIRED TO PROVIDE FREE AND SAFE PASSAGE OF OWNERS PERSONAL AND GENERAL PUBLIC TO AND FROM OCCUPIED PORTIONS OF BUILIDNGS. PARTIAL FIRST FLOOR CEILING PLAN SCALE 1/4" = 1' -0" SPECIFIC REFLECTED CEILING PLAN WORK NOTES: O NEW GYP5UM BOARD HEADER AT 6'-8' A.F.F. (VERIFY WITH ADJACENT EXISTING HEADER). 2O NEW CEILING TILE AND GRID. (SEE FINISH SCHEDULE) 3O NEW 2'x2' RECESSED FLUORESCENT LIGHT FIXTURE. MANUFACTURE: LITHONIA LIGHTING MODEL NO. 2RT5 25T5 MVOLT 6EBg5 LPM&41P O NEW 2'x4' RECESSED FLUORESCENT LIGHT FIXTURE. MANUFACTURE: LITHONIA LIGHTING MODEL NO. 2RT5 28T5 MVOLT GEE1415 LPM&41P O EXI5TIN6 A/C DIFFUSER TO BE REMOVED AND REINSTALLED . O EXI5TING RETURN AIR GRILL TO BE REMOVED AND REINSTALLED. PROVIDE MAIN RUNNERS GONTINUOU5 IN LINE WITH EACH 51DE OF RECE55ED LIGHT AND PARALLEL MAXIMUM 4' -0' ON CENTERS IN THE CEILING FIELD. CRO55 RUNNERS SHALL BE MAXIMUM 2' -0' ON CENTERS. PROVIDE ACCESSIBLE HOLD -DOWN CLIPS FOR ACOUSTIC TILES LE55 THAN I LBJ50.FT. PROVIDE MINIMUM 12 GAUGE GALVANIZED STEEL HANGER WIRE MAXIMUM 4' -0" ON (ENTERS ALONG MAIN RUNNERS. SUSPENDED CEILING SCALE: N.T.5. NEW ACOUSTICAL CEILING SYSTEM 1. MANUFACTURER ARM5TRON6 OR APPROVED EQUAL AS FOLLOWS, TESTED PER A5TM E 84 AND COMPLYING WITH ASTM E 1264 FOR CLA55 A PRODUCTS. I. FLAME SPREAD: 25 OR LESS. 2 SMOKE DEVELOPED: 50 OR LESS. 2. ACOUSTICAL CEILING: MINERAL FIBER, CONFORMING TO ASTM -E -1264 TYPE III FIRM I, CLA55 A. SEE FINISH 56HEME FOR ADDITIONAL INFORMATION. 3. CONFIRM SAMPLE OF SELECTION WITH OWNER. O� w0a o � H� �o A SALTZ MICHELSON N A R C H I T E C T S 3501 Griffin Road Ft. Lauderdale, FL 33312 (954) 266 -2700 Fx: (954) 266 -2701 sma@saltzrnichelson.com AA- 0002897 _,.,:�'jP''' �•�... t,. 1 ! ..S Al __..r,� /+ IN SOUTH MIAMI OF SOUET. �3UlL.DIi IG B F' DTi- �UCTUR�'ECTIOPf ;,�,� t�VED BY• - - I� ev ay R- a K i ��,I ea7• >> _ , -• III ►J Q„�ir =t ; Q o • I RENOVATION KEY • • Charles Michelson AR0009976 U s Wa7 Q a Project No.: 2011 -168 Drawn By: GM Checked By: LS Date: 08 -10 -11 Revisions "I L r Charles Michelson AR0009976 U s Wa7 Q a Project No.: 2011 -168 Drawn By: GM Checked By: LS Date: 08 -10 -11 Revisions "I