09-302-001S./ SCOPE
3: l COPE
7 n�nn
-U-UUU(
PREFABRICATED WOOD
TRUSSES @ 24' GC
TRUSS CONFIGURATION BY
TRU55 MANUFACTURER. TRUSS
SHOP DWG's TO BE SUBMITTED
FOR BOTH THE BLDG.
DEPARTMENTS APPROVAL AND
PROJECT ARCHITECTS
APPROVAL
FOR ALL GENERAL CONDITIONS
REFER TO SECTION 13/A2 @ RIGHT
HGT. OF RIDGE &_! #I I" AFF -TYP.
HURRICANE STRAP SEE STRUCTURAL
DWG.5 TYPICAL
�- 8806.3 VENT CLEARANCE.
INSULATION SHALL NOT BLOCK THE
FREE FLOW OF AIR. A MINIMUM OF A
/ - I IN SPACE SHALL BE PROVIDED
BETWEEN THE INSULATION AND THE
ROOF SHEATHING AT THE LOCATION
OF THE VENT.
F7 ili:31 Aiik T.O.B: 8' -2" AFF -TYP
TB
NO. 9 GAUGE HORT. JOINT REINF. @
I G' C/C. (LADDER TYPE) EXTEND MIN.
4" INTO TC
0
U'
m
w
'o
0
N
MM
C
CV
N
al
�v-
M.
• OVERALL BLDG. r
EVERY BATHROOM
Illlllllllllllllllllllllllllli illlllllllllllllll' � i�illlllllllllllllllia
�� • � IIII
DOOR
DE51GNED TO ALLOW
OPENING FROM
OUT51DE DURING Jj
EMERGENCY WHEN
i�
LOCKED.
FDTa
LMNG
u�
D I MODEL
ONE STORY 51NGLE
y FAMILY RESIDENCE
CONSTRUCTION ELEV.: 0-0"
5EE 51TE PLAN FOR. N..V.D.
LG. MISSILE IMPACT
DOOR COMPLIES AS
POST STORM EGRE55
see FBC R 310.4
. C01dSTRU MONTI_.s' -6 ". FFF : '�'• ' �:
LAN FOR*gGVD'
'4:.G0�1�. �lf�l� and $IZQOM'FItvI�H.Y f :1. • �,._'- '•M .
•, i- i•FOR�ADDT IVOI WAD.09. {-
FLORIDA BUILDING CODE 2004 RESIDENTIAL
FBC B 310: OCCUPANCY R-3 SINGLE FAMILY (I STORY)
13' -10"
F Plan
WOOD TRUSSES TO COMPLY W/ ---\
2004 FBC 2319.17, INCLUDING
2319.17.2.1 PREFABRICATED WOOD
TRUSSES SHALL BE DESIGNED BY A
PROFESSIONAL ENGINEER...AND
FABRICATED IN ACCORDANCE WITH
THE NATIONAL STANDARD FOR
METAL PLATE CONNECTED WOOD
TRU55 CONSTRUCTION OF THE
TRUSS PLATE INSTITUTE (TPI -95).
THE TRUSS SYSTEM DESIGNER...
SHALL PREPARE THE TRUSS SYSTEM
SHOP DRANfING5 SUCH SHOP
DRAWINGS SHALL BE SUBMITTED TO
THE BUILDING OFFICIAL FOR REVIEW
AND APPROVAL.
R -30 BATT INSULATION IN -
CEILING -TYP.
I X2 (min.) PT CONT. -TYP.
TB: SEE 5 -1 PROVIDE 2 #5 CORNER
BAR5 w/ 30" LEGS @ EA. CORNER t
INTERSECTIONS. SEE 5CHED. SHT. 51
FOR ADDT. INFO.
112" GWB ON IX3 5TRJPPING @ I G' -
0 /C- TYPICALALL INTERIOR FINISHES
TO BE SELECTED BY OWNER
1/2' GWB ON IX2 PT FURRING wl -
R -4.1 FOIL OR RIGID BD.TYP.
8' CMU WALL: 1 #5 @ 40' GC VERT.
IN BLOCKC11i FILLED W/ CONCRETE
GROUT t NO.9 GAUGE HORT. JOINT
REINF. @ I G' GC. VERT (LADDER
TYPE) EXTEND MIN. 4" INTO TC
4'-
b
�I m
IN
SECONDARY MEANS OF ESCAPE: AN OUTSIDE
WINDOW OR DOOR OPERABLE FROM THE IN51DE
W10 THE USE OF TOOLS, KEYS, OR SPECIAL
�= EFFORT AND PROVIDING A CLEAR OPENING OF
�! NOT LE55 THAN 20 IN. IN WIDTH * 24 IN. IN
8" HEIGHT, AND 5.0 5F (GROUND FL) t 5.7 SF
(SECOND FL) IN AREA. THE BOTTOM OF THE
OPENING SHALL NOT BE MORE THAN 44 IN.
a� ABOVE THE FLOOR. 2004 FBC 8310 t R31 I
8307.2 BATHTUB AND SHOWER SPACES.
0 BEDRM -B BATHTUB AND SHOWER FLOORS AND WALLS
ABOVE BATHTUBS WITH INSTALLED SHOWER
HEADS AND IN 5HOWER COMPARTMENTS SHALL
BE FINISHED WITH A NONABSORBENT SURFACE.
SUCH WALL SURFACES SHALL EXTEND TO A
N HEIGHT OF NOT LE55 THAN 6 FTA13OVE THE
Door Schedule NOTE: ALL JAMBS, TRIM AND MOLDINGS TO BE WOOD - PAINT Gi ADE
v- I
ROOM
5 1 Z E
STYLE
TYPE
CC)
D- I
ENTRY
3Gx80x 1 -314
MTL. INSUL.
LG. MISSILE IMPACT -5GL. D5/KEY
4'-
b
�I m
IN
SECONDARY MEANS OF ESCAPE: AN OUTSIDE
WINDOW OR DOOR OPERABLE FROM THE IN51DE
W10 THE USE OF TOOLS, KEYS, OR SPECIAL
�= EFFORT AND PROVIDING A CLEAR OPENING OF
�! NOT LE55 THAN 20 IN. IN WIDTH * 24 IN. IN
8" HEIGHT, AND 5.0 5F (GROUND FL) t 5.7 SF
(SECOND FL) IN AREA. THE BOTTOM OF THE
OPENING SHALL NOT BE MORE THAN 44 IN.
a� ABOVE THE FLOOR. 2004 FBC 8310 t R31 I
8307.2 BATHTUB AND SHOWER SPACES.
0 BEDRM -B BATHTUB AND SHOWER FLOORS AND WALLS
ABOVE BATHTUBS WITH INSTALLED SHOWER
HEADS AND IN 5HOWER COMPARTMENTS SHALL
BE FINISHED WITH A NONABSORBENT SURFACE.
SUCH WALL SURFACES SHALL EXTEND TO A
N HEIGHT OF NOT LE55 THAN 6 FTA13OVE THE
Door Schedule NOTE: ALL JAMBS, TRIM AND MOLDINGS TO BE WOOD - PAINT Gi ADE
#
ROOM
5 1 Z E
STYLE
TYPE
N 0 T E 5
D- I
ENTRY
3Gx80x 1 -314
MTL. INSUL.
LG. MISSILE IMPACT -5GL. D5/KEY
-
D -2
EXT. LAUNDRY
3Gx80x 1 -3/4
MTL. INSUL.
LG. MISSILE IMPACT -5GL. DBIKEY
-
D -3
AC CLOSET
32x80x 1 -3/8
FULL LOUVER
BI -FOLD
VERIFY DOOR STYLE w/ OWNER
D -4
LAUNDRY
32x8Ox 1 -3/8
SOLID
SWING- PASSAGE
PAINT FINISH : ,
D -5
BEDROOM B
32x80x 1 -3/8
SOLID
SWING- PRIVACY
COMPLY HAZARDOUS GLAZING CAT. II -
D -G
CLOSET
48x80x 1 -3/8
FULL LOUVER
DBL. BI -FOLD
POL. CHROME HRDWR- VERIFY STYLE w/ 0Yi NZi�
D -7
CLOSET
24x80x 1 -318
FULL LOUVER
BI -FOLD
POL. CHROME HRDWR- VERIFY STYLE w/ OWNER
D -8
BATHROOM
32x80x1 -3/8
SOLID
SWING - PRIVACY
"'2004 FBC R322. 1.1 ACCESSIBILITY
D -9
CLOSET
24x80x 1 -3/8
FULL LOUVER
DBL. BI -FOLD
PAINT FINISH
D 10
BEDROOM A
32x80x 1 -3/8
SOLID
SWING - PRIVACY
COMPLY HAZARDOUS GLAZING CAT. II
D I I
CLO ET
48x80x 1 -318
FULL LOUVER
DBL. BI -FOLD
COMPLY HAZARDOUS GLAZING CAT. 11
WOOD TRUSSES
= _ AT;ACH °P,RTIT10"J5 -f0 Ct: ?LING -�= -
5T °IPFIhG OR 1`0V�)E 2KH0CgNG
DO NOT A(TACH PARTI'i INNS - - ^ - - - - -
DIRECTLY TO TRU55 CHORDS
IX3W5- 51RIPPINGJai I-0G/%,
- wl 1 /2" &5- TYPICA, : 'k4409. i .15 WA1LTOUAG fF,(TU-RZJ. ^ �-
5TUD5 IN BEARING WALLS, EXTERIOR
WALLS AND NONBEARING PARTITIONS
SUPPORTING WALL HUNG PLUMBING
FIXTURES AND WALL CABINETS SHALL BE
NOT LESS THAN 2 X 4, WHERE SPACED
NOT MORE THAN 16 INCHES (406 MM) ON J FLOOR. '11.1 CENTER OR NOT LE55 THAN 2 X 6 WHERE ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL
PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED SPACED NOT MORE THAN 24 INCHES (6 10
g" DESIGN AND CONSTRUCTION SHALL COMPLY ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM 15 MM) ON CENTER. /.
WITH THE FLORIDA BUILDING CODE RESIDENTIAL
2004 PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LESS THAN 29 IN. 2X4 WOOD STUDS @ 16" O/C
R31 1.4.1 EXIT DOOR REQUIRED. NOT LESS THAN ONE EXIT DOOR CONFORMING TO THIS SECTION SHALL BE PROVIDED w/ 1/2 2' C EA. SIDE
8807.1 ATTIC ACCESS. THE ROUGH- FRAMED FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE (USE 1 /2' CEMENTITUOUS BD IN WET AREAS)
(USE 112' M.R. GWB IN BATH AREAS) �
P A N T E TWA 22" " PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE ACCESS TO -
-
#
ROOM
5 1 Z E
STYLE
0 ENING 5H LL 0 B LESS N X 30
N 0 T E 5
W I
R307.2 BATHTUB AND SHOWER
37 x G3
C3
TINTED
EGRESS
W I
BEDROOM-13
37 x G3
AL. 5GL. HUNG /25
AND SHALL BE LOCATED IN A HALLWAY OR
HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THIS SECTION SHALL BE BY A RAMP IN ACCORDANCE
W-2
SPACES. BATHTUB AND SHOWER
37 x 38 318
AL. 5GL. HUNG/23
TINTED - TEMPERED
OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC.
m
LIVING ROOM
37 x G3
AL. 5GL. HUNG /25
4'-0"
OTHER READILY ACCESSIBLE LOCATION. A 30'
WITH SECTION R31 1.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R31 1.5 .
DINING ROOM
FLOORS AND WALLS ABOVE
m
TINTED
90 DEGREE CUT FASCIA ASSEMBLY:
W -4
KITCHEN
37 x 50 518
AL. 5GL. HUNG /24
TINTED
x x x-
MINIMUM UNOBSTRUCTED HEADROOM IN THE
R3 1 1.4.2 DOOR TYPE AND SIZE: THE REQUIRED EXIT DOOR SHALL BE A SIDE - HINGED DOOR NOT LE55 THAN 3 FT IN
- - -x-
BATHTUBS WITH INSTALLED
s
o~
z
SLAB RENFORCING
'v
CJ
FROM STRUCTURE
ATTIC SPACE SHALL BE PROVIDED AT SOME
WIDTH AND 6 FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM
SHOWER HEADS AND IN SHOWER
-" x x x x-
z
-'
WELL CCMPACTED BASE - SEE
;'� �•,
POINT ABOVE THE ACCESS OPENING.
DIMENSIONS.
COMPACTION NOTES 5HT. 51
COMPARTMENTS SHALL BE
L)
U
�' •:;
R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH SIDE OF EACH EXTERIOR DOOR.
WF- I G: SEE 5-1 5CH ED. FOR
FINISHED WITH A NONABSORBENT
; ; • ` j '
•
\L[2.48
��
ADDT INFO
'
X% X4 CONC. SLAB w/ BROOM FIN15H -5EE
EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER
SURFACE. SUCH WALL SURFACES
2' -3"
8' -4"
' ••` °.'
S 1 FOR ADDT INFORMATION
THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR.
SHALL EXTEND TO A HEIGHT OF
II
I
LAUNDRY
��
<�
THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED 132 SECTION R3 1 1.4.1 SHALL NOT BE REQUIRED TO COMPLY
NOT LE55 THAN 6 FEET (I 829
_
• .:
.1,...
, , .
8310.4 (PARTIAL) THE TEMPORARY
WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R311.5.3
MM) ABOVE THE FLOOR.
FIE--
-----
' .' :
' `.
INSTALLATION OR CLOSURE OF STORM
SHUTTERS, PANELS, AND OTHER APPROVED
EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE
r-----,r i
• -
.'
HURRICANE PROTECTION DEVICES SHALL BE
THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR 5CREEN DOOR DOES NOT SWING OVER THE
USE PT 2X4 @@BOTTOM
PLATE 2 POWDER DRIVEN
PERMITTED ON EMERGENCY ESCAPE AND
LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LE55 THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A
w/ -1A'
FASTENERS w/ WASHERS 36" MAX.
i ii i i 40 GA�I
RESCUE OPENINGS DURING THE THREAT OF A
MINIMUM DIMENSION OF 36 IN MEASURED IN THE DIRECTION OF TRAVEL. R3 1 1.4.4 TYPE OF LOCK OR LATCH.ALL
OR 2 -1 /4" CUT NAILS @ 3 - MAX
��"�\
AHU
L WASHJL DRYJ \-,ewh ;
"-
;�.' "' ;,
STORM. SUCH DEVICES SHALL NOT BE
REQUIRED TO COMPLY WITH THE OPERATIONAL
EGRESS DOORS SHALL BE READILY OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE WITHOUT THE USE
CONCRETE FLOOR SLAB
-- - --
CONSTRAINTS OF SECTION 8310.1.4. WHILE
OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT.
..; , •,;:. , ..; . -.:
REF
- - -�
.
�� • �' �•'' •' �� �
�° ..
SUCH PROTECTION IS PROVIDED, EL LEAST ONE
MEANS OF ESCAPE FROM THE DWELLING OR
8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE
AND RESCUE "�
C'� �p• Interior Partition
N.T.S.
MEANS Of SCAPE SHALL BE WITHIN THE FIRST
SHALL HAVE A SILL HEIGHT OF NOTOMORE THAN 44 IN. A50VE THE FLOOR. NET CLEAR OPENING DIMENSIONS
8� I
FLOOR OF THE DWELLING OR DWELLING UNIT
REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE
AND SHALL NOT BE LOCATED WITHIN A GARAGE
WITHOUT A SIDE HINGED DOOR LEADING OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE
4" DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2
PART OF THE DWELLING OR DWELLING UNIT 8310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET
DINING IaTCNEM SHALL BE ABLE TO ACCESS THE MEANS OF CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF
APPLIANCES ARE Al C ESCAPE WITHOUT PASSING THROUGH A 8310.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN.
TINS PERMITTOF f' UNIT �\ LOCKABLE DOOR NOT UNDER THEIR CONTROL. 8310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN.
- A/C SLAB TO BE SET @ FINISH FLOOR R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE
ELEVATION INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS.
0 O I 84409.13.5 (8320. I) TERMITE PROTECTION.
t ALL BUILDINGS SHALL HAVE A
b PRE - CONSTRUCTION TREATMENT PROTECTION
AGAINST SUBTERRANEAN TERMITES. THE RULES
AND LAWS AS ESTABLISHED BY THE FLORIDA
DEPARTMENT OF AGRICULTURE AND CONSUMER
SERVICES SHALL BE DEEMED AS APPROVED
WITH RESPECT TO PRECON5TRUCTION 501L
TREATMENT FOR PROTECTION AGAINST
6' -0" 9' -0" 5' -4" SUBTERRANEAN TERMITES. A CERTIFICATE OF
COMPLIANCE SHALL BE 155UED TO THE
BUILDING DEPARTMENT BY THE LICENSED PEST
8" CONTROL COMPANY THAT CONTAINS THE
FOLLOWING STATEMENT: "THE BUILDING HAS
5/8" ROOF SHEATHING -SEE 5 -1
SHEET FOR ADDT. INFO.
HURRICANE STRAP SEE
STRUCTURAL DWG.5 TYPICAL
2XG P.T. CONT. BLK'G. w/ 1/2'
DIA. WEDGE BOLTS @ 24' CI
MIN. EA. END (PORCH ONLY)
s•�
\2S�OPE
3: l2 SLOPE
Window Schedule (SEE'GENERAL NOTES' FOR WINDOW AND DOOR DATA.)
#
ROOM
5 1 Z E
STYLE
GLAZING
N 0 T E 5
W I
BEDROOM -A
37 x G3
AL. 5GL. HUNG /25
TINTED
EGRESS
W I
BEDROOM-13
37 x G3
AL. 5GL. HUNG /25
TINTED
EGRESS
W-2
BATHROOM
37 x 38 318
AL. 5GL. HUNG/23
TINTED - TEMPERED
OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC.
W -3
LIVING ROOM
37 x G3
AL. 5GL. HUNG /25
TINTED
HURRICANE STRAP SEE STRUCTURAL
W -3
DINING ROOM
37 x G3
AL. 5GL. HUNG /25
TINTED
90 DEGREE CUT FASCIA ASSEMBLY:
W -4
KITCHEN
37 x 50 518
AL. 5GL. HUNG /24
TINTED
x x x-
NAILS EA. TRUSS KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE
C DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A
FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET
RECEIVED A COMPLETE TREATMENT FOR THE
PREVENTION OF SUBTERRANEAN TERMITES.
General Door a Window Notes ( SEE ELEVATIONS FOR WIND PRESSURES)
SCALE: I/4" : I' -0"
TREATMENT IS IN ACCORDANCE WITH RULES
AND LAWS ESTABLISHED BY THE FLORIDA
8303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED
DEPARTMENT OF AGRICULTURE AND CONSUMER
WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE.
ROOFING NOTE: (SEPARATE PERMIT
SERVICES."
EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM
REQUIRED) GAF TIMBERLINE 30
ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR
SHINGLE NOA #06- 1211.02 OR EQ.
#30 w/ TIN CAP R5 NAILS : G' C/C @
6"X6 " -W 1.4 X 1.4 @
CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE.
LAPS # 12' GC FIELD ASPHALT
1.4 @ MID -DEPTH OF SLAB ON
R308.4 HAZARDOU5 LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM
SHINGLES w/6 R5 NAILS/SHINGLE (1)
@ EA. CORNER (2) @ EAITAB
ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE
SEPARATION- TYP.
MTL. RIB LATH USE 1 -1 /4" TIN CAP @ GUILDING SECTION INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE
THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60 IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR
4' O/C TO VERT. TRU55 MEMBERS.
G' o1c w/ MIN. 1/2' STUCCO KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD
WALKING SURFACE.
HURRICANE STRAP SEE STRUCTURAL
FIN. - TYPICAL BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF
1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION
�- DWG.5 TYPICAL TRU55 CONDITION
8 ' 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE
2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR
90 DEGREE CUT FASCIA ASSEMBLY:
SOFFIT VENT: 4"X22" AL. SCREEN VENT FBC R 2004 HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON - REMOVABLE PINS.
DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING
4'- Aj, I X2 * 2XG P.T. MI 111 (2) 1 Gd
- - - - - - - -- _ _
BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE
NAILS EA. TRUSS KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE
C DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A
FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET
PAPER BACKED MTL. LATH W/
STUCCO FINISH.
HAND APPLIED STUCCO FINISH (1 /2"
MIN.) LIGHT TEXTURE/PAINT FINISH
COMPLY W/ FBC 2004 - 8806.1 #
806.2 (FOR AREA SEE ROOF PLAN)
8806. I VENTILATION REQUIRED.
ENCLOSED ATTICS AND ENCLOSED
RAFTER SPACES FORMED WHERE
CEILINGS ARE APPLIED DIRECTLY TO
THE UNDERSIDE OF ROOF RAFTERS
SHALL HAVE CROSS VENTILATION FOR
EACH SEPARATE SPACE BY
VENTILATING OPENINGS PROTECTED
AGAINST THE ENTRANCE OF RAIN.
VENTILATING OPENINGS SHALL BE
PROVIDED W / CORROSION - RESISTANT
WIRE MESH, w/ I18 IN MIN. TO A IN
MAX. OPENINGS.
VINYL FLOOR TILE FINISH
FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3.
4" CONOZETE SLAB W/
_T_O.B: 8' -2' APF -TYP. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC R4410.2 IMPACT
4" CONCRETE SLAB W/ G'%G " -W 1.4 X
RB-1: SEE 5 -1 5CHED. FOR
RESISTANT GLA55 (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE
6"X6 " -W 1.4 X 1.4 @
ADDT. INFO.
24'± TYP LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY or. SOUTH
1.4 @ MID -DEPTH OF SLAB ON
STANDARD HOOK PORCH CEILING NOTE: 5/8' CDX
CiTy BUILDING DEPT.' MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR 51DE.8.ALL NEW
BUILDING EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS 05THE 2004 FLORIDA BLDG. RESIDENTIAL CODE
SOFFIT: ASPHALT PAPER - BACKED
MID -DEPTH OF SLAB OVER 6
PLYWOOD W/ 8d COMMON NAILS @
MTL. RIB LATH USE 1 -1 /4" TIN CAP @ GUILDING SECTION INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE
SOIL. (BROOM
4' O/C TO VERT. TRU55 MEMBERS.
G' o1c w/ MIN. 1/2' STUCCO KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD
TRUSS MANUFACTURER TO PROVIDE
FIN. - TYPICAL BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF
g
2X VERT. MEMBERS @ 24" 0/C
8 ' 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE
ALONG PLYWOOD EDGES W /VED
SOFFIT VENT: 4"X22" AL. SCREEN VENT FBC R 2004 HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON - REMOVABLE PINS.
PAPER BACKED MTL. LATH W/
STUCCO FINISH.
HAND APPLIED STUCCO FINISH (1 /2"
MIN.) LIGHT TEXTURE/PAINT FINISH
COMPLY W/ FBC 2004 - 8806.1 #
806.2 (FOR AREA SEE ROOF PLAN)
8806. I VENTILATION REQUIRED.
ENCLOSED ATTICS AND ENCLOSED
RAFTER SPACES FORMED WHERE
CEILINGS ARE APPLIED DIRECTLY TO
THE UNDERSIDE OF ROOF RAFTERS
SHALL HAVE CROSS VENTILATION FOR
EACH SEPARATE SPACE BY
VENTILATING OPENINGS PROTECTED
AGAINST THE ENTRANCE OF RAIN.
VENTILATING OPENINGS SHALL BE
PROVIDED W / CORROSION - RESISTANT
WIRE MESH, w/ I18 IN MIN. TO A IN
MAX. OPENINGS.
1VA2 Typical Section B /A2 Section Throuoh Porch
SCALE: 3/4": P -0"
SCALE: 3/4' : V -0"
,�,TE: 10 0
.gip SOU T ii vAIAIVII
B,_JILDING DEP`i*.
S, - `tJCTU1 i- ECTIONI
*PROVED B`f: - ........,.
=,3
ATTIC VENTILATION BASED ON 2004 FBC 8806.2 vjz:
ATTIC AREA: 1326 5F @ (1/ 150) = 9 SF RECD.
LOWER: SAVE VENTS (022) @ .5 SF EA. = 18 TOTAL
2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS
PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN
80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE
UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE SAVE OR CORNICE VENTS
WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY SAVE OR CORNICE VENTS. AS AN
ALTERNATIVE, THE NET FREE CR055- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A
VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM IS INSTALLED ON THE
WARM 51DE OF THE CEILING.
Roof Plan
SCALE: 1/8" : P -0"
DATE: 10 -11 -08
PROJECT: _ New 1 Sty SFR
ADDRESS: 60" SW 64 TR
South Mlaml, Florida
OWNER: Habitat for Humanity
Anne Manning, Exec. Director
305 670 -2224
REVISIONS: 111-13-09
TM
A11
/%/ %0
r�.D%
SEAL
FEB 1'7 2008
ARCHITECT OF RECORD:
PAUL W. BUCKLER
AR13708
muwr r OF GREATER NMI, IMO.
a �',���„
i
38COMW22AYEIIOE
IMMIMb FLORIDA 33142
305. 838-0192
AGEMT: AMME WHIN, EMECOTM DIRECTOR
ARCHITECTURAL
20111
VINYL FLOOR TILE FINISH
4" CONOZETE SLAB W/
4" CONCRETE SLAB W/ G'%G " -W 1.4 X
6"X6 " -W 1.4 X 1.4 @
can
1.4 @ MID -DEPTH OF SLAB ON
2"
MID -DEPTH OF SLAB OVER 6
z
SOIL. (BROOM
EDGE OF SLAB
MIL. VAPOR BARRIER ON \
g
FINISH)
_FEE: 0-0" -TYP.: REFER TO SITE
WELL COMPACTED SOIL. (SEE \
5ECTION3 FOR ADDITIONAL
CJ
19
_
- - -
- - - - - - - -- _ _
FEE: 0' -0" -TYP.: REFER TO SITE
x x x-
itJ PLAN FOR NVGD ELEVATION
DATA) ..
- - -x-
%e" per Ft : SLOPE AWAY
PLAN FOR NVGD ELEVATION
SLAB RENFORCING
CJ
FROM STRUCTURE
6 ML. VAPOR BARRIER OVER----
"-
-" x x x x-
TE: SEE 5 -1 5CHED. FOR
ADDT. INFO.
-'
WELL CCMPACTED BASE - SEE
;'� �•,
COMPACTION NOTES 5HT. 51
WF- I G: SEE 5 -1 5CHED. FOR
WF- I G: SEE 5-1 5CH ED. FOR
; ; • ` j '
•
DT I FO
ADDT INFO
'
1VA2 Typical Section B /A2 Section Throuoh Porch
SCALE: 3/4": P -0"
SCALE: 3/4' : V -0"
,�,TE: 10 0
.gip SOU T ii vAIAIVII
B,_JILDING DEP`i*.
S, - `tJCTU1 i- ECTIONI
*PROVED B`f: - ........,.
=,3
ATTIC VENTILATION BASED ON 2004 FBC 8806.2 vjz:
ATTIC AREA: 1326 5F @ (1/ 150) = 9 SF RECD.
LOWER: SAVE VENTS (022) @ .5 SF EA. = 18 TOTAL
2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS
THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS
PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN
80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE
UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE SAVE OR CORNICE VENTS
WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY SAVE OR CORNICE VENTS. AS AN
ALTERNATIVE, THE NET FREE CR055- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A
VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM IS INSTALLED ON THE
WARM 51DE OF THE CEILING.
Roof Plan
SCALE: 1/8" : P -0"
DATE: 10 -11 -08
PROJECT: _ New 1 Sty SFR
ADDRESS: 60" SW 64 TR
South Mlaml, Florida
OWNER: Habitat for Humanity
Anne Manning, Exec. Director
305 670 -2224
REVISIONS: 111-13-09
TM
A11
/%/ %0
r�.D%
SEAL
FEB 1'7 2008
ARCHITECT OF RECORD:
PAUL W. BUCKLER
AR13708
muwr r OF GREATER NMI, IMO.
a �',���„
i
38COMW22AYEIIOE
IMMIMb FLORIDA 33142
305. 838-0192
AGEMT: AMME WHIN, EMECOTM DIRECTOR
ARCHITECTURAL
20111