08-1252-001SI2 PREFABRICATED WOOD -' TRU55E5 @ 24' GC TRU55 CONFIGURATION BY TRUSS MANUFACTURER. TRU55 SHOP DWG's TO BE SUBMITTED FOR BOTH THE BLDG. DEPARTMENT`S APPROVAL. AND PROJECT ARCHITECT'S APPROVAL FOR ALL GENERAL CONDITIONS REFER TO SECTION 6/A2 @ RIGHT x _ x x- I I X 0 iu LLJ 0 0 N f�.t Floor Plan _ _ HGT. OF RIDGE 14' 1 1 ° AFF -TYP. WOOD TRUSSES TO COMPLY W/ - - - - 2004 FBC 2319.17, INCLUDING 2319.17.2.1 PREFABRICATED WOOD HURRICANE STRAP SEE STRUCTURAL TRUSSES SHALL BE DESIGNED BY A HURRICANE TYPICAL PROFESSIONAL ENGINEER...AND FABRICATED IN ACCORDANCE WITH THE NATIONAL STANDARD FOR 8806.3 VENT CLEARANCE. METAL PLATE CONNECTED WOOD INSULATION SHALL NOT BLOCK THE TRUSS CONSTRUCTION OF THE FREE FLOW OF AIR. A MINIMUM OF A TRU55 PLATE INSTITUTE UPI -95). I IN SPACE SHALL BE PROVIDED THE TRU55 SYSTEM DESIGNER... BETWEEN THE INSULATION AND THE 5HALL PREPARE THE TRUSS SYSTEM ROOF SHEATHING AT THE LOCATION SHOP DRAWINGS SUCH SHOP OF THE VENT. DRAWINGS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL FOR REVIEW Cam' AND APPROVAL nnn T.0.13: 8' -2" AFF TYP. R-30 BATT INSULATION IN - - - CEILING -TYP. I X2 (min.) PT CONT. -TYP. • TB TB: SEE 5-1 PROVIDE 2#5 CORNER BARS w/ 30° LEGS @ EA. CORNER INTERSECTIONS. SEE 5CHED. 5HT. 51 FOR ADDT. INFO. 1 /2' GWB ON IX3 STRIPPING @I G' O /C- TYPICAL. ALL INTERIOR FINISHES TO BE SELECTED BY OWNER 1/2' GWB ON I X2 PT FURRING w/ R-4.1 FOIL OR RIGID BD.TYP. NO.9 GAUGE HORT. JOIN' REINF. @ 8" CMU WAIL: ! #5 @ 40" QC VERT. I G' GC. (LADDER TYPE) EXTEND MIN. IN BLOCK CELJ5 FILLED W/ CONCRETE 4' INTO TC GROUT * NO.9 GAUGE HOKT, JOINT REINF. @ I G' GC. VERT (LADDER TYPE) EXTEND MIN. 4" INTO TC VINYL. FLOOR TILE MN15H 5/8' ROOF SHEATHING -SEE 5-1 SHEET FOR ADDT. INFO. RB-1: SEE 5-1 5CHED. FOR • 24'± TYP 01 ADDT.INFO. STANDARD HOOK ORCH CEILING NOTE: 518" CDX • PLYWOOD W! 8d COMMON NAILS @ 4' 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE 2X VERT. MEMBERS @ 24" 0/C ALONG PLYWOOD EDGES W/ PAPER-BACKED MTL. LATH W/ STUCCO FINISH. HAND APPLIED STUCCO FINISH (1/2' MIN.) LIGHT TEXTURFJPAINT FINISH 4' CONCRETE SLAB W/ U 67041.4X 1.4@ MID -DEPTH OF SLAB OVER 6 z MIL. VAPOR BARRIER ON WELL - COMPACTED SOIL. (SEE _FF_E: 0'-0" 1YF'.: REFER TO SITE C1 PLAN FOR NVGD ELEVATION SECTIONS FOR ADDITIONAL - - `A SLAB REINFORCING DATA) 6 ML VAPOR BARRIER OVER WELL COMPACTED BASE - SEE \ \� \ \\\ j \ - / COMPACTION NOTES 5HT. 51 ical Section WF- 16: SEE S -1 5CHED. FOR WF- 16: SEE S-1 5CHED. FOR - ADDT. INFO. ADDT.INFO. • B /A2 Section Through Porch SCALE: 314": 1'-9 4' CONCRETE SLAB W/ 6"X6' -W 1.4 X 1.4 @ MID -DEPTH OF SLAB ON WELL - COMPACTED SOIL. (BROOM FINISH) Ya' pa Ft : SLOPE AWAY, - FROM STRUCTURE x x x x x x- 8.. SCALE: 1/4' : 1' -0' ROOFING NOTE: (SEPARATE PERMIT REQUIRED) GAF TIMBERLINE 30 SHINGLE NOA #OG -121 1.02 OR EQ. #30 w/ TIN CAP RS NAIL5 : 6' GC @ LAPS t 12' CJC FIELD ASPHALT SHINGLES w/ 6 R5 NAILS/SHINGLE (1) @ EA. CORNER 4 (2) @ EA/ TAB SEPARATION- TYP. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL TRU55 CONDITION 90 DEGREE CUT FASCIA ASSEMBLY: I X2 # 2X6 P.T. MIN.W/ (2) 1 Gd NAILS �r T_O.8: 8-2" AFF TYP. SOFFIT: ASPHALT PAPER-BACKED MTL RIB LATH USE I -I /4' TIN CAP @ 6' a/c w/ MIN. I/2' STUCCO FIN. TYPICAL SOFFIT VENT: 4722" AL SCREEN VENT COMPLY W/ F13C 20048806. I # 806.2 (FOR AREA SEE ROOF PLAN) 8806. I VENTILATION REQUIRED. ENCLOSED ATTICS AND ENCLOSED RAFTER 5PACE5 FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CRO55 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE PROVIDED W/ CORROSION- RESISTANT WIRE MESH, w/ 118 IN MIN. TO V4 IN MAX. OPENINGS. 2' EDGE OF SLAB _ FEE: 0-0' =TYP.: REEFER TO 51TE PLAN FOR NVGD ELEVATION TE:5EE5 -1 5CHED. FOR ADDT.INFO. SCALE: 3/4" : 1' -0' SECONDARY MEANS OF ESCAPE: AN OUTSIDE �- WINDOW OR DOOR OPERABLE FROM THE INSIDE W/0 THE USE OF TOOLS, KEYS, OR SPECIAL EFFORT AND PROVIDING A CLEAR OPENING OF NOT LESS THAN 20 IN. IN WIDTH t 24 IN. IN HEIGHT, AND 5.0 SF (GROUND FL) # 5.7 SF (SECOND Fu IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44 IN. a� ABOVE THE FLOOR.. 2004 FBC 8310 � R31 I 8307.2 BATHTUB AND SHOWER SPACES. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LESS THAN 6 FTA13OVE THE Door Schedule NOTE: ALL JAMB5, TRIM AND MOLDINGS TO BE WOOD, PAIN;" GRADE^' # ROOM 5 1 2 E 5 T Y L E TYPE N0TE5 D -I ENTRY 3Gx80x1 -3/4 MTL INSUL L.G. M15SILE IMPACT -5GL. DWKEY EGRESS D -2 EXT. LAUNDRY 3Gx80x1 -3/4 MTL IN5UL. LG. M1551L.E IMPACT -5GL. DUEY _rt D -3 AC CL05ET 3 2x 1 -3/8 FULL LOUVER BWOLD VERIFY DOOR STYLE w/ OWNER D-4 LAUNDRY 32x8Ox1 -3/8 SOLID SWING - PASSAGE PAINT FINISH D -5 BEDROOM B 32x80x 1 -3/8 5OUD SWING - PRIVACY COMPLY HAZARDOUS GLAZING CAr,11- - - D -6 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD POL. CHROME HRDWR VERIFY 5TY1Z'w /OWNER D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER BI -FOLD POL. CHROME HRDWR VERIFY 5TYLZ w / -OmiER D-8 BATHROOM 32x8& 1 -3/8 50UD SWING - PRIVACY 2004 FBC R322. 1.1 ACCF551131UTY D -9 CL05ET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD PAINT FINISH D 10 BEDROOM A I 32x80x 1 -3/8 1 SOLID 5MNG- PRIVACY COMPLY HAZARDOUS GLAZING CAT. II D I I CLOSET I 48x80x 1 -3/8 1 FULL LOUVER I DBL. BI -FOLD COMPLY HAZARDOUS GLAZING CAT. II ALL BUILDINGS SHALL HAVE A J PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS E5TA5U5HED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRECON5TRUCTION 501L TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMTTE5. A CERTIFICATE OF COMPLIANCE SHALL BE 155UED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS t0 RECEIVED A COMPLETE TREA w Schedule (SEE GENERAL NOTES° FOR WINDOW AND DOOR DATA.) FLOOR. "'R322.1.1 ALL NEW SINGLE - FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL SIZE DE51GN AND CONSTRUCTION SHALL COMPLY PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED N0TE5 WITH THE FLORIDA BUILDING CODE RESIDENTIAL ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF,ONLY A TOILET ROOM 15 37 x 63 2004 PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. EGRESS ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR R.311.4.1 EXIT DOOR REQUIRED. NOT LESS THAN ONE EXIT DOOR CONFORMING TO TH15 SECTION SHALL BE PROVIDED 37 x 63 AL SGL HUNQ25 R807. X330' DIRECT LE NDWEWNG W-2 NING SHIALL NOT E LE55 THAN 22'X PORTIONS Of THE TORTE EXTERIOR WITHOUT WITHOUT REQUIRING TRAVEL ROUGH A GARAGE. ACCE55 TO AL 5GL HUNG/23 AND SHALL BE LOCATED IN A HALLWAY OR HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THIS SECTION SHALL BE BY A RAMP IN ACCORDANCE 4e-0" LIVING ROOM OTHER READILY ACCESSIBLE LOCATION. A 30" WITH SECTION R31 1.6 OR A 5TAIRWAY IN ACCORDANCE WITH SECTION R31 1.5 . TINTED MINIMUM UNOBSTRUCTED HEADROOM IN THE R311.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT QOOR SHALL BE A SIDE - HINGED DOOR NOT LESS THAN 3 FT IN 37 x 63 AL 5GL HUNC425 ATTIC SPACE SHALL BE PROVIDED AT 50ME WIDTH AND 6 FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM FORCE OF 300 Ibs. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE 5TANDARD5 SET POINT ABOVE THE ACCE55 OPENING. DIMENSIONS. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS / FBC R4410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE R311.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. LAW50N INDU5TRIE5/WHITE ALUMINUM/UGHT GRAY TINT GLASS OR EQUAL. G. ALL BEDROOMS SHAM HAVE A SECONDARY 48'X96 "X4° CONC. SLAB w/ BROOM FINISH -SEE EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS I5 LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER .: S I FOR ADD INFORMATION THAN THE REQUIRED EXIT DOOR, A LANDING 15 NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF THE FLOOR OR LANDING AT EXTERIOR DOORS RETIRED BY SECTION R311.4.1 SHALL NOT BE REQUIRED TO COMPLY 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE 8310.4 (PARTIAL) THE TEMPORARY INSTALLATION OR CLOSURE OF STORM WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R311.5.3. f.. SHUTTERS, PANELS, AND OTHER APPROVED EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE _' :�: •. HURRICANE PROTECTION DEVICES SHALL BE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE PERMITTED ON EMERGENCY ESCAPE AND LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED, EVERY LANDING SHALL HAVE A RESCUE OPENINGS DURING THE THREAT OF A STORM. SUCH DEVICES SHALL NOT BE MINIMUM DIMENSION OF 36 IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL o REQUIRED TO COMPLY WITH THE OPERATIONAL EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRE55 15 TO BE MADE WITHOUT THE USE s CONSTRAINTS OF SECTION 8310.1.4. WHILE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. z SUCH PROTECTION IS PROVIDED, LEAST ONE MEANS OF ESCAPE FROM THE DWELLING OR R3 10.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE U DWELLING UNIT SHALL. BE PROVIDED. THE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY FINISHED WITH A NONABSORBENT MEANS OF ESCAPE SHALL BE WITHIN THE FIRST SHALL HAVE A 5ILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR, THE NET CLEAR OPENING DIMENSIONS FLOOR OF THE DWELLING OR DWELLING UNIT AND SHAD_ NOT BE LOCATED WITHIN A GARAGE REQUIRED BY TH15 SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE WITHOUT A SIDE HINGED. DOOR LEADING OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED SILL HEIGHT BELOW THE DIRECTLY TO THE EXTERIOF, OCCUPANTS IN ANY ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 '-R3-10.1 NOT LE55 THAN 6 FEET (1829 PART OF THE DWELLING OR DWELLING UNIT i ],MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET SHALL BE ABLE TO ACCESS THE MEANS OF ESCAPE WITHOUT PASSING THROUGH A _ CIFAR OPENING OF'5' 7 SF. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 5F LOCKABLE DOOR NOT UNDER THEIR CONTROL. R31 0.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN. 8310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. OR 2 1/4' NAILS @ MAX AIC SLAB TO BESET @FINISH FLOOR ELEVATION 8310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE CUT 3 ;' INSIDE OF THE ROOM WITHOUT THE USE OF KEY5 OR TOOLS. 84409.13.5 (8320.1) TERMITE PROTECTION. ALL BUILDINGS SHALL HAVE A J PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS E5TA5U5HED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED WITH RESPECT TO PRECON5TRUCTION 501L TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMTTE5. A CERTIFICATE OF COMPLIANCE SHALL BE 155UED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS t0 RECEIVED A COMPLETE TREA w Schedule (SEE GENERAL NOTES° FOR WINDOW AND DOOR DATA.) r M FOO SIZE STYLE GLAZING N0TE5 8303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED M -A 37 x 63 AL 5GL HUNG/25 TINTED EGRESS ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR M -B 37 x 63 AL SGL HUNQ25 TINTED EGRESS W-2 Ic1 te,0 tj 37 x 38 3/8 AL 5GL HUNG/23 TINTED -. _ ...: W-3 LIVING ROOM 37 x 63 AL SGL HUNG125 TINTED W-3 DINING ROOM 37 x 63 AL 5GL HUNC425 TINTED FORCE OF 300 Ibs. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE 5TANDARD5 SET FORTH IN THE CURRENT BLDG. CODE.- HINGES ON EXTERIOR OUT SWING DOORS SHALL HAVE NON- REMOVAABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS / FBC R4410.2 IMPACT INTENT FOR THE _ PREVENTION OF SUBTERRANEAN TERMITES. General Door & Window Notes ( SEE ELEVATIONS FOR WIND PRE55URE5) TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA 8303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED DEPARTMENT OF AGRICULTURE AND CONSUMER WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 5F, ONE -HALF OF WHICH MUST BE OPENABLE. SERVICES." EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING INDOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, 5AUNA5, STEAM ROOMS, BATHTUBS AND SHOWERS. GLAZING IN ANY PART OF A BUILDING WALL ENCL05ING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LESS THAN 60 IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING LTEM5:- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY -OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 P05515LE KEY CHANGES OR LOCKING AUXIUARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ibs. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE 5TANDARD5 SET FORTH IN THE CURRENT BLDG. CODE.- HINGES ON EXTERIOR OUT SWING DOORS SHALL HAVE NON- REMOVAABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS / FBC R4410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/UGHT GRAY TINT GLASS OR EQUAL. G. ALL BEDROOMS SHAM HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.S.ALL NEW EXTERIOR DOORS * WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT SWING DOORS SHALL HAVE NON - REMOVABLE PINS. ATTIC VENILATION BASED ON 2004 FBC 8806.2 WOOD TRUSSES ) } ATTACH PAKTJTI0N5 TO CEIUNG w STRi'P"dr-,OK P'Q;/iDE 2X4 BLOCKING i - C0 NOT A7ACH PARTITIONS DIRECTLY TO TRU55 CHORDS I X3 WB. STRIPPING @ I G' 0/C 84409.5. 1'- 15 WALL HUNG FIXTURES. - 51 UUS IN ESFAkiNG-WALLS, EXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURE5 AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN 16 INCHES (406 MM) ON CENTER OR, NOT LESS THAN 2 X 6, WHERE SPACED NOT MORE THAN 24 INCHES (6 10 MM) ON CENTER. 2X4 WOOD STUDS @ 16' 0/C w/ 1 /2" GWB EA. SIDE (USE 1/2' CEMENTITUOUS BD IN WET AREAS) (USE 1/2' M.R. GWB IN BATH AREA5) 8307.2 BATHTUB AND SHOWER SPACES. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE m o BATHTUBS WITH INSTALLED z SHOWER HEADS AND IN SHOWER z COMPARTMENTS SHALL BE U FINISHED WITH A NONABSORBENT o SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A HEIGHT OF NOT LE55 THAN 6 FEET (1829 MM) ABOVE THE FLOOR. USE PT 2X4 @ BOTTOM PLATE w/ 2- i 4' POWDER DRIVEN OR 2 1/4' NAILS @ MAX CUT 3 ;' CONCRETE FLOOR SLAB 0/A2 ft interior Partition ET].5 ATTIC AREA: 1326 SF @ (1 /150) = 9 5F REGD. LOWER: SAVE VENTS (022) @ .5 5F EA. = 18 TOTAL 2004 F13C 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LESS THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA IS PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA IS PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE SAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY SAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CRO55- VEN11LATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan SCALE: 1 /8": 1' -0" z ILJ ME-: 2" FROM EDI 3/16 "X 2 -1h MASONRY ANCHORS M EMBED DEPT 1- 1/2"- TYP. o °- I X4 P.T. ALL AROUND OP'G. I X P.T. BUCK AROUND OP'G. COMPLY w/ FBR RG13.G.1.1 FILLED CELUCONC. TYP. ALL SIDES SEE 5 -1 FOR LOC.5 " OMPLY w/ FBC 24407.4.2.2.8 NTERIOR 51DE WINDOW FASTEN06- PMR,TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OP ggir G. 1 /2" GWB on I X2 PT ' @ 161 0 /C-TYP. TW. window & Door iamb Detail N.T.S. CITY OF SOUTH MIAMI BUILDING DEPT. DATE: 02 -04 -08 STRUCTV SECTION PROJECT: New 1 Sty SFR ADDRESS: 6065 SW 64 TR South Miami, FL , VPROVED BY: PWNER: Habitat for Humanity ,, Anne Manning, Exec. Director 3058702224 REVISIONS: ( '( Io,S�f ° �"$6AL Ica V +, p L ' > it H 9 - ARCHITECTURAL -2 OF 3