09-195-0010 in - - - -- -- 40' -0" 12' -3" _ _ 7-2" _ NC 5IA5 TO BE SET FINISH FLOOR 48 X96 X4 CONC. SLAB EUN @ w/ BROOM FINISH -5EE S 1 ., ELEV TION FOR ADDT' INFORMATION A . j WI a " EGRESS - O O -- - - - - -- ° BEDROOM 1 O O LAONOfl 0 4" - D -6 4" v 4° 12' -5' 2' -10" _ _ _ 9' -4" 2' -0" [E] NOTE: ALL BEDROOMS SHALL HAVE= KITCHEN W M A SECONDARY MEANS OF EGRESS. _- -- 0] APPLIANCES ARE NOT A PART OF THIS PERMIT PANTRY ! PA55 THRU o i ao cv I 2' -6" 2' -8" 3' -G" 3' -4" DINING C� F.F.E.: G-O" T (FOR N.G.V.D• SEE SITE PLAN) L.G. MISSILE IMPACT DOOR COMPLIES AS POST STORM EGRESS SEE FBC R 310.4 Ii 4" LNING EGRESS 8' -6" 0� 'I SECONDARY MEANS OF ESCAPE: AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE s W10 THE USE OF TOOLS, KEYS, OR SPECIAL 4" + EFFORT AND PROVIDING A CLEAR OPENING OF 8'-6" ' •- 2' -1 " �/� S -10" �. NOT LE55 THAN 20 IN. IN WIDTH It 24 INS IN 8„ H - _ HEIGHT, AND 5.0 5F (GROUND FL) t 5.7 SF i 4" I (SECOND FL) IN AREA. THE BOTTOM OF THE _ -_ _- ___ =_,{ %' BATH °v ABOVE THE FLOOR. 2004 FBC 8310 t R31 I EVERY BATHROOM DOOR SHALL BE DE51GNED v ® i - -� T `O A 4" 4' 2' -1 " r' 3'- 1 0" 4" 2' -2 112" 4' -9± o 8307.2 BATHTUB AND SHOWER SPACES. BATHTUB AND SHOWER FLOORS AND WALLS JLM� d U ABOVE BATHTUBS WITH INSTALLED SHOWER I m HEADS AND IN SHOWER COMPARTMENTS SHALL MT4 ® BEDROOM 1 BE FINISHED WITH A NONABSORBENT SURFACE. ;OAHU'. ! SUCH WALL SURFACES SHALL EXTEND TO A " "'8322.1.1 ALL NEW SINGLE - FAMILY HOUSES DUPLEXES, TRIPLEXES, CONDOMINIUMS AND HEIGHT OF NOT LE55 THAN G FTABOVE THE �o TOWNHOUSES SHALL PROVIDE AT LEAST ONE 8" 4' -2" ' "f-'' g' 2" � � 9' -2" I 4' -2" BATHROOM, LOCATED WITH MAXIMUM - - - -'- - - -- -- - P0551BLE PRIVACY, WHERE BATHROOMS ARE 4" CONC. SLAB w/ I rNr, PROVIDED ON HABITABLE GRADE LEVELS, WITH BROOM FINISH - _ A DOOR THAT HAS A 29 -INCH (737 MM) SEE 51 FOR ADDT. PORCH CLEAR OPENING. HOWEVER, IF ONLY A TOILET INFORMATION ( F.F.E.: -0' -6" ROOM 15 PROVIDED AT GRADE LEVEL, SUCH "' TOILET ROOMS SHALL HAVE A CLEAR OPENING P.I.P. CONC. COL. i "'i OF NOT LE55 THAN 29 INCHES (737 MM). TYP. OF 3 I EGRESS k- - - +- - 8 y - - -- - - - n -- - - - - --' 8 5' 8" 8' -5" 8' -6' 8" -- - - -- - - f- - -- - -- 27 -4 Floor Plan--- - - -___ 40'-0" 0 MEANS OF ESCAPE SHALL BE WITHIN THE FIRST 2 FLOOR OF THE DWELLING OR DWELLING UNIT - AND SHALL NOT BE LOCATED WITHIN A GARAGE ' WITHOUT A 51DE HINGED DOOR LEADING DIRECTLY TO THE EXTERIOR. OCCUPANTS IN ANY PART OF THE DWELLING OR DWELLING UNIT SHALL BE ABLE TO ACCESS THE MEANS OF ESCAPE WITHOUT PA551NG THROUGH A m LOCKABLE DOOR NOT UNDER THEIR CONTROL. 84409.13.5 (8320.1) TERMITE PROTECTION. ALL BUILDINGS SHALL HAVE A PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES. THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES SHALL BE DEEMED AS APPROVED �o WITH RESPECT TO PRECON5TRUCTION SOIL TREATMENT FOR PROTECTION AGAINST SUBTERRANEAN TERMITES. A CERTIFICATE OF 8" 5' -8" 5' -8" 8" COMPLIANCE SHALL BE 155UED TO THE - - - BUILDING DEPARTMENT BY THE LICENSED PEST 12' -8" CONTROL COMPANY THAT CONTAINS THE -- - - - -� -- - - -- - - - -- - -� FOLLOWING 5TATEMENT:'THE BUILDING HAS -- RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. _ TREATMENT 15 IN ACCORDANCE WITH RULES SCALE: I /4" : I' -0" AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 51EFOR MORE IN M , FLORIDA BUILDING CODE 2004 RESIDENTIAL -- ROOFING NOTE: SEPARATE PERMIT REQUIRED) GAF Timberline 3 5hmgle NOA #06 -121 1.02 OR EQ. 12 - #30 W/ TIN CAP NAILS: G" c1c@ LAPS # 12" cic Field 5 ASPHALT SHINGLES wl 6 NAILS/SHINGLE (I) @ EA. CORNER 4 (2) @ EA/ TAB SEPARATION - TYP. TRU55 CONFIGURATfOK `� -� - 5/8" ROOF SHEATHING- WOOD TRUSSES TO COMPLY WI FBC 2319. 7 INCLUDING 2319.17.2.1 BY TRUSS MANUFACTURER. - �, SEE 5 -1 SHEET FOR ADDT. INFO. PREFABRICATED WOOD TRU55 LL BE DESIGNED BY A PROFESSIONAL ENGI MFR. TRUSS SHOP DWG's �\ AND FABRICATED IN ACCORDAN H THE NATION L STANDARD FOR METAL F TO BE SUBMITTED FOR BOTH\ - HURRICANE STRAP CONNECTED WOOD TRU55 CON ION OF TH T U55 PLATE INSTITUTE ((PI- THE BLDG. DEPARTMENTS APPROVAL SEE STRUCTURAL DWG.5 THE TRU55 SYSTEM DESIGNER... L PREPARE T E TRU55 SYSTEM SHOP DV AND PROJECT ARCHITECT'S APPROVAL ; TYPICAL SUCH SHOP DRAWINGS SHALL B MITTED TO BUILDING OFFICIAL FOR RL 90 DEGREE CUT AND APPROVAL. FASCIA ASSEMBLY: 24" MAX 24' MAX -TYP. PREFABRICATE WOOD TRUSSES @ 24' QC - ' , I X2 4 2X6 P.T. MIN. WI 2X6 P.T. CONT. W/ 1 12" DIA. MAINTAIN I' MIN. CLEAR (FBC 5806.3) / (2) 1 Gd NAIL5 EA. TRU55 WEDGE BOLTS @ 24' UC R -30 GATT INSULATION - -- ( ( ; ( `) (� } TOP OF T. B.: 8' -2' AFF 2X6 BLK'G. FOR - IN CEILING TYP - CEILING STRIPPING 112' GWB ON IX3 STRIPPING - -- -; - @ I G" OIC- TYPICAL I SOFFIT: ASPHALT PAPER-BACKED ALL INTERIOR FINISHES 2 -0 MTL. RIB LATH USE 1 -1 /4 TIN CAP @ Colt; IX2 (min.) PT TO BE SELECTED BY OWNER w/ MIN. 112' STUCCO FIN. - TYPICAL CONT. -TYP. SOFFIT VENT: 4"X22" AL. SCREEN VENT TB REINF. I X2 (min.) PT CONT. -TYP. - - - I COMPLY WI FBC 2004 8806.14 806.2 (AREA SEE ROOF PLAN) SEE 5-1 SCHED. FOR TB REINF. - SEE 5 -1 SCHED. FOR ADDT. INFO. 2 #5 CORNER BARS w/ 30" LEGS @ EA. CORNER 4 INTERSECTIONS. No. 9 GAUGE HORT. JOINT REINF. - -- - @ I G' C/C. (LADDER TYPE) extend min. 4" into TC IN 8806. I VENTILATION REQUIRED. ADDT. INFO. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CRO55 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION - RESISTANT WIRE MESH, WIT H I / 8 INCH (3.2 MM) MINIMUM TO %4 INCH (6.4 MM) MAXIMUM OPENINGS. #5 @ 48' QC VERT. IN BLOCK CELLS FILLED W1 CONCRETE GROUT 1/2' GWB ON I X2 PT FURRING - - ---{ @ 16' C /C- TYPICAL I HAND APPLIED STUCCO FINISH (1 /2" MIN.) WALL INSULATION - - -- -- - -- - LIGHT TFXfUREIPAINT FIN15H R -4.1 TYP. NEW 4" CONC. 51AB -- - -- - - - REINF. Wl 6X6 WI A X W1.4 W.W.M. SEE FOUND. PLAN 5 -1 FOR ADDT. INFO LU E VINYL FLOOR TILE FINISH I CJ - -x -- -x - - -- - - -- x - - 1 6 ML. VAPOR BARRIER - -I --�' WELL- COMPACTED BASE r-• SEE COMPACTION NOTES 51 ir = I SEE 5 -1 SCHED. FOR ADD7.INFO. MR: Section Thm Exterior Wall 1 /2" GWB ON IX2 PT FURRING @ 16" C /C- TYPICAL WALL INSULATION: R-4.1 FOIL OR RIGID BD.TYP. FBC B 310: OCCUPANCY R -3 SINGLE FAMILY (I STORY) 12 � 15 `- PORCH CEILING NOTE: 518" CDX PLYWOOD W/ 8d COMMON NAILS @ 4" 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE VERT. MEMBERS @ 24' 0/C ALONG STANDARD PLYWOOD EDGES W/ PAPER - BACKED HOOK MTL. LATH W/ STUCCO FINISH. 8' CMU WALL no. 9 GAUGE HORT. JOINT REINF. @ I G' UC. (LADDER TYPE) extend min. 4' into TC #5 @ 48" UC VERT. IN BLOCK CELLS FILLED WI CONCRETE GROUT 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 SECONDARY MEANS OF ESCAPE: AN OUTSIDE WINDOW OR DOOR OPERABLE FROM THE INSIDE W10 THE USE OF TOOLS, KEYS, OR SPECIAL EFFORT AND PROVIDING A CLEAR OPENING OF NOT LE55 THAN 20 IN. IN WIDTH It 24 INS IN 8„ H HEIGHT, AND 5.0 5F (GROUND FL) t 5.7 SF (SECOND FL) IN AREA. THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44 IN. ABOVE THE FLOOR. 2004 FBC 8310 t R31 I EVERY BATHROOM DOOR SHALL BE DE51GNED TO ALLOW OPENING FROM THE OUTSIDE DURING -� T `O A AN EMERGENCY WHEN LOCKED. 8307.2 BATHTUB AND SHOWER SPACES. BATHTUB AND SHOWER FLOORS AND WALLS ABOVE BATHTUBS WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NONABSORBENT SURFACE. SUCH WALL SURFACES SHALL EXTEND TO A - H HEIGHT OF NOT LE55 THAN G FTABOVE THE FLOOR. - 8807.1 ATTIC ACCESS. THE ROUGH- FRAMED OPENING SHALL NOT BE LE55 THAN 22"X 30" AND SHALL BE LOCATED IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. A 30" MINIMUM UNOBSTRUCTED HEADROOM IN THE ATTIC SPACE SHALL BE PROVIDED AT 50ME POINT ABOVE THE ACCESS OPENING. `0 D DESIGN AND CONSTRUCTION SHALL COMPLY CD W WITH THE FLORIDA BUILDING CODE RESIDENTIAL 2004 HAZARDOUS LOCATION: FBC 2405.2.1 #2 PROVIDE TEMP. OR LAM. GLAZING WITHIN 3G" OF TUB /5HWR. ENCL.- TYPICAL M 8 8310.4 (PARTIAL,' THE TEMPORARY INSTALLATION OR CLOSURE OF STORM SHUTTERS, PANELS, AND OTHER APPROVED HURRICANE PROTECTION DEVICES SHALL BE PERMITTED ON EMERGENCY ESCAPE AND RESCUE OPENINGS DURING THE THREAT OF A STORM. SUCH DEVICES SHALL NOT BE REQUIRED TO COMPLY WITH THE OPERATIONAL CONSTRAINTS OF SECTION 8310.1.4 . WHILE SUCH PROTECTION 15 PROVIDED, AT LEAST ONE MEANS OF ESCAPE FROM THE DWELLING OR DWELLING UNIT SHALL BE PROVIDED. THE SUBTERRANEAN TERMITES. A CERTIFICATE OF 8" 5' -8" 5' -8" 8" COMPLIANCE SHALL BE 155UED TO THE - - - BUILDING DEPARTMENT BY THE LICENSED PEST 12' -8" CONTROL COMPANY THAT CONTAINS THE -- - - - -� -- - - -- - - - -- - -� FOLLOWING 5TATEMENT:'THE BUILDING HAS -- RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. _ TREATMENT 15 IN ACCORDANCE WITH RULES SCALE: I /4" : I' -0" AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." 51EFOR MORE IN M , FLORIDA BUILDING CODE 2004 RESIDENTIAL -- ROOFING NOTE: SEPARATE PERMIT REQUIRED) GAF Timberline 3 5hmgle NOA #06 -121 1.02 OR EQ. 12 - #30 W/ TIN CAP NAILS: G" c1c@ LAPS # 12" cic Field 5 ASPHALT SHINGLES wl 6 NAILS/SHINGLE (I) @ EA. CORNER 4 (2) @ EA/ TAB SEPARATION - TYP. TRU55 CONFIGURATfOK `� -� - 5/8" ROOF SHEATHING- WOOD TRUSSES TO COMPLY WI FBC 2319. 7 INCLUDING 2319.17.2.1 BY TRUSS MANUFACTURER. - �, SEE 5 -1 SHEET FOR ADDT. INFO. PREFABRICATED WOOD TRU55 LL BE DESIGNED BY A PROFESSIONAL ENGI MFR. TRUSS SHOP DWG's �\ AND FABRICATED IN ACCORDAN H THE NATION L STANDARD FOR METAL F TO BE SUBMITTED FOR BOTH\ - HURRICANE STRAP CONNECTED WOOD TRU55 CON ION OF TH T U55 PLATE INSTITUTE ((PI- THE BLDG. DEPARTMENTS APPROVAL SEE STRUCTURAL DWG.5 THE TRU55 SYSTEM DESIGNER... L PREPARE T E TRU55 SYSTEM SHOP DV AND PROJECT ARCHITECT'S APPROVAL ; TYPICAL SUCH SHOP DRAWINGS SHALL B MITTED TO BUILDING OFFICIAL FOR RL 90 DEGREE CUT AND APPROVAL. FASCIA ASSEMBLY: 24" MAX 24' MAX -TYP. PREFABRICATE WOOD TRUSSES @ 24' QC - ' , I X2 4 2X6 P.T. MIN. WI 2X6 P.T. CONT. W/ 1 12" DIA. MAINTAIN I' MIN. CLEAR (FBC 5806.3) / (2) 1 Gd NAIL5 EA. TRU55 WEDGE BOLTS @ 24' UC R -30 GATT INSULATION - -- ( ( ; ( `) (� } TOP OF T. B.: 8' -2' AFF 2X6 BLK'G. FOR - IN CEILING TYP - CEILING STRIPPING 112' GWB ON IX3 STRIPPING - -- -; - @ I G" OIC- TYPICAL I SOFFIT: ASPHALT PAPER-BACKED ALL INTERIOR FINISHES 2 -0 MTL. RIB LATH USE 1 -1 /4 TIN CAP @ Colt; IX2 (min.) PT TO BE SELECTED BY OWNER w/ MIN. 112' STUCCO FIN. - TYPICAL CONT. -TYP. SOFFIT VENT: 4"X22" AL. SCREEN VENT TB REINF. I X2 (min.) PT CONT. -TYP. - - - I COMPLY WI FBC 2004 8806.14 806.2 (AREA SEE ROOF PLAN) SEE 5-1 SCHED. FOR TB REINF. - SEE 5 -1 SCHED. FOR ADDT. INFO. 2 #5 CORNER BARS w/ 30" LEGS @ EA. CORNER 4 INTERSECTIONS. No. 9 GAUGE HORT. JOINT REINF. - -- - @ I G' C/C. (LADDER TYPE) extend min. 4" into TC IN 8806. I VENTILATION REQUIRED. ADDT. INFO. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CRO55 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION - RESISTANT WIRE MESH, WIT H I / 8 INCH (3.2 MM) MINIMUM TO %4 INCH (6.4 MM) MAXIMUM OPENINGS. #5 @ 48' QC VERT. IN BLOCK CELLS FILLED W1 CONCRETE GROUT 1/2' GWB ON I X2 PT FURRING - - ---{ @ 16' C /C- TYPICAL I HAND APPLIED STUCCO FINISH (1 /2" MIN.) WALL INSULATION - - -- -- - -- - LIGHT TFXfUREIPAINT FIN15H R -4.1 TYP. NEW 4" CONC. 51AB -- - -- - - - REINF. Wl 6X6 WI A X W1.4 W.W.M. SEE FOUND. PLAN 5 -1 FOR ADDT. INFO LU E VINYL FLOOR TILE FINISH I CJ - -x -- -x - - -- - - -- x - - 1 6 ML. VAPOR BARRIER - -I --�' WELL- COMPACTED BASE r-• SEE COMPACTION NOTES 51 ir = I SEE 5 -1 SCHED. FOR ADD7.INFO. MR: Section Thm Exterior Wall 1 /2" GWB ON IX2 PT FURRING @ 16" C /C- TYPICAL WALL INSULATION: R-4.1 FOIL OR RIGID BD.TYP. FBC B 310: OCCUPANCY R -3 SINGLE FAMILY (I STORY) 12 � 15 `- PORCH CEILING NOTE: 518" CDX PLYWOOD W/ 8d COMMON NAILS @ 4" 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE VERT. MEMBERS @ 24' 0/C ALONG STANDARD PLYWOOD EDGES W/ PAPER - BACKED HOOK MTL. LATH W/ STUCCO FINISH. 8' CMU WALL no. 9 GAUGE HORT. JOINT REINF. @ I G' UC. (LADDER TYPE) extend min. 4' into TC #5 @ 48" UC VERT. IN BLOCK CELLS FILLED WI CONCRETE GROUT 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 -- ROOFING NOTE: SEPARATE PERMIT REQUIRED) GAF Timberline 3 5hmgle NOA #06 -121 1.02 OR EQ. 12 - #30 W/ TIN CAP NAILS: G" c1c@ LAPS # 12" cic Field 5 ASPHALT SHINGLES wl 6 NAILS/SHINGLE (I) @ EA. CORNER 4 (2) @ EA/ TAB SEPARATION - TYP. TRU55 CONFIGURATfOK `� -� - 5/8" ROOF SHEATHING- WOOD TRUSSES TO COMPLY WI FBC 2319. 7 INCLUDING 2319.17.2.1 BY TRUSS MANUFACTURER. - �, SEE 5 -1 SHEET FOR ADDT. INFO. PREFABRICATED WOOD TRU55 LL BE DESIGNED BY A PROFESSIONAL ENGI MFR. TRUSS SHOP DWG's �\ AND FABRICATED IN ACCORDAN H THE NATION L STANDARD FOR METAL F TO BE SUBMITTED FOR BOTH\ - HURRICANE STRAP CONNECTED WOOD TRU55 CON ION OF TH T U55 PLATE INSTITUTE ((PI- THE BLDG. DEPARTMENTS APPROVAL SEE STRUCTURAL DWG.5 THE TRU55 SYSTEM DESIGNER... L PREPARE T E TRU55 SYSTEM SHOP DV AND PROJECT ARCHITECT'S APPROVAL ; TYPICAL SUCH SHOP DRAWINGS SHALL B MITTED TO BUILDING OFFICIAL FOR RL 90 DEGREE CUT AND APPROVAL. FASCIA ASSEMBLY: 24" MAX 24' MAX -TYP. PREFABRICATE WOOD TRUSSES @ 24' QC - ' , I X2 4 2X6 P.T. MIN. WI 2X6 P.T. CONT. W/ 1 12" DIA. MAINTAIN I' MIN. CLEAR (FBC 5806.3) / (2) 1 Gd NAIL5 EA. TRU55 WEDGE BOLTS @ 24' UC R -30 GATT INSULATION - -- ( ( ; ( `) (� } TOP OF T. B.: 8' -2' AFF 2X6 BLK'G. FOR - IN CEILING TYP - CEILING STRIPPING 112' GWB ON IX3 STRIPPING - -- -; - @ I G" OIC- TYPICAL I SOFFIT: ASPHALT PAPER-BACKED ALL INTERIOR FINISHES 2 -0 MTL. RIB LATH USE 1 -1 /4 TIN CAP @ Colt; IX2 (min.) PT TO BE SELECTED BY OWNER w/ MIN. 112' STUCCO FIN. - TYPICAL CONT. -TYP. SOFFIT VENT: 4"X22" AL. SCREEN VENT TB REINF. I X2 (min.) PT CONT. -TYP. - - - I COMPLY WI FBC 2004 8806.14 806.2 (AREA SEE ROOF PLAN) SEE 5-1 SCHED. FOR TB REINF. - SEE 5 -1 SCHED. FOR ADDT. INFO. 2 #5 CORNER BARS w/ 30" LEGS @ EA. CORNER 4 INTERSECTIONS. No. 9 GAUGE HORT. JOINT REINF. - -- - @ I G' C/C. (LADDER TYPE) extend min. 4" into TC IN 8806. I VENTILATION REQUIRED. ADDT. INFO. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CRO55 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION - RESISTANT WIRE MESH, WIT H I / 8 INCH (3.2 MM) MINIMUM TO %4 INCH (6.4 MM) MAXIMUM OPENINGS. #5 @ 48' QC VERT. IN BLOCK CELLS FILLED W1 CONCRETE GROUT 1/2' GWB ON I X2 PT FURRING - - ---{ @ 16' C /C- TYPICAL I HAND APPLIED STUCCO FINISH (1 /2" MIN.) WALL INSULATION - - -- -- - -- - LIGHT TFXfUREIPAINT FIN15H R -4.1 TYP. NEW 4" CONC. 51AB -- - -- - - - REINF. Wl 6X6 WI A X W1.4 W.W.M. SEE FOUND. PLAN 5 -1 FOR ADDT. INFO LU E VINYL FLOOR TILE FINISH I CJ - -x -- -x - - -- - - -- x - - 1 6 ML. VAPOR BARRIER - -I --�' WELL- COMPACTED BASE r-• SEE COMPACTION NOTES 51 ir = I SEE 5 -1 SCHED. FOR ADD7.INFO. MR: Section Thm Exterior Wall 1 /2" GWB ON IX2 PT FURRING @ 16" C /C- TYPICAL WALL INSULATION: R-4.1 FOIL OR RIGID BD.TYP. FBC B 310: OCCUPANCY R -3 SINGLE FAMILY (I STORY) 12 � 15 `- PORCH CEILING NOTE: 518" CDX PLYWOOD W/ 8d COMMON NAILS @ 4" 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE VERT. MEMBERS @ 24' 0/C ALONG STANDARD PLYWOOD EDGES W/ PAPER - BACKED HOOK MTL. LATH W/ STUCCO FINISH. 8' CMU WALL no. 9 GAUGE HORT. JOINT REINF. @ I G' UC. (LADDER TYPE) extend min. 4' into TC #5 @ 48" UC VERT. IN BLOCK CELLS FILLED WI CONCRETE GROUT 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 112' GWB ON IX3 STRIPPING - -- -; - @ I G" OIC- TYPICAL I SOFFIT: ASPHALT PAPER-BACKED ALL INTERIOR FINISHES 2 -0 MTL. RIB LATH USE 1 -1 /4 TIN CAP @ Colt; IX2 (min.) PT TO BE SELECTED BY OWNER w/ MIN. 112' STUCCO FIN. - TYPICAL CONT. -TYP. SOFFIT VENT: 4"X22" AL. SCREEN VENT TB REINF. I X2 (min.) PT CONT. -TYP. - - - I COMPLY WI FBC 2004 8806.14 806.2 (AREA SEE ROOF PLAN) SEE 5-1 SCHED. FOR TB REINF. - SEE 5 -1 SCHED. FOR ADDT. INFO. 2 #5 CORNER BARS w/ 30" LEGS @ EA. CORNER 4 INTERSECTIONS. No. 9 GAUGE HORT. JOINT REINF. - -- - @ I G' C/C. (LADDER TYPE) extend min. 4" into TC IN 8806. I VENTILATION REQUIRED. ADDT. INFO. ENCLOSED ATTICS AND ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF RAFTERS SHALL HAVE CRO55 VENTILATION FOR EACH SEPARATE SPACE BY VENTILATING OPENINGS PROTECTED AGAINST THE ENTRANCE OF RAIN. VENTILATING OPENINGS SHALL BE PROVIDED WITH CORROSION - RESISTANT WIRE MESH, WIT H I / 8 INCH (3.2 MM) MINIMUM TO %4 INCH (6.4 MM) MAXIMUM OPENINGS. #5 @ 48' QC VERT. IN BLOCK CELLS FILLED W1 CONCRETE GROUT 1/2' GWB ON I X2 PT FURRING - - ---{ @ 16' C /C- TYPICAL I HAND APPLIED STUCCO FINISH (1 /2" MIN.) WALL INSULATION - - -- -- - -- - LIGHT TFXfUREIPAINT FIN15H R -4.1 TYP. NEW 4" CONC. 51AB -- - -- - - - REINF. Wl 6X6 WI A X W1.4 W.W.M. SEE FOUND. PLAN 5 -1 FOR ADDT. INFO LU E VINYL FLOOR TILE FINISH I CJ - -x -- -x - - -- - - -- x - - 1 6 ML. VAPOR BARRIER - -I --�' WELL- COMPACTED BASE r-• SEE COMPACTION NOTES 51 ir = I SEE 5 -1 SCHED. FOR ADD7.INFO. MR: Section Thm Exterior Wall 1 /2" GWB ON IX2 PT FURRING @ 16" C /C- TYPICAL WALL INSULATION: R-4.1 FOIL OR RIGID BD.TYP. FBC B 310: OCCUPANCY R -3 SINGLE FAMILY (I STORY) 12 � 15 `- PORCH CEILING NOTE: 518" CDX PLYWOOD W/ 8d COMMON NAILS @ 4" 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE VERT. MEMBERS @ 24' 0/C ALONG STANDARD PLYWOOD EDGES W/ PAPER - BACKED HOOK MTL. LATH W/ STUCCO FINISH. 8' CMU WALL no. 9 GAUGE HORT. JOINT REINF. @ I G' UC. (LADDER TYPE) extend min. 4' into TC #5 @ 48" UC VERT. IN BLOCK CELLS FILLED WI CONCRETE GROUT 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 1 /2" GWB ON IX2 PT FURRING @ 16" C /C- TYPICAL WALL INSULATION: R-4.1 FOIL OR RIGID BD.TYP. FBC B 310: OCCUPANCY R -3 SINGLE FAMILY (I STORY) 12 � 15 `- PORCH CEILING NOTE: 518" CDX PLYWOOD W/ 8d COMMON NAILS @ 4" 0/C TO VERT. TRU55 MEMBERS. TRU55 MANUFACTURER TO PROVIDE VERT. MEMBERS @ 24' 0/C ALONG STANDARD PLYWOOD EDGES W/ PAPER - BACKED HOOK MTL. LATH W/ STUCCO FINISH. 8' CMU WALL no. 9 GAUGE HORT. JOINT REINF. @ I G' UC. (LADDER TYPE) extend min. 4' into TC #5 @ 48" UC VERT. IN BLOCK CELLS FILLED WI CONCRETE GROUT 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 2004 FBC 8806.2 MINIMUM AREA. THE TOTAL NET FREE VENTILATING AREA SHALL NOT BE LE55 THAN I TO 150 OF THE AREA OF THE SPACE VENTILATED EXCEPT THAT THE TOTAL AREA 15 PERMITTED TO BE REDUCED TO I TO 300, PROVIDED AT LEAST 50 PERCENT AND NOT MORE THAN 80 PERCENT OF THE REQUIRED VENTILATING AREA 15 PROVIDED BY VENTILATORS LOCATED IN THE UPPER PORTION OF THE SPACE TO BE VENTILATED AT LEAST 3 FT ABOVE EAVE OR CORNICE VENTS WITH THE BALANCE OF THE REQUIRED VENTILATION PROVIDED BY EAVE OR CORNICE VENTS. AS AN ALTERNATIVE, THE NET FREE CROSS- VENTILATION AREA MAY BE REDUCED TO I TO 300 WHEN A VAPOR BARRIER HAVING A TRANSMISSION RATE NOT EXCEEDING I PERM 15 INSTALLED ON THE WARM SIDE OF THE CEILING. Roof Plan RB- I: SEE 5-1 SCHED. FOR ADDT. INFO. 878' POURED CONC. COL. - wl 4 #5 VERT. � #3 STIRRUPS NEW 4' CONC. SLAB I @ 8' (4 "@ SPLICES) REINF. WI 6X6 WI A W.W.M. \ Q) =1 - 4' CONC. SLAB wl VINYL FLOOR TILE FINISH - `'C J u 6X6X 1.4X 1.4 wwf ' z w/ BROOM FINISH -- - - ---- - -__-t --- -- CJ 6 ML. VAPOR BARRIER- , WELL- COMPACTED BASE SEE COMPACTION NOTES 51 0 1 NAL: 6 ML. V OR BARRIE WF- 16 - -_� - 5EE5 -1 SCHED. FOR I ADDT. INFO. DDT. INFO. B /A2: Wall Section Thru Porch SCALE: 3/4" : P -0" PREFABRICATED WOOD TRUSSES @ 24' CJC 518" ROOF 5HEATHING- 5EE 5-1 SHEET FOR ADDT. INFO. HURRICANE STRAP SEE STRUCTURAL DWG.5 TYPICAL 2'-0 "+ r 90 DEGREE CUT 7 FA5CIAA55EMBLY: IX2 t 2X6 P.T. MIN.W/ (2) 1 Gd NAILS EA. TRU55 2" EDGE OF SLAB N m SCALE: 3/4" : P -0" _ATTIC VENTILATION BASED ON 2004 FBC 8806.2 ATTIC AREA: 1 280 SF @ (I/ 150) = 9 5F REQ'D. LOWER: EAVE VENTS (022) @ .5 5F EA. = 18 TOTAL Door Schedule NOTE: ALL JAM55, TRIM AND MOLDINGS TO BE WOOD - PAINT -GRADE # ROOM SIZE STYLE TYPE N 0 T E 5 D- I ENTRY 3Gx8Ox 1 -3/4 MTL. IN5UL. LIS. M1551LE IMPACT -SGL. 05/KEY 0-2 EXT. KITCHEN 3Gx80x1 -3/4 MTL. INSUL. LG. MISSILE IMPACT -5GL. DB/KEY D 3 LAUNDRY 54x80x 1 -3/8 FULL LOUVER DEL. BI -FOLD DA PANTRY 28x80x1 -3/8 SOLID SWING- PASSAGE D -5 BEDROOM 1 30x5Ox1 -3/8 50LID SWING- PRIVACY D -6 CL05ET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD - - D -7 CLOSET 24x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D -8 BEDROOM 2 30x80x 1 -3 /8 50LID SWING - PRIVACY D -9 W/H CLOSET 24x80x1 -3 /8 FULL LOUVER BI -FOLD D I 0 BATHROOM 32x80x 1 -318 SOLID SWING- PRIVACY "2004 FBC R322. 1.1 ACCESSIBILITY D I I LINEN CLOSET 48x80x 1 -3/8 FULL LOUVER BI -FOLD D12 HALL CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D13 BEDROOM 3 3 2x80 1 -3/8 SOLID SWING- PRIVACY D14 CLOSET 48x80x 1 -3/8 FULL LOUVER DBL. BI -FOLD D15 A/C CLOSET 28x80x 1 -3/8 SOLID SWING - PRIVACY WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 WOOD TRUSSES - -- -- - i A d PAf.TITa-JN,� Ti C,".INa -_•• _ _ _ ;� 5711`7'NS, Cf: PRCVIC° -(4 aLOCr.NC DO NCITAiAACH PAkAITI�)N' DIRE%i L(TO TRU55 ChORD5� � -I X3WB. 571`°PI` G @ 16" -CI;'C = x+479- 5= 1;151VALL:IIJNG FIXTU'.E5. - - 5Tt105` IN 1AFARiNC WQ[J -S, CXTERIOR WALLS AND NONBEARING PARTITIONS SUPPORTING WALL HUNG PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LE55 THAN 2 X 4, WHERE SPACED NOT MORE THAN I G INCHES (406 MM) 0 CENTER OR, NOT LE55 THAN 2 X G, WHERE SPACED NOT MORE THAN 24 INCHES (61 MM) ON CENTER. 2X4 WOOD STUDS @ I G' OIC - - w/ 1 /2" GWB EA. SIDE USE 12" CEMENTITUOUS BD IN ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 ' "`R322.1.1 ALL NEW SINGLE- FAMILY HOUSES, DUPLEXES, TRIPLEXES, CONDOMINIUMS AND TOWNHOUSES SHALL ( / W o dJ PROVIDE AT LEAST ONE BATHROOM, LOCATED WITH MAXIMUM POSSIBLE PRIVACY, WHERE BATHROOMS ARE PROVIDED (USE I/2 , M.R GWB IN BATH AREAS) f 8307.2 BATHTUB AND SHOWER ON HABITABLE GRADE LEVELS, WITH A DOOR THAT HAS A 29 -IN. CLEAR OPENING. HOWEVER, IF ONLY A TOILET ROOM IS C3 SPACES. BATHTUB AND SHOWER PROVIDED AT GRADE LEVEL, SUCH TOILET ROOMS SHALL HAVE A CLEAR OPENING OF NOT LE55 THAN 29 IN. �o FLOORS AND WALL5 ABOVE m F- R31 1.4.1 EXIT DOOR REQUIRED. NOT LE55 THAN ONE EXIT DOOR CONFORMING TO THI5 SECTION SHALL BE PROVIDED BATHTUBS WITH INSTALLED � z FOR EACH DWELLING UNIT. THE REQUIRED EXIT DOOR SHALL PROVIDE FOR DIRECT ACCESS FROM THE HABITABLE SHOWER HEADS AND IN SHOWER z PORTIONS OF THE DWELLING TO THE EXTERIOR WITHOUT REQUIRING TRAVEL THROUGH A GARAGE. ACCESS TO COMPARTMENTS SHALL BE ? o HABITABLE LEVELS NOT HAVING AN EXIT IN ACCORDANCE WITH THI5 SECTION SHALL BE BY A RAMP IN ACCORDANCE FINISHED WITH A NONABSORBENT J WITH SECTION R3 11.6 OR A STAIRWAY IN ACCORDANCE WITH SECTION R311.5 . SURFACE. SUCH WALL SURFACES m R31 1.4.2 DOOR TYPE AND 51ZE: THE REQUIRED EXIT DOOR SHALL BE A 51DE- HINGED DOOR NOT LESS THAN 3 FT IN SHALL EXTEND TO A HEIGHT OF WIDTH AND G FT 8 IN. IN HEIGHT. OTHER DOORS SHALL NOT BE REQUIRED TO COMPLY WITH THESE MINIMUM NOT LE55 THAN 6 FEET (1829 DIMENSIONS. MM) ABOVE THE FLOOR. R31 1.4.3 LANDINGS AT DOORS .THERE SHALL BE A FLOOR OR LANDING ON EACH 51DE OF EACH EXTERIOR DOOR. EXCEPTION: WHERE A STAIRWAY OF TWO OR FEWER RISERS IS LOCATED ON THE EXTERIOR SIDE OF A DOOR, OTHER USE PT 2X4 @ BOTTOM THAN THE REQUIRED EXIT DOOR, A LANDING IS NOT REQUIRED FOR THE EXTERIOR SIDE OF THE DOOR. PLATE wl 2 -I(4" POWDER DRIVEN FASTENERS wl WA5HERS 36" MAX. THE FLOOR OR LANDING AT EXTERIOR DOORS REQUIRED BY SECTION R31 1.4.1 SHALL NOT BE REQUIRED TO COMPLY OR 2 -1/4" CUT NAILS @ 3 ` MAX WITH THIS REQUIREMENT BUT SHALL HAVE A RISE NO GREATER THAN THAT PERMITTED IN SECTION R31 1.5.3 • CONCRETE FLOOR SLAB - -- - EXCEPTION: THE LANDING AT AN EXTERIOR DOORWAY SHALL NOT BE MORE THAN 73/4 IN BELOW THE TOP OF THE THRESHOLD, PROVIDED THE DOOR, OTHER THAN AN EXTERIOR STORM OR SCREEN DOOR DOES NOT SWING OVER THE LANDING. THE WIDTH OF EACH LANDING SHALL NOT BE LESS THAN THE DOOR SERVED. EVERY LANDING SHALL HAVE A c�NL �p, Interior Partition MINIMUM DIMEN51ON OF 3G IN MEASURED IN THE DIRECTION OF TRAVEL. R311.4.4 TYPE OF LOCK OR LATCH.ALL N.T.S. EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 EGRESS DOORS SHALL BE READILY OPERABLE FROM THE SIDE FROM WHICH EGRESS 15 TO BE MADE WITHOUT THE USE SCALE: NONE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. 8310.1 EMERGENCY ESCAPE AND RESCUE REQUIRED. EVERY SLEEPING ROOM SHALL HAVE AT LEAST ONE OPENABLE EMERGENCY ESCAPE AND RESCUE OPENING. WHERE EMERGENCY ESCAPE AND RESCUE OPENINGS ARE PROVIDED THEY SHALL HAVE A SILL HEIGHT OF NOT MORE THAN 44 IN. ABOVE THE FLOOR. THE NET CLEAR OPENING DIMENSIONS REQUIRED BY THIS SECTION SHALL BE OBTAINED BY THE NORMAL OPERATION OF THE EMERGENCY ESCAPE AND RESCUE OPENING FROM THE INSIDE. EMERGENCY ESCAPE AND RESCUE OPENINGS WITH A FINISHED 51LL HEIGHT BELOW THE ADJACENT GROUND ELEVATION SHALL BE PROVIDED WITH A WINDOW WELL IN ACCORDANCE WITH SECTION 8310.2 R310.1.1 MINIMUM OPENING AREA. ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 5F. EXCEPTION: GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SF R3 10.1.2 MINIMUM OPENING HEIGHT. THE MIN. NET CLEAR OPENING HEIGHT SHALL BE 24 IN, R310.1.3 MINIMUM OPENING WIDTH. THE MIN. NET CLEAR OPENING WIDTH SHALL BE 20 IN. R310.1.4 OPERATIONAL CONSTRAINTS. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE IN51DE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. Window Schedule A7 (5EE'GENERAL NOTE5' FOR WINDOW AND DOOR DATA.) # ROOM 5 1 2 E STYLE GLAZING N 0 T E 5 W -1 BDRMS /LIV /DIN 37 x 63 AL. SGL. HUNG /25 TINTED EGRESS @ BEDROOMS W -2 BATHROOM 37 x 38 3/8 AL. SGL. HUNG /23 TINTED - TEMPERED OBSCURED GLA55 - 2004 FBC 8308.4 HAZ. LOC. W-3 KITCHEN 37 x 38 318 AL. 5GL. HUNG /23 TINTED General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7 General Door & WlndoW Notes ( SEE ELEVATIONS FOR WIND PRESSURES) R303.3 BATHROOMS. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE GLAZING AREA IN WINDOWS OF NOT LE55 THAN 3 SF, ONE -HALF OF WHICH MUST BE OPENABLE• EXCEPTION: THE GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A MECHANICAL VENTILATION SYSTEM ARE PROVIDED. THE MINIMUM VENTILATION RATES SHALL BE 50 CFM FOR INTERMITTENT VENTILATION OR 20 CFM FOR CONTINUOUS VENTILATION. VENTILATION AIR FROM THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTSIDE. 8308.4 HAZARDOUS LOCATIONS. GLAZING IN DOORS AND ENCLOSURES FOR HOT TUBS, WHIRLPOOLS, SAUNAS, STEAM ROOM5, BATHTUBS AND SHOWERS. GLA71NG IN ANY PART OF A BUILDING WALL ENCLOSING THESE COMPARTMENTS WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING 15 LE55 THAN GO IN. CMEA5URED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE. 1. ALL EXTERIOR DOORS AND WINDOWS TO HAVE DADE COUNTY PRODUCT APPROVAL - SEE ATTACHED PA APPLICATION 2. ALL EXTERIOR OPENING5/DOOR5 AND WINDOWS TO CONFORM WITH INTRUSION REQUIREMENTS. ALL NEW EXTERIOR DOORS AND WINDOWS SHALL MEET THE MINIMUM REQUIREMENTS OF THE 2004 FLORIDA BLDG. CODE - 84410.2 INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: - -- ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY - OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6,000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLT INSERTS. - -- ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 Ib5. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH THE RE515TANCE STANDARDS SET FORTH IN THE CURRENT BLDG. CODE. - -- HINGES ON EXTERIOR OUT -SWING DOORS SHALL HAVE NON- REMOVEABLE PINS. 3. ALL EXTERIOR OPENINGS /DOORS AND WINDOWS TO HAVE HURRICANE PROTECTION PANELS/ FBC 84410.2 IMPACT RESISTANT GLASS (OPTIONAL).4. ALL INTERIOR DOORS AND FRAMES TO BE PAINT GRADE FINISH. 5. ALL WINDOWS TO BE LAW50N INDU5TRIE5/WHITE ALUMINUM/LIGHT GRAY TINT GLA55 OR EQUAL. G. ALL BEDROOMS SHALL HAVE A SECONDARY MEANS OF EGRESS. 7. ALL CLOSET AND BATHROOM DOORS ARE TO BE OPERABLE FROM THE INTERIOR SIDE.B.ALL NEW EXTERIOR DOORS 4 WINDOWS SHALL MEET THE MIN. REQUIREMENTS OF THE 2004 FLORIDA BLDG. RESIDENTIAL CODE INCLUDING BUT NOT LIMITED TO THE FOLLOWING ITEMS: ALL SINGLE EXTERIOR SWINGING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MIN. OF 6,000 P0551BLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED STEEL BOLD INSERTS. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVABLE DIRECTION AND IN ACCORDANCE WITH THE RESISTANCE STANDARDS SET FORTH IN THE FBC R 2004 HINGES ON EXTERIOR OUT -5WING DOORS SHALL HAVE NON - REMOVABLE PINS. CITY OF SOUTH MIAMI BI ILOING DEPT. SUIL. ING SECTION APPROVED BY: nn ?ATE: CITY OF SOUTH MIAMI f - fMI.t -Mi iO DEPT. 2" FROM EDGE- - 3116"X2 -114' MASONRY ANCHORS MIN. EMBED DEPTH 1 -1 /2'- TYP. MIN EMBED. DEPTH: I- 1 /2' -TYP. tn o° z w I X4 P.T. ALL AROUND OFG. IXG P.T. INFILL AROUND OPG. FILLED CELUCONC. TYP. ALL SIDES SEE 5-1 FOR LOC.S INTERIOR 51DE WINDOW FASTENERS - REFER TO MFR'S. NOA MARBLE 51LL -5ET w/ ADHESIVE -TYP. I X4 P.T. ALL AROUND OPG. 112' GWB on IX2 PT @ 16' O/C-TYP. Typ. WindOW & Door lamb Detail N.T.S. DATE:_ _ _ 10-01-08 PROJECT: New 1 Sty SFR ADDRESS: 6041 SW 63 ST So. Miami, FL OWNER: Habitat for Humanity Anne Manning, Exec. Director 305 670 -2224 REVISIONS: -- -_- - SEAL kv� 131 a 6 209, ARCHITECT OF RECORD: PAUL W. BUCKLER #13708 '%/ % / ilia %%% j IN HABITAT FOR HUMANITY OF GREATER MIAMI, INC. L ' 360ONW22AYENOE NIIII, FLORIDA 33U2 305.636 -M2 •wru*- .uu•u.umuw ■r.www... w...w -ww ARCHITECTURAL 20F7