13-1379-007(TO REMAIN) (TYP. WHERE SHOWN) A C$ I" &a CONCRETE FOOTING SCHEDULE MARK ELEV. TOP OF FOOTING WIDTH THICK REINFORCING REMARKS CONTINUOUS TRANSVERSE F -4.0 MATCH EXIST. 4' -0 "x 4' -0" 12" #5 ®8" 0. C. EA. WAY BOTT. � ISOLATED HEADED STUDS Elf R 1/4% 11" x V -0" STL. PLATE R Y4'x5 "X1' -0" STL. PLATE SC -1 HSS 4%4%1/4" NOTE: DATUM ELEVATION, +0' -0" STEEL COLUMNS SCHEDULE MARK SIZE BASE P CAP P_ r r7r /7n EXIST. FOOTING I2 Y4 "x 11" x 1' -0" STL. PLATE II? V4 "x7 "x1' -2" STL. PLATE SC -1 HSS 4 "x4 "x1/4° W /(4) ->I% A307 x 6" LONG W /(4) -Y2"O A307 x 6" LONG � HEADED STUDS HEADED STUDS Elf R 1/4% 11" x V -0" STL. PLATE R Y4'x5 "X1' -0" STL. PLATE SC -1 HSS 4%4%1/4" W/(4) -1A"0 A307 x 6" LONG WELDED TO V4'x 9"x 1 -0" SIDE HEADED STUDS PLATES (SEE DET. C /S -4) 1. ALL STEEL COLUMNS SHALL BE GROUT FILLED. ALLOW A 2 "x2" OPENING ON CAP PLATE FOR GROUT PLACEMENT. 2. PROVIDE PRESSURE RELIEF HOLES AT BOTTOM, TOP AND AT MID - HEIGHT. 3. SHOP WELD BASE AND CAP PLATES. 4. Fy= 46 KSI. ANCHORS (REFER TO SCHED.) -STL. COLUMN (REFER TO PLAN & SCHED.) STL. PLATE (REFER TO SCHED.) "SC -1" & SC -2 BASE PLATE ANCHORS (REFER TO SCHED.) STL. PLATE (REFER TO SCHED.) STL. COLUMN (REFER TO PLAN & SCHFD.) SCALE: 1"= 1' -0" 16" O E I- 6#5 VERT. #3 TIES ® 8 "0. C. C -1 (STARTER COL.) -STEEL SIDE PLATE Y4% 9 "x1' -0" WELDED TO STEEL BASE PLATE (TYP. BOTH SIDES) STL. PLATE (REFER TO SCHED.) -STL. COLUMN (REFER TO PLAN & SCHED.) 999SC -2" CAP PLATEN 6 6 #5 VERT. #3 TIES ® 8 "0. C. C -2 CONCRETE COLUMN SCALE: -Y4" = 1' -0" D ETAI LS DO 6 #5 VERT. #3 TIES ® 8 "0. C. C -3 (STARTER COL.) �6T y 06= SO S,rRvC E Ua4,,. SEC i fpN LEGEND CONCRETE COLUMNS PLAN NOTES: ^; 1. FINISH FLOOR ELEVATION +0' -0" U.O.N. COORDINATE W/ARCHITECTURAL- DRAWINGS. 2. COORDINATE W /ARCHITECTURAL & OTHER DRAWINGS FOR INFORMATION NOT SHOWN ON THIS PLAN. 3. COORDINATE ALL WINDOW, DOOR AND OPENING LOCATIONS WITH ARCHITECTURAL DRAWINGS. 4. TYPICAL WALL FOOTING ELEVATION = TO MATCH EXIST. FOOTING ELEV. 5. ALL FOOTINGS SHALL BE CENTERED UNDER WALLS & COLUMNS, U.O.N. & SHALL BE A MIN. 12" BELOW GRADE PER FBC. 6. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, DRAINS, DRAINAGE SLOPE, ETC. NOT SHOWN. 7. ALLOWABLE SOIL BEARING PRESSURE IS 2500 PSF. REFER TO GENERAL NOTES AND GEOTECHNICAL REPORT. 8. GROUND FLOOR SLAB SHALL BE 3" CONCRETE SLAB REINF. W /6x6- W1.4xW1.4 W.W.F. OVER EXIST. CONC. SLAB -ON -GRADE (REFER TO DIET. K /S -6). 9. ALL SUBGRADE PREPARATION FOR THE SLAB -ON -GRADE & FOOTINGS SHALL BE IN ACCORDANCE WITH THE PROJECT GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. TEMPORARY SHORING NOTES: 1. SHORE REQ'D AREAS FROM ROOF TO TOP OF EXISTING GRADE /SLAB. 2. DEMOLITION FOR THIS PROJECT SHALL INCLUDE INTERIOR NON- STRUCTURAL DEMOLITION AS SHOWN ON ARCHITECTURAL DWGS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE BRACING OF ALL STRUCTURAL MEMBERS, WALLS AND NON- STRUCTURAL ITEMS DURING DEMOLITION AND CONSTRUCTION. 4. FOR ANY TEMPORARY BRACING AND SHORING REQ'D DURING DEMOLITION, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF A SPECIALTY ENGINEER AND SUBMIT REQ'D SIGNED AND SEALED SHOP DWGS. AND SUPPORTING CALCULATIONS FOR ALL SHORING & BRACING OF THE EXISTING STRUCTURE FOR A/E REVIEW & APPROVAL PRIOR TO PROCESSING THRU THE BUILDING DEPARTMENT. 5. AREAS OF THE ROOF STRUCTURE THAT ARE SUPPORTED BY TEMPORARY SHORING ELEMENTS SHALL NOT BE UTILIZED AS CONSTRUCTION STAGING AREAS. 6. CONTRACTOR SHALL PROVIDE LATERAL BRACING FOR ALL TEMPORARY SHORING ELEMENTS, INCLUDING PROVISIONS FOR WIND UPLIFT AT EXPOSED AREAS OF CONSTRUCTION. 7. TEMPORARY STRUCTURES WHICH SUPPORTS EXISTING CONCRETE & MASONRY CONSTRUCTION THAT IS DESIGNATED TO REMAIN SHALL BE DESIGNED & INSTALLED TO SATISFY THE DEFLECTION CRITERIA OF ACI 530, LATEST EDITION. 8. AREAS OF THE ROOF STRUCTURE THAT ARE SUPPORTED BY TEMPORARY SHORING SHALL BE POSITIVELY DRAINED WHILE THE SHORING IS IN PLACE. 9. TEMPORARY SHORING SHALL REMAIN IN PLACE UNTIL ALL NEW STRUCTURAL ELEMENTS ARE IN PLACE AND ALL CONNECTIONS ARE COMPLETE & INSPECTED. FOUNDATION PREPARATION NOTES: 1. LOCATE THE FOUNDATION FOR THE PROPOSED BUILDING, PLUS A MINIMUM 5' -0" OUTSIDE THE FOOTPRINT OF THE FOUNDATION AND REMOVE APPROX. 4' -0" OF ALL EXISTING ORGANIC SOIL & SAND MATERIAL UNTIL A SOLID LIMESTONE BASE IS FOUND. 2. PROVIDE TEMPORARY BRACING AND /OR SHORING FOR ALL EXCAVATIONS TO COMPLY WITH FLORIDA STATUTES SECTION 553.60 & 2010 FBC REQUIREMENTS. 3. PROOF- ROLLING OF THE CLEARED SURFACE SHALL BE PROVIDED, CONSISTING OF AT LEAST 10 PASSES OF A SELF - PROPELLED VIBRATORY COMPACTOR CAPABLE OF DELIVERING A MINIMUM IMPACT FORCE OF 30,000 TO 35,000 POUNDS PER DRUM TO THE SOIL SURFACE. EACH PASS SHOULD OVERLAP THE PRECEDING PASS BY 30 PERCENT TO ACHIEVE COMPLETE COVERAGE. THE PROOF- ROLLING SHOULD OCCUR AFTER CLEARING AND BEFORE BACK - FILLING. 4. COMPACT THE EXCAVATED AREA USING A COMPACTOR TO A DENSITY EQUIVALENT TO 95% OF THE MODIFIED PROCTOR TEST (ASTM D -1557) MAXIMUM DRY DENSITY VALUE IN LAYERS OF 12" MAXIMUM UNCOMPACTED THICKNESS. IF HAND -HELD COMPACTION EQUIPMENT IS USED, THE LIFT THICKNESS SHOULD BE REDUCED TO 6 ". 5. ALL FILL MATERIAL SHALL BE FREE OF ORGANIC MATERIALS & SHALL CONSIST OF A MIXTURE OF LIMESTONE & LIMESAND WITH THE LARGEST DIMENSION NOT GREATER THAN 2 ". 6. VERIFY ALL DENSIFICATION PROCEDURES BY TAKING 1 FIELD DENSITY TEST PROBING 12" INTO THE UNDERLYING FILL FOR EVERY 20 LINEAR FEET OF TRENCH WIDTH AND 1 TEST FOR EVERY COLUMN PAD. 7. PROVIDE CERTIFIED DENSITY TEST REPORTS TO THIS ENGINEER BEFORE CONTINUING WITH FOUNDATION CONSTRUCTION. ENGINEER OF RECORD SHALL REVIEW THE REPORTS AND APPROVE IN WRITING PRIOR TO THE CONTRACTOR POURING OF THE CONCRETE FOR FOUNDATIONS. TERMITE PROTECTION STATEMENT: ALL BUILDINGS SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES AS PER 2010 FBC SECTION R320. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE & CONSUMER SERVICES ". TO THE BEST OF MY KNOWLEDGE THESE PLANS CONFORM TO THE STRUCTURAL REQUIREMENTS OF F.B.C. 2010, LATEST REVISIONS, INCLUDING SECTIONS PERTAINING TO AV.H.Z. ENGINEER OF RECORD HEREBY EXPR SLY i b` •• „ RESERVES HIS COMMON LAW CO AND OTHER PROPERTY RIGHTS THESE. PLANS. THIS DESIGN AND DRAW S A ^6 L�•' , i, 7 NEITHER TO BE REPRODUCED, COPIED, R CHANGED IN ANY FORM OR MANNER WHAT n ALEXANDER''MICHELls SO EVER NOR ASSIGNED TO ANY PARTY: WITHOUT FIRST OBTAINING THE EXPRESS: FLS fAFLE X0735 ROCHELL ENGINEERING, INC WRITTEN PERMISSION AND CONSENT OF' Z 5 Santfll STRUCTURAL CONSULTING ENGINEERS ROCHELL ENGINEERING, INC. �¢Ibe�q�D3134 1� : CERT.' OF AUTHORIZATION No. 27054 y 649.4Q49 fNir X4149 Vt NAI. g•" _,ue lul -a aeciSR company, inc. 2750 NW 3RD AVE STE 23 MIAMI FLORIDA. 33127 TEL (305) 531 -8688 FAX (305) 531 -4554 # AA 26001595 # IB 26000969 These design drawings are the exclusive copyright of blue, a design company, inc. These drawings and plans are prepared solely for use with this project and are not to be disseminated for use by any other individual or ntity or any other project without the written company, inc. CONBULTMR CLIENT / PROJECT ADDRESS U EXIST. CMU WALL Z NEW FOOTING r r7r /7n EXIST. FOOTING L1UU 7 SLAB EDGE PLAN NOTES: ^; 1. FINISH FLOOR ELEVATION +0' -0" U.O.N. COORDINATE W/ARCHITECTURAL- DRAWINGS. 2. COORDINATE W /ARCHITECTURAL & OTHER DRAWINGS FOR INFORMATION NOT SHOWN ON THIS PLAN. 3. COORDINATE ALL WINDOW, DOOR AND OPENING LOCATIONS WITH ARCHITECTURAL DRAWINGS. 4. TYPICAL WALL FOOTING ELEVATION = TO MATCH EXIST. FOOTING ELEV. 5. ALL FOOTINGS SHALL BE CENTERED UNDER WALLS & COLUMNS, U.O.N. & SHALL BE A MIN. 12" BELOW GRADE PER FBC. 6. SEE ARCHITECTURAL DRAWINGS FOR DIMENSIONS, ELEVATIONS, DRAINS, DRAINAGE SLOPE, ETC. NOT SHOWN. 7. ALLOWABLE SOIL BEARING PRESSURE IS 2500 PSF. REFER TO GENERAL NOTES AND GEOTECHNICAL REPORT. 8. GROUND FLOOR SLAB SHALL BE 3" CONCRETE SLAB REINF. W /6x6- W1.4xW1.4 W.W.F. OVER EXIST. CONC. SLAB -ON -GRADE (REFER TO DIET. K /S -6). 9. ALL SUBGRADE PREPARATION FOR THE SLAB -ON -GRADE & FOOTINGS SHALL BE IN ACCORDANCE WITH THE PROJECT GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. TEMPORARY SHORING NOTES: 1. SHORE REQ'D AREAS FROM ROOF TO TOP OF EXISTING GRADE /SLAB. 2. DEMOLITION FOR THIS PROJECT SHALL INCLUDE INTERIOR NON- STRUCTURAL DEMOLITION AS SHOWN ON ARCHITECTURAL DWGS. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ADEQUATE BRACING OF ALL STRUCTURAL MEMBERS, WALLS AND NON- STRUCTURAL ITEMS DURING DEMOLITION AND CONSTRUCTION. 4. FOR ANY TEMPORARY BRACING AND SHORING REQ'D DURING DEMOLITION, THE CONTRACTOR SHALL ENGAGE THE SERVICES OF A SPECIALTY ENGINEER AND SUBMIT REQ'D SIGNED AND SEALED SHOP DWGS. AND SUPPORTING CALCULATIONS FOR ALL SHORING & BRACING OF THE EXISTING STRUCTURE FOR A/E REVIEW & APPROVAL PRIOR TO PROCESSING THRU THE BUILDING DEPARTMENT. 5. AREAS OF THE ROOF STRUCTURE THAT ARE SUPPORTED BY TEMPORARY SHORING ELEMENTS SHALL NOT BE UTILIZED AS CONSTRUCTION STAGING AREAS. 6. CONTRACTOR SHALL PROVIDE LATERAL BRACING FOR ALL TEMPORARY SHORING ELEMENTS, INCLUDING PROVISIONS FOR WIND UPLIFT AT EXPOSED AREAS OF CONSTRUCTION. 7. TEMPORARY STRUCTURES WHICH SUPPORTS EXISTING CONCRETE & MASONRY CONSTRUCTION THAT IS DESIGNATED TO REMAIN SHALL BE DESIGNED & INSTALLED TO SATISFY THE DEFLECTION CRITERIA OF ACI 530, LATEST EDITION. 8. AREAS OF THE ROOF STRUCTURE THAT ARE SUPPORTED BY TEMPORARY SHORING SHALL BE POSITIVELY DRAINED WHILE THE SHORING IS IN PLACE. 9. TEMPORARY SHORING SHALL REMAIN IN PLACE UNTIL ALL NEW STRUCTURAL ELEMENTS ARE IN PLACE AND ALL CONNECTIONS ARE COMPLETE & INSPECTED. FOUNDATION PREPARATION NOTES: 1. LOCATE THE FOUNDATION FOR THE PROPOSED BUILDING, PLUS A MINIMUM 5' -0" OUTSIDE THE FOOTPRINT OF THE FOUNDATION AND REMOVE APPROX. 4' -0" OF ALL EXISTING ORGANIC SOIL & SAND MATERIAL UNTIL A SOLID LIMESTONE BASE IS FOUND. 2. PROVIDE TEMPORARY BRACING AND /OR SHORING FOR ALL EXCAVATIONS TO COMPLY WITH FLORIDA STATUTES SECTION 553.60 & 2010 FBC REQUIREMENTS. 3. PROOF- ROLLING OF THE CLEARED SURFACE SHALL BE PROVIDED, CONSISTING OF AT LEAST 10 PASSES OF A SELF - PROPELLED VIBRATORY COMPACTOR CAPABLE OF DELIVERING A MINIMUM IMPACT FORCE OF 30,000 TO 35,000 POUNDS PER DRUM TO THE SOIL SURFACE. EACH PASS SHOULD OVERLAP THE PRECEDING PASS BY 30 PERCENT TO ACHIEVE COMPLETE COVERAGE. THE PROOF- ROLLING SHOULD OCCUR AFTER CLEARING AND BEFORE BACK - FILLING. 4. COMPACT THE EXCAVATED AREA USING A COMPACTOR TO A DENSITY EQUIVALENT TO 95% OF THE MODIFIED PROCTOR TEST (ASTM D -1557) MAXIMUM DRY DENSITY VALUE IN LAYERS OF 12" MAXIMUM UNCOMPACTED THICKNESS. IF HAND -HELD COMPACTION EQUIPMENT IS USED, THE LIFT THICKNESS SHOULD BE REDUCED TO 6 ". 5. ALL FILL MATERIAL SHALL BE FREE OF ORGANIC MATERIALS & SHALL CONSIST OF A MIXTURE OF LIMESTONE & LIMESAND WITH THE LARGEST DIMENSION NOT GREATER THAN 2 ". 6. VERIFY ALL DENSIFICATION PROCEDURES BY TAKING 1 FIELD DENSITY TEST PROBING 12" INTO THE UNDERLYING FILL FOR EVERY 20 LINEAR FEET OF TRENCH WIDTH AND 1 TEST FOR EVERY COLUMN PAD. 7. PROVIDE CERTIFIED DENSITY TEST REPORTS TO THIS ENGINEER BEFORE CONTINUING WITH FOUNDATION CONSTRUCTION. ENGINEER OF RECORD SHALL REVIEW THE REPORTS AND APPROVE IN WRITING PRIOR TO THE CONTRACTOR POURING OF THE CONCRETE FOR FOUNDATIONS. TERMITE PROTECTION STATEMENT: ALL BUILDINGS SHALL HAVE PRE - CONSTRUCTION TREATMENT PROTECTION AGAINST SUBTERRANEAN TERMITES AS PER 2010 FBC SECTION R320. A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH THE RULES & LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE & CONSUMER SERVICES ". TO THE BEST OF MY KNOWLEDGE THESE PLANS CONFORM TO THE STRUCTURAL REQUIREMENTS OF F.B.C. 2010, LATEST REVISIONS, INCLUDING SECTIONS PERTAINING TO AV.H.Z. ENGINEER OF RECORD HEREBY EXPR SLY i b` •• „ RESERVES HIS COMMON LAW CO AND OTHER PROPERTY RIGHTS THESE. PLANS. THIS DESIGN AND DRAW S A ^6 L�•' , i, 7 NEITHER TO BE REPRODUCED, COPIED, R CHANGED IN ANY FORM OR MANNER WHAT n ALEXANDER''MICHELls SO EVER NOR ASSIGNED TO ANY PARTY: WITHOUT FIRST OBTAINING THE EXPRESS: FLS fAFLE X0735 ROCHELL ENGINEERING, INC WRITTEN PERMISSION AND CONSENT OF' Z 5 Santfll STRUCTURAL CONSULTING ENGINEERS ROCHELL ENGINEERING, INC. �¢Ibe�q�D3134 1� : CERT.' OF AUTHORIZATION No. 27054 y 649.4Q49 fNir X4149 Vt NAI. g•" _,ue lul -a aeciSR company, inc. 2750 NW 3RD AVE STE 23 MIAMI FLORIDA. 33127 TEL (305) 531 -8688 FAX (305) 531 -4554 # AA 26001595 # IB 26000969 These design drawings are the exclusive copyright of blue, a design company, inc. These drawings and plans are prepared solely for use with this project and are not to be disseminated for use by any other individual or ntity or any other project without the written company, inc. CONBULTMR CLIENT / PROJECT ADDRESS U Z W U L�J Q 0 __J Q U7 � L�J Elf CC) O LL Q U7 Q O Q0 MAWN E. M. 09 -20 -13 KNIM AS SHOWN MRTNETO sQr S -1 av s�EEts