Loading...
13-1379-006SUSS 120/2400 10 3 "110 THHN 4 1 04G (EXISTING) ELECTRICAL PANEL. A 100 A.M.F AI.C. RATING 10,0010 WATTS. DESCRIPTION. CIR WIRE BRK CIR CIR 5R9 WIRE DESCRIPTION. 110 WATTS. 1000 LANDSCAPE LIGHTS 20 014 15 1 2 60 A/C PACKAGE UNIT 3 10,000 1000 LANDSCAPE LIGHTS GENERAL RECPT/ LIGHTING 014 15 3 4 20 "6 ' 20 012 MSTR BATH WALL HEATER SPARE 1200 GENERAL RECPT/ LIGHTING :12 5 & 8 20 SPARE HALL BATH WALL HEATER 1,800 1200 GENERAL RECPT/ LIGHTING 012 20 S 1 g 012 GENERAL RECPT/ LIGHTING 1200 1200 GENERAL RECPT/ LIGHTING 012 ' 11 12 20 S 10 1200 1200 GENERAL RECPT/ LIGHTING 012 20 13 • 20 012 GENERAL RECPT/ LIGHTING 11 12 SPARE 012 , 15 16 2000 SUB -TOTAL SPARE 1200 1200 MICROWAVE 012 20 11 SUB -TOTAL 20 10,000 TOTAL CONK. LOAD BASED ON HVAC IN HTG. MODE : 12,000 NOTE: CONTRACTOR TO VERFY CIRCUIT LOCATION. LOAD CALC.. wVAC o 1009 : 10,000 1sT. IOKVA(1009) 2000 DEMAND LOAD 12,000/ 240 VOLTS 50 AMPS REST (409) 0 ]_ ELECTRICAL NOTES I. Genera I A. All work performed under this contract shall comply with all national, state and local codes having jurisdiction and with, the requirements of the utility companies whose services shall be used. All modifications required by these codes shall be made by this contractor without additional charge. B. Drawins: Refer to all drawings for coordination of the electrical work C. Arrange and pay for all permits, licenses, inspections and tests. Obtain the required certificates and present to owner. D. Guarantee: The completed installation shall be fully guaranteed against defective materials and /or improper workmanship for minimum Of one year for material and labor. 2. Contractor is directed to review the building plans and specifications for limitations of constructions, identifications of materials and products, definition of workmanship. This contractor shall include his bid proposal all costs necessary for a complete and operational installation and shall visit the job site prior to a bid date. 4. All required insurance shall be provided for protection against public liability and property damage for duration of the work. 5. It shall not be the intent of these plans and /or specifica- tions to show every minor detail of construction. The electrical contractor shall be expected to furnish and install all items for a complete electrical system and provide all requirements necessary for equipment to be placed in proper working order. 6. Electrical contractor shall not scale drawings. Contractor shall refer to architectural plans and elevations for exact locations of all equipment unless otherwise noted. -I. All conduit runs are shown diagrammactically. Exact routing shall be determined in the field, unless otherwise noted. 8. Electrical contractor shall visit the Job site and verify all conditions, locations, dimensions and counts as shown and /or noted on the drawings. This shall include any and all fabrications prior to installations. S. As a minimum, all equipment shall meet applicable standards, for the type of equipment and intended use, of the following: a. American National Standards Institute (ASTM). b. Illuminating Engineers Society OES). C. American Society for Testing and Materials (ASTM) d. National Electrical Manufacturer's Association (NEMA). Note: These standards are subordinate to codes, and standards set by UL. 10. All electrical equipment, devices, wire, ect. shall be listed, for the intended use, with Underwriter laboratories, Inc. (UL), where standards have been established by UL. 11. Where more than one devices is indicated at any location, these shall be ganged under one common cover plate. 12. Contractor shall coordinate with electric and telephone utility for service entrance location and any other require- ments. 13. All connections to ground rods shall be made with UL approved method connections, unless noted otherwise. 14. Provide a fuse holder and fuse in the primary side of each ungrounded conductor for a l l ballasts. 15. Contractor shall guarantee all materials and workmanship free from defects for a period of not less than (1) year from date of acceptance, unless indicated of specified otherwise. 16- Correction of any defects shall be completed without additional charge and shall include replacement or repair of any other phase of the installation which may have been damaged thereby. M. Electrical contractor shall provide temporary service for use of all trades as required for construction. 18. Temporary wiring to be removed by electrical contractor. 19. Electrical contractor shall verify requirements, exact location and type or outlet for all electrical fixtures, appliances and equipment. 20. Show drawings: Coordinate with owner or architect. 21. All wiring to have 600 volt insulation, type TW, THW, THWN,THHN, for branch circuits and type THW, T14N for main feeders or as specified. 22. Design is based on THHN wire. 23. Wire ways shall be sized as required, per NEC, unless otherwise noted. 24. All feeder, subfeeder and branch circuits shall be properly phase balanced. 25. All conductors shall be in conduits. All conduits shall be intermediate (IMC) or rigid galvanized steel (RGS) except that: (a) poly vinyl chloride (PVC) conduits may used in concrete slabs at underground provided elbows and riser are RGSt (b) electrical metallic tubing (EMT) may be used in or on walls or ceilings where not subject to mechanical damage, damp conditions or corrosive conditions± (c) liquid tight flexible conduits where required± (d) flexible metallic conduit where required in dry locations. All conduit hazardous areas (per NEC) shall meet the requirements of NEC Chapter. 26. Electrical contractor shall verify circuit protective device rating for equipment prior to construction. 2-1. Provide fuse recommended by equipment manufacturer. 28. Furnish and install disconnect switches and wiring for air conditioning systems as per manufacturer recommendations. Controls are to be supplied by air conditioning contractor. 29. Install power and control wiring and required control components for air condition systems as shown /noted on these drawings and per other applicable drawings/instruc- tions see A/C drawings. 30. Electrical contractor to run control wires for HVAC system as per HVAC drawings. 31. No conduits to be run in ductwork 32. All electrical wiring must be in conduit (Romex, etc. is not permitted unless specific permission is obtained from owner or local inspector). SUSS (EXISTING) 120/240Y 10 2 00 A.M. 3 02/0 THHN 4 1 04G IN 2' CONE) ELECTRICAL -'eL ��N L. AI.C. RATING 10000 WATTS. DESCRIPTION WIRE BRK CIR CIR 15FK WIRE DESCRIPTION. WATTS. 25,200 SUS PANEL 'C' 110 Z 1 2 20 012 GENERAL RECPT/ LIGHTING 1200 i 10,000 AICS ' UPGRADE TO NEW BREAKER— 125 3 4 20 012 GENERAL RECPT/ LIGHTING 1200 1200 GENERAL RECPT/ LIGHTING 012 20 r✓' 6 20 012 MSTR BATH WALL HEATER 1,800 1200 GENERAL RECPT/ LIGHTING :12 20 1 8 20 012 HALL BATH WALL HEATER 1,800 1200 GENERAL RECPT/ LIGHTING 012 20 S 10 20 012 GENERAL RECPT/ LIGHTING 1200 1200 GENERAL RECPT/ LIGHTING 012 20 11 12 20 012 G=ENERAL RECPT/ LIGHTING 1200 1200 GENERAL RECPT/ LIGHTING 012 20 13 14 20 012 GENERAL RECPT/ LIGHTING 1200 1200 SPARE 012 20 15 16 20 012 SPARE 1200 1200 MICROWAVE 012 20 11 18 20 "12 GENERAL LIGHTING 1000 1200 ' 012 20 19 20 20 012 ' 1200 1200 ' 012 20 21 22 20 012 ' 1200 1200 GENERAL RECEPT 012 20 23 24 20 012 ' 1200 1200 GENERAL LIGHTING 012 20 25 26 20 012 ' 1200 1200 GENERAL LIGHTING 012 20 21 28 20 012 ' 1200 1200 FREEZER "12 20 2S 30 20 012 MICROWAVE 1500 32,400 SUB -TOTAL 012 20 31 32 20 012 SUB -TOTAL 8,400 TOTAL CONN. LOAD BASED ON HVAC IN HTG. MODE : 40,800 LOAD CAL(.: HVAc m 1009 : 0 PANEL 'C' A 1009 :25 ,200 IsT. 10KVA(1009) 10.000 DEMAND LOAD 3-1,440/ 240 VOLTS 156 AMPS REST (409): 2,240 EXTERIOR 6Y1" i. EXIST SY1" i. CT/ 3 METER 0 O 0 I $ EXIST EXIST PANEL "B' i PANEL "C" 120124OV, 120124OV, 200 I 1 PH, 3W I 1 PH, 3W 2 200 I 200 AMP I 150 AMP NEMA 3R $ 10,000 AICS i 10,000 AICS EXIST I °ANEL "A" O 120/24OV, I PH, 3W Y HALLWAY 100 AMP L------1----------- UTILITY ROOM INTERIOR MCB 1000 D 012 NEW UNDERGROUND 5 SERVICE TO BE 35 COORDINATED W/ FPL STOVETOP Q— EXIST 01 /0 CU,THW GROUND EXISTING M.C.W.P. THERMOSTAT METALIG GOLD L — — — _ WATER PIPE — — T7 EXISTING "6 COOPER GROUNG (MIN.) TO TELEPHONE BOARD EXISTING 3/4'0x10' -0'L COOPER CLAD GROUND RODS DRIVEN INTO GROUND 03 0400 MGM W/ 03 GROUND IN 3" COND O2 3 0210 THHN 4 1 04 GR IN 2' CONE) Q3 3 01/0 THHN d 1 "6 GR IN 2 "" COND ELECTFRICAL fRISEIR [DIAGIRAtl N.T.S. a I a CTR i C,1 L_ L E=_C- a11-1lD 6Y1" i. DESCRIFTiON SY1" i. DESCRIPTION 0 DISTRIBUTION PANEL $ SINGLE POLE SWITCH O SURFACE MOUNTED LIGHT FIXTURE $ DOUBLE POLE SWITCH 30 O 3 2 35 INCANDESCENT CEILING LIGHT $ DIMMER SWITCH • 010 O VAPOR PROOF LIGHT DUPLEX OUTLET VP 1000 GENERAL LIGHTING 012 INTERIOR WALL MOUNTED LIGHT 5 220 VOLT OUTLET 35 STOVETOP 5.800 1800 THERMOSTAT e- 115 VOLT DEDICATED OUTLET T7 CEILING FAN W/ LIGHT KIT GF.C.I. OUTLET ' OFI • ® RECESSED EXTRACTOR FAN S WATER PROOF EXTERIOR OUTLET 20 12 WP 1500 T TELEPHONE JACK O J -BOX 1❑ TV /GABLE 0 FLUORESCENT LIGHT o LIGHT FIXTURE ® SMOKE DETECTOR IIOW BATTERY BACK -UP 012 20 13 INTERCONNECTED 20 TRACK LIGHT GENERAL RECP /LIGHTING 1200 1200 (E) EXIST CIRCUIT TO REMAIN (N) NEW CIRCUIT (R) RELOCATED CIRCUIT EXIST FPL SERVICE LOCATION SEE SITE FOR SPECS EXIST ELEC METER AND SERVICE LOCATION TO REMAIN AND NEW UNDER3ROUND SERVICE TO BE COORDINATED W/ FPL TRENCH 2 ADDITIONAL PVC FOR CABLE, TELEPHONE AS PER COBVER SHEET SUSS (EXISTING) 120/240Y 1-0 ir5sa A.1„1.1= 3 M/0 THHN 4 1 04G IN 2' CONE) ELECTRICAL I=AN E L. C AI.C. RATING 10000 VA. DESCRIPTION. WIRE BFW CIR CIR 15R< WIRE DESCRIPTION. V.A. 5000 DRYER 30 O 1 2 35 OVEN 5.500 I • 010 3 4 "8 ' 1000 GENERAL LIGHTING 012 20 5 6 35 STOVETOP 5.800 1800 WATER HEATER 30 1 8 08 ' • 010 S 10 20 12 SMALL APPLI 1500 1200 DISHWASHER 30 010 11 12 20 012 GENERAL RECP 1200 1500 SMALL APPLI 012 20 13 14 20 012 GENERAL RECP /LIGHTING 1200 1200 REF 012 20 15 I6 20 012 GENERAL RECP /LIGHTING 1200 1200 MICROWAVE 012 20 11 18 20 "12 GENERAL LIGHTING 1000 1200 GENERAL RECEPT 012 20 IS 20 20 012 1 GENERAL RECP 1200 1200 GENERAL RECEPT 012 20 21 22 20 012 GENERAL RECD 1200 1200 GENERAL RECEPT 012 20 23 24 20 012 GENERAL RECD 1200 1200 GENERAL LIGHTING 012 20 25 26 20 012 GENERAL RECP 1200 1200 GENERAL LIGHTING 012 20 21 28 20 012 GENERAL RECP 1200 1200 FREEZER "12 20 29 30 20 012 MICROWAVE 1500 1500 WASHER 012 20 31 32 20 012 GENERAL RECP /LIGHTING 1200 21.600 SUS -TOTAL SUB -TOTAL 26,400 TOTAL CONN. LOAD BASED ON HVAC IN HTG. MODE : 48,000 NOTE: CONTRACTOR TO VERFY CIRCUIT LOCATION. LOAD CALC HVAC a l00% : 0 1sT. 10KVA0009) 10000 � DEMAND LOAD 25,200/ 240 VOLTS 10500 AMPS REST (409) 1500 EXIST ELEC PANEL 'A' PROVIDE 1' CAPPED PVC PASS THRU FOR FUTURE SPEAKERS FLOOR ELECTRICAL PLAN- SCALE: ue a dcs:gq Company, +'I" 2750 NW 3rd AVE SUrrE 23 MIAMI FLORIDA 33127 TEL (305) 531.8688 FAX (305) 531 -4554 # AA 26001595 # IB 26000969 These design drawings are the exclusive copyright of blue, a design company, inc These drawings and plans are prepared solely for use with this project and are not to be disseminated for use by any other individual or entity or any other project without the written consent of blue , a design company, inc CCN5ULTANT CLIENT / PROJECT ADDRESS W V Q Q W Q J Q _ W 'I- O f.L LL ORAVN VERSO DATE 12/10/13 REVISED SCALE AS SHOUIN JOB NO, MRTNETO SHEET E =1 Of SHEETS I ;I W Q Ln r � <<< L 0� ORAVN VERSO DATE 12/10/13 REVISED SCALE AS SHOUIN JOB NO, MRTNETO SHEET E =1 Of SHEETS I ;I