Loading...
09-431-005MEGHAN I GAL PLAN <t N Q cv DIFFUSER LOW VELOCITY SUPPLY AIR PLENUM R -6 INSULATION SEAL DUCT JOINT WITH DUCT SEALER 4 TAPE INSULATED FLEX DUCT R -ro INSULATION SEAL DUCT JOINT WITH DUCT SEALER d TAPE FLEX15LE IDUCT • E)ETAL- 1. THE WORK THAT 15 TO BE PONE UNDER TH15 HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, pEfkj j-r5, Fj�: INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRE; f-OR THE COMPLETION OF THE AIR CONDITIONING 5Y5TEl l .40` 4M-ON THE- PRAWING5 AND /OR L15TED BELOW. 2. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH 6AU6E5, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE AND 5.M.A.C.N.A. STANDARDS. DUCT SIZES5HOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF 'DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. "p 3. FLEXIBLE DUCT SHALL BE STEEL HELIX WIRE ON -7/5" CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE. THE CORE 15 TO BE INSULATED WITH FIBERGLASS INSULATION (R -6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT 15 CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR SHALL BE EXTENDED OUTSIDE INSULATION. 4. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1 -1/2" (R -6 MIN.) FIBERGLASS U.L. 151 LISTED, GLASS I AIR DUCT. DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH 5.M.A.C.N.A. STANDARDS. (R -6 TOP LEVEL. R -4.2 IN OTHER LEVELS). 5. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR HEATING /COLLIN6 WITH STAGE5 AS REQUIRED. 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROORE55 OF CON5TRUCTION;-AND IN STRICT. COMPLIANCE WITH ALL APPLICABLE CODES AND 5TANDARP5:y a , 1. MECHANICAL CONTRACTOR SHALL VERIFY DIRECTION OF EXISTING STRUCTURE BEFORE INSTALLATION OF EQUIPMENT AND DUCTWORK. SHOULD ANY DISCREPANCIES BE FOUND CONTACT ARCHITECT/ENGINEER. 8. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOI5E FROM BEING HEARD. q. GUARANTEES: A. ALL COMPRE55OR MOTORS ON NEW EQUIPMENT FURNISHED UNDER TH15 CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM DATE OF 5TART -UP. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LE55 THAN I YEAR FROM DATE OF ACCEPTANCE. 10. TESTING: A. ALL REFRIGERANT H16H SIDE PIPING TO BE 300 P516. LOW SIDE TO 150 P516. AFTER TESTING, EVACUATE SYSTEM TO 28% MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIE5 AT EACH OUTLET WITHIN 5% U51NG A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION. 11. REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH 3/4" IN- COAFLEX. ARMAFLEX INSULATION MAY ONLY BE USED IN NON- PLENUM AREAS. FINISHED WHERE EXP05ED WITH 2 COATS OF WHITE LATEX PAINT AS PER MANUFACTURER'5 INSTRUCTION. 12. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER WITH WROUGHT COPPER SOLDER FITTINGS. JOINTS SHALL BE MADE WITH SILVER SOLDER OR "51LF05 ". ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE 11 HIGH IMPACT PVC WITH SLIP JOINT FITTING OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER. 13. ALL WORK SHALL CONFORM WITH THE MECH. BLDG. CODE 2001, 2002 REVISIONS. AND ALL OTHER APPLICABLE STATE AND LOCAL REGULATIONS AND ORDINANCES, CONDENSING UNIT SCHEDULE (EXSTG) UNIT LOCATION OUTSIDE UNIT WEIGHT (LBS.) 227 UNIT NOMINAL CAP. (TONS) 3 1/2 MATCHING AHU NUMBER AHU -1 MANUFACTURER RHEEM MODEL NUMBER RAND -042C TOTAL COOLING CAP. (BTUH) 40,500 TOTAL SENSIBLE CAP. (BTHU) 28,850 AMBIENT TEMPERATURE 95° UNIT MIN. SEER 13.15 AVAILABLE VOLTAGE 208/230/1 -60 CIRCUIT BKR. MIN. AMPERES 25/25 CIRCUIT BKR. MAX. AMPERES 40/40 SUCTION LINE DIAM. 1 1/8' LIQUID LINE DIAM, 5/16' CALCULED TOT, COOLING CAP, 36,535 AIR HANDLING UNIT SCHEDULE (EXSTG) UNIT NUMBER A.H,U. -1 MATCHING CONDENSING UNIT CU -1 MANUFACTURER RHEEM MODEL NUMBER RCHJ -48A1 UNIT LOCATI ❑N CLOSET UNIT TYPE VERTICAL ENTERING AIR TEMP. (db /wb) 800/67° EXTERNAL STATIC PRESS, 0.30 FAN MOTOR 1/3 AVAILABLE VOLTAGE 208/240 -1 -60 NUMBER OF STEPS 1 FILTER TYPE PERMANENT CFM 1,325 HEAT (kw) 8.5 @ 240V `1