Loading...
09-431-004MEGHAN I GAL PLAN Q (V LOW VELOCITY SUPPLY AIR PLENUM R -(o INSULATION ,I/ SEAL DUCT JOINT WITH DUCT SEALER E TAPE INSULATED FLEX DUCT R -6 INSULATION SEAL DUCT JOINT I i - 4 TAPE FLEX15LE DUCT CONNECTION, DETAL N.T.S. 6ENERAL NOTES- 1. THE WORK THAT 15 TO BE DONE UNDER THI5 HEADING INCLUDES THE FURNISHING OF ALL LABOR, MATERIALS, EQUIPMENT, PERMITS, FE-Fr-;, INSPECTIONS, TESTS, INSURANCE, ETC. REQUIRED FOR TF COMPLETION OF THE AIR CONDITIONING SYSTEM SHOWN 2:)N `,'HE DRAWING5 AND /OR L15TED BELOW. 2. VENTILATION DUCTWORK SHALL BE GALVANIZED STEEL WITH 0AU6E5, DUCT CONSTRUCTION, BRACING AND SUSPENSION IN ACCORDANCE WITH THE RECOMMENDATIONS SET FORTH IN THE LATEST EDITION OF THE A.S.H.R.A.E. GUIDE AND 5.M.A.C.N.A. STANDARDS. DUCT SIZES 5HOWN ARE "INSIDE" DIMENSIONS. VERIFY EXACT LOCATION OF DUCT WITH RESPECT TO STRUCTURE BEFORE FABRICATION. 3. FLEXIBLE DUCT SHALL BE STEEL HEUX WIRE ON i/8" CENTERS, ENCAPSULATED IN A CONTINUOUS SOFT VINYL FILM, JOINED BY MOLECULAR WELDING TO FORM AN AIR TIGHT INNER CORE. THE CORE 15 TO BE INSULATED WITH FIBERGLASS INSULATION (R -6), AND SHEATHED IN A REINFORCED, ALUMINUM METALIZED POLYESTER VAPOR BARRIER JACKET. PROVIDE SPIN COLLAR WITH DAMPER AND EXTRACTOR WHERE FLEXIBLE DUCT 15 CONNECTED TO RECTANGULAR DUCTWORK. DAMPER ACTUATOR SHALL BE EXTENDED OUT5IDE INSULATION. 4. AIR CONDITIONING SUPPLY AND RETURN DUCTWORK SHALL BE 1 -1/2" (R -6 MIN.) FIBERGLASS U.L. 151 LISTED, CLASS I AIR DUCT. DUCTWORK SHALL BE FABRICATED IN ACCORDANCE WITH 5.M.A.C.N.A. STANDARDS. (R -6 TOP LEVEL. R -4.2 IN OTHER LEVELS). 5. TEMPERATURE CONTROL SHALL BE A ROOM THERMOSTAT FOR HEATING /LOLLING WITH STAGES AS REG2U I RED. 6. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION AND IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES AND STANDARDS. 1. MECHANICAL CONTRACTOR SHALL VERIFY DIRECTION OF EXISTING STRUCTURE BEFORE INSTALLATION OF EQUIPMENT AND DUCTWORK. SHOULD ANY DISCREPANCIES BE FOUND CONTACT ARCHITECT/ENGINEER. .5. VIBRATION ISOLATION: ALL EQUIPMENT AS PER MANUFACTURER RECOMMENDATIONS TO ELIMINATE ANY EQUIPMENT NOISE FROM BEING HEARD. cl. GUARANTEES: A. ALL COMPRESSOR MOTORS ON NEW EQUIPMENT FURNISHED UNDER THI5 CONTRACT SHALL HAVE A 5 YEARS PRODUCT GUARANTEE FROM DATE OF 5TART -UP. B. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN I YEAR FROM DATE OF ACCEPTANCE. 10. TESTING: A. ALL REFRIGERANT HIGH SIDE PIPING TO BE 300 P510. LOW SIDE TO 150 P515. AFTER TESTING, EVACUATE 5Y5TEM TO 2&% MERCURY GAUGE PRESSURE WITH VACUUM PUMP. HOLD FOR 25 HOURS WITH PUMP OFF. BREAK VACUUM WITH REFRIGERANT. B. BALANCE AIR SYSTEM TO DELIVER QUANTITIES AT EACH OUTLET WITHIN 5% U51N6 A.A.B.C. PROCEDURES AND TESTS. SUBMIT AIR BALANCE TEST RESULTS FOR APPROVAL PRIOR TO FINAL INSPECTION. II. REFRIGERATION SUCTION PIPING SHALL BE INSULATED WITH 3/4" IN- COAFLEX. ARMAFLEX INSULATION MAY ONLY BE USED IN NON - PLENUM AREAS. FINISHED WHERE EXPOSED WITH 2 COATS OF WHITE LATEX PAINT AS PER MANUFACTURER'5 INSTRUCTION. 12. ALL REFRIGERANT PIPING SHALL BE TYPE "K" HARD COPPER, TOGETHER W1TH WROUGHT COPPER SOLDER FITTIN55. JOINTS SHALL BE MADE WITH SILVER SOLDER OR "51LF05 ". ALL CONDENSATE DRAIN PIPING TO BE SCHEDULE 40 TYPE II HIGH IMPACT PVC WITH SLIP JOINT FITTING OF THE SAME MATERIALS WITH AN APPROVED SOLVENT INSTALLED IN A MANNER RECOMMENDED BY THE FITTING MANUFACTURER. 13. ALL WORK SHALL CONFORM WITH THE MECH. BLDG. CODE 2001, 2002 REVISIONS. AND ALL OTHER APPLICABLE STATE AND LOCAL REGULATIONS AND ORDINANCES. CONDENSING UNIT SCHEDULE (EXSTG) UNIT L ❑CATION OUTSIDE UNIT WEIGHT (LBS.) 227 UNIT NOMINAL CAP, (TONS) 3 1/2 MATCHING AHU NUMBER AHU -1 MANUFACTURER RHEEM MODEL NUMBER RAND -042C TOTAL C❑ ❑LING CAP. (BTUH) 40,500 TOTAL SENSIBLE CAP. (BTHU) 28,850 AMBIENT TEMPERATURE 95' UNIT MIN. SEER 13.15 AVAILABLE VOLTAGE 208/230/1 -60 CIRCUIT BKR. MIN. AMPERES 25/25 CIRCUIT BKR. MAX. AMPERES 40/40 SUCTION LINE DIAM. 1 1/8" LIQUID LINE DIAM. 5/16` CALCULED TOT. COOLING CAP, 36,535 AIR HANDLING UNIT SCHEDULE (EXSTG) UNIT NUMBER &RU, -1 MATCHING CONDENSING UNIT CU -1 MANUFACTURER RHEEM MODEL NUMBER RCHJ -48A1 UNIT L ❑CATI ❑N CLOSET UNIT TYPE VERTICAL ENTERING AIR TEMP. (clb /wb) 80'/67' EXTERNAL STATIC PRESS, 030 FAN MOTOR 1/3 AVAILABLE VOLTAGE 208/240 -1 -60 NUMBER OF STEPS 1 FILTER TYPE PERMANENT CFM 1,325 HEAT (kw) 8.5 2 240V Lu N `D tJ m m M uw In § —I 11 UJI P . --.� W 3 lU < z N O u- _� Co- 2q APRIL 200q M% 1 t V� i