Loading...
13-905-001P.C. F. i, I.P. NO Lb. q Lot 6 °o b• . Block 5 .b RADI x -f x f • �" o�\c• �- 113.86 , 3' -2° W.F. ' J 4„ C.L.F. 60 J x o? _ x PSS s 1 „ 57,_6rr owl- 25-0 • 7' -0" •r 25'0' \ EXISTING CONCRETE Zp .� �, �10 I`% • , � • . T .. ` EXISTING CBS UTILITY BE DEMOLISHED v, woCk TO DE DEMOLISHED N . , NEW C1 ADDITION; \ UTILITY F.F.E. - 10.02' , /�r ONE STY .; „/ w eE RES. # 6010, �� °RPSS 7s. I55 -10" F.F.E. = 10.02 • `. i $ � '� e X5,0 � ` '� .p 44' -4" NEW LOCATION P\ �G p ELECTRICAL METER �� �� e. JO, C4N OZ \_ w0 MANE ° s- i EXISTING 1,050 GALS CAP Ned E t Nz .\t �° 6� RE ,o0 .. SEPTIC TANK S\ �` LAI I ce `� a 70' -6 "� Fri • -r \ \ �o =a r II C i I r EXISTING 375 SQF TRENCH ' g; DRAIN FIELD C f `. /' P I Lot a CQ� Block 5 00 ELECT. POLE Al t �2, i �A W.M. I �?,' o O OBJECTION Flor da He 11th Miami -Dade County • .. .S.T. IS. & Well Program Appli tion No.: Signature SCOPE OF WORK E SCOPE OF WORK CONSIST OF: EW CBS ADDITION (UTILITY) AND W REAR OPEN TERRACE. NEW EELECTRICAL PANEL, PLUM BIN WOR FOR NEW LAUNDRY FIXTURE. d vwev . 3306.1 protection rec ZONING LEGEND. ZONING: SINGLE FAMILY FOLI : 09- 4025 -020 -0560 HEIGHT (TO RIDGE OF ROOF) NET LAND AREA: 8,895.00 Sqf. LOT COVERAGE (EVERY THING UNDER ROOF): 1,062.00 Sgf.(34.807.) NEW ADDITION: 400.00 Sqf. SETBACKS: REQUIRED: PROPOSED: INTERIOR SIDE: 7' -6" 7' -6" REAR: 25' -0" 38' -1 rr FRONT 25' -0" 30' -9" LEGAL DESCRIPTION. LOT 7 BLOCK 5, OF CAMBRIDGE LAWNS PARK SUBDIVISION, ACORDING TO THE PLAT THEREOF AS RECORD IN PLAT BOOK 50 AT PAGE 4 OF THE PUBLIC RECORDS OF MIAMI -DADE COUNTY, FLORIDA FLOOD LEGEND Additions, Remodeling, Repairs & Combination FOLIO: 09 -4025- 020 -0560 ADDRESS: 6010 SW 61 ST, MIAMI, FL. 33146 LOT /UNIT: 7 BLOCK /BLDG: 5 PLAT BOOK: 50 PAGE: 4 SUBDIVISION: COST OF CONSTRUCTION- SCOPE OF WORK INTERIOR RENOVATION -- COST OF WORK (MUST INCLUDE ITEMIZED LIST): ADDITION- COST OF WORK- SQ,FT. OF CONST. X (47 SQ.FT. LIVING SPACE):$ SQ.FT. OF CONST. X (35 SQ.FT. STORAGE, GARAGE, TERRACE)$ TOTAL COST OF WORK: Lowest Floor Elev.(including Utility Shed New Concrete Adjacent Grade Elevation basement /sunken areas) Elevation Slab (next to the wall of the structure) EXISTING 10.02 FT, NGVD - ---- - - - - 8.92 FT. NGVD PROPOSED 10.02 FT. NGVD ADDITION - -`- 10.02 FT. NGVD 8.92 FT. NGVD THE OWNER OF THIS PROPERTY UNDERSTANDS THAT THE WORK AMOUNT INDICATED ABOVE IS GOING TO BE KEPT ON THE OFFICIAL PERMIT RECORD DURING A SIX (6) MONTH PERIOD FROM THE DATE OF WHICH THE CERTIFICATE OF COMPLETION IS ISSUED. IF ANY ADDITIONAL, REPAIR, RECONSTRUCTION, ALTERATION, ADDITION, REMODELING OR COMBINATION THEREOF IS DONE BEFORE THE CERTIFICATE OF COMPLETION IS ISSUED, OR WITHIN THE TRACKING PERIOD, IT WILL BE CONSIDERED A CONTINUANCE OF THE ABOVE WORK. IF THE PROPERTY IS DECLARED SUBSTANTIALLY IMPROVED OR DAMAGED AND THE FLOOR ELEVATION IS NOT IN COMPLIANCE, THE STRUCTURE WILL BE ELEVATED IN ACCORDANCE WITH CHAPTER 11C OF THE MIAMI -DADE COUNTY CODE. NO TREES CROWN OF ROAD = 8.29 FT NGVD section 3306 protection of pedestr 3306.1 protection rec pedestrians shall be Ited during construction, remodeling and demolition activities chapter and table 33 as required by this signs shall be provided to direct pedestrian traffic. table 3306.1 protection of pedestri height of constructiortance from construction to lot line type of protection required 8 feet or less less than 5 feet construction railings 5 feet or more none more than 8 feet less than 5 feet barrier and covered walkway 5 feet or more, but not more than one- fourth the height of construction barrier and covered walkway 5 feet or more, but between one-- fourth and one -half the height of construction barrier 5 feet or more, but exceeding one --half the height of construction none 3307.1 PROTECTION 'RED. ADJOINING PUBLIC AIVATE PROPERTY SHALL BE PROTECTED FROM DAMAGE DURING CONSTRUCTIIMODELING AND DEMOLITION WORK. PROTECTION MUST BE PROVIDED FOR FOOT'OUNDATIONS, PARTY WALLS, CHIMNEYS, SKYLIGHTS AND ROOFS. PROVISIONS BE MADE TO CONTROL WATER RUNOFF AND EROSION DURING CONSTRUCTI( DEMOLITION ACTIVITIES, THE PERSON MAKING OR CAUSING AN EXCAVA -0 BE MADE SHALL PROVIDE WRITTEN NOTICE TO THE OWNERS OF ADJOINII`_DINGS ADVISING THEM THAT THE EXCAVATION IS TO BE MADE AND THAT TKNING BUILDINGS SHOULD BE PROTECTED. SAID NOTIFICATION SHALL _IVERED NOT LESS THAN 10 DAYS PRIOR TO THE SCHEDULED STARTIN( OF THE EXCAVATION, COMPLY WITH SECTION 3303 OF FBC 2004 DEMOLITION 3303.1 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS AND A SCHEDULE FOR DEMOLITION MUST BE SUBMITTED WHEN REQUIRED BY THE BUILDING OFFICIAL. WHERE SUCH INFORMATION IS REQUIRED, NO WORK SHALL BE DONE UNTIL SUCH CONSTRUCTION DOCUMENTS OR SCHEDULE, OR BOTH, ARE APPROVED. 3303.2 PEDESTRIAN PROTECTION. THE WORK OF DEMOLISHING ANY BUILDING SHALL NOT BE COMMENCED UNTIL PEDESTRIAN PROTECTION IS IN PLACE AS REQUIRED BY THIS CHAPTER. 3303.3 MEANS OF EGRESS. A PARTY WALT_ BALCONY OR HORIZONTAL EXIT SHALL NOT BE DESTROYED UNLESS AND UNTIL A SUBSTITUTE MEANS OF EGRESS HAS BEEN PROVIDED AND APPROVED, 3303.4 VACANT LOT. WHERE A STRUCTURE HAS BEEN DEMOLISHED OR REMOVED, THE VACANT LOT SHALL BE FILLED AND MAINTAINED TO THE EXISTING GRADE OR IN ACCORDANCE WITH THE ORDINANCES OF THE JURISDICTION HAVING AUTHORITY. 3303.5 WATER ACCUMULATION. PROVISION SHALL BE MADE TO PREVENT THE ACCUMULATION OF WATER OR DAMAGE TO ANY FOUNDATIONS ON THE PREMISES OR THE ADJOINING PROPERTY. 3303.6 UTILITY CONNECTIONS. SERVICE UTILITY CONNECTIONS SHALL BE DISCONTINUED AND CAPPED IN ACCORDANCE WITH THE APPROVED RULES AND THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. -1