Loading...
13-905-000w M 1 A M I•DADE m miamidade.gov ATLAS PAGE: M -18 VERIFICATION FORM EXPIRES ONE YEAR FROM DATE ON FORM INV #: 521 6 (P FORM #: 201340017 DATE Water and Sewer PO Box 330316.3575 S. Le Jeune Road Miami, Florida 33233 -0316 T 305 - 665 -7471 10/2/2013 NAME OF OWNER: LILIAN MANZOR RESIDENCE ADDITION- M2013012978 PROPERTY ADDRESS: 601 -0 SW 61 ST - LOT 7 BLK 5 PROPOSED USAGE / EXIST 1,062 SF SFR ADDING 400 SF PER PLANS FOR TOTAL =1,462 SF -RE S ALLOWED TO STAY 1 NO. OF UNITS: ON SEPTIC REPLACES: PREVIOUS EXISTING 1,062 SF SINGLE FAMILY RESIDENCE -CC13 9276937200 USAGE / NO. OF UNITS: PROPERTY LEGAL: ICAMBRID GE LAWNS PARK PB 50 -4 LOT 7 BLK 5 LOT SIZE 8895 SQ FT OR 8209 -0754 0473 5 COC 25838- FOLIO NUMBER: �......_.09- 4025 - 020 - 0560 1 GALLONS PER DAY INCREASE: 0........_..........1 PREVIOUS FLOW: 220 PREVIOUS SQUARE FOOTAGE: 12062 ❑ NEW CONSTRUCTION PROPOSED FLOW: 220 PROPOSED SQUARE FOOTAGE: 1,462: ❑d INTERIOR RENOVATION THIS IS TO CERTIFY THAT THE MIAMI -DADE WATER AND SEWER DEPARTMENT DOES HAVE A(N) _2_ INCH WATER MAIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT PROPERTY, (OR, IF "WILL HAVE ", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF WATER FACILITIES BY THE DEVELOPER UNDER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N /A) SUBJECT TO PROHIBITIONS OR RESTRICTIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS OF WATER SUPPLY OR WITHDRAWAL. Antonio Raide - New Business BY: Representative SIGNATURE OF REPRESENTATIVE AUTHORIZED BY NEW BUSINESS COMMENTS: �NNI- VF =30.00 -VF VALID ONLY W /PAID INVOICE -CUST RESPONSIBLE FOR 1NEW /RENEWED SERVICE _.......... __ ....................................... __ ............... ... _.. ........... __.. _ _ __ ... ............ _ _ __ ... .......... ..... ... .. .... ... .................. PLANS REVIEW COMMENTS: I CRITERIA: NNI THIS IS TO CERTIFY THAT THE MIAMI -DADE WATER AND SEWER DEPARTMENT DOES NOT HAVE A(N) --- INCH GRAVITY SEWE AIN ABUTTING THE SUBJECT LEGALLY DESCRIBED PROPERTY. WE ARE WILLING TO SERVE THE SUBJECT PROPERTY, "WILL HAVE ", UPON PROPER CONVEYANCE AND PLACEMENT INTO SERVICE OF SEWER SEWER FACILITIES BY THE DEV LOPER UNDER AGREEMENT WITH THE DEPARTMENT, (AGREEMENT ID # N/A). SUBJECT TO PROHIBITIONS OR RE RICTIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION OVER MATTERS OF SEWAGE DISPOSAL. FURTHERMO , APPROVAL OF ALL SEWAGE FLOWS INTO THE DEPARTMENT'S SYSTEM MUST BE OBTAINED FROM D.E.R.M. THE ANTIC ATED DAILY WATER AND /OR SEWAGE FLOW FOR THIS PROJECT WILL BE: NO GALLONS [0] GALLONS PER DAY INCREAS . BY: SIGNATURE OF REPRESENTATIVE NEW BUSINESS COMMENTS PLANS REVIEW COMMENTS: CONTACT NAME: CONTACT PHONE: AUTHORIZED BY: � I/ fie, Antonio Raide - New Business Representative AUTHORIZED BY (SEPTIC APPROV AP1123621 -E DATED) 1/15/2013 - CUSTOMER ALLOWED TO STAY ON 1SEPTIC, SEE DER INOR REVIEW 2013 -240 DATED 11/12/13 ....._. .. ...... _............ _ ___ __._ ... ...... _ _ ..._ .............. ........ _I 'd Printed On: 12/17/2013 10:10:15 AM NB: Antonio Raide PR: C UNTY November 12, 2013 Luis Ojeda 12829 SW 54 Street Miami, FL. 33175 RE: Application for Minor Departmental Review Plans Process #M2013012978 Interior renovations to existing SFR 6010 SW 61 Street Miami, FL 33146 Regulatory and Economic Resources Environmental Plan Review 11805 S.W. 26 Street (Coral Way) Room 124 Miami, Florida 33175 -2474 T786-315-2800 F 786 - 315 -2919 miamidade.gov /development Legal Description: CAMBRIDGE LAWNS PARK PB 50 -4 LOT 7 BILK 5 LOT SIZE 8895 SQ FT PR 8209 -0754 0473 5 COG 25838 -4958 07 2007 1 FO LIO(s): 09- 4025 - 020 -0560 Minor Departmental Review No.: 2013 -240 The Environmental Plan Review section has reviewed the referenced submittal for the subject property. After reviewing your proposal, it has been determined that the same does not meet the requirements of Section 24- 43.1(7) of the Miami -Dade County Code. Said Code Section requires when an approved sanitary sewer is made available and operative in a public right of way or easement abutting the property, any existing individual sewage disposal system, device or equipment shall, within ninety (90) days, be abandoned and the sewage waste from the residence or building be discharged into the sanitary sewer. The review of the above captioned plans revealed that an 8 -inch sanitary sewer gravity main abuts the subject site along SW 62 St. Furthermore, the Miami -Dade Water and Sewer Department (MDWASD), which is the utility company that serves this area, has determined that said sanitary sewer main is available for connection. Consequently, this office will issue a Notice of Service Availability (NOSA) to the public sanitary sewer system, as provided for in the aforesaid Code Section. Based on the available information provided and historical records for the above referenced property, it has been determined that the facility complies with the sewage loading requirements as defined in Section 24- 43.1(3) of the Miami -Dade County Code; accordingly, an administrative approval can be granted to allow the interim use of an on -site sewage treatment and disposal system (OSDS) contingent on the following: tf w g G-, & em tlrf 1. The operations specific to those associated with the above referenced facility cannot be changed from single family residence without prior approval from the Miami -Dade County Department of Regulatory & Economic Resources (RER). If you require additional information or have any questions about the information provided; please contact Yuly Hernandez of this office at (786)315 -2805. Sincerely, �V� I Cristian Guerrero, P.E. a ate` Chief, Environmental Plan Review Department of Regulatory & Economic Resources cc: Oscar Aguirre, Engineer 3, RER Owner's Name: LILLIAN MANZOR a Owner's Address: EEOS Allocation Number: 2013 - ALLOCATION -02973 Project: Lilian Manzor residence /M2013012978 Proposed Use: ADD 400SQFT TOTAL OF 1462SQFT CONNECTING TO GRAVITY SEWER. Pump Station: 30 -0177 Projected NAPOT: 5.12 0940250200560 / 6010 SW 61 ST 220 APP 9/30/2013 N/A I 12/29/2013 �k 3 y A Page 2 of 2 r a f Emiliano Orono, P.E. Fl. P.E. No. 66341 817 SW 122 Ave. Miami, Fl. 33175 Tel. (786)- 715 -7125 STRUCTURAL CALCULATIONS New Addition at 6010 SW 61" St. Miami, Fl. 33146 TABLE OF CONTENT DESCRIPTION N oo, �� �,� g0 Gip pZ 2. Gra t Load Calculation & Uplift Calculation �, gv`�O�RP� SeG1JON 3. Isolated Footling Calculation. svr -- 4. Reinforcing for Continuous Wall Calc, 5. Steel Beam Calculation.;�,Li` =� fj 4� �'•�� i f`,i PAGES 1 -5 6 -8 9 10-11 12 r ' MECAWind Version 2.1.0.6 per ASCE 7 -10 Developed by MECA Enterprises, Inc. Copyright 2013 www.mecaenterprises.com Date 8/14/2013 Project No. Company Name Designed By EMILIANO OROZCO Address Description ADDITION FOR RESIDENCE City Customer Name LILLIAN MANZOR State Proj Location 6010 SW 61 ST. MIAMI, FL File Location: F: \LDHOME \1.- DRAWINGS \l LDHOME \l PROJECTS \DANIEL CORREA\CALCS\WIND LOAD CALC.wnd Envelope Procedure per ASCE 7 -10 Chapter 28 Part 1 All pressures shown are based upon ASD Design, with a Load Factor of .6 Basic Wind Speed(V) = 175.00 mph Structural Category = II Exposure Category = C Natural Frequency = N/A Flexible Structure = No Importance Factor. = 1.00 Kd Directional Factor = 0.85 Alpha = 9.50 Zg = 900.00 ft At = 0.11 Bt = 1.00 Am = 0.15 Bm = 0.65 Cc = 0.20 1 = 500.00 ft Epsilon = 0.20 Zmin = 15.00 ft Slope of Roof = 1.53 : 12 Slope of Roof(Theta) = 7.28 Deg Ht: Mean Roof: Ht = 10.00 ft Type of Roof = Gabled RHt: Ridge Ht = 11.50 ft Eht: Eave Height = 8.50 ft OH: Roof Overhang at Eave= 2.00 ft Roof Area = 2180.00 ft^ 2 1 Bldg Length Along Ridge = 46.00 ft Bldg Width Across Ridge= 43.00 ft Gust Factor Category I Rigid Structures - Simplified Method Gustl: For Rigid Structures (Nat. Freq. >l Hz) use 0.85 = 0.85 Gust Factor Category II Rigid Structures - Complete Analysis Zm: 0.6 *Ht = 15.00 ft lzm: Cc *(33 /Zm) ^0.167 = 0.23 Lzm: 1 *(Zm /33) ^Epsilon = 427.06 ft Q: (1/(1 +0.63 *((B +Ht) /Lzm) ^0.63)) ^0.5 = 0.92 Gust2: 0. 925*(( 1+ 1.7 *lzm *3.4 *Q) /(1 +1.7 *3.4 *lzm)) = 0.89 Gust Factor Summary Not a Flexible Structure use the Lessor of Gustl or Gust2 = 0.85 Table 26.11 -1 Internal Pressure Coefficients for Buildings, GCpi GCPi : Internal Pressure Coefficient = +/ -0.18 1 Low Rise Bldg Provisions per Fig. 28.4 -1: MWFRS Load Case A U Building GCpf +GCpi Surface psf psf -- - - - - -- 1 - - -- -- 0.42 - - - - -- 0.18 2 -0.69 0.18 3 -0.39 0.18 4 -0.31. 0.18 1E 0.64 0.18 2E -1.07 0.18 3E -0.55 0.18 4E -0.46 0.1.8 1T * .00 2T * .00 3T * .00 4T * .00 WnAs!d Comer �nQV+ Load Case A �.?�Wndweni t?otrpr %,UNU A 1001UR Ma Transverse Direction -GCpi qh Pressure - - - - -- psf psf -0.18 --- - - -- -- 33.94 --- - -- - -- 20.36 -0.18 33.94 16.00 -0.18 33.94 16.00 -0.18 33.94 16.00 -0.18 .33.94 27.83 -0.18 33.94 16.00 -0.18 33.94 16.00 -0.18 33.94 16.00 * * .00 * * .00 * * .00 * * .00 2 Low Rise Bldg Provisions per Fig. 28.4 -1: MWFRS Load Case B Comor ()r?r3or xno \' �Yi Jirr1+►� Costa Load Case's WWj V'i l`f f ` , ' Case B Torsion �,r n S I� D03cm. Longitudinal D'oredon 3 Building GCpf +Gcpi -Gcpi qh Pressure Surface -- - - - - -- = Psf Psf 1 --- - - - -- -0.45 - -- - - 0.18 - - -- --- - - - - -- -0.18 --- - - - - -- 33.94 --- - - - - -- -21.38 2 -0.69 0.18 -0.18 33.94 -29.53 3 -0.37 0.18 -0.18 33.94 -18.67 4 -0.4.5 0.1.8 -0.18 33.94 -21.38 5 0.40 0.18 -0.18 33.94 19.69 6 -0.29 0.18 -0.18 33.94 -15.95 lE -0.48 0.18 -0.18 33.94 -22.40 2E -1.07 0.18 -0.18 33.94 -42.43 3E -0.53 0.18 -0.18 33.94 -24.10 4E -0.48 0.1.8 -0.18 33.94 -22.40 5E 0.61 0.18 - 0.18 33.94 26.81 6E -0.43 0.1.8 -0.18 33.94 -20.70 1T * * * .00 2T *. * * .00 3T * * * * .00 4T * * * .00 5T * * * * .00 6T * * * * .00 Figure 28.4 -: Low Rise Wal And Roof Figure Notes: Notes: 1) Pressure = qh * (GCPf - ( +/- GCpi)), only max value shown 2) For Torsional Load Cases, the zones are designated with a "T ". The pressures(Min P & Max P) are 25% of the full design wind pressures(Ld Case 1T= 25 % *1(ld case 1 ),2T= 25% *2,3T= 25 % *3,4T= 25 % *'4). Exceptions to Torsional Load Cases: One story buildings with mean roof height- < =30 ft(9.1m), buildings with two stories or less framed with light frame construction, and buildings two stories or lef.s designed with flexible diaphragms need not be designed fci the Torsional Load Cases. (Note 5 of Figure 6 -10) 4 MECAWind Version 2.1.0.6 ASCE 7 -10 Developed by MECA Enterprises, Inc. Copyright 2013 www.mecaenterprises.com Date 8/14/2013 Project No. Company Name Designed By EMILIANO OROZCO Address Description ADDITION FOR RESIDENCE City Customer Name LILLIAN MANZOR State Proj Location 6010 SW 61 ST. MIAMI, FL File Location: F: \LDHOME \1.- DRAWINGS \l LDHOME \l PROJECTS \DANIEL CORREA \CALLS \WIND LOAD CALC.wnd 1' df f_. 5' I k Walls 1 i a i 1 I 1 I I 1 I I 1 1 1 I I 1 1 I I 1 1 I I 1 I I I 1 I I I 1 1 I i 1 1 i I 1 I Gable Roof 1 <: 0 <= 4-5 Wind Pressure on Components and Cladding (Ch 30 Part 1) All pressures shown are based upon ASD Design, with a Load Factor of .6 Khcc:Comp. & Clad. Table 6 -3 Case 1 Qhcc:.00256 *V ^2*Kricc *Kht *Kd = 0.85 33.94 psf 5 Width of Pressure Coefficient Zone "a" = 4 ft Description Width Span Area Zone Max Min Max P Min P -------------------------------------------------------------------------- ft ft ft "2 GCp GCp psf psf TYP TRUSS 2.00 27.42 250.6 1 0.30 -0.80 16.29 -33.26 TYP TRUSS 2.00 27.42 250.6 2 0.30 -1.20 16.29 -46.84 TYP. TRUSS 2.00 27.42 250.6 3 0.30 -2.00 16.29 -73.99 OUTLOCKER 2.00 9.17 28.0 1 0.41 -0.86 20.04 -35.14 OUTLOCKER 2.00 9.17 28.0 2 0.41 -1.48 20.04 -56.21 OUTLOCKER 2.00 9.17 28.0 3 0.41 -2.33 20.04 -85.24 CBS WALL 4.00 9.00 36.0 4 0.81 -1.00 33.66 -40.11 CBS WALL 4.00 9.00 36.0 5 0.81 -1.20 33.66 -46.96 GIRDER TRUSS 5.00 27.42 250.6 1 0.30 -0.80 16.29 -33.26 GIRDER TRUSS 5.00 27.42 250.6 2 0.30 -1.20 16.29 -46.84 GIRDER TRUSS 5.00 27.42 250.6 3 0.30 -2.00 16.29 -73.99 Khcc:Comp. & Clad. Table 6 -3 Case 1 Qhcc:.00256 *V ^2*Kricc *Kht *Kd = 0.85 33.94 psf 5 Gravity and Uplift Calculation Lillian Manzor Typ Truss 2 "x4" Wood Typ. Truss @24" o.c. Loads: Span Length 27.42 ft DL: 25 psf Spacing: 2 ft LL: 30 psf Area: 31.42 sqf Overhang: 2 ft a: 4 ft Total Load: 55 psf Wind press. Zone 1: 33.26 psf Wind press. Zone 2: 46.84 psf Wind press. Zone 3: 73.99 psf Reactions: Gravity: Total Load x Area = Uplift: A1= (Span /2 + Overhang - a) x Spacing x (33.26 -10) _ A2 =(a x Spacing) x (46.84 -10) _ TOTAL UPLIFT A1+A2: A3 =(a x Spacing) x (73.99 -10) _ TOTAL UPLIFT A3: 1,728.10 pounds 544.75 pounds 294.72 pounds 839.47 pounds pounds 511.92 511.92 pounds m Gravity and Uplift Calculation Lillian Manzor Girder Truss 2 "x4" Wood Girder Truss: Loads: DL: 25 psf LL: 30 psf Total Load: 55 psf Span Length 27.42 ft Spacing: 5 ft Area: 78.55 sqf Overhang: 2 ft a: 4 ft Wind press. Zone 1: 33.26 psf Wind press. Zone 2: 46.84 psf Wind press. Zone 3: 73.99 psf Reactions: Gravity: Total Load x Area = Uplift: A1= (Span /2 + Overhang - a) x Spacing x (33.26 -10) _ A2 =(a x Spacing) x (46.84 -10) _ TOTAL UPLIFT A1+A2: A3 =(a x Spacing) x (73.99 -10) _ TOTAL UPLIFT A3: 4,320.25 pounds 1,361.87 pounds 736.80 pounds 2,098.67 pounds pounds 1,279.80 1,279.80 pounds 7 Gravity and Uplift Calculation Lillian Manzor Outlocker 2 "x6" Wood Outlocker @24" o.c. Loads: Span Length 9.17 ft DL : 25 psf Spacing: 2 ft LL: .30 psf Area: 13.17 sqf Overhang: 5 ft a: 4 ft Total Load: 55 psf Wind press. Zone 1: 35.14 psf Wind press. Zone 2: 56.21 psf Wind press. Zone 3: 85.24 psf Reactions: Gravity: Total Load x Area = 724.35 pounds Uplift: A1= (Span /2 + Overhang - a) x Spacing x (35.14 -10) = 280.81 pounds A2 =(a x Spacing) x (56.21 -10) = 369.68 pounds TOTAL UPLIFT Al +A2: 650.49 pounds pounds A3 =(a x Spacing) x (85.24 -10) = 601.92 TOTAL UPLIFT A3: 601.92 pounds s Isolated Footing Lillian Manzor 48 "x48 "x16" Tributary area: 130 Sqf (worst case) Kd =0.85 0.6 DL +1.OWL Loads: DL: Footing: Steel Column: Steel Beam: Roof Concrete Slab 4'x4'x1.33'x150 12.21 lb/ft x 9' 13.21 lb/ft x 9.75' 25 psf x 130 Sqf 4'x4'x0.67'x150 SUB -TOTAL LOAD x 0.6: LL: 30 x 130 Sqf TOTAL LOAD: Soil Bearing Capacity: 3,192.00 pounds 109.89 pounds 128.80 pounds 3,250.00 pounds 1,608.00 pounds 4,973.21 pounds 3,900.00 pounds 8,873.21 pounds 2,000.00 psf Footing area req: 8,873.21 = 4.44 ft2 2,000.00 Footing area provided:4'x4' = 16.0 ft2 Kd = 0.85 Verifying Wind Load: 33.26 Ibs /ft2 x 1.0 x 130 sqf = 4,323.80 Ibs > 4.44 OKII < 4,973.21 OKH REINFORCING FOR CONTINUOUS WALL Reinforcement at mid -depth Lillian Manzor Specified Thickness, t 7.625 in. Self Weight 60 psf fn, (specified masonry compressive strength) 1,500 psi fy (yield strength of steel) 60,000 psi f�„ (net area compressive strength of CMU) 1,900 psi E, (modulus of elasticity of masonry in comp) 1,350,000 psi ES (modulus of elasticity of steel) 29,000,000 psi d =t/2 3.8125 in. n = Es /Em (modular ratio) 21.48 Wall Height (h) 9 ft Wind Pressure (P) 40.11 psf Emu maximum usable compression strain Emu tensile strain in reinforcement DESIGN FOR FLEXURE Moments are due to wind loads only as a result that the wall is non load bearing and gravity loads are concentric. Tributary Area (= h2 /3) or (= @ x h) GCp (zone 4 & 5 windward) GCp (zone 4 leeward) GCp (zone 5 leeward) Masonry located on zone Wind Pressure Mu = 1.6 "P(h)2 /8 36.00 ft. 2 0.85 -0.86 -1.65 4 -41.85 psf 677.98 lb-ft Estimated Required Reinforcement As =Mu /00.9dfy = 0.044 in` /ft try No. 5 @ 1 48 in o.c. As provided 0.0775 in2 /ft OK! Check Maximum Reinforcement Make sure the designed flexural reinforcement does not exceed the maximum. Neglect the small axial load due to self weight. As max 0.BPi F'm x 0.a0d Emu b Nu -(1.25 '�!) ( BE9 + Emu) As max = 0.282 in2 /ft SATISFACTORY DESIGN! As max > As provided REINF. OF CONT. WALL 10 � � f Lillian Manzor REINFORCING FOR CONTINUOUS WALL Design for Shear Vu= 1.6 *P *h /2 Vu = 301.32 lb/ft Nominal Shear Capacity Vn = [4-0 - Lis ( i /� Ar. J "- 0.25F \ Vow / The most conservative (lowest) value of Vn is obtained when MNdv =1. Also the axial load P can conservatively be taken as zero. Vn = 2.25 /�r - An= 40.7 in2 /ft OVn = 2837 lb/ft Vu <0Vn SATISFACTORY DESIGN! Vn < 4 A�, Jr OK! REINF. OF CONT. WALL 11 � v T'W'x1/4" Steel Beam: Loads: DL: 10 psf LL: 30 psf Beam weight: W = 553.91 lb /ft Beam Properties Fy= 36000 psi Fb = 23760 psi A = 3.84. in' 1.= 17 in' SX= 5.66 i n 3 E = 29000000 1 psi Check Stress Bending Moment: 13.91 p!f Lillian Manzor Steel Beam M = 1/8 w' L2 = 9284.67 lb-ft 111416.005 1b -in. Span Length: 11.58 ft (worst case) Spacing: 13.5 ft Required Section Modulus: S(req.) = M / Fb = 4.69 in < Bending Stress: fb = M /Fb = 19684.8066 psi < Check Deflection: 5 *w *L4 0.455 in. 384 *E *I 5(;,,,()w) = L/180 = 0.772 in OK!! 31' 1/4" thk. N.A. 5.66 OK!! 23760 OK!! 12 n�* ror+r rra (R n sr�r�rw— w�a ..niaL (W) (Pon- . 1. C�77!►�D tqt �aaie■N fmoswf=sr.�au�aw.> i "tars araec t q �eu�rus�r. / �AiQ1LR l�N./Nmw��►JNfAQl..flJflwL a/wi/Ri wIWASaUMM I lOFOG&AP= stwm PLOOD ZOAB nVPVXAlA27ON aw m vma tw-e o I aragww� www I �ssawwma� 'Air I M �/!ia►J��Aaai /b /lW a/ zcBa6 f llf /N /1/t f@►7/! I,tMM �L v®v�NM a {!M ' �tt � L• '� ^_MAfYTI M� ME wr wrors CAMS= i<i r n. wa.. a... em.i.,....as.,.rnsw...wi.wumonu w�v — ewi�ww�awrgwwa�rwr�ar�r�ewsewrr + w�ww�rww�osaww ,tsswwtwssmsNaww�ww wewsw�r ..�� Avnlfa /�MMAwN� saewwvwsr�wesivswRwwwww�wr:w �araaNl� —w�eMwwa MIGLW ESPINaU LAND SURVEYING, Mr. lwujwnmM -�Jlll AffomizoAm Dili li t1