13-1256-001� I 111 Y 1. CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENTS TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION, EXAMPLEx IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, AND THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWING CONNECTION, THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATION. CONTRACTOR IS RESPONSIBLE FOR PROVIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OWNER. 2. CONTRACTOR IS RESPONSIBLE FOR VISITING TI-E SITE DURING THE BIDDING PERIOD, AND VERIFY THAT CONDITIONS ARE AS DESCRIBED IN THE DOCUMENTS, DISCREPANCIES ARE TO BE NOTED IN WRITING, AND ARCHITECT/ENGINEERS, NOTIFIED. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK, AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3. DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CONTRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK, AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED, IF AT THE DISCRETION OF THE OWNER OR T14E ARCHITECT THE WORK HAS TO BE RE -DONE. 4. SHUTDOWN OF UTILITIES: IF A SHUTDOWN OR ANY TYPE OF INTERFERENCE WITH EXISTING SYSTEMS IS ANTICIPATED, THE CONTRACTOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE, AND OBTAIN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS, AND USE ALL APPROPRIATE CONSTRUCTION METHODS /TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION, AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND TI-E SPECIFICATIONS, THE CONTRACTOR SHALL OBTAIN CLARIFICATIONS DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION, IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY, AND WILL DO THE WORK AS PER THE DIRECTIONS OF THE OWNER / ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7. ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COMMON USE. ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENTS TO PROTECT THE SAFETY OF ALL PERSONS AND THE PROPERTY THROUGHOUT THE ENTIRE PERIOD OF THE CONSTRUCTION CONTRACT. 9. THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENTS WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10. ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED 1 -REIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. II. PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METALS AND ALSO BETWEEN CEMENT AND METAL. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13. CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS, AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS, AND BRING ANY NONCONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION. 14. GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK OR EQUIPMENT DAMAGED DUE TO WORK PERFORMED, SHALL BE REPAIRED /REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTI- ERWISE NOTED), 15. DRAWINGS ARE SCHEMATIC, SHOWING RELATIVE LOCATIONS AND CONNECTIONS, AND SHALL NOT BE SCALED AT ANY TIME 16. ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE-RETARDANT TREATED AS PER SPECIFICATIONS. 17. GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS/PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18, ELEVATIONS AND LEVELS: A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19. ALL INTERIOR GYPSUM WALL BOARDS ARE 5/8' TYPE 'X' G.W.B. ON METAL STUDS OR FURRING CHANNELS, UNLESS NOTED OTHERWISE. SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTE NUMBER '9' FOR LOCATION OF WATER RESISTANT G.W.B. 20. PROVIDE WATER RESISTANT TYPE 'X' G.W.B. IN ALL TOILETS AND JANITOR`S CLOSETS. 21. BEFORE PATCHING ANY FIRE-RATED C.M,U. PARTITION, FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22. PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASE WORK. 23. LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATIONS OF ACCESS PALLS PRIOR TO INSTALLATION. 24. THERE SHALL BE NO BACK- TO-BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25. ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS, SHALL. BE FURRED WITH METAL STUDS AND DRY WALL, AND FINISHED TO MATCH ADJACENT WALLS, U.N.O. D(CEPTIONS, A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26. WHERE VAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE, AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.C. MATERIAL. 27. SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SIEF ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING - MOUNTED MECHANICAL /ELECTRICAL FIXTURES. 29. STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS, EACH SIDE, JOINTS STAGGERED MINIMUM 2' -O' U.O.N. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A. FIRE PROTECTION REQUIREMENTS. CONTRACTOR SHALL PROVIDE ALL NECESSARY INSULATION/FIRE PROTECTIVE COATINGS. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWINGS TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT. 0001 S.W. 70th STREET UNIT 105 TEL: (305) 284-7504 NOVEMBER 1, 2013 GUIROLA & ASSOCIATES P.A. CONSULTING ENGINEERS CA 00009112 P.E. No 57468 David Guirola Electrical Engineer 1150 NW 72nd AVE, S -512 MIAMI, FLORIDA 33126 P.H: (305) 513 -9665 EMAIL: GUIRO 5@AOL.COM AM] M! V M 5) F, qAA th " _ SW 88th St 66th t , y M° ° PROJECT SITE _ ao w c� 69t �- SV1d 6h St a 5W 69th St CrP ' >.. Im z r . 701h St AREAm ,'M34th 1 A, SW 70th �t 477G " s s i i w? . H , Best Larklit Larkin P Best Miami Miami ouE1 Hospital . :SttiOn Rail 14 . ithbound I 4� nset r Sunset Of SW 72nd St SunseIt Dr SW 1 - Su n set Dr ._ of Casa Lary �. Casa Laaos I i3(d St AM] M! V M 5) F, qAA FAX: (305) 284 -7545 a A A O • ,arc e c t s FLORIDA LICENSE #AA0002689 2100 Ponce de Leon Blvd. Suite 1170, Coral Gables, Florida 33134 Tel: (305)265 -7177 Fa m (305)262 -8435 LUIS E. NAYX A.I.A FL AR0008063 !?ROJECT NUMBER: 201204 16 it AM ORIGINAL BUILDING DESCRIPTION BUILDING JURISDICTION: PRIMARY USE CLASS: CONSTRUCTION TYPE (NFPA): CONSTRUCTION TYPE: NUMBER OF STORIES: CITY OF SOUTH MIAMI BUSINESS TYPE I (221) TYPE I, FLORIDA BUILDING CODE 1 FLOOR NEW PROJECT DESCRIPTION PROJECT AREA: SPRINKLED: TOTAL 1,059 SQ. FT. FULLY SPRINKLERED APPLICABLE CODES • FLORIDA 1 1 CODE 1 1 • FLORIDA i' E PREVENTION CODE 2010 EDITION. 101 LIFE SAFETY CODE, il• EDITION D D D D D D D D D D INDEX OF,.---DRAWINGS CS -1 COVER SHEET. FIRST 1i DEMOLITION • PROPOSED FLOOR r ACCORDION DETAIL, LEGEND AND NOTES. A-3 SECTIONS, INTERIOR ELEVATIONS, TYPICAL RESTROOM PLAN AND DETAILS. ►,i• SCHEDULE, •► r► ULE, PARTITION TYPES, FINISH SCHEDULE, LEGEND AND DETAILS. TYPICAL , MECHANICAL M -1 MECHANICAL PLAN, LEGEND AND NOTES. PLUMBING P -1 PLUMBING PLAN, LEGEND AND NOTES. FP -1 SPRINKLER PLAN, LEGEND AND NOTES. ELECTRICAL E -1 POWER PLAN, LIGHTING PLAN, FIRE ALARM NOTES, ELECTRICAL SPECIFICATION, ELECTRICAL RISER, LEGEND AND NOTES. "q'qy 0IIa.� as I I I_E: . . S R sC °U -1 r•arx .c.. - ` SYY BRs St cn SW Both St SlM1dw6t#ih St _ ao w c� SV1d 6h St a 5W 69th St CrP >.. Im PROJECT AREAm SW 70th St .� A, SW 70th �t SW 76th St 4 - ua s r� 15 w? . H , Best Larklit : P•Elar l CammuniTy 'Hospital p. South C.;�ami Station Rail . ratthe ®und LW & itn sz SW 72nd St SunseIt Dr SW 1 Su n set Dr ._ v Casa Laaos I r f SW 73rd St ....1I , ;W 73rd St N SW i - p ,. w - SW 74tta_t i J Ten6 Plaza SW 74th St _ ... . H r South Pdlaml Hospital P ,t SV'J,76 76th St FAX: (305) 284 -7545 a A A O • ,arc e c t s FLORIDA LICENSE #AA0002689 2100 Ponce de Leon Blvd. Suite 1170, Coral Gables, Florida 33134 Tel: (305)265 -7177 Fa m (305)262 -8435 LUIS E. NAYX A.I.A FL AR0008063 !?ROJECT NUMBER: 201204 16 it AM ORIGINAL BUILDING DESCRIPTION BUILDING JURISDICTION: PRIMARY USE CLASS: CONSTRUCTION TYPE (NFPA): CONSTRUCTION TYPE: NUMBER OF STORIES: CITY OF SOUTH MIAMI BUSINESS TYPE I (221) TYPE I, FLORIDA BUILDING CODE 1 FLOOR NEW PROJECT DESCRIPTION PROJECT AREA: SPRINKLED: TOTAL 1,059 SQ. FT. FULLY SPRINKLERED APPLICABLE CODES • FLORIDA 1 1 CODE 1 1 • FLORIDA i' E PREVENTION CODE 2010 EDITION. 101 LIFE SAFETY CODE, il• EDITION D D D D D D D D D D INDEX OF,.---DRAWINGS CS -1 COVER SHEET. FIRST 1i DEMOLITION • PROPOSED FLOOR r ACCORDION DETAIL, LEGEND AND NOTES. A-3 SECTIONS, INTERIOR ELEVATIONS, TYPICAL RESTROOM PLAN AND DETAILS. ►,i• SCHEDULE, •► r► ULE, PARTITION TYPES, FINISH SCHEDULE, LEGEND AND DETAILS. TYPICAL , MECHANICAL M -1 MECHANICAL PLAN, LEGEND AND NOTES. PLUMBING P -1 PLUMBING PLAN, LEGEND AND NOTES. FP -1 SPRINKLER PLAN, LEGEND AND NOTES. ELECTRICAL E -1 POWER PLAN, LIGHTING PLAN, FIRE ALARM NOTES, ELECTRICAL SPECIFICATION, ELECTRICAL RISER, LEGEND AND NOTES. "q'qy 0IIa.� as I I I_E: . . S R sC °U -1