Loading...
12-300-004EL. +10.96' T.O. COPING EL. +10.79' FINISH DECK � WATER LINE' - \r \r\ \\ WADE ENTRY \\ \\ \\ \\ \\ �,\ /\ /\iii\ /\ /\ /\i\i\ /\i �• �ir /i \ i \ri \ri \ri \ /i \ri \ri\ /� POOL t 6" SHOTCRETE WALL REINF. 4 `O I WITH #3 @10" EACH WAY, ENTER STEEL IN WALL U.O.N. 6" SHOTCRETE SLAB REINF. WITH 1:3 SLOPE MAX. 1:7 SLOPE MAX. #3 @10" EACH WAY, 3" CLEAR BOTTOM. \� / \�/ / \\i / \ \r,X \ / /\\ �. . / \ /� / /r\ \jr� r WELL STABILIZED SOIL OR WELL ri rr\�:i%\ \\r \\r�\ 17\1 •\� \\�\ \,�\ \,��, COMPACTED FILL WITH 2000 PSF `//\/ \r iX BEARING VALUE. WELL STABILIZED SOIL OR WELL COMPACTED FILL WITH 2000 PSF /�\r��i \\r // BEARING VALUE. PIPE SIZE PRESSURE FLOW CAPACITY (10FPS) SUCTION FLOW CAPACITY (8FPS) 1.5" 60 gpm 49 gpm 2.0" 100 gpm 80 gpm 2.5" 150 gpm 110 gpm 3.0" 220 gpm 180 gpm PIPE FLOW RATE @ 60 TDH HP 55 gpm 1.0 HP 75 gpm 1.5 HP 90 gpm 2.0 HP 95 gpm 2.5 HP 155 gpm 3.0 HP 140 gpm BASE D UPON STA -RITE MAX -E -GLASS II SELF PRIMING PUMP. #8 SOLID CU 18" MIN. TO 24" MAX. FROM CONTOUR OF POOL 360 DEGREES WITH 4 EQUAL BOUNDING POINTS TO THE POOL STEEL 6' DEPTH MIN. ( ^1 WADE ENTRANCE 6" SHOTCRETE SLAB MAIN DRAIN, REINF. WITH #3 @10" EACH SEE DETAIL. WAY, 3" CLEAR BOTTOM. SECTION 1 1/2" = 1' -0" —� --- — - - — --\ I SWIMOUT --------- - - - --� �--------------- - - - - ---- \ . 1 I 11'" BUBBLER JET LINE VENT. PIPE MAX. LENGTH HP FLOW RATE VENT. SIZE MAX. LENGTH 3/ 55 gpm 1 Y2" 29 LF 1.0 75 gpm 1 y" 40 LF 1.5 90 gpm 1 Y2" 49 LF 2.0 95 gpm 1 Y2" 51 LF 2.5 115 gpm 1 Y2" 62 LF 3.0 140 gpm 1 V2" 76 LF NOTE: -VENT. IS DESIGNED TO EVACUATE SUCTION IN 3 SEC. OR LESS AS PER .B.C. 424. - THIS SAFETY VACUUM RELIEF SYSTEM IS A NON - MECHANICAL VENT. SYSTEM THAT WILL LIMIT THE TRANSMISSION TO SUCTION AT THE OUTLET TO A MAXIMUM OF 4.5" OF MERCURY. POOL PIPING PLAN SCALE: 1/4 " =1' -0" A 48 SOLID CU. A POOL STEEL B REBAR. —. A SAME LEVEL AND TRENCH AS SUPPLY AND RETURN 2 2" VACUUM LINE. 2" SKIMMER LINE. 2 Y2" DUAL POOL MAIN DRAIN LINE. 1 Y2" VENT. LINE TO EQUIP. 2 " POOL RETURN LINE. NORTH APPROVED TO DIRECT BURIAL. #8 SOLID CU . SPLIT BOND APPROVED STEEL. CLAMP. #8 SOLID CU. WATER PIPE TO PUMP. POOL #8 SOLID CU. B EQUIP. ALTERNATIVE DESIGN EQUIVALENT TO NEC 680.26(C) - i POOL EQUIP. LOAD CALCULATION SQUARE FEET OF C_0_NDffION_SPACE 1,802 GENERAL LIGHTING W.S.F Y_� —_ 5,406 _AT _3 GENERALAPPLIANCESAtJD WATER HEATER _ 28,000 POOL P_U_MP AT_1_0_0% � 1,442 1,500 P 00 L ! 5PA L {GHT AT 10090 BLOWER PUMP AT 100 15 0 CONNECTED LOAD WIHTOUT fL'C LOAD 36,348 FIRST 1000 AT 100% 0 _R_..E. ST ... AT _.__4 40% __- _____-.____...___ ____. 14,539 . NEAT i O 'P.._ AT 10090 M..­..... 0 . _ ...... Ar. HEATER LOAD AT 100% ........ ............................... 10,000 TOTAL CONNECTED 24,539 AMPERES 102 36" 0, 4" CONC. TABLE WITH #4 @ 10" O /C. AT TOP EACH WAY. r 12 "0 CONC. COLUMN A ' WITH 4 #4 AND #3 TIE AT 10" T /O. I R I I 'I WELL STABILIZED SOIL OR WELL COMPACTED FILL WITH 2000 PSF BEARING VALUE. CONC. TABLE DETAIL 1/2" = 1' -0" GARrRI pGE X50 ERfit Ulf CVoM " N POOL d% L SKIMMER /IN% N �ENr UN� i POO� , MAU4 UNE / � � I ,Iz MAIN DRAIN 5- x SPAONO 3 Fr MA LINE I �l? rER Ott LINE I'l2' NSA POOL /SPA FILTRATION SYSTEM EQUIPMENT SCHEMATIC NDYSALrSYSTEM. JA ,. REr�RN ELECTRICAL NOTE 1- ALL POOL ELECTRICAL WORK SHALL COMPLY WITH NEC 2004. 2- NO OVERHEAD ELECTRICAL WIRING SHALL BE LOCATED WITHIN 10' OF POOL'S WATER EDGE UNLESS IT 18' OR HIGHER. 3- GROUND ALL BOXES, LIGHTS, MOTORS, LADDERS, ETC. WITH #8 GROUND WIRE. 4- DECK AROUND POOL REQUIRED (4) EQUAL SIDES BONDED WITHIN 3' OF THE RIM. 5- ALL SWIMMING POOL PUMP REQUIRE GFCI BREAKERS AS PER NEC 680.22B. OUTSIDE INSIDE 2 # 12 THWN, 2P -20 AMP 1 # 12 THWN CV GND. PROVIDE GFI EXISTING ELEC. M FILTER PUMP. METER 200 AMP. F_ — — -I _ _ -I I EXISTING I- M O HOUSE co I 1 200 AMP z J I METER I- — — — — o GFI RECEPTACLE 10' L J L — — J CT MIN. 20' MAX. FROM _ ,T_ Lo 1iM o WATER EDGE. a 2 # 12 THWN, 1P -15 15A O C/) o`po [�W7 CZ AMP 1 # 12 THWN �i SW SW CV GND. 3 #2/ 0 THWN (CU) I TX 100 W IN 2" COND. RIGID —� O JB TRANS. I GROUND I 0 Y 54 W — — I — POOL FPL SERVICE I LIGHT 200 AMP POOL ELECTRICAL SCHEMATIC N.T.S WATER LEVEL VARIES (SEE PLAN) COPING 6x12 ADD. TFLAVERTINE ON _ - - COMPACTED SAND (SEE SHEE -1 FOR DETAIL)_ GRADE ^_ z III POOL WELL COMPACTED =� FILL a 01 x'90, FOR THICKNESS 'os S SEE SCHEDULE `''' ��cco S'q� /Gs # 3 @ 10" O.C. EACH WAY SIDES 2 S STEEL TEXT FORM � OR KRAFT FORM . 3 @ 10" O.C. EACH WAY TYPICAL WALL SECTION 1/2" = 1' -0" 3' -0" POOL BOTTOM MAIN DRAIN WITH ANTI - VORTEX GRATE 16 SQ.IN MINIMUM OPEN AREA 2 Y2 "0 SUCTION LINE J 6" (MIN) CONCRETE ALL AROUND DRAIN SUMP HYDROSTATIC RELIEF VALVE 1 )/2"0 x 12" PIPE GRAVELSUMP 1Y2"0 VENT LINE o JUNCTION BOX A PUMP S Q / JB SWI TCH. V `Jw (n Y'� TIMER 100 W �� TRANS. FILTER PUMP MOTOR. DOUBLE MAIN DRAIN DETAIL 1/211 = 1 -011 TO PU 2' -3" - SKIMMER DETAIL 1/2" = 1' -0" PROVIDE DIFFERENT COLOR TILE NON -SLIP AT SWIMOUT E WATER LEVEL " WATER LEVEL SWIMOUT DETAIL 1/2" = 1' -0" JUNCTION BOX. COPING z 5' -0" MIN. ". OF SOUTH MIAMI WATER LINE ao pUILDING DEPT. S oC4UCTURAL SECTIO I LL RE EO �1P t EVED / /•r 1" 0 PVC. I LIGHT NICHE (12 VOLT) TO I' COMPLY WITH S.F.B.C. AND NEC 680. SEE PLAN FOR LOCATION. SWIMOUT DETAIL 1/2" = 1' -0" M M � y_ co z _U N u- CT C) cf Lo co a ,T_ Lo 1iM a 1' 2 O C/) o`po [�W7 CZ �i 0 U 0 Y U w U O U W 1r z U O V m w i U) rL o N N r- Z Z QQ J Z n Z O�/'� Q U V J J z 0 0 M M w J LL U- a Q O w 1.4 O Z . u. u L M to i-+-I U) W O o O W � � O 0 a DATE: FEB. 212, 2012 DRAWN: L.A.H. REVISED A.H. Sheet - SP -2