Loading...
12-300-002w • U z w U- o• LOT 10 0 M Q ELECTRICAL METER II ILL! z w Z 'I U U- z (� z IN r Q lw t CANAL II1 Ix 11 I x II w Ix w LOT 8 IU- )x Y I z I J x z Ix U x I I Ln x IM 0 I x 11 Ix II1 I 1 I I 1 1 S.W 63 rd COURT T50' RNV SITE PLAN iJ SCALE: 1/16 " =1' -0" j LEGAL DESCR;PTIONS LOT 6, BLOCK 44 OF " SOUTH MIAMI HEIGHTS ADDITION V ", ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 86, PAGE 56 OF PUBLIC RECORD OF MIAMI -DADE COUNTY, FLORIDA. GENERAL POOL NOTES. 1- ALL FLOORS AND WALLS OF POOL TO BE GUNITE APPLIED CONCRETE A 28 DAY MINIMUM COMPRESSIVE STRENGYI OF 3000 PSI. 2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 60. 3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL EXCEPT MAIN DRAIN TO BE SCHEDULE 80 PVC 4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 50 OF THE SFBC. 5- NO POOL OR SPA DECK SHALL BEAR ON ANY TYPE OF SOILS EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY ORGANICS, MARLS, OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED) IN THEIR ENTIRETY AND THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS. WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGN FOI PILING. 6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF REQUIRED. THE DESIGN ENGINEER ASSUMES M RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURE. 7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARISO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND / OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL3E HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY IN GENERAL. HOLD A DISTANCE OF 15 FET FROM OVERHEAD ELECTRIC LINES TO OPEN POOL WATER AND 10 FEET FROM UNDERGROUND ELECTRIC LINES. 9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMWSION, W.D.C. 10- MINIMUM 4' -0" HIGH IS FENCE RECOMMENDED AROUND ALL POOLS IN UNSCREENED AREAS. 11- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. TIE WALLS SHALL BE IN GOOD CONDITIONS NOT PERMITTING ANY SHIFTING OR REMOVAL OR LOOSENING OF THE SUPPORTIG SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACD OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE PROPERTY OWNER. WHEN EXCAVATIN FOR THE POOL, THE SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE DEADMEN FALL WITHIN THE EXCAVATN, NOTIFY THE ENGINEER FOR INSTRUCTIONS. 12- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. NCKFILL SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC MATERIALS AND SHALL BE PLACED IN 12" THICKAYERS. EACH LAYER SHALL BE COMPACTED TO 90 % OF THE SOILS MAXIMUM DENSITY BY TAMPING SOLIDLY. SOILS BELO' THE PATIO SHALL BE PLACED IN A SIMILAR MANNER. 13- WHERE PATIOS ARE INDICATED BY OTHERS. THE PATIO DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION D NOT APPLY. PATIO DESIGN SHALL BE BY OTHERS. 14- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC URFT PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO PREVENT THE POOL FROM FLOATING UPWARD. THE O'NER MUST CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURES. 15- THIS PLANS REMAINS THE PROPERTY OF THE DESIGN ENGINEER. IT IS NOT TRANSFERABLE FROM ONE CONTRACDR TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIOAL KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN COMPLIANCE WITH THE SFBC AND ALL APPLICABLE LOAL CODES AND REGULATIONS. 16- TEMPERATURE OF SPA WATER SHALL BE SET SO THE MAXIMUM WATER TEMPERATURE 102 F. o 00 Oa 4 00o QD 0 0 0 00 0 °000000 o 00 °0 D Oo )pQ 0 °op c0 00 0000 0 THAT HARDWIRED POOL ALARMS BE INSTALLED ON ALL WINDOWS AND DOOR TO INCLUDE ALL OPENINGS THAT ARE PART OF THE REQUIRED BARRIER PER FBC SECTION 424.2 NOTE: THE SQUARE FOOTAGES ARE SUBJECT TO CHANGE BASED ON THE ENGINEERED DRAWINGS NOTE: ALL DIMENSIONS ARE APPROXIMATE AND ARE PLUS OR MINUS. FIELD MEASUREMENTS WILL SUPERSEDE DIMENSIONS NOTED ON CUSTOMER SIGNED PLANS. ALARM NOTE: ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85dB A AT 10 FEET ALARM SHALL SOUND CONTINUOUSLY FOR A MINIMUM OF 30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE OF EMITTING A SOUND OF SUFFICIENT VOLUME TO BE HEARD TO THE DWELLING. THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE ALARM FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR. SAFETY BARRIER REQUIREMENT: THE CLIENT HAS THE OPTION OF SELECT ONE THE FOLLOWING SAFETY BARRIER; 1- BABY FENCE. 2- ALARM SYSTEM. THE ALL SAFETY BARRIER SHALL CONFORM TO THE BARRIER REQUIREMENTS OF FLORIDA BUILDING CODE 2007 EDITION "RESIDENTIAL ", CHAPTER 41, SECTION R4101.17 AND FLORIDA BUILDING CODE 2007 EDITION "BUILDING ", CHAPTER 4, SECTION. SOIL STATEMENT PLEASE BE ADVISED THAT THE UNDERSIGNED HAS PERFORMED A VISUAL INSPECTION OF THE SOILS UNDERNEATH THE PROPOSED FOUNDATIONS AND SAID FOUNDATIONS WILL BEAR IN CORAL ROCK. BASED ON OUR OBSERVATIONS, IT IS OUR OPINION THAT THE EXISTING SOILS WILL SAFELY SUPPORT THE ASSUMED SOIL BEARING CAPACITY OF 2000 PSF. CIO „U„n n � POOL LAYOUT PLAN SCALE: 1/4 " =1' -0" FLOTATION ANALYSIS I POOL SIZE UNITS TOP OF POOL WALL ELEVATION (NGVD) _ 10.96 mm FT DIST. FROM TOP OF WALL TO WATER LEVEL 4 IN OF POOL•AT_DEEP END 5.50 FT _DEPTH DEPTH OF POOL ATSHALLOW END _ 3.00 _FT AVERAGE POOL WATER DEPTH 4.25 FT LOWER POOL POINT LEVEL (NGVD) � TURNOVER RATE FT _5.13 9.00 FT FLOOD CRITERIALEVEL (NGVD) INITIAL WATER HEAD 3.8_7 FT LESS HY_DROVERTI_CAL LIEF RE FBC 1618.2.4 -2.00 ...___,FT WW_ AJU STED WATER HEAD � � 1.8_7 FT UP LIFTPRESSUREmm ...___ .... _ 117 PSF SLAB THICKNESS CALCULATION Z�v POOL/ SPAAREA._..._......__ wM__..._ ...____._.__......_......__.._ ._ 302.00. __. FT_...... WALL PERIMETER 78.0_0 FT� AVERAGE WALL HEIGHT ......_.___.�w.._._.�..,�.�.�.� 4.25 FT WATER 62.40 PCF CONCRETE WEIGHT _6.00— 150.00 PC_F IN THKNESS _. _.. _.__..._. SLAB IC 1 -. SALT SYSTEM. WALLTHICKNESS 7.00 IN SLAB UPLIFT RESISTING PRESSURE 75.00 PSF WALL UPLIFT RESISTING ham. �7• � PSF _PRESSURE _ TOTAL UPLIFT RESISTING PRESSURE _87.50 _162.50 PSF CH EKING UPLIFT FORCE 0.72 < 1 OK a 0 fop° FREESTANDING G.F.C.I. OUTLET SHALL BE LOCATED NOT CLOSER THAN 10 FT NOR MORE THAN 20 FT FROM WATER'S EDGE. �r �r ot.;tj 1 H MIA,14) BUILDING DEPT. STRUC T URA ECTION POOL SPECIFICATION POOL SIZE 12'x24' FTxFT DEEP END T -6" FT SHALLOW END 3' -0" FT POOL AREA 302 SQFT POOL PERIMETER 78 FT POOL CAPACITY 9,601 GALLONS TURNOVER RATE 1.79 HR INTERIOR FINISH DIAMOND BRITE WATER LINE TILE 6 IN COPING 8 IN PUMP SIZE 1 HP FILTER SYSTEM & SIZE 150 SQFT Z�v INLETS 3 INLETS / 1 FLOOR BUBBLER MAIN DRAIN 2 SKIMMER 1 r0��,v� v LED LIGHT POOL (COLOR) 54W 12V PATIO FINISH & SIZE 750 SQFT PAVERS TILE DECK DRAINS NONE A OTHER ITEMS: 1 -. SALT SYSTEM. M M M r� v U- r- W ° z CD 0 to co M Z�v L� w r0��,v� v r C) N ~ M „ x co A 0 z v �1 ►�I U L � � ham. �7• � 0 Y U w 2 U W O U w zU O ri �m W o N N r 0 z Q Q � Z Q f-- j / 0. Z) �WO z O ♦^ U VJ v♦ O z 0 �1 � M co w L; GC 0 �1 J 00 A W Z 0 St °V M c0 O O w Two v1 a DATE: FEB.-212,2012 DRAWN: L.A.H. REVISED A.H. Sheet SP -1