Loading...
12-300-001w • U Z • w 0 LOT 10 0 M c7 O T_ ELECTRICAL METER w U Z w U- Y z J z 2 U ........... _ CANAL ............. _. S.W 63 rd COURT T-7 50' R/W — - SITE PLAN SCALE: 1/16 " =1' -0" LEGAL DESCRIPTIONS LOT 6, BLOCK 44 OF " SOUTH MIAMI HEIGHTS ADDITION V ", ACCORDING TO THE PLAT THEREOF AS RECORDED IN PLAT BOOK 86, PAGE 56 OF PUBLIC RECORD OF MIAMI -DADE COUNTY, FLORIDA. �__7_ FA GENERAL POOL NOTES. 1- ALL FLOORS AND WALLS OF POOL TO BE GUNITE APPLIED CONCRETE A 28 DAY MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI. 2- ALL REINFORCING STEEL TO CONFORM TO ASTM 615 GRADE 60. 3- ALL POOL PIPING TO BE SCHEDULE 40 PVC BEARING NSF APPROVAL EXCEPT MAIN DRAIN TO BE SCHEDULE 80 PVC. 4- FILTER BACKWASH SHALL COMPLY WITH CHAPTER 50 OF THE SFBC. 5- NO POOL OR SPA DECK SHALL BEAR ON ANY TYPE OF SOILS EXCEPT CLEAN SANDS OR ROCK WHICH SHALL BE COMPACTED TO PROVIDE A SAFE BEARING CAPACITY OF 2000 PSF. ANY ORGANICS, MARLS, OR OTHER TYPES OF DELETERIOUS MATERIALS ENCOUNTERED ON EXCAVATION SHALL BE REMOVED (DEMUCKED) IN THEIR ENTIRETY APID THE AREA SHALL BE BACKFILLED WITH ACCEPTABLE SOIL AND COMPACTED IN 12" THICK LAYERS. WHERE THE CONTRACTOR CAN NOT REMOVE THE ORGANICS DUE TO WHATEVER CAUSED, THE POOL SHALL BE REDESIGN FOR PILING. 6- IN ALL CASES THE POOL CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO PROTECT EXISTING STRUCTURES FROM FAILURE BY SHORING, UNDERPINNING OR ANY OTHER METHOD IF REQUIRED. THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURE. 7- THE DESIGN ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACK AREAS. PLOT PLANS NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE ARE SO INDICATED. POOL CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES IF NECESSARY. CONTRACTOR AND / OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. 8- CONTRACTOR SHALL ESTABLISH LOCATIONS OF UTILITIES AT THE SITE. MINIMUM CLEARANCE DIMENSIONS SHALL BE HELD AND SHALL BE AS REQUIRED BY THE LOCAL REGULATORY AGENCY IN GENERAL. HOLD A DISTANCE OF 15 FEET FROM OVERHEAD ELECTRIC LINES TO OPEN POOL WATER AND 10 FEET FROM UNDERGROUND ELECTRIC LINES. 9- POOL SLIDES TO BE INSTALLED IN ACCORDANCE WITH LATEST EDITION OF CONSUMER PRODUCTS SAFETY COMMISSION, W.D.C. 10- MINIMUM 4' -0" HIGH IS FENCE RECOMMENDED AROUND ALL POOLS IN UNSCREENED AREAS. 11- WHERE POOLS ABUT OR ARE PLACED NEARBY SEAWALLS OR BULKHEADS SPECIAL CARE SHALL BE EMPLOYED. THE WALLS SHALL BE IN GOOD CONDITIONS NOT PERMITTING ANY SHIFTING OR REMOVAL OR LOOSENING OF THE SUPPORTING SOIL AWAY FROM THE POOL. IF THE WALLS DO NOT FULLY CONTAIN THE SOILS BEHIND THEM, THEY SHALL BE REPLACED OR REPAIRED. CONTINUAL MAINTENANCE OF THE WALLS IS REQUIRED OF THE PROPERTY OWNER. WHEN EXCAVATING FOR THE POOL, THE SEAWALL TIEBACKS SHALL NOT BE CUT. WHERE CONCRETE DEADMEN FALL WITHIN THE EXCAVATION, NOTIFY THE ENGINEER FOR INSTRUCTIONS. 12- THE CONTRACTOR SHALL BACKFILL THE POOL SHELL WITH CAUTION. THE PLUMBING SHALL NOT BE DISTURBED. BACKFILL SHALL BE ACCOMPLISHED WITH CLEAN SANDS FREE OF ORGANIC MATERIALS AND SHALL BE PLACED IN 12" THICK LAYERS. EACH LAYER SHALL BE COMPACTED TO 90 % OF THE SOILS MAXIMUM DENSITY BY TAMPING SOLIDLY. SOILS BELOW THE PATIO SHALL BE PLACED IN A SIMILAR MANNER. 13- WHERE PATIOS ARE INDICATED BY OTHERS. THE PATIO DESIGN NOTES SHOWN ON THE TYPICAL WALL SECTION DO NOT APPLY. PATIO DESIGN SHALL BE BY OTHERS. 14- WARNING: TO EMPTY POOL AFTER CONSTRUCTION FOR REPAIRS OR ANY OTHER REASON, THE HYDROSTATIC UPLIFT PRESSURES BENEATH THE POOL MUST BE ELIMINATED TO PREVENT THE POOL FROM FLOATING UPWARD. THE OWNER MUST CONSULT AND POOL REPAIR CONTRACTOR EXPERIENCED IN ELIMINATING UPLIFT PRESSURES. 15- THIS PLANS REMAINS THE PROPERTY OF THE DESIGN ENGINEER. IT IS NOT TRANSFERABLE FROM ONE CONTRACTOR TO ANOTHER WITHOUT THE WRITTEN PERMISSION OF THE DESIGN ENGINEER AND TO THE BEST OF OUR PROFESSIONAL KNOWLEDGE AND BELIEF, THEY HAVE BEEN PREPARED IN COMPLIANCE WITH THE SFBC AND ALL APPLICABLE LOCAL CODES AND REGULATIONS. 16- TEMPERATURE OF SPA WATER SHALL BE SET SO THE MAXIMUM WATER TEMPERATURE 102 F. o p °p0 00 0 �O 4 p00 00 p °off Oo D pro 0> 00 0 0 po 00 o> o °op00� o op °0 O Oo �� o0 0 0� ° o o° ° 0 pp° 000Q 0 AREA CALCULATION: AREA % OF TOTAL LOT AREA 9674.00 SF 100% HOUSE 2099.00 SF 21.69% DRIVEWAY 811.00 SF 8.38% MAX. IMPERVIOUS COVERAGE THAT HARDWIRED POOL ALARMS BE INSTALLED ON ALL WINDOWS AND DOOR TO INCLUDE ALL OPENINGS THAT ARE PART OF THE REQUIRED BARRIER PER FBC SECTION 424.2 ALARM NOTE: ALL DOORS AND WINDOWS PROVIDING DIRECT ACCESS FROM THE HOME TO THE POOL MUST BE EQUIPPED WITH AN EXIT ALARM THAT HAS A MINIMUM SOUND PRESSURE RATING OF 85dB A AT 10 FEET ALARM SHALL SOUND CONTINUOUSLY FOR A MINIMUM OF 30 SECONDS AFTER THE DOOR IS OPENED AND BE CAPABLE OF EMITTING A SOUND OF SUFFICIENT VOLUME TO BE HEARD TO THE DWELLING. THE ALARM SHALL BE EQUIPPED WITH A MANUAL MEANS TO TEMPORARILY DEACTIVATE THE ALARM FOR A SINGLE OPENING. THE DEACTIVATION SWITCH SHALL BE LOCATED AT LEAST 54 INCHES ABOVE THE THRESHOLD OF THE DOOR. SAFETY BARRIER REQUIREMENT: THE CLIENT HAS THE OPTION OF SELECT ONE THE FOLLOWING SAFETY BARRIER; 1- BABY FENCE. 2- ALARM SYSTEM. THE ALL SAFETY BARRIER SHALL CONFORM TO THE BARRIER REQUIREMENTS OF FLORIDA BUILDING CODE 2007 EDITION "RESIDENTIAL ", CHAPTER 41, SECTION R4101.17 AND FLORIDA BUILDING CODE 2007 EDITION "BUILDING ", CHAPTER 4, SECTION. SOIL STATEMENT PLEASE BE ADVISED THAT THE UNDERSIGNED HAS PERFORMED A VISUAL INSPECTION OF THE SOILS UNDERNEATH THE PROPOSED FOUNDATIONS AND SAID FOUNDATIONS WILL BEAR IN CORAL ROCK. BASED ON OUR OBSERVATIONS, IT IS OUR OPINION THAT THE EXISTING SOILS WILL SAFELY SUPPORT THE ASSUMED SOIL BEARING CAPACITY OF 2000 PSF. 0O I, Q-,(� n v o POOL LAYOUT PLAN SCALE: 1/4 " =1' -0" FLOTATION ANALYSIS UNITS TOP OF POOL WALL ELEVATION (NGVD) 10.96 FT DIST. FROM_T_O_P OF_WALL TO WATER LEVEL �� µ �4 IN��� 5.50_ DE PTH OF ATDEEP END FT _PO_OL _ DEPTH OF POOL AT SHALLOW END�� 3.00 POOL PERIMETER AVERAGE POOL WATER DEPTH 4.25 _FT FT LOWER POOL POINT LEVEL (NGVD) 5.13 FT 9.00 FT FLOOD CRITERIA LEVEL (NGVD ) INITIAL WATER HEAD WATER LINE TILE FT LESS_HYDROVE_RTICAL RELIEF FBC 1618.2.4 _3.87 -2.00 FT_ 1.87 FT AJUSTED WATER HEAD HP FILTER SYSTEM & SIZE 150 SLAB THICKNESS CALCULATION ! POOL / SPAAREA 302.00 FT WALL PERIMETER 78.00 FT _ AVERAGE WALL HEIGHT 4.25 62.40 FT mWATER � cl x O o CONCRETE WEIGH_ T _ _ 150.00_ _PC_F PCF SLAB THICKNESS 6.00 IN WALL THICKNESS 7.00 .... ... ........... IN SLAB UPLIFTRESISTING PRESSURE 75.00 PSF WALL UPLIFT RESISTING PRESSURE_ 87.50 PSF TOTAL UP_LIF_T RESISTING_ PRESSURE _ 162.50 - CHEKING UPLIFT FORCE _ 0.72 _PSF__ < 1 OK FREESTANDING G.F.C.I. OUTLET SHALL BE LOCATED NOT CLOSER THAN 10 FT NOR MORE THAN 20 FT FROM WATER'S EDGE. CITY OF SOUTH MIAMI BUILDING DEPT. .- "sfRUcTtIRAL SECTION u0ni )VED 6 POOL SPECIFICATION POOL SIZE 12'x24' FTxFT DEEP END 5' -6" FT SHALLOW END 3' -0" FT POOL AREA 302 SQFT POOL PERIMETER 78 FT POOL CAPACITY 9,601 GALLONS TURNOVER RATE 1.79 HR INTERIOR FINISH DIAMOND BRITE WATER LINE TILE 6 IN COPING 8 IN PUMP SIZE 1 HP FILTER SYSTEM & SIZE 150 SQFT O .- o j5 v C5 INLETS 3 INLETS / 1 FLOOR BUBBLER MAIN DRAIN 2 SKIMMER 1 cl x O o LED LIGHT POOL (COLOR) 54W 12V PATIO FINISH & SIZE 750 SQFT PAVERS TILE DECK DRAINS NONE U U) OTHER ITEMS: 1 -. SALT SYSTEM. mI u_ u' c co •E o w o o c C z mo -� - U) ZLL a W O .- o j5 v C5 rol N A cl x O o c/) Z .- C ►�+ U U) w .' 0 Y U w x U O w 5 U Z O p m On w a o N N r 0 z -z J Z EL �WO z O U VJ �/'� z_ o O M W U- 0 U- < O Q a cal Lu ►-1 O Z u L M co Fil U) w O O O w O EL DATE: FEB. 212, 2012 DRAWN: L.A.H. REVISED_ A.H. Sheet SP -1 mI