98-137-001I\ ESPRESSO I \ I � 1 -1 /2" IWL 3CSK I \\ 2 I � „ 01 I \ 21; \ 1" IWL TO ICE MACHINE I \\ RUN ABOVE SLAB AND SANITARY LINES SHALL SLOPE \ TERMINATED AT FLOOR AS FOLLOWS: 1 2 \ DRAIN WITH AIR tj/- LESS THAN 3" : 1 /4" /LF MIN. 2 3 CO 3" AND GREATER: 1 /8 " /LF MIN, r A /G-W\ 3" (7 FU) OW LINE TIED TO 3 EXISTING GW STACK FOR TENANT IN THIS AREA 1/2" WITH 3/8" FLEX CONNECTION CHRONOMITE TANKLESS INSTANT WATER HEATER, 6.2KW 208V 1 P LOCATED BELOW COUNTER ESPRESSO S EXISTING 3" 9 VENT STACK i' I 2„ A S EXISTING 4' 9 SAN STACK SANITARY RISER ' � GW LINE © 1 /8 " /LF 3 FU TIED TO EXISTING SAN STACK FOR THIS AREA 3CSK I \ / �—1 /2„ LANDLORD'S BUILDING y REF 4 STANDARD BACKFLOW ' PREVENTER 1 /2)3 -3/ 4 2 �J i 3/4" � CW M 10 LANDLORD'S NOTES REFER TO LANDLORD /TENANT HANDBOOK AND OPERATIONS MANUAL AND TO SPECIFICATIONS ON THESE PLANS FOR ADDITIONAL REQUIREMENTS. 1, WHERE THE WORD "CONTRACTOR" IS USED, IT REFERS TO THE TENANT'S CONTRACTOR UNLESS OTHERWISE NOTED. 2. CONTRACTOR SHALL COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTION, AND TESTING OF ALL UTILITIES OR INTERFACED SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE 3. CONTRACTOR SHALL FIELD VERIFY SIZE AND /OR LOCATION OF DESIGNATED CHILLS WATER, OUTSIDE AIR, TOILET EXHAUST, BUILDING MANAGEMENT SYSTEM, AND OTHER RELATED LANDLORD /TENANT SYSTEM CONNECTIONS AS REQUIRED. 4. HYDRONIC PIPING SHALL BE COPPER OR BLACK STEEL PER LANDLORD'S BUILDING STANDARD. 5. CONTRACTOR SHALL CONNECT TO EXISTING CHILLED WATER LINE TAPS PROVIDED FOR TENANT SPACE IN THIS AREA. WHERE PREVIOUSLY APPROVED BY LANDLORD'S ENGINEER AND /OR WHERE EXISTING TAPS DO NOT MATCH REQUIRED CHILLED WATER LINE TAPS, CONTRACTOR SHALL PROVIDE FOR CONNECTIONS AS REQUIRED FOR THIS DESIGN. FLUSH AND FILL OF TENANT SYSTEM SHALL BE PERFORMED BY LANDLORD'S DESIGNATED CONTRACTOR. 6. PRESSURE AND TEMPERATURE PORTS SHALL BE INSTALLED TO ALLOW MONITORING OF THE _PRESSURE DIFFERENTIAL AT STRAINERS., COILS, CONTROL VALVES, AND AT LOCATIONS WHERE A CHANGE IN PRESSURE OR TEMPERATURE OCCURS. INSTALLATION OF PERMANENT PRESSURE GAUGES OR THERMOMETERS IS NOT REQUIRED. 7. FLEXIBLE DUCTWORK SHALL BE LIMITED TO A MAXIMUM LENGTH OF 5' PER BRANCH RUNOUT, RIGID DUCTWORK RUN TO THE POINT WHERE FLEXIBLE DUCTWORK BEGINS. ELBOWS SHALL BE INSTALLED TO MAINTAIN A 1,5 HALF - DIAMETER CENTERLINE RADIUS. 8. CONTRACTOR SHALL PROVIDE A STAND -ALONE TEMPERATURE CONTROL SYSTEM UTILIZING LANDLORD'S SPECIFICATION COMPONENTS. SYSTEM SHALL INTERFACE WITH LANDLORD'S BUILDING MANAGEMENT SYSTEM AND PROVIDE TEMPERATURE CONTROL SPECIFICATIONS, INCLUDING SEQUENCE OF OPERATION FOR ALL COMPONENTS. A. ONLY LANDLORD'S SPECIFIED "ANDOVER" TEMPERATURE CONTROLS SHALL BE UTILIZED FOR THIS PROJECT, NO SUBSTITUTIONS ARE PERMISSIBLE. LANDLORD DESIGNATED CONTRACTOR SHALL PERFORM FINAL WIRING CONNECTIONS AND PROGRAMMING OF THE CONTROLS. B. POWER FOR TEMPERATURE CONTROL SHALL BE PROVIDED FROM A DEDICATED CIRCUIT WHERE POWER IS PROVIDED FROM A SOURCE OTHER THAN THE FAN COIL UNIT. CIRCUIT SHALL INCLUDE GROUND WIRE IN ORDER TO MAINTAIN CONTROL MANUFACTURER'S WARRANTY. CIRCUIT BREAKER SHALL BE LOCKABLE TYPE WITH LOCK TO PREVENT UNINTENDED INTERRUPTION OF CONTROL POWER. C. CONTRACTOR SHALL COMPLETE INTERFACE OF SYSTEM IN ACCORDANCE WITH LANDLORD'S BUILDING MANAGEMENT SYSTEM PROCEDURES. CONTRACTOR SHALL COMPLETE INTERFACE AND OPERATIONS SHALL BE SUCCESSFULLY DEMONSTRATED FOR THE LANDLORD' FIELD REPRESENTATIVE PRIOR TO OCCUPANCY. 9. CONTRACTOR SHALL DIRECTLY EMPLOY THE LANDLORD'S DESIGNATED CONTRACTOR TO PERFORM FINAL OUTSIDE AIR, TOILET EXHAUST, AND HYDRONIC SYSTEM TESTING AND BALANCING. 10. CONTRACTOR SHALL ELIMINATE ANY CONFLICTING INFORMATION. DRAINS FROM SECONDARY CONDENSATE PANS SHALL TERMINATE OVER A PLUMBING FIXTURE. 11. PROVIDE LANDLORD'S BUILDING STANDARD DOMESTIC WATER METER WITH A REMOTE READER. COORDINATE READER LOCATION WITH LANDLORD'S FIELD REPRESENTATIVE. 12. CLEANOUTS SHALL BE FULL SIZE, FLOOR OR WALL TYPE, ACCESSIBLE FROM WITHIN THIS TENANT'S SPACE. NO END -OF -PIPE CLEANOUTS ARE ACCEPTABLE. 11 PIPE SLEEVES SHALL EXTEND A MINIMUM OF 4" ABOVE THE FINISHED FLOOR. FIXTURES AND SLEEVES SHALL BE FLASHED INTO THE WATERPROOF MEMBRANE PER MEMBRANE MANUFACTURER'S RECOMMENDATIONS. 14. CONTRACTOR SHALL DIRECTLY EMPLOY THE LANDLORD'S DESIGNATED CONTRACTOR TO PERFORM ALL FIRE PROTECTION SPRINKLER MODIFICATIONS. SYSTEM MODIFICATIONS SHALL BE SCHEDULED IN ADVANCE WITH THE LANDLORD'S FIELD REPRESENTATIVE. THE FIRE PROTECTION SPRINKLER SYSTEM SHALL BE FULLY CHARGED AND OPERATIONAL WHEN THE CONTRACTOR IS OFF THE SITE. .:. ._ _ BUILDING STANDARD METER WITH REMOTE READER. FIELD COORDINATE WITH LANDLORD'S REPRESENTATIVE FOR MANUFACTURER, INSTALLATION OF METER, AND EXACT LOCATION OF READOUT z`. WATER RISER FAI NOTE: ALL DIFFUSERS SHALL BE TITUS MODE TDCA -AA WITH ADJUSTABLE VANES. REFER TO PLAN FOR FURTHER SPECIFICATIONS OUTSIDE AIR CALCULATIONS OUTSIDE AIR REQUIREMENTS PER ASHRAE STANDARD 62 -1989 NEWSLINK SHOP 400 SQUARE FEET X 0.2 CFM/SQUARE FOOT = 80 CFM OUTSIDE AIR PROVIDED = 10C CFI FAN COIL UNIT SCHEDULE UNIT DESIGNATION FCU 1 AREA SERVED NEWSLINK LOCATION CEILING MOUNTING TYPE HORIZONTAL SMOKE DAMPER(S) TOTAL AIR, CFM 1400 FIRE RATED ENCLOSURE VENT AIR, CFM 100 z Q EXTERNAL STATIC PRESSURE, IN. OF H2O 0.7 `1 MOTOR H.P. (AMPS) 1/2(5.4) SMOKE CONTROL FAN SPEED R.P.M. 861 NUMBER OF ROWS 6 TOTAL CAPACITY, BTUH 38,000 ° TOTAL SENSIBLE CAPACITY, BTUH 30,900 z ENTERING AIR TEMP, 'F DB /WB 78.7/64.9 o LEAVING AIR TEMP, °F DB /WB 58.2/56.2 CHILLED WATER TEMP. °F ENT /LEAV 44/56 CHIILED WATER FLOW RATE G.P.M. 6.5 CHIILED WATER PRESS, DROP, FT. OF H20 1.0 , TYPE THROWAWAY Li Li THICKNESS (INCHES) 1 ACCESSORIES (ELECTRICAL HEAT K.W.) 3 CONTROLS ELECTRONIC DESIGN MANUFACTURER TRANE MANUFACTURER'S MODEL NUMBER BCHB -54 ELECTRICAL SERVICE AVAILABLE 208 -1 -60 VAC DESIGN REQUIRES YES N DUCT SMOKE DETECTOR CFM, X FIRE DAMPER(S) 6�X 6 - :3V�..._, i X SMOKE DAMPER(S) I X FIRE RATED ENCLOSURE S X FIRE RATED ROOF /FLOOR CEILING ASSEMBLY _....._. X FIRE STOPPING E X SMOKE CONTROL X RELOCATE VALVED CON THIS TENANT TO AREA SPACE PER LANDLORD' G!� 3 3 -TOI 2" CD VENTE CEILIN EXISTI AR EA. 1" CWS & CWR LINES TIED TO EXISTIN 1" CHILLED WATER LINE STUBOUTS FOI THIS TENANT SPACE. REFER TO MALL PLANS FOR EXACT LOCATION AND POIN OF CONNECTION. 100 CFM 6X6 -2W, ECONDARY DRAIN SLOPING ABOVE FLOOR DRAIN AREA E TO WALL. CUT FLUSH ND TERMINATE POINTING ZL PLUMBING PLAN ...................... .. ........................ ....:.. :i E nt PUBLIC RESTROOMS ­ TENANT SPACE NOTE: BATHROOMS ARE LOCATED 52' AWAY FROM THIS TENANT SPACE. REFER TO SECOND FLOOR SITE PLAN SHADED AREAS BELOW. ....... ............................... — 1 o' N.T.S. LEGEND DESCR PTiON - - - COLD WATER LINE - -- -- - -- HOT WATER LINE - GATE VALVE AIR CHAMBER SANITARY LINE ------ - - - - -- VENT LINE COI CLEAN -OUT HVAC PLAN FIRE PROTECTION PLAN k W. w -gw 13 � .'� Q;,- w c ........... x t�� r� S 4 sti � Jk� NARANJO + ASSOCIATES E C 0 N S U L T I N G E N G I N E E R S E 9300 NW 25TH STREET #209 MIAMI, FL 33172 TEL: (305)599 -9447 FAX: (305)599 -9427 ORLANDO NARANJO, PE #32646 - ELECTRICAL ID# 65- 0479171 50 CFI0 DATE PRE -BID MERCH. PLAN ISSUE N0. CFM, K P 6�X 6 - :3V�..._, i V 6X 6 3 W I D E S I G _....._. 2 T E A M 6X4 6X6 6X4.... .. ........ 400 ..CFM -; 12X 12 -4W 0 14X8.. 400 CF•. 2 1:2X12 -4;48: 0 .; 14X 12 A2 LANDLORD'S BUILDING STANDARD ANDOVER THERMOSTAT WITH TEMPERATURE CONTROL NOTES -� 400 C,FM MODULE. SEE LANDLORD'S 12X 12- 4W......:...'. FU LAY LOUV RED DATE PRE -BID A &E INFORMATION N0. 1 6X 14 A eSB/E�D DUCT TIED TO LANDLORD'S 0/A SYSTEM DOOR OUT IN THIS AREA FOR THIS ;.TENANT. CONNECT TO FCU -1 R/A DUCT WITH MVD. ______________ .....---- _------ .__............ 0 E 111 RAGS FCU -1� _.._..,.., 1" CWS & CWR LINES TIED TO EXISTIN 1" CHILLED WATER LINE STUBOUTS FOI THIS TENANT SPACE. REFER TO MALL PLANS FOR EXACT LOCATION AND POIN OF CONNECTION. 100 CFM 6X6 -2W, ECONDARY DRAIN SLOPING ABOVE FLOOR DRAIN AREA E TO WALL. CUT FLUSH ND TERMINATE POINTING ZL PLUMBING PLAN ...................... .. ........................ ....:.. :i E nt PUBLIC RESTROOMS ­ TENANT SPACE NOTE: BATHROOMS ARE LOCATED 52' AWAY FROM THIS TENANT SPACE. REFER TO SECOND FLOOR SITE PLAN SHADED AREAS BELOW. ....... ............................... — 1 o' N.T.S. LEGEND DESCR PTiON - - - COLD WATER LINE - -- -- - -- HOT WATER LINE - GATE VALVE AIR CHAMBER SANITARY LINE ------ - - - - -- VENT LINE COI CLEAN -OUT HVAC PLAN FIRE PROTECTION PLAN k W. w -gw 13 � .'� Q;,- w c ........... x t�� r� S 4 sti � Jk� NARANJO + ASSOCIATES E C 0 N S U L T I N G E N G I N E E R S E 9300 NW 25TH STREET #209 MIAMI, FL 33172 TEL: (305)599 -9447 FAX: (305)599 -9427 ORLANDO NARANJO, PE #32646 - ELECTRICAL ID# 65- 0479171 1301 East Broward Boulevard Fort Lauderdale, FL 33301 Tel. 954 523 3300 Fax. 954 524 8370 E -mail: rjpcvlikl@col.com DATE PRE -BID MERCH. PLAN ISSUE N0. K P A V L I D E S I G N T E A M 1301 East Broward Boulevard Fort Lauderdale, FL 33301 Tel. 954 523 3300 Fax. 954 524 8370 E -mail: rjpcvlikl@col.com DATE PRE -BID MERCH. PLAN ISSUE N0. DATE PRE -BID A &E INFORMATION N0. L t L . , DATE ARCHITECTURAL REVISIONS NO. , r_ DATE REVISIONS NO. 10/29/98 BUILDING DEPT. 1 12/27/98 LANDLORD'S REVISIONS 2 1/14/99 LANDLORD'S REVISIONS �/4 I 7/27/99 TENANT'S REVISION I PLAN. MF PROD. MF DESIGN SA NOTE WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTORS SHALL VERIFY, AND BE RESPONSIBLE FOR, ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. Sunset Shops Holding Company N EWSLI N K.COM Tenant E -01A The Shops at Sunset Place Miami, FL. tI ,