Loading...
15-239-001t i 3 0 J t CJ U. 13�i B 33 / 00 0000 0000 <36 O - o P.o o. -1 ,-A Design Area No. 1 — O.H. GP II Density .20 Area 1500 F Flow 1428.05gpm 0 42.49 psi Includes 500 gpm Hose allowance SAFETY MARGIN - 25.53P51 7, J071L-2 i lid O �- i', I -- :4 END I' PIPE I M I O In O O EXT 1. Ln O SERVICE AREA - '0. OPEN TO STRUCTURE I { 103 r M L3'- 1O J ! a —0.1 LOUNGE AREA 1 10 t 101 eD �9 • � O 2 10" 7' -2� O �- �• G 15 � —r�144 — — 14 ,�•y — s 1 fil— 13 — - ;` O o z I 1-10 7-M 19 \CUT IT NEW 1� r I "TEE 9._2„ LOUNGE AREA 2 - - OPEN TO STRUCTURE 4 p� 101 - 1 �°�, EXTEND I "PIPE � �.,s � O �\ , 9b 2 M I -1s 4T �• 23) - 3 `! Sip M ARE l _ {� OPEC l 1� �1 ` o' / vEk 31 � 32 !� 3 L0'/ t � ✓ w 4 2x 5TRAP -0-LET x 4 0000 I N. �E � S� ES�OJM R �p5 ' 0 1 / - / 0000, �. 24 1 / / O .- 2 / / 25 t 2x 2 x I 5TRAP -0-LET `_ 37 FIRE PROTECTION I" ? t J' SCALE 1 4' =1' -0" DESIGN NOTES 1) UTILIZE 5.6 K FACTOR, V ORIFICE, 155° DEGREE RATED, QUICK RESPONSE, PENDENT /UPRIGHT SPRINKLERS. SPRINKLER SPACING SHALL BE NO GREATER THAN 130 SQ.FT, PER SPRINKLER. AREA OF SPRINKLER WORK IS ORDINARY HAZARD GROUP II OCCUPANCY. 2) ALL WORK AND MATERIALS TO BE IN ACCORDANCE WITH NFPA 13 2010 AND THE MIAMI —DADE FIRE MARSHAL. SCOPE OF WORK SCOPE OF WORK: MODIFY EXISTING SYSTEM TO PROVIDE PROTECTION TO NEW TENANT ALL MODIFICATIONS TO COMPLY WITH NFPA 13 2010 EDITION 1) PLANS DEPICT INTENT LAYOUT, MINOR FIELD ADJUSTMENTS MAY BE REQUIRED. 2) ALL FIELD ADJUSTMENTS SHALL BE IN ACCORDANCE WITH THE SCOPE OF WORK. 3) ALL PIPING AND HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13 2010 EDITION AND THE MIAMI —DADE FIRE DEPARTMENT. 4) THIS IS AN EXISTING BUILDING PROTECTED BY A WET FIRE SPRINKLER SYSTEM. EQUIPPED WITH A FIRE PUMP 5) ALL MEASUREMENTS ARE CENTER TO CENTER. 6) HEADS DO NOT NEED TO BE CENTER OF TILE. 7) ALL PIPING IS TO BE FABRICATED IN THE FIELD. 8) CONSTRUCTION TYPE IS OF CONCRETE SLAB CONSTRUCTION. 9) ALL NEW 1" PIPE IS TO BE SCH -40 PIPE WITH CAST IRON FITTINGS. 10) ALL ARMOVERS GREATER THAN 12" IN LENGTH SHALL BE SUPPORTED BY A HANGER. 11) IF ALTERED SYSTEM CAN NOT BE ISOLATED FROM OTHER PORTIONS OF BUILDING THEN SECTION 24.2.1.6 OF NFPA 13 2010 EDITION WHICH STATES: "MODIFICATIONS THAT CANNOT BE ISOLATED, SUCH AS RELOCATED DROPS, SHALL NOT REQUIRE TESTING IN EXCESS OF WORKING PRESSURE." SHALL BE IMPLEMENTED. m HILTI 3/8' STUD FOR 1' -4' PIPE 3/8' ROD COUPLING ALL THREAD ROD 3/8' FOR 1--4- PIPE HANGER #04 DETAIL CONCRETE PIN TER RING 1' -4' OE 1' -4' HANGER LOCATION DETAIL PIPE SIZE A B* C 1" S -0" MAX. 12' -0" MAX. 3" MIN. 1'A 4' -0" MAX. 12' -0" MAX. 3" MIN. 1 % - -8" 5' -0" MAX. 15' -0" MAX. 3" MIN. A B* c SPRINKLER HEAD STEEL PIPE LHANGER RING * MAXIMUM HANGER SPACING FOR THREADED STEEL PIPE IS 12' -0" FOR ALL PIPE SIZES FlexHead Sprinkler Drop 1VIDFR ENSURE COUPONS ARE ATTACHED Corrugated stainless steel TO MFCHANI AL TM, hose with stainless steel braid AtU Multi —port Bracket "PEG-TOR jM PER NFPA 13 20*,EDITION•SECTION 1.1,6 MODIFICATIONS THAT•CANNOT BE rSOLAT D, SUCH Self tapiing screws ` I� Adjustable Hub AS RELOCATED DROPS -SHALL NOT REQUIRE TESTJNG %N': XCJ 'SSLOF•SYSTEM'.WORKING.PRESSURE LEGEND Sprinkler Head (by others) Metal or Wooden Stud (or appropriate rigid surface) Flexhead(pbommercial Ceiling Unit FLEXHEAD Model #2024 1NDUSIRiesry�• NEW PIPING — — — EXISTING PIPE / DENOTES PIPE HANGER • EXISTING 1" OUTLET X -X CDUNG HEITH Sprinkler Head (by others) Metal or Wooden Stud (or appropriate rigid surface) Flexhead(pbommercial Ceiling Unit FLEXHEAD Model #2024 1NDUSIRiesry�• SW 58TH. AVENUE M� APPROVED MaA-DAD N" C, U 1 �T`f - IRE DE PARTME NT ELDG. J PCPM FIRE ALARM_ FIRE SUP Rir54aN WW R MAIN EXT. DATE: Z 3 / 4 Y. A)_,,---- ° - PARKING o-- - _- c:, AGE W >p EXISTING PUMP FF` - "``,� �0O - LLJ 4 ?. - � = .�...._�?a� z.y` '```tr- ',^`�� = ci- �, * � �``'•• Z:1 p_ j'"'." _ #g - -. -__ I f - ii i r 1 .+.4f„'t -, �ll'" f f • /'� W LIJ Z N �4 ,� C, n I —3- ltd Fli _ - ,� - TIN - -, -- - �� � i� !���� $ ti i C) :1 C << U AREA OF WORK Q SPACE -C11D A "14 1 -) t KEY PLAN I FOR REFERENCE ONLY I t SCALE: .ON 1 SPRINKLER NOTE 1/4" = 1'-0 CONCEALED - NIA "ALDO—': LOCA<rOFFICE };,,COMME:RC� PARKWAY MIRAMAR,FL33025 I CHECKED -BY: c a }:a+,J„ K, JOB NAM AND40F,ATRON', I 1�.,f,� >�:,,�►�:,, +,tTT.+ �tr�`� 4 ON DEL CIELO CONTRACT WITH: SUNS SHOPS SPACE - C11 C RCC ASSOCIATES 5701 SUNSET DRIVE SOUTH MIAMI, FL CONTRACT NO' SHEET DESCRIPTION: 982842901 FIRE PROTECTION DATE: I REV. #: LATEST REV. DESCRIPTION: DRAWING NO. 2 -16 -15 1 FP -1 OF 1 a. A o� .91 r wrJ�• ' N SYMBOLS IMPORTANT NOTICE TO USER HYDRAULIC DESIGN DATA SPRINKLERS /NOZZLES RESPON SIBILITY APPROVALS SYSTEM INFO DESIGN DES.AREA INSIDE OUTSIDE # OF TOTAL SYSTEM REQUIREMENTS SYM. QTY. ORIENTATION SPK FINISH TEMP. K -FACT NPT SIN MANUFACT. MODEL # RESP ; SYS. #. SYS. TYPE VA. DIA. TTL. SPK. SYS. AREA PIPE � TO BOTTOM OF DECK BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN, THE THE ELECTRONIC DESIGN HAZARD CLASSIFICATION DENSITY AREA LENGTH HOSE HOSE SPRINKLERS AREA# GPWSQ.FT. GPM PSI AT NODE ° , ■ • 6 PENDENT WHITE 155 5.6 /z TY3531 TYCO RF -II QUICK O WORK BY WO DESCRIPTION OF WORK SG ❑ OUT IN [+*123"] 1-4 PIPE TOFlNISHEOFLOOR USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL SQ. FT. FACTOR ALLOW. ALLOW. FLOWING 1500 500 26 1428.0 42.49 TEST 20 UPRIGHT BRASS 155° 5.6 ' /z" TY313 TYCO FRB QUICK ❑ OUT IN ❑F WATER FLOW SWITCH ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE 1 O.H. GROUP II .20 ❑ OUT IN ❑T TAMPER SWITCH INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER ❑ OUT IN S1 O HYDRAULIC REFERENCE POINT PROJECTS OR ADDITIONS TO THE PROJECT FOR WHICH R WAS PREPARED, OR USED FOR #1 BRANCHLINE I MAIN LABEL COMPLETION OF THIS PROJECT BY ANY THIRD PARTY. SIMPLEXGRINNELL DISCLAIMS ALL REVISIONS EADWELDED PIPE LABEL LIABILITY FOR THE USE OR REUSE OF ALTERED FILES BY THE USER OR ANY THIRD PARTY NO. DATE BY REVISION DESCRIPTION -4 CAP (THR'DORGRVD) AND SUCH USE WILL BE A USER'S SOLE RISK. USER SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM 0 2 -13 -15 AVL ISSUE FOR GRC APPROVAL / PERMITp�G(THRDORGRVD) ® SYSTEM RISER ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY -�- FLANGED CONNECTION THEREFROM. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT 2 -WAY EARTHQUAKE BRACE BRACE THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS, AND IN ENCLOSURES WHERE DRY PIPE, DELUGE OR OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS WATER SUPPLY INFO: STATIC PRESSURE 71 PSI - RESIDUAL PRESSURE: 67 Psi WITH 7 GPM FLOWING CID M X .}- 4 WAY EARTHQUAKE (26) TOTAL SPRINKLERS /NOZZLES THIS SHEET -t- PIPE HANGER LOCATED. ARE © 2012 SIMPLEXGRINNELL LP - ALL RIGHTS RESERVED TEST LOCATION: 5701 SUNSET DRIVE BY: MIAMI -DADE FIRE RESCUE TEST DATE: 4-23-14 El rn SW 58TH. AVENUE M� APPROVED MaA-DAD N" C, U 1 �T`f - IRE DE PARTME NT ELDG. J PCPM FIRE ALARM_ FIRE SUP Rir54aN WW R MAIN EXT. DATE: Z 3 / 4 Y. A)_,,---- ° - PARKING o-- - _- c:, AGE W >p EXISTING PUMP FF` - "``,� �0O - LLJ 4 ?. - � = .�...._�?a� z.y` '```tr- ',^`�� = ci- �, * � �``'•• Z:1 p_ j'"'." _ #g - -. -__ I f - ii i r 1 .+.4f„'t -, �ll'" f f • /'� W LIJ Z N �4 ,� C, n I —3- ltd Fli _ - ,� - TIN - -, -- - �� � i� !���� $ ti i C) :1 C << U AREA OF WORK Q SPACE -C11D A "14 1 -) t KEY PLAN I FOR REFERENCE ONLY I t SCALE: .ON 1 SPRINKLER NOTE 1/4" = 1'-0 CONCEALED - NIA "ALDO—': LOCA<rOFFICE };,,COMME:RC� PARKWAY MIRAMAR,FL33025 I CHECKED -BY: c a }:a+,J„ K, JOB NAM AND40F,ATRON', I 1�.,f,� >�:,,�►�:,, +,tTT.+ �tr�`� 4 ON DEL CIELO CONTRACT WITH: SUNS SHOPS SPACE - C11 C RCC ASSOCIATES 5701 SUNSET DRIVE SOUTH MIAMI, FL CONTRACT NO' SHEET DESCRIPTION: 982842901 FIRE PROTECTION DATE: I REV. #: LATEST REV. DESCRIPTION: DRAWING NO. 2 -16 -15 1 FP -1 OF 1 a. A o� .91 r wrJ�• '