Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14-685-002
cn X N 0 co IAL N DOOM TYPE 104 EX /CL2 !-iE IG HWT" III C. 9' -6" ACT DESIGN NOTES ROCl"I TYPE 100 CL1 HEIGHT ISC 816" _ _GYP. US POLO 1/4" = 1' -O 1) UTILIZE 5.6 K FACTOR, I¢' ORIFICE, 155" DEGREE RATED, QUICK RESPONSE, PENDENT SPRINKLERS, SPRINKLER SPACING SHALL BE NO GREATER THAN 130 SQ.FT, PER SPRINKLER. AREA 07 SPRINKLER WORK IS ORDINARY HAZARD GROUP II OCCUPANCY. 2) ALL WORK AND MATERIALS TO BE IN ACCORDANCE WITH NFPA 13 2007 AND THE FIRE MARSHAL. I'9 ? t SCALE Ile-f-0, SCOPE OF WORK SCOPE OF WORK: MODIFY EXISTING SYSTEM TO PROVIDE PROTECTION TO NEW TENANT ALL MODIFICATIONS TO COMPLY WITH NFPA 13 2007 EDITION 1) PLANS DEPICT INTENT LAYOUT, MINOR FIELD ADJUSTMENTS MAY BE REQUIRED. 2) ALL FIELD ADJUSTMENTS SHALL BE IN ACCORDANCE WITH THE SCOPE OF WORK. 3) ALL PIPING AND HANGERS SHALL BE IN ACCORDANCE WITH NFPA 13 2007 EDITION AND THE MIAMI -DADE FIRE DEPARTMENT. 4) THIS IS AN EXISTING BUILDING PROTECTED BY A WET FIRE SPRINKLER SYSTEM. EQUIPPED WITH A FIRE PUMP 5) ALL MEASUREMENTS ARE CENTER TO CENTER. 6) HEADS DO NOT NEED TO BE CENTER OF TILE. 7) ALL PIPING IS TO BE FABRICATED IN THE FIELD. 8) CONSTRUCTION TYPE IS OF CONCRETE SLAB CONSTRUCTION. 9) ALL NEW 1" PIPE IS TO BE XL PIPE WITH CAST IRON FITTINGS. 10) ALL ARMOVERS GREATER THAN 12" IN LENGTH SHALL BE SUPPORTED BY A HANGER. RESPONSIBILITY APPROVALS SYSTEM INFO SYMBOLS IMPORTANT NOTICE TO USER C WORK BY SG DESCRIPTION OF WORK ❑ OUT IN ❑ OUT IN ❑ OUT IN ❑ OUT IN SYS. #. SYS. TYPE VA DIA. TTL. SPK. SYS. AREA '13" PIPE TO BOTTOM OF DECK f N2-4j PIPE �TO FINISHED FLOOR ❑F WATER FLOW SWITCH ❑T TAMPER SWITCH S1 HYDRAULIC REFERENCE POINT #1 BRANCHLINEIMAINLABEL i A4 WELDED PIPE LABEL -p CAP (THRDORGRV'D) ® SYSTEM RISER -O- COUPLING (THIRD OR GRVD) -+- FLANGED CONNECTION -� 2-WAY EARTHQUAKE BRACE + 4-WAY EARTHQUAKE BRACE -f- PIPE HANGER BY ACCEPTING OR USING THIS DRAWING AND /OR THE INFORMATION CONTAINED HEREIN, THE USER AGREES TO THE FOLLOWING TERMS AND CONDITIONS: THE ELECTRONIC INFORMATION IN THE DRAWING MAY BE SUBJECT TO INTENTIONAL OR UNINTENTIONAL ALTERATION. ANY USE, REUSE, COPYING MODIFICATION OR ALTERATION OF THE INFORMATION CONTAINED HEREIN SHALL BE AT THE SOLE RISK OF THE USER. THIS INFORMATION MAY NOT BE SOLD OR TRANSFERRED TO ANY THIRD PARTY, USED ON OTHER PROJECTS OR ADDITIONS TO THE PROJECT FOR WHICH IT WAS PREPARED, OR USED FOR COMPLETION OF THIS PROJECT BY ANY THIRD PARTY. SIMPLEXGRINNELL DISCLAIMS ALL LIABILITY FOR THE USE OR REUSE OF ALTERED FILES BY THE USER OR ANY THIRD PARTY AND SUCH USE WILL BE A USER'S SOLE RISK. USER SHALL, TO THE FULLEST EXTENT PERMITTED BY LAW, DEFEND, INDEMNIFY, AND HOLD SIMPLEXGRINNELL HARMLESS FROM ANY AND ALL CLAIMS FOR LOSS, DAMAGE OR INJURY ARISING DIRECTLY OR INDIRECTLY THEREFROM. IN LOCALITIES SUBJECT TO FREEZING CONDITIONS, THE OWNER MUST MAINTAIN HEAT THROUGHOUT WET PIPE SPRINKLER SYSTEMS AREAS, AND IN ENCLOSURES WHERE DRY PIPE, DELUGE OR OTHER VALVES CONTROLLING WATER SUPPLIES TO SPRINKLER SYSTEMS ARE LOCATED. © 2012 SIMPLEXGRINNELL LP - ALL RIGHTS RESERVED DESIGN AREA# HAZARD CLASSIFICATION 3" MIN. A B* C SPRINKLER HEAD STEEL PIPE LHANGER RING * MAXIMUM HANGER SPACING FOR THREADED UGHTWALL STEEL PIPE IS 12' -0" FOR ALL PIPE SIZES REVISIONS El NO. DATE BY REVISION DESCRIPTION 1 5 -20 -14 AVL ISSUE FOR GRC APPROVAL / PERMIT WATER SUPPLY INFO: STATIC PRESSURE TEST LOCATION: "* 13 �pp� EDITION SECTION ).2.1.6 INSPECTOR SUCK AS PER NFPA 13 SHALL NOT REQUI RE EBBING MODIFICATIONS i#-1AT CANNOT BE ISOLATED AS RELOCATED DROP klVORKING PRESSU IN EXCESS OF SYSTEM LEGEND r1iDFR p'CfA�H�� - - - COVpONs p�L PEES' BNSV �� Mnlol� p HYDRAULIC DESIGN DATA DENSITY DESIGN DES. AREA INSIDE OUTSIDE *OF TOTAL SYSTEM REQUIREMENTS G E S I FT. AREA LENGTH HOSE HOSE SPRINIQERS SO. FT. I FACTOR ALLOW. ALLOW. FLOWING I GPM PSI AT NODE PSI - RESIDUAL PRESSURE: BY: PSI WITH GPM FLOWING TEST DATE: NEW PIPING EXISTING PIPE DENOTES PIPE HANGER EXISTING 1" OUTLET HILTI 3/8" STUD FOR 1"-4" PIPE 3/8" ROD COUPLING ALL THREAD ROD 3/8" FOR 1 " -4" PIPE HANGER *04 DETAI CONCRETE PIN EXISTING SPRINK ✓ eLvc, 1/ / SPRINKLERS / NOZZLES 7 1 PENDENT I WHITE 1 155° 1 5.6 1 TY3531 TYCO RF -II O 1 6 1 PENDENT I WHITE 1 1550 1 5.6 1 TY323 TYCO FRB 13 TOTAL SPRINKLERS / NOZZLES THIS SHEET 0 I— w V) z ;ER RING 1' -4" 'E 1 " -4" FIRE SPRINKLER DETAIL N.T.S. HANGER LOCATION DETAIL PIPE SIZE A B* C 1" 3' -0" MAX. 12' -0" MAX. 3" MIN. 114- 4' -0" MAX. 12' -0" MAX. 3" MIN. 1%--8- 5' -0" MAX. 15' -0" MAX. 3" MIN. A B* C SPRINKLER HEAD STEEL PIPE LHANGER RING * MAXIMUM HANGER SPACING FOR THREADED UGHTWALL STEEL PIPE IS 12' -0" FOR ALL PIPE SIZES 1- 0w w 0 z N r- 3 V) SW 58TH. AVENUE SCHEDULE 1. ]NEW' SPRINKLER PENDENT 2. EXISTING = BRANCH LINE `'1� 3. 1" ARMOVER 4. 1" DROP D 4N S� P STATE: REGISTRATION: FLORIDA 59407 .r•� DISCIPLINE: PHONE: IRE PROTECTION (954)822 -5416 ADDRESS: 950 NE 171st Street Suite 208 North Miami Beach, FL. 33162 � ' SIGNATURE AND SEAL SARAH MAMAN, P.E. f'r' "" KEY PLAN FOR REFERENCE ONLY SCALE: :SPONSE ESCUTCHEON / SPRINKLER NOTE 1/4'1 = 1' -0 QUICK CONCELAED DRAWN BY: QUICK RECESSED ALDO CHECKED BY: —_ CONTRACT WITH: LAKEVIEW CONTRACT NO: -- 977960403 DATE: RE 5 -20 -14 • Nv If- :4*., tyco Situp /exGrinne // LOCAL OFFICE: 10550 COMMERCE PARKWAY MIRAMAR, FL 33025 , JOB NAME AND LOCATION: US POLO ANNS. CLUB STORE" THE SHOPS AT SUNSET PLACE 5780 SUNSET DRIVE SOUTH MIAMI, FL SPACE A - 18 SHEET DESCRIPTION: FIRE PROTECTION LATEST REV. DESCRIPTION: DRAWING NO. "' = FP -1 OF 1 -4