Loading...
14-562-001System Checksums. -= , By SHAMROCK ENGINEERING Sin le Mo� ; y -' ne ; AHU -Z COOLING COIL PEAK CLG SPACE PEAK HEATING COIL PEAK TE ER + t% Mo /Hr: Heating Design ' �& mg Heatin ,*' Beaked at Time: MolHr: i / 15 ! Mo /Hr: Sum of ! g g / ��^ Outside Air: OADB/WI /HR: 91/79/125 GADS: Peaks OADB: 47 SADS �j Z9 �� Ra Plenuf /t ` \ Space Peak Coil Peak Percent Return A� Space Plenum Net Percent Space Percent / lI� Sens. + Lat. Sens. + Lat Total Of Total ! Sensible Of Total Space Sens Tot Sens Of Teal Ret10A 0.0 Btu /h Stu /h Stu /h (•h) ! Stu /h Stu /h (/.) Fn MtrTb itu /h (' /.) Fn BI�ITD 0.1 0.0 Envelope Loads Envelope Loads Skylite Solar 0 0 0 0 ! 0 0 ! Skylite Solar 0 0 0.00 Fn Frict 0.4 0.0 Skylite Cond 0 0 0 0 I 0 0 Skylite Csnd 0 0 0.00 Roof Cond 0 0 0 0 0 0' Roof Cond 0 0 0.00 Glass Solar 0 0 0 0 0 0 1 Glass Solar 0 0 0.00 AIRFLOWS Glass /Door Cond 0 0 0 0 0 0 Glass /Door Cond 0 0 0.00 Cooling Heating Wall Cond 1,226 20.9 1,435 1I 2,798 2 � Wall Cond -1,576 -1,957 11.63 Diffuser 5,885 5,885 Partition /Door 0 0 0 0 0 Partition /Door 0 0 0.00 0 O.DO Terminal 5,885 5,895 Floor 0 0 0I 0 0 Floor 0 Main Fan 5,115 5,115 Adjacent Floor 0 0 0 0'! 0 0! Adjacent Floor 0 0 0 0 0 0 0 Infiltration 0 0 0.00 Sec Fan Infiltration 0 0 0 I Sub Total =_> -1,576 -1,957 11.63 Nom Vent 550 550 Sub Total = => 1,226 20•J 1,435 1 ! 2,782 2 AHU Vent 550 550 Internal Loads Infil 0 0 Internal Leads Lights 19,528 4,292 24,410 15 ; 19,528 16 Lights 0 0 o.00 MinStop /fth 0 0 People 6,000 0 6,000 4' 3,000 3 People 0 0 0.00 Return 5,350 5,350 Misc 92,484 0 92,494 571 92,494 78 Misc 0 0 0.00 Exhaust 15 15 0 0.00 Rm Exh 535 535 Sub Total - > 118,012 4,382 122,994 76 115,012 •97 Sub Total =_> 0 Auxiliary D 0 r. * Ceiling Load 595 -595 0 01 627 1 ' Ceiling Load -33 0 0.00 Leakage Own 0 0 Ventilation Lead 0 0 34,477 21 0 0 Ventilation Load 0 - 14,105 89.37 Leakage Ups 0 0 0 0 A�Ij Air Trans Heat 0 0 0 Ad' Air Trans Heat 0 0 0 Dehumid. Ov Sizing 0 0 Ov /Un�lr Sizing 0 0 0.00 ' Ov /Undr Sizing 0 01 0 0 ! Exhaust Heat 1 0.00 ENGINEERING CKS g -13 -13 0 , OA Preheat Diff. 0 0.00 Exhaust Heat 0 0.00 Cooling Heating Sup. Fan Heat 3,487 2 I RA Preheat Diff. % OA 9.3 9.3 Ret. Fan Heat 0 0 0 A� ditional Reheat 0 0.00 cfm/ft' 2.36 2.36 Duct Heat Pkup 0 0 0 0 0.00 cfmlton 435.14 Underflr Sup Ht Pkup 0 0 ! S tu u/h/h Underfir Sup Ht Pkup Supply Air Leakage 0 0 0 Supply Air Leakage 0 0.00 164.12 Seft' 65.17 -6.41 Grand Total = => 119,833 4,484 162,281 100.00 , 118,437 100.00 Grand Total = => -1,609 - 15,961 100.00 No. People . 12 COOLING COIL SELECTION AREAS HEATING COIL SELECTION IWBIHR Leave DBMS /HR Gross Total Glass CapacltyCoil Airflow Ent Lvg Total Capacity Sens Cap. Coil Airflow Enter DB 'F 'F grAb ft' (' ton MBh MBh cfm 'F 'F gr /Ib /.) MSh cfm 'F 'F Main CIS 13.5 162.3 134.6 5,995 77.2 63.4 65.4 56.4 54.2 59.1 Floor 2,490 Main Htg -16.0 5,885 67.8 70.3 Aux CIS 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Part 0 Aux Htg 0.0 0 0.0 0.0 Opt Vent 0.0 0.0 0.0 0 0.0 0.0 0.0 0.0 0.0 0.0 Int Door 0 Preheat 0.0 0 0.0 0.0 ExFlr 0 Total 13.5 162.3 Roof 0 0 0 Humidif 0.0 0 0.0 0.0 Wall 323 0 0 Opt Vent 0.0 0 0.0 0.0 Ext Door 0 0 0 1 Total -16.0 Project Name: Restaurant Dataset Name: Mello Mushroom Restaurant.trc TRACEm 700 v6.3 calculated at 03:01 FM on 05/1212014 Alternative - 1 System Checksums Report Page 2 of 2