14-482-006OLife Safety Plan 6SCALE: 3A6" =I' -O" W y� a N N Z 0 2 co s 0 2 R a J J w s 0 a b N L .T d a I 10 \\ \ \ , \ \ \\\ "I'll, I'll I \x EXISTING ADJACENT MERCANTILE OCCUPANCY UNOCCUPIED FUTURE TENANT SPACE C11C F.E. U 1 \ lil II - -1= 11 1 NEW ::ENCY LIGHT i EXIT O W/ BAT P 77 777777777777 .• EXISTING ADJACENT � MERCANTILE OCCUPANCY life safetq legend: -' -' - 1 HR = ONE HOUR FIRE RATED SEPARATION f- - TRAVEL DISTANCE F.E. FIRE EXTINGUISHER ON MOUNTING BRACKET 0 3' -0" CLEAR EGRESS ACCESS 1. DURING THE PRE - CONSTRUCTION PHASE OF THIS PROJECT, THE SPRINKLER SYSTEM WILL BE UNIMPAIRED. PERMIT DRAWINGS WILL BE SUBMITTED BY THE LANDLORD'S SPRINKLER CONTRACTOR FOR FULL FIRE SPRINKLER PLAN REVIEW OF THE RENOVATED AREA. FUTURE TENANT WILL MODIFY & SUBMIT DRAWINGS FOR SPECIFIC DESIGN REQUIREMENTS UNDER A SEPARATE PERMIT /PLAN REVIEW. 2. ALL FIRE EXTINGUISHER CABINETS LOCATED ON FIRE RATED WALLS SHALL BE CONSTRUCTED TO MAINTAIN THE INTEGRITY OF THE RATED WALL 3. ALL FIRE EXTINGUISERS TO BE INSTALLED NOT GREATER THAN 75' -0" ALONG THE EGRESS CORRIDOR. 4. FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS AND SMOKE PARTITIONS OR ANY OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS SHALL BE EFFECTIVELY AND PERMANENTLY IDENTIFIED WITH SIGNS OR STENCILING IN A MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION. l^, EXISTING UL LABELED #U419 1 HR 1 PROVIDE TEMPORARY BARRICADE DESIGN PER MALL FIRE RATED TENANT DEMISING WALL STANDARDS. COORDINATE GRAPHICS WITH LANDLORD. WORK TO REMAIN. MAINTAIN FIRE RATING. ALONG EXISTING EXTERIOR COLONNADE TO BE PERFORMED (V.I.F.) DURING NON BUSINESS HOURS WHEN MALL IS NOT OCCUPIED TO PREVENT BLOCKING THE EXISTING COLONNADE AND MEANS NEW UL LABELED #U419 1 HR FIRE OF EGRESS. NO ACCESS PROVIDED FROM EXTERIOR RATED TENANT DEMISING WALL COLONNADE. TEMPORARY ACCESS TO SPACE WILL BE PROVIDED FROM SERVICE CORRIDOR DURING LANDLORD'S WORK. EM FUTURE TENANT SPACE 1 C11D FIRE ALARM & FIRE PROTECTION NOTES 1. ALL FIRE ALARM DEVICES & FIRE SPRINKLER SYSTEM UNDER SEPARATE -NEW UL LABELED #U419 1 HR FIRE PERMIT BY SPECIALTY CONTRACTOR FOR RATED TENANT DEMISING WALL BOTH SPACES C11C & C11D. - -- - - - - - -. z 1 � NEW EMERGENCY LIGHT in W/ BATTERY BACK -UP -. -. -. .- .- .- .- . -. z z NEW EXIT SERVICE CORRIDOR NEW EMERGENCY LIGHT NEW EXI \ LIGHT W/ BATTERY BACK -UP BATTERY CK -1 EXISTING UL LABELED #U419\, 1 HR FIRE RATED ,TENANT \ \ DEMISING WALL TO REMAIN. MAINTAIN FIRE RATING. (V.I.F.) INTERIOR MODIFICATIONS ONLY (ANY EXTE A BOARD APPEARANCE) IY QUIRE 1. F.B.C.) FLORIDA BUILDING CODE 2010 - WITH LATEST SUPPLEMENTS F "B.C.E" FLORIDA BUILDING CODE 2010 EXISTING - WITH LATEST SUPPLEMENTS F.F.P.C. FLORIDA FIRE PREVENTION CODE 2010 - WITH LATEST SUPPLEMENTS N.F.P.A. NFPA LIFE SAFETY CODE - LATEST EDITION F.A.C.) FLORIDA ACCESSIBILITY CODE FOR BLDG. CONSTRUCTION N.F.P.A. -10) STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2. CLASSIFICATION OF WORK / ALTERATION LEVEL ANALYSIS : (F.B.C.E. SECTION 202 & 405.1) GENERAL DEFINITIONS- ALTERATION - ANY CONSTRUCTION OR RENOVATION TO AN EXISTING STRUCTURE OTHER THAN A REPAIR OR ADDITION. ALTERATIONS ARE TO BE CLASSIFIED AS LEVEL 1, LEVEL 2, AND LEVEL 3. ALTERATION LEVEL 2 SCOPE - LEVEL 2 ALTERATIONS INCLUDE THE RECONFIGURATION OF SPACE. THE ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE INSTALLATION OF ANY ADDITIONAL EQUIPMENT. 3. CATEGORY OF REHABILITATION : (F.F.P.0 NFPA 101 SECTION 43.2.2.1.4) RECONSTRUCTION : THE RECONFIGURATION OF A SPACE THAT AFFECTS AN EXIT OR A CORRIDOR SHARED BY MORE THAN ONE OCCUPANT SPACE; OR THE RECONFIGURATION OF A SPACE SUCH THAT THE REHABILITATION WORK AREA IS NOT PERMITTED TO BE OCCUPIED BECAUSE EXISTING MEANS OF EGRESS AND FIRE PROTECTION SYSTEMS, OR THEIR EQUIVALENT, ARE NOT IN PLACE OR CONTINUOUSLY MAINTAINED. 4. OCCUPANCY CLASSIFICATION F.B.C. SECTION 309 & 311) F.F.P.0 NFPA 101 CH. 36 - NEW MERCANTILE OCCUP.) F.F.P.0 NFPA 101 CH. 6 SECTION 6.1.14.1.3 - GROUP M - MERCANTILE INCIDENTAL OCCUPANCY) 5. SUB CLASSIFICATION OF OCCUPANCY (F.F.P.0 NFPA 101 SECTION 36.1.4.2) MERCANTILE - CLASS "A" 6. REQUIRED SEPARATION OF OCCUPANCIES F.B.C. TABLE 508.4) GROUP M - MERCANTILE F.F.P.0 NFPA 101 TABLE 6.1.14.4.1(b) WITH GROUP A (ASSEMBLY) = 1 HOUR WITH SPRINKLER SYSTEM WITH GROUP B BUSINESS) = 1 HOUR WITH SPRINKLER SYSTEM WITH GROUP M (MERCANTILE) = 1 HOUR WITH SPRINKLER SYSTEM WITH GROUP S (STORAGE - LOW & ORDINARY HAZARD) = 1 HOUR (WITH SPRINKLER SYSTEM) 7. REQUIRED FIRE PARTITIONS : WALLS SEPARATING INDIVIDUAL TENANT SPACES (F.B.C. SECTION 709.1.6 & 709.3) GROUP M - MERCANTILE = 1 HOUR (WITH SPRINKLER SYSTEM) 8. IMPORARY SEPARATION WALLS W F.P.C. NFPA 1 CHAPTER 16.4.2) 16.4.2.1: PROTECTION SHALL BE PRROVIDED TO SEPARATE AN OCCUPIED PORTION OF THE STRUCTURE UNDERGOING ALTERATION, CONSTRUCTION, OR DEMOLITION OPERATIONS WHEN SUCH OPERATIONS ARE CONSIDERED AS HAVING A HIGHER LEVEL OF HAZARD THAN THE OCCUPIED PORTION OF THE BUILDING. 9. APPROVED AUTOMATIC SPRINKLER SYSTEM : (F.F.P.0 NFPA 101 SECTION 9.7.1) EXISTING TO BE ADAPTED TO NEW RE- DEMISED SPACES. 10. FIRE ALARM SYSTEM : (F.F.P.C. NFPA 101 SECTION 36.4.4.4) EXISTING TO BE ADAPTED TO NEW RE- DEMISED SPACES 11. OCCUPANT LOAD F.B.C. TABLE 1004.1.1, F.F.P.C. NFPA 101 TABLE 7.3.1.2) GROUP M - MERCANTILE TOTAL NO. OF OCCUPANTS - NEW FUTURE TENANT SPACE C11D 1,380 SF / 30 SF = 46 5' -1" 8' -6" 12. COMMON PATH OF EGRESS TRAVEL ALLOWED F.B.C. SECTION 1014.3.1) F.F.P.0 NFPA 101 SECTION 36.2.5.3) GROUP M = 100 FEET ALLOWED (WITH SPRINKLER SYSTEM) 13. MINIMUM AISLE EGRESS WIDTH ALLOWED F.B.C. SECTION 1017.2) GROUP M = 36" INCHES F.F.P.0 NFPA 101 SECTION 36.2.5.5) (AS DETERMINED BY F.B.C. TABLE 1005.1 BUT NOT LESS THAN 36" INCHES) 14. EGRESS ACCESS TRAVEL DISTANCE ALLOWED : F.B.C. TABLE 1016.1) F.F.P.0 NFPA 101 SECTION 36.2.6) GROUP M (WITH SPRINKLER SYSTEM) = 250 FEET ALLOWED 15. FIRE EXTINGUISHER ANALYSIS : CLASSIFICATION OF HAZARD (N.F.P.A. ,.10 SECTION 1 -5) ORDINARY (MODERATE) HAZARD (N.F.P.A. 10 SECTION 1 -5.2 MINIMUM RATED SINGLE EXTI GUISHER = MAXIMUM FLOOR AREA PER UNIT OF A = 1500 SF MAXIMUM FLOOR AREA FOR EXTINGUISHER = 11,250 SF MAXIMUM TRAVEL DISTANCE TO EXTINGUISHER = 75 FEET 16. FIRE EXTINGUISHER SPECIFICATION MANUFACTURER LARSENS SERIES : MP- SERIES /MULTI PURPOSE DRY CHEMICAL MODEL NO MP5 (UL RATING 2A- 10B:C) CABINET : FULL PANEL CLEAR ACRYLIC, FULLY RECESSED, ALUMINUM DON.�p 7 �,� OT Axtr PEirI'u1517aWiVINT._G?! FIRE PROTECTIONI CONTRACTOR'S,WORKMG PLANS SHALL.BE SUBMITTEI) FOR APPROVAL TO MIAMI! DADE COUNTY FIRE DEPARTMENT BINW ANY SYSTEM IS INSTALLED OR REMODELED. APPROVED BY WWI -GADS, Cuzlt ,1TY FIRE DE I3L17G. PEF; "• �iT__ 141ll I1 3TING PORTIMNS OF SUILC OILS SHALL tCr)li, -3� f �'�NL�I TME, PROMSION9 Oa E.Y STENG 0CCUPAHC;E,S, / SET F16M1YH 114 TH5 FLORMA FIRE PREzlE-11TION CODE. DOr TIVSVILUME ALARM ]P 1, DRAG! -ON working plans shall �3III Z ii t pmnft - pproval to mianu. M&Pr m=�rFim artmen- } Ifrsr B ' g Pe ' nly! INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) r .. ....., LL w U J t4 n^ w 0 w a w Cn III J U 2 zd Al uj a ROBERT K. MORISETTE, AIA, NCARB, LEED AP BD +C, CDP P: FLORIDA REGISTERED ARCHITECT # AR 93259 U z or" revisions 0 w w 2 0 2 z 0 s z U °za 1 04/09/2014 FIRE COMMENTS LIFE SAFETY PLAN & ZONING CODE ANALYSIS #14008 As Shown March 14th, 2014 Permit Set 111 i V M a• (A � Cu � Q) r'I U E ''N 0� > 0 M J U Q (A C: a .E 4-J a f0 N CL ,ccM w •� _ U V M p V) O r*`% 4-J CL N Lti O U) N 0 C Vi zd Al uj a ROBERT K. MORISETTE, AIA, NCARB, LEED AP BD +C, CDP P: FLORIDA REGISTERED ARCHITECT # AR 93259 U z or" revisions 0 w w 2 0 2 z 0 s z U °za 1 04/09/2014 FIRE COMMENTS LIFE SAFETY PLAN & ZONING CODE ANALYSIS #14008 As Shown March 14th, 2014 Permit Set 111 i