Loading...
14-481R-041GENERAL PLUMBING NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE FLORIDA BUILDING CODE, AND ALL APPLICABLE LOCAL ORDINANCES. 2. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST FULLY OPERATIVE E 'WORKMANLIKE MANNER, THE COMPLETE SYSTEM SHALL BE CLA SS WORKM A AFTER COMPLETION OF WORK. 3. PLUMBING CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE OF DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD 0 I OF ONE YEAR FROM AL ACCEPTANCE. FINAL 4. DURING THE BIDDING PROSESS CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS. LOCATION OF EXISTING POINTS OF CONNECTIONS SHALL BE FIELD VERIFIED BEFORE SUBMITTING BID, REQUEST ANY REQUIRED CLARIFICATION AND NOTIFY ARCHITECT AND /OR ENGINEER OF DISCREPANCIES BETWEEN FIELD CONDITIONS AND CONSTRUCTION DOCUMENTS BEFORE COMMENCING WORK. 5. WHERE INDICATED OR REQUIRED, EXISTING SYSTEM COMPONENTS SHALL BE CAREFULLY REMOVED OR RELOCATED. EACH RESULTING OPENING IN THE BUILDING CONSTRUCTION SHALL BE PROPERLY PATCHED AND FINISHED WITH THE SAME MATERIALS AS THOSE ADJACENT TO THE OPENING. LIGHTING ELECTRICAL, DUCTWORK TE NEW PLUMBING WORK WITH , 6. COORDINATE , STRUCTURAL FRAMING AND CEILING SYSTEMS. 7. CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOORS AND ROOFS WITH OTHER TRADES AND REPORT ANY DISCREPANCIES TO ARCHITECT /ENGINEER. NO STRUCTURAL MEMBER SHALL BE CUT OR MODIFIED WITHOUT WRITTEN AUTHORIZATION. 8. DRAWING ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR EXACT LOCATION OF FIXTURES AND PIPING. 9. CONTRACTORS SHALL BE RESPONSIBLE FOR ALL PERMITS, TAXES, INSPECTIONS AND TEST FEES. 10. ALL MATERIALS TO BE PROVIDED UNDER THIS CONTRACT SHALL MEET ALL THE REQUIREMENTS OF THE F.P.C, AND ALL OTHER LOCAL STANDARDS AND REGULATIONS, DEFECTS D 0 AN AMERICAN MANUFACTURER MATERIALS SHALL BE NEW, FREE OF AN F , INDELIBLY MARKED WITH MANUFACTURER NAME, WEIGHT AND /OR CLASS. MANUFACTURER NAMES SHALL BE INTERPRETED AS ESTABLISHMENT OF REQUIRED TYPE, CLASS AND QUALITY. MATERIAL SHALL BE PROVIDED AS FOLLOWS: A. _ ALL WASTE, VENT, AND STORM PIPING BELOW GRADE SHALL BE ONE OF THE FOLLOWING TYPES (AS PER TABLE- 702.2, F.P.C.) A.1 SCHEDULE 40 ABS OR (DWV) PCV PIPING. FOR BUILDINGS EXCEEDING 3- STORIES IN HEIGHT, UNDERGROUND DRAINAGE PIPING SHALL BE SERVICE WEIGHT CAST IRON AS PER SECTION A.1. FOAM CORE PIPING SHALL NOT BE USED. B. ALL WASTE, VENT, AND STORM PIPING ABOVE GRADE SHALL BE ONE OF THE FOLLOWING TYPES (AS PER TABLE - 702.1, F.P.C.) : B.1 SCHEDULE 40 ABS OR (DWV) PCV PIPING. NO COMBUSTIBLE PIPING SHALL BE LOCATED IN RETURN AIR PLENUM. FOAM CORE PIPING SHALL NOT BE USED. C. SANITARY PIPE FITTINGS: C.1 JOINTS FOR HUBLESS PIPE AND FITTING SHALL CONFORM EITH THE F.P.C. AND THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND LOCAL CODE REQUIREMENTS. HUBLESS COUPLINGS SHALL CONFORM TO CISPI 301, JOINTS FOR HUB AND SPIGOT PIPE SHALL BE INSTALLED WITH COMPRESSION GASKETS CONFORMING TO THE REQUIREMENTS OF ASTM STANDARD C -564 OR SHALL BE INSTALLED WITH LEAD AND OAKUM. D. DOMESTIC WATER PIPING AND FITTINGS SHALL CONFORM WITH TABLES 605.4 THRU 605.8. OF THE F.P.C. AND SHALL BE ONE OF THE FOLLOWING TYPES: D.1 COPPER TYPE 'L' ABOVE GROUND AND COPPER TYPE 'K' BELOW GROUND CONFORMING WITH ASME B -88, AND ASTM B -16, LEAD - FREE SOLDER. DOMESTIC WATER PIPING SHALL NO BE INSTALLED BELOW SLAB, UNLESS INDICATED OTHERWISE ON THESE DRAWINGS D.2 PROVIDE WATER HAMMER ARRESTOR 18" HIGH, NEXT LARGE SIZE THAN PIPE SERVING FIXTURE. D.3 INSULATE ALL HOT WATER PIPING WITH 1" RIGID FIBERGLASS OR 1/2" THICK FLEXIBLE FOAM 'INSULATION (ARMAFLEX). FLEXIBLE FOAM INSULATION SHALL NOT BE SPLIT, AND SHALL BE TAPED AT BUTT JOINTS. E. WALL CLEANOUTS. EA JOSAM SERIES 58750 WITH ACCESS COVER OR EQUAL. E.2 PROVIDE CHROME PLATED BRASS ESCUTCHEONS WITH LOCKING SCREWS WHERE PIPE PASS THROUGH FINISHED WALLS. E.3 A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH SOIL AND WASTE STACK. F. ` VALVES. F.1 QUATER TURN BALL VALVES, RATED FOR 125 PSI. MANUFACTURED BY NIBCO, SCOTT, STOCKHAM OR EQUAL. F.2 PROVIDE STOPS AT ALL PLUMBING FIXTURES. EXPOSED STOPS SHALL BE CHROME PLATED. G. PLUMBING FIXTURES. G.1 SEE PLUMBING FIXTURE SCHEDULE FOR FIXTURE SPECIFICATIONS. G.2 PLUMBING FIXTURES SHALL COMPLY WITH WATER CONSERVATION REGULATION FS.553.14. ' G.3 EXPOSED HOT WATER PIPING SERVING PLUMBING FIXTURES SHALL BE PROPERLY INSULATED. 11. PERFORM THE FOLLOWING TEST: A. NEW DOMESTIC WATER PIPING SHALL BE HYDROSTATICALLY TESTED AT 100 PSIG FOR A PERIOD OF NO LESS THAN ONE HOUR. B. WASTE AND VENT PIPING SHALL BE FILLED WITH WATER TO A 10 FOOT HEAD AND ALLOWED TO STAND UNTIL THE WATER LEVEL REMAINS CONSTANT. C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTING. D. STERILIZE ALL NEW DOMESTIC WATER PIPING WITH A MIXTURE OF TWO POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPE FOR A PERIOD OF 24 HOURS. FLUSH THOROUGHLY WITH POTABLE WATER BEFORE PLACING SYSTEM IN SERVICE. 12. WASTE PIPING 2 1/2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM. PIPES LARGER THAN 2 1/2- SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM FALL. 13. INSULATE ALL AIR CONDITIONING AND REFRIGERATION CONDENSATE DRAIN WITH 3/4" INCOAFLEX PIPE INSULATION OR EQUAL. FINISHED, WHERE EXPOSED, WITH 2 COATS OF WHITE LATEX PAINT AS PER MANUFACTURER'S INSTRUCTION. 14. PIPING PENETRATION AT ROOFS, CEILINGS, FLOORS AND WALLS SHALL BE SEALED AIR AND WATER TIGHT. WHERE PENETRATING FIRE RATED CONSTRUCTION, FIRE SAFE TO PROVIDE PROTECTION MATCHING REQUIRED FIRE RESISTANCE RATING. 15. ALL HORIZONTAL VENT PIPING SHALL SLOPE TO DRAW TO STACKS. NO POCKETS OR LOW POINTS SHALL BE CREATED IN THE VENT LINES WHICH MAY PREVENT VENTING IF FILLED WITH CONDENSATION. 16. CEILING ACCESS PANELS SHALL BE PROVIDED FOR VALVES INSTALLED ABOVE OTHERWISE NON- ACCESSIBLE CEILINGS. 17. FURNISH AND INSTALL DIELECTRIC COUPLINGS AT ALL CONNECTIONS BETWEEN DISSIMILAR METALS. 18. THE EXISTING PLUMBING LINES INDICATED OR NOTED ON THESE DRAWINGS, ARE SHOWN AS OBTAINED FROM EXISTING INFORMATION OR SITE OBSERVATIONS, AND ARE ONLY APPROXIMATE IN LOCATION. THE CONTRACTOR SHALL VERIFY THESE LOCATIONS, CONNECTION, POINTS AND SIZES BEFORE PROCEEDING WITH WORK. 19: PRECAUTIONS SHALL BE TAKEN TO PREVENT CONTAMINATION OF OWNER EQUIPMENT, FURNITURE AND CARPETING WITHIN THIS BUILDING. COVER AND WRAP EQUIPMENT, FURNITURE AND CARPETING AS NECESSARY. DUST AND DEBRIS SHALL BE STRICTLY CONTROLLED. CLOSE COORDINATION WITH OWNER WILL BE REQUIRED. OT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE " WHA' WITHIN 6' OF INSTALL, PER PDI THE LAST FIXTURE IF BRANCH IS GREATER PDI i 'STANDARDS AND THAN 20' LONG,PROVIDE ANOTHER "WHA' SIZE MANUFACTURER'S IN MIDDLE, EACH SIZED FOR HALF THE A' INSTRUCTIONS FIXTURE UNITS. WHA SINGLE FIXTURE MULTIPLE FIXTURES PDI SIZE PLUMBING ABBREVIATIONS A/C AIR CONDITIONING HB HOSE BIBB A.F.F. ABOVE FINISH FLOOR HP HORSE POWER A.A.V. AIR ADMITANCE VALVE HYD. HYDRANT SANITARY PIPE E HW HOT WATER B.F.P. O EVENTER BACK FLOW PR HWR HOT WATER RETURN BH BOOSTER I HEATER BALANCING VALVE - - - - - - - BV BALANCING VALVE MIN. MINIMUM BFP BACK FLOW PREVENTER HOSE BIBB -- HOT WATER PIPE 4 .r "' PRES. PRESSURE CLG. CEILING 1 PRV, PRESSURE REDUCING VALVE CO CLEANOUT PSI. POUND SQUARE INCH COND. CONDENSATE PTR PRESSURE AND TEMPERATURE CONT'N. CONTINUATION SUPPLY. ...,._., RELIEF VALVE. CW COLD WATER REG. REGULAR CONN. CONNECTION SHOCK ABSORBER FLOOR DRAIN WITH I SAN. SANITARY DN. DOWN SF SQUARE FEET DWG. DRAWING' SD STORM DRAIN DR. DRAIN • ELEC. ELECTRIC', TDH. TOTAL DYNAMIC HEAD EQUIP. EQUIPMENT TYP. TYPICAL EXP. EXPANSION TM V TEMPERATURE MIXING .VALVE EDP EMERGENCY DRAIN PAN LOW FLOW). EX. EXISTING FLUSHOMETER VALVE. y k FT. FEET UNDRG. UNDERGROUND FD FLOOR DRAIN -TOP OF SEAT ON UWQ- , (HANDICAP UNIT) SHALL BE 11" TO 19" AFF, FIN. FINISH i VTR VENT THRU ROOF FU FIXTURE UNITS � FL. FLOOR GAL. GALLONS �'. GALV. GALVANIZED Kw 1,�*fe, ,rL, " �^": i 1 GRND. GROUND �. - BA1�1'ERY P - WERED�. SENSO OPERATED WATER CLOSET FLUSHOMETER. FOR TOP SPUD BOWLS. GPM GALLONS PER MINUTES 1 GW GREASE WASTE MECHANIC OVER I;DE,xH LE. SOLID BRASS. CHROME PLATED. 1.28 GPF WATER SAVING VALVE. OT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE " WHA' WITHIN 6' OF INSTALL, PER PDI THE LAST FIXTURE IF BRANCH IS GREATER PDI i 'STANDARDS AND THAN 20' LONG,PROVIDE ANOTHER "WHA' SIZE MANUFACTURER'S IN MIDDLE, EACH SIZED FOR HALF THE A' INSTRUCTIONS FIXTURE UNITS. WHA SINGLE FIXTURE MULTIPLE FIXTURES PDI SIZE PLUMBING SYMBOL LEGEND A SYMBOL DESCRIPTION B SYMBOL DESCRIPTION C 1- 33 -60 GATE VALVE 1 -1/4" SANITARY PIPE E 1 -1/2" 114 -154 I - -1N1 -- CHECK VALVE 2 EXISTING PIPE/ DEVICE. BALANCING VALVE - - - - - - - VENT PIPE 11 ® CLEANOUT - - -- COLD WATER PIPE HOSE BIBB -- HOT WATER PIPE 4 .r "' 2 a'r ; SUPPLY x (51 BALL VALVE CD CONDENSATE PIPE 4u .. ' COLD WATER DENOTES EXISTING �I�- -- UNION - - - - - -- PIPING OR FIXTURE _o rL SUPPLY. ...,._., j VENT THRU ROOF k yq�? O .,. EXPANSION TANK r' Q SHOCK ABSORBER FLOOR DRAIN WITH I AIR CHAMBER TRAP PRIMING BRONZE WALL PLATE �Cl) (0 rL, - -� PIPE DOWN WC -H DENOTES NEW C7 • CONNECTING TO 0 DIAMETER EL E (STING 4 2 OT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE " WHA' WITHIN 6' OF INSTALL, PER PDI THE LAST FIXTURE IF BRANCH IS GREATER PDI i 'STANDARDS AND THAN 20' LONG,PROVIDE ANOTHER "WHA' SIZE MANUFACTURER'S IN MIDDLE, EACH SIZED FOR HALF THE A' INSTRUCTIONS FIXTURE UNITS. WHA SINGLE FIXTURE MULTIPLE FIXTURES PDI SIZE PIPE SIZE FIXTURE UNIT LOAD A 1/2" 1 -11 B 3/4" 12 -32 C 1- 33 -60 D 1 -1/4" 61 -113 E 1 -1/2" 114 -154 F 2" 154 -330 FIXTURE UNIT TABULATION MARK FIXTURE COLD HOT VALVE WATER CLOSET 10 -- TANK WATER CLOSET 5 -- URINAL 5 -- LAVATORY /SINK 1.5 1.5 JANITOR'S SINK 3 3 SHOWER /BATHTUB 2 2 PLUMBING FIXTURE SCHEDULE MARK CAP. GAL. SOIL/ ELEMENTS COLD HOT MANUFACTURER MARK FIXTURE WASTE VENT WATER WATER MODEL No. DESCRIPTION r drawn by: WC FLUSH VALVE TYPErG.: ................ ................:.............. cheked by. 1.,�.;f ` MATCH BXISTIN + FIX, S :° -FLOOR OUNTED DOWN OUTLET BLOW -OUT BOLW WITH 1 1 2" TOP SPUD, WHILE VITREOUS f , HOT WATER WATER CLOSET 4 .r "' 2 a'r ; SUPPLY x FIELD VERIFY ± `�'' "r'. � C A .ELONGATED BOWL 2 1 4" PASSAGEWAY 1.28 f WITH LOW WATER CONSUMPTION t / 9P N "ck 4u .. ' COLD WATER z FLUSHO�METE � VAL _o rL SUPPLY. ...,._., f} k yq�? O .,. EXPANSION TANK r' U w U 31HROME PLATED =,TOP OF»SEAT Ill (STANQARD ,,; IT) SHALL BE 14" TO 16" AFF. �p BRONZE WALL PLATE �Cl) (0 rL, - r 7 6 WC -H FLUSH VALVE, HANDICAP C7 • W EXISTING FIXTURE TO REMAIN BOLW WITH 1 1/2" TOP SPUD, WHITE VITREOUS -FLOOR ikuNTED, OWN OUTLET- Bib 1/2 EL TYPE, WATER CLOSET 4 2 _ 00 O CHINA, ELONGATED' BOWL, 2�r1/4" PASSAGEWAY, 1.28 gpf WITH LOW WATER CONSUMPTION w o CgmU _ o cU FLUSHOMETER VALVE. y k C -TOP OF SEAT ON UWQ- , (HANDICAP UNIT) SHALL BE 11" TO 19" AFF, AU t A f .P�AFP W y k "z1 � � 4. � I �;$ }" �'. FLUSHOMETER VALVE o Kw 1,�*fe, ,rL, " �^": i 1 . • e 4S' 3y -;a94 '$x� '•:. n,.."�' s.. .% �.. SLOAN} OPTI. A SI OOTi „hr .,. �. - BA1�1'ERY P - WERED�. SENSO OPERATED WATER CLOSET FLUSHOMETER. FOR TOP SPUD BOWLS. CV 1 MODEL No. 01 -1.28 MECHANIC OVER I;DE,xH LE. SOLID BRASS. CHROME PLATED. 1.28 GPF WATER SAVING VALVE. �o WATER CLOSET SEAT MATCH EXISTING - WHITE, OPEN FRONT ELONGATED SEAT, CHIP RESISTANT POLYPROPYLENE, INTEGRATED HANDLE AND z FIELD VERIFY CHECK HINGE, STAINLESS STEEL MOUNTING BOLTS. w g LAV RECTANGULAR m EXISTING TO REMAIN OR BE LAVATORY 2 2 RELOCATED FAUCET U 1/2 1/2 REFER TO ARCHITECTURAL - SENSOR ACTIVATED WITH DC KIT. F- w DRAWING FOR .SPECIFICATIONS. LAV -H LAVATORY 2 2 EXISTING TO REMAIN (HANDICAP FIXTURE) W FAUCET 1/2 1/2 REFER TO ARCHITECTURAL - SENSOR ACTIVATED WITH DC KIT. - DRAWING FOR SPECIFICATIONS. O 2 Z �/1> U�I�IAL; lINIVERSAL'1vl0UTl NG Ulf UR1N/�L L MATCH EXISTING FIXTURES -WHITE =OUS T.HINA,WASITt�U EXTEt1ED RIAI:OVIOE FIELD VERIFY BRACKET AND HANGERS. " m -ADA COMPLIANCE INSTALLATION WITH RIM NO HIGHER THAN 17" FLUSHOMETER VALVE 3/4" -- SLOAN "OPTIMA SMOOTH „ - BATTERY POWERED, SENSOR OPERATED URINAL CLOSET FLUSHOMETER. FOR TOP SPUD °BOWLS. '. MODEL No. 186 -1.0 MECHANICAL OVERRIDE HANDLE. SOLID BRASS. CHROME PLATED. 1.0 GPF WATER SAVING VALVE. SK -1 SINK 2 2 ELKAY - UNDERMOUNT, POLISHED STAINLESS STEEL. MODEL ECTRU32179R 1/2 1/2 ALLURE - STAINLESS STEEL, SINGLE SWIVEL LEVER WITH SPRAY OPTION. MODEL LK7921 SSS - SK -2 SINK 2 2 ELKAY - UNDERMOUNT, POLISHED STAINLESS STEEL. MODEL ECTRU17179 / 1/2 1/2 ALLURE < - STAINLESS STEEL, SINGLE SWIVEL LEVER WITH SPRAY OPTION. MODEL LK7921 SSS FD FLOOR DRAIN 3 -- -- -- ZURN - PROVIDE WITH STAINLESS STEEL SQUARE GRATE AND TRAP PRIMER CONNECTION. MODEL No. Z1727 NOTES: 1 PLUMBING FIXTURES SHALL COMPLY WITH REQUIREMENTS OF F.P.C. -- CHAPTER 4, SECTION .405.3.1 AND TABLES 604,4, 604,5 AND 709.1. 2 WALL HUNG FIXTURES SHALL BE SUPPORTED AS PER SECTION 2318.15 OR 2510.5.1.1, 2510.5.1.3, FLORIDA BUILDING CODE. 3 COORDINATE FINAL FIXTURE LAYOUT AND SPECIFICATIONS WITH ARCHITECTURAL DRAWINGS BEFORE COMMENCEMENT OF JOB. 4 REFER TO ARCHITECTURAL DRAWINGS FOR COMPLEMENTARY FIXTURE SPECIFICATIONS. PROVIDE ALL ADDITIONAL COMPONENTS, DEVICES AND ACCESSORIES FOR A COMPLETE FIXTURE INSTALLATION. SOIL OR WASTE DO NOT PROVIDE AIR CHAMBERS. PROVIDE WATER HAMMER ARRESTERS WALL BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O -RING CONSTRUCTION, HAVING PDI #WH- 201, ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION. INSTALL IN LINE WITH WATER FLOW TYPICAL CLEANOUT DETAIL DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND /OR PER (THE TABLES SHOWN ABOVE. WATER HAMMER ARRESTERS far8. 1 4 2 3 1 WELDING 0 0 5 2," (MIN) NOTES: 3 EACH SIDE 10 HANGER ROD FASTENED TO STRUCTURE. �2 CLEVIS TYPE(' HANGER. 0 PIPE /INSULATION PROTECTION AT HANGER SUPPORT ® SPRING TYPE VIBRATION ISOLATORS 95% EFFICIENCY WHERE APPLICABLE Q5 PIPE INSULATION. PIPE HANGERS - CLEVIS TYPE. PLT� CONCRETE NOTES: O 1/4" SUPPORT ROD 02 CLEVIS TYPE HANGER. 03 GALVANIZED STEEL ANGLE 2 1/2"x2 1 /2 "x1 1/4" ® 1/4" EXPANTION BOLT PIPE UNION (TYPICAL) ASME RATED RELIEF VALVE AIR GAP FITTING. 3/4" PRESSURE RELIEF EWH -1, ELECTRIC WATER VALVE DRAIN PIPING. HEATER, SEE SCHEDULE a K ON THIS DRAWING. a PROVIDE DEEP GALVANIZED DRAIN STEEL DRAIN PAN WITH 1" _\ NEOPRENE STAND -OFFS. STAND L EDP -- FLOOR NOTES: 1- EXTEND DRAIN PAN AND RELIEF VALVE PIPING TO EXISTING MOP SINK WITH 90' ELBOW DOWN. 2- RELIEF VALVE DICHARGE PIPING SHALL NOT BE TRAPED, SHALL DISCHARGE IN A SAFE PLACE AND SHALL HAVE A AIR GAP FITTING IF IT GOES OUT, AS SHOWN. 3- INSTALL WATER HEATER IN AN UNOBSTRUCTED MANNER PROVIDING ADEQUATE CLEARANCE FOR MAINTENANCE PURPOSE. ELECTRIC WATER HEATER DETAIL. NLT.B. ELECTRIC WATER HEATER SCHEDULE MARK CAP. GAL. HEATING SOURCE ELEMENTS KW. VOLTAGE ^nb L EWH -1 a ELEC. 2 4.5 208v 10 0.93 LOCHINVAR No. LTJ052KDEF r drawn by: a ................ ................:.............. cheked by. IL �'k HOT WATER z �0 �. >; a'r ; SUPPLY x In NyQ N "ck 4u .. ' COLD WATER z _o rL SUPPLY. ...,._., f} CLEAN - OUT TEE O .,. EXPANSION TANK r' U w U 31HROME PLATED BRONZE WALL PLATE �Cl) (0 rL, SOIL OR WASTE DO NOT PROVIDE AIR CHAMBERS. PROVIDE WATER HAMMER ARRESTERS WALL BY SIOUX CHIEF, PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O -RING CONSTRUCTION, HAVING PDI #WH- 201, ASSE # 1010 AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION. INSTALL IN LINE WITH WATER FLOW TYPICAL CLEANOUT DETAIL DIRECTION IF POSSIBLE. SIZE THE UNITS AS SHOWN ON THE DRAWINGS AND /OR PER (THE TABLES SHOWN ABOVE. WATER HAMMER ARRESTERS far8. 1 4 2 3 1 WELDING 0 0 5 2," (MIN) NOTES: 3 EACH SIDE 10 HANGER ROD FASTENED TO STRUCTURE. �2 CLEVIS TYPE(' HANGER. 0 PIPE /INSULATION PROTECTION AT HANGER SUPPORT ® SPRING TYPE VIBRATION ISOLATORS 95% EFFICIENCY WHERE APPLICABLE Q5 PIPE INSULATION. PIPE HANGERS - CLEVIS TYPE. PLT� CONCRETE NOTES: O 1/4" SUPPORT ROD 02 CLEVIS TYPE HANGER. 03 GALVANIZED STEEL ANGLE 2 1/2"x2 1 /2 "x1 1/4" ® 1/4" EXPANTION BOLT PIPE UNION (TYPICAL) ASME RATED RELIEF VALVE AIR GAP FITTING. 3/4" PRESSURE RELIEF EWH -1, ELECTRIC WATER VALVE DRAIN PIPING. HEATER, SEE SCHEDULE a K ON THIS DRAWING. a PROVIDE DEEP GALVANIZED DRAIN STEEL DRAIN PAN WITH 1" _\ NEOPRENE STAND -OFFS. STAND L EDP -- FLOOR NOTES: 1- EXTEND DRAIN PAN AND RELIEF VALVE PIPING TO EXISTING MOP SINK WITH 90' ELBOW DOWN. 2- RELIEF VALVE DICHARGE PIPING SHALL NOT BE TRAPED, SHALL DISCHARGE IN A SAFE PLACE AND SHALL HAVE A AIR GAP FITTING IF IT GOES OUT, AS SHOWN. 3- INSTALL WATER HEATER IN AN UNOBSTRUCTED MANNER PROVIDING ADEQUATE CLEARANCE FOR MAINTENANCE PURPOSE. ELECTRIC WATER HEATER DETAIL. NLT.B. ELECTRIC WATER HEATER SCHEDULE MARK CAP. GAL. HEATING SOURCE ELEMENTS KW. VOLTAGE EFF. MANUFACTUR AND MODEL No. EWH -1 50 ELEC. 2 4.5 208v 10 0.93 LOCHINVAR No. LTJ052KDEF "k 1rI t \ \f GM CONSULTING ENGINEERS 5001 SW 74th COURT SUITE #204 MIAMI, FLORIDA 33155 PHONE: (305) 663 -2944 FAX: (305) 663 -2970 E -MAIL: offic`i­ce.l 1� U z z w �E z Q w z w w I Z " 0 ° N 0 o � v `R s . W � 00 0 &'Aprila( 2014 ., r drawn by: a ................ ................:.............. cheked by. IL �'k z �0 �. >; x In NyQ N "ck 4u .. ' o z _o rL qp f} O IL U w U -' o U +f �Cl) (0 rL, - r 7 6 C7 • W m 'n EL l O _ 00 O w o CgmU _ o cU L V) k C Q � I .• o CV �o z w g m 0 U „ F- w of W a w o J O Z ILL. o 0 G V) m ,\\°: U z z w �E z Q w z w w 4 .,,;h CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: } M1 `R s . ........ ....................... &'Aprila( 2014 ., r drawn by: a es' ................ ................:.............. cheked by. .... 9M, x N "ck P-3 o � _o rL qp f} O SHEET NO, U ¢{„ ? �Cl) (0 7 6 'n EL O w o _ o L V) k 4 .,,;h CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: as shown release date: . ........ ....................... &'Aprila( 2014 r drawn by: es' ................ ................:.............. cheked by. .... 9M, P-3 t SHEET NO, 4 s�