Loading...
14-481R-038MINIMUM 22 0ANIZED STEEL ROUND DUCT. ( 36 0 MAX) U METAL CONTAINER FLASHING 1" WIDE, MINIMUM 22 GAUGE . GALVANIZED STEEL BAND. Q TWO —PLY FLASHING 3 SLOPE 1" 3 © FIBER CANT STRIP NOTE: 7Q BUILT —UP ROOF 12' MAXIMUM SPACING BETWEEN SUPPORTS 4 4 ® ROOF SLAB SEAL WATER TIGHT ROUND DUCT SUPPORT DETAIL 5 Z REMOVEABLE CAP NTS 6 O1 VENT AS PER ANSI 89.1 WHEN ABOVE (TYPICAL OF THREE) ROOF —� �- 1/2"0 GALVANIZED BOLTS WITH NOTES: DECK NUTS AND WASHERS THRU WALL ROOF DECK. TYPICAL OF 4 PER 1. FOLLOW MANUFACTURER LEG. RECOMMENDATIONS FOR 1/2 " 0 UNIT DRAINAGE HOSE MINIMUM. SEE PLUMBING DRAWINGS FOR NOTE: NEW CONDENSING UNIT. FOR STAND HEIGHT REFER TO TABLE BELOW. MAIN DUCT EXHAUST OR RETURN AIR FLOW SUPPLY AIRS 2 "MIN "A" (INLET) 15° MAX FLOW TRANSITION 45° �(THISSPLANE ONLY) MAX „B.. BRANCH DUCT NOTE: AREA OF "A" IS EQUAL TO 1.5 TIMES AREA OF „B„ TYPICAL DUCT CONNECTION DETAIL NTS EQUIPMENT STAND HEIGHT REQUIREMENTS FIRE RATED ENCLOSURE HEIGHT OF LEGS UP TO 24” 2 X 4 METAL ANGLE 25" TO 36" 18" Fir- 3 SCREWS 24" 49" TO 60" 30" ® 2 X 12 PRESSURE TREATED WOOD 2" SHEET METAL w FRAME BAND, 16 GAUGE 0 6 9 (D FILL CAVITY WITH (SOUND ATTENUATION (TYPICAL OF 2) MATERIAL ATTACH UNIT TO SUPPORT STAND WITH o © 2 X 6 METAL ANGLE 1/2 "0, GALVANIZED STEEL, TIE DOWN _� BOLTS, AT 24" OC. PROVIDE WASHERS, DOUBLE LOCKING NUTS AND VIBRATION �o ISOLATOR AS REQUIRED AT EVERY TIE (y) C14 DOWN. Z PIPING ROOF PENETRATION DETAIL 1/2"0, GALVANIZED STEEL, BOLTS NTS AND NUTS. (TYPICAL) 4 J 2 1/2"x2 1/2"x1/4" GALVANIZED W J ANGLE. TYPICAL OF 4. Jo Q (TWO PER SIDE) V) MANUFACTURER 3 1/2 „ MOUNTING U °U BRACKETS WITH LOCKING SCREWS. w —r CONTRACTOR TO PROVIDE ADDITIONAL ALUMINUM STUDS / BLOCKING AS REQUIRED CONDENSING UNIT r WALL MOUNTED STAND. NOA 00 o DUCTLESS MINI U #07- 0509.09 SPLIT UNIT — ROOF CL J 1/8 "0 ANCHOR BOLTS( (`') V 1�0 �o r\ w ¢ 1 EMBEDMENT (TYPICAL OF THREE) ROOF —� �- 1/2"0 GALVANIZED BOLTS WITH NOTES: DECK NUTS AND WASHERS THRU WALL ROOF DECK. TYPICAL OF 4 PER 1. FOLLOW MANUFACTURER LEG. RECOMMENDATIONS FOR 1/2 " 0 UNIT DRAINAGE HOSE MINIMUM. SEE PLUMBING DRAWINGS FOR NOTE: NEW CONDENSING UNIT. FOR STAND HEIGHT REFER TO TABLE BELOW. MAIN DUCT EXHAUST OR RETURN AIR FLOW SUPPLY AIRS 2 "MIN "A" (INLET) 15° MAX FLOW TRANSITION 45° �(THISSPLANE ONLY) MAX „B.. BRANCH DUCT NOTE: AREA OF "A" IS EQUAL TO 1.5 TIMES AREA OF „B„ TYPICAL DUCT CONNECTION DETAIL NTS EQUIPMENT STAND HEIGHT REQUIREMENTS WIDTH OF EQUIPMENT (SHORTEST DIMENSIONS) HEIGHT OF LEGS UP TO 24” 14" 25" TO 36" 18" 37`' TO 48" 24" 49" TO 60" 30" 61" AND WIDER 48" INSTALLATION. CONTINUATION AND MANUFACTURER 2. REINFORCE WALL BEHIND UNIT. INSTALLATION MANUAL FOR DETAILS. SIZE, SPACE AND DISTRIBUTION. AS 1— CONTRACTOR TO SIZE UNIT TIE DOWN TO WITHSTAND HURRICANE REQUIRED TO MATCH WEIGHT AND WIND FORCES AS PER F.B.C. ANCHOR BOLTS. 2— CONTRACTOR TO COORDINATE EXACT MOUNTING LOCATIONS WITH STRUCTURAL ENGINEER. 3— ANY PENETRATIONS INTO ROOF SHALL BE SEALED WATERTIGHT. I WALL A/C UNIT MOUNTING DETAIL N.T.S. CONDENSING UNIT MOUNTING DETAIL NTS ✓" } t t�- X" I af'1r drr t 2 r 0k r f � r GM CONSULTING \\\ ENGINEERS 5001 SW 74th COURT SUITE #204 MIAMI, FLORIDA 33i"15- ? PHONE: (305) 663— 44 \\: \ FAX: (305) 663 -2 0 E —MAIL: office ®gm ce.n t Z w z O U L w ❑ N w W 0 3 0 w m 0 z a ❑ Z Q 0 ❑ C� z 0 w w O w a O w w w w w' Q ¢ w O_ z O w U w z_ 3 w ❑ Z w O 0 a z 0 Z z z w z Q z Q N 0 Z 0 ❑ U Q v 0 Z Q O 0 0 N 0 r 0 ❑ z a Z O v Z O U 0 z 0 w 0 0 Z O 0 z 0 U ❑ Z ¢ Z 0 N ❑ Z Q ¢ r L U w U U Q O U r_ ry ry w a ry 0 0 zLu Lu 3 ¢ :D V) w V) ❑ U z Z w :2 Z Q w Z w w J z 0 0 o C, U � � N w � V�� Z co > > _j �. LL r 0 Q C o O D V W o = t-, O F-- (n vi CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHrrECT CONSULTANT scale: as shown _.....: release date: April 17, 2014 drawn by: es ................. .................... ....... ..... .. cheked by. `..rn M -4 SHEET NO. Z N 00 0 o� � w N 0 00 ! \ W o t n 0 _� �o (y) C14 Z LL. Q \W 4 J W J W U Jo Q W O V) se U °U w —r F- r L _ 00 o U N(y) U ry < — CL J CV (`') V 1�0 �o r\ w ¢ d' cV fV L0 O r_ ry ry w a ry 0 0 zLu Lu 3 ¢ :D V) w V) ❑ U z Z w :2 Z Q w Z w w J z 0 0 o C, U � � N w � V�� Z co > > _j �. LL r 0 Q C o O D V W o = t-, O F-- (n vi CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHrrECT CONSULTANT scale: as shown _.....: release date: April 17, 2014 drawn by: es ................. .................... ....... ..... .. cheked by. `..rn M -4 SHEET NO.