Loading...
14-481-037ACOUSTICAL CEILING DETAIL: E cI IPPnDT WIRE JE 5 BELOW) CEILING MAIN (REFER TO FINISH SCHEDULE) k_KU3J KUIVINCK tKCrCK IU 1-111-411,31-1 JL,nCUULC) 1. SEE ARCHITECTURAL DRAWINGS FOR EXTENT OF WORK, DETAILS AND SPECIFICATIONS. 2. THE ACOUSTICAL CEILINGS SHALL BE INSTALLED COMPLETE WITH SUSPENDED EXPOSED 'T GRID AND LAY -IN CEILING TILES. 3. INSTALL SUSPENSION SYSTEMS IN ACCORDANCE WITH MANUFACTURES PRINTED INSTRUCTIONS, AND TO COMPLY WITH ASTI C635, MEDIUM DUTY SYSTEM. 4. COORDINATE INSTALLATION WITH ELECTRICAL AND MECHANICAL WORK. 5. SUSPENSION SYSTEM: PROVIDE HUNG SUSPENSION SYSTEM. GRILLAGE SHALL CONSIST OF MAIN RUNNERS, CROSS RUNNERS AND STABILIZER BARS AS REQUIRED. HANGER WIRES SHALL BE NOT LESS THAN 12 GAUGE GALVANIZED SOFT ANNEALED MILD STEEL WIRE. WIRES SHALL BE WRAPPED AT LEAST (4) COMPLETE TURNS AROUND SUPPORTS. WIRE SPACING TO BE AX OF 48" O.C. ALONG MAIN RUNNERS (PROVIDE 12 GAUGE WIRE SUPPORTS SPLAYED IN FOUR DIRECTIONS FOR DIAGONAL BRACING. MAINTAIN AN ANGLE OF 450 ON STEEPER & 6' MIN. CLEAR TO ALL HORIZONTAL PIPING OR DUCTWORK. ONLY IN SCHEMATIC ZONES, 6. MOLDINGS: PROVIDE MANUFACTURES STANDARD 'L' SHAPED MOLDINGS TOP MATCH 'T' - MINIMUM LENGTH OF 18 ". 7. CONTRACTOR SHALL FIELD CHECK THE PREMISES AND VERIFY ALL CLEARANCES AS REQUIRED FOR ALL LIGHTING FIXTURES BEFORE PROCEEDING WITH ANY INSTALLATION REPORT ANY DISCREPANCIES TO THE ARCHITECT. 8. ALL FIXTURE TRIM (LIGHTING, SPEAKERS, HVAC, GRILLES, ETC.) SHALL BE METAL AND PAINTED TO MATCH ADJACENT FINISH. PLASTIC TRIM IS NOT ACCEPTABLE UNLESS APPROVED BY ARCHITECT. 9. LEVEL CEILING TO WITHIN 1/8" IN 12' -0" IN ANY DIRECTION. LEVEL WITH HANGER WIRE TAUGHT AND PLUMB, WITHOUT KINKING OR BENDING HANGER WIRES. CEILING HEIGHT SHALL MATCH EXISTING U.O.N. 10. PROVIDE 5% ATTIC STOCK OF ACOUSTICAL TILE MATERIAL USED. 11. SUBMIT ONE FULL SAMPLE OF ACOUSTICAL MATERIAL AND ONE OF EACH TYPE SUSPENSION MEMBER, MOLDING AND HANGER FOR REVIEW BY ARCHITECT. CEILING NOTES: 1. THIS PLAN IS FOR LOCATION PURPOSES ONLY, REFER TO ENGINEERING DOCUMENTS FOR ADDITIONAL INFORMATION. 2. WHERE DRYWALL CEILINGS OCCUR CONTRACTOR SHALL PROVIDE BLDG. STANDARD ACCESS PANELS, AS REQ. BY CODE LOCATION APPROVED BY G. ALVAREZ STUDIO, INC. 3. "F' DENOTES EXISTING TO REMAIN. "R" DENOTES RELOCATED. "N" DENOTES NEW. 4. ACCESS PANELS AT GYPSUM WALL BOARD CEILING SHALL BE FIELD LOCATED BY G. ALVAREZ STUDIO, INC. 5. HVAC GRILL SPECIFICATIONS: TITUS 1 -2 -3 WAY REFLECTOR ALUMINUM MODEL PCS -AA #26 WHITE RETURN: TITUS PAR -AA 2x2 LAY IN 6. PROVIDE ACCESS PANELS IF REQUIRED. ACCESS PANELS SHALL BE 14 "X14" SEAMLESS. CONTRACTOR TO PROVIDE SUBMITTAL FOR ARCHITECT'S APPROVAL. 7. MECHANICAL, PLUMBING, AND ELECTRICAL ENGINEERS SHALL REFER TO DETAILS AND SPECIFICATIONS TO ACCOMMODATE VARIATIONS IN CEILING HEIGHTS AND EQUIPMENT INSTALLED THEREIN. 8. U.O.N. THE LOCATION OF LIGHT FIXTURES, SPEAKERS, AND OTHER TILE CEILING MOUNTED DEVICES SHALL BE DETERMINED BY THE CEILING GRID PATTERN. ALL FIXTURES SHALL BE LOCATED IN CENTER OF CEILING TILE. 9. ALL LIGHT SWITCHES, PROJECTION SCREEN CONTROLS, AND THERMOSTATS SHALL BE GANGED TOGETHER WHERE POSSIBLE. VERIFY ALL NEW LOCATIONS WITH OWNERAENANT SPRINKLER HEADS IN GYP. BD. CEILINGS AND SOFFITS SHALL BE FULLY CONCEALED TYPE (RELIABLE AUTOMATIC SPRINKLERS INC. ",) OR APPROVED EQUAL: FINISH WHITE. 10. ALL SWITCH DEVICES AND COVERS SHALL BE DECORA LEVITON WHITE 11. MECHANICAL, ELECTRICAL AND PLUMBING CONTRACTORS SHALL DESIGN THEIR RESPECTIVE SYSTEMS SUCH THAT NO ACCESS PANELS OF ANY TYPE BE REQUIRED IN ROOMS WITH GYP. BD. CEILINGS 12. ALL SUSPENDED GYP. BD CEILINGS SHALL RECEIVE SKIM COAT. PREP FOR FLAT PAINT FINISH WITHOUT ANY APPARENT SEAMS OR IMPERFECTIONS. REFER TO CEILING PLANS FOR CLG. FINISHES. 13. GYP. CLG. TO BE PAINTED P -1. U.O.N. INSTALL FRAMELESS LINEAR AIR DIFFUSERS 14. EXTEND SPRINKLERS & HVAC AS REQUIRED. VERIFY THAT SPRINKLER PLACEMENT COMPLIES WITH ALL APPLICABLE CODE REQUIREMENTS. CIRCUIT & SWITCH ALL LIGHTING AS REQUIRED. 15. ALL WALL MOUNTED FIXTURES SHALL BE MOUNTED SO AS NOT TO PROTRUDE BEYOND 4" FROM THE FACE OF THE WALL AT A HEIGHT OF 6-8" A.F.F. U.O.N. 16. SUBMIT HVAC PLAN INDICATING SUPPLY AND RETURN DUCTWORK, EXHAUST AND VENTILATION DUCTWORK AND LOCATIONS OF GRILLES AND REGISTERS TO DESIGNER FOR APPROVAL PRIOR TO CONSTRUCTION. 17. PROVIDE FIBER -GLASS ACCESS PANEL AT DRYWALL CEILING IF REQUIRED. ACCESS PANEL SHALL BE 14 "X14" SEAMLESS ACCESS PANEL BY THE GLENDON COMPANY. CONTRACTOR TO PROVIDE SUBMITTAL FOR ARCHITECT APPROVAL. 18. ALL CEILING TILES THAT ARE CUT SHALL HAVE THE CUT EDGE PAINTED TO MATCH THE COLOR OF THE CEILING TILE /FRAME AND NO APPARENT SEAMS OR GAPS SHALL BE NOTICEABLE. CUT /PAINTED EDGE SHALL FACE THE EXTERIOR. 19. COORDINATE OCCUPANCY SENSOR LOCATION WITH CEILING LAYOUT & FURNITURE LAYOUT. 20. CONTRACTOR TO PROVIDE APPROPRIATE LIGHTING TRIMS TO ENSURE COMPATIBILITY W/ TECHSTYLE CEILING TILES AND ARMSTRONG CEILING TILES. 21. CONTRACTOR TO PROVIDE SCREWLESS LUTRON COVER PLATES THROUGHOUT. EXIST. SPACE (N1C.) m 0 0 0 0 F+ 11 _6 O II l C 2 ---- 1 :, =�j / ,�� • / u•• EXPOSED CEILING F3 F3 E3 E3 / C 3 4h � to • �.'�'`:e a¢~ � •/ �7.FF // � EXPOSED CEILING ¢e' ..'.... ........' -ft .... -PI b C -1 • .. -- 1 q� Ate. / / i --- t W D- C -1 C-1 i - / F3 F3 F3 j oJ.•� 13 13 El 3 t i WD- s LE 1 ------------ �Affi 111" <7> EXPOSED o w � s I �► ; mm k� �' .. w • r : i rsLlij : �' � 11 v • II • • • �® 6 LEDj 3T B C3 P2 A F` �� •LEON EXPOSED CEIUN� O -0n / PI X18 n P2 0 n SNAR PROV AND CON G-3 EXPOSED CEILING O t / LED LEDI � 7b% � � ' • 1. ' ��a' /, %'" � '`m k \ te•/ \ P •. , EXPOSED CEILING aOP2 870 q C -2t� r, C -2. �. LEDI LED2 C-2 LEDI •LED2 D, P� ' " E C -3 / 1-y , EXPOSED CEILING \ Vol / V 1 . C -1 F1, a �� �FV �F 8' -0" A.,F2 JEDI \y �ED1 7 / C -1 f • III \7 LEDI L �\a \ ,- , �. O-V 4� P` Vol LEDI i \ C -2 F C -2 C -1 C -1 C -2 • 12 Q� . EXPOSED CEILING ® t C -2 C -3 C -2 1 Ft EXPOSED CEILING , - 4 •'� b' F2 O . F2 pV C-3 A 7-0' A.F.F. �. C- EXPOSED CORING / C -1 O C -1 EXIST: STAIR (NI C.) 0 WiN O FA CEILING LEGEND: *SHADED AREA DENOTES NOT IN CONTRACT Al Reflected Ceiling Plan Scale: 1/8"=1'-0" , KEYED NOTES: lO CENTER TILE CEILING IN ROOM OCONTRACTOR TO COORDINATE CUSTOM GRID DESIGN W/ APPROVED SCHEDULED LIGHT FIXTURE SHOP DRAWINGS FOR ARCHITECTS APPROVAL. OEXPOSED CEILING. PAINTED - TBD O4 5" D X 5" H PERIMETER POCKET SINGLE ROLLER SHADE. REFER TO DETAIL # SHEET A -3.2 OREFER TO MECHANICAL DRAWING S FOR DIFFUSER LOCATIONS IN OPEN AREAS O6 RECESSED MOUNTED LED LIGHTS @ DOCK PIER LOCATIONS. O7 TOP RING TO BE PAINTED W/ BENJAMIN MOORE BLUE PAINT ULTRA FLAT w CEILING MOUNT WIRELESS ACCESS POINT Z LIGHT FIXTURE SCHEDULE: VOLTAGE # LAMPS WA�TTSTYPE/ NOTES: XO CEILING TYPE LINEAR O CEILING HEIGHT FROM FINISH FLOOR (2) T5 RECESSED/ 5/8" DRYWALL CEILING OVER 2-1/2" 25GA. METAL STUDS @ 24" O.C. Cl DRYWALL CLG. W/ NO APPARENT SEAMS OR IMPERFECTIONS SUSPENDED FROM ZANEEN L31508 L: 2,280 MM / 90" W: 46 MM / 1 13/16" H: 130 DECK TO AS HIGH AS POSSIBLE INSTALL W/ FRAMELESS LINEAR AIR DIFFUSERS. (2) T5 CABLE /30K/54W LEVEL 5 FINISH. V FLUORESCENT PENDANT MM / 5 1/8", (2 + 2) X (LINEAR FLUOR T5 HO), 54W Z o NEW ACOUSTICAL CEILING - �' w Lu WITH MINI BIPIN BASE, 120V J 0 o w O 0 Lu HUNG CEILING GRID AND TILES. MOUNT AS HIGH AS POSSIBLE z U F3 4" SQUARE DOWN LIGHT HUNTER DOUGLAS CONTRACT - TECHSTYLE E 24" X 24 ", 1" THICK, WHITE TILE, CLASSIC O LF4SQCFH I 32EB I 20-4SQCFH I -LP26T30K 120 26M C2 F4 CLIPPED CONCEALED GRID, NARROW 1/4" REVEAL.PROVIDE PROPER ACCESSORIES AS Z ZANEEN SIGN MASTER SUSPENSION - DIR./ IND. L3106813 - 120 (2) T5 CABLE /30K /56W REFER TO PLAN FOR V) REQUIRED FOR INSTALLATION. SHADOWLINE PERIMETER MOLDING O v 1,200MM / 47 1/4"X300 MM / 11 13/16" - 2X28/54W T5 � z B.O. ACOUSTICAL CEILING Q o 2 MOUNTING HEIGHTS M 0 0 EL.8' -0" U d EXPOSED CEILING TO BE SPRAYED NEW WOOD CEILING - HUNG 6" WOOD B� R' Olt F5 C3 PAINTED W/ BENJAMIN MOORE; CHELSEA WD -1 OVER 2 -1/2" 25GA. METAL STUDS @ 16" O.C, P /IDE 12 PF/LED SURFACE/ GRAY; ULTRA FLAT. HC -168 C_ PROPER ACCESSORIES AS REQUIRED FOR Q; Q (ABOVE CIRCULAR SOFFIT) INSTALLATION. O w w CEILING MOUNT WIRELESS ACCESS POINT Z LIGHT FIXTURE SCHEDULE: VOLTAGE # LAMPS WA�TTSTYPE/ NOTES: N Z N 00 .q 0 oD0v N D 0 w _ Lu - M o N Ln o O N Z ;u.Q z Q Q L J w - Q J O w N 1 U 00 LLI IY U m \\ \` 2 O u N M U (L J F1 2X2 RECESSED FLUORESCENT LINEAR GL22- D -2 -ET5 -120- TBD - TBD -MW -NO 120 (2) T5 RECESSED/ F2 6' X 8' LONG DIRECT - INDIRECT ZANEEN L31508 L: 2,280 MM / 90" W: 46 MM / 1 13/16" H: 130 120 (2) T5 CABLE /30K/54W V V FLUORESCENT PENDANT MM / 5 1/8", (2 + 2) X (LINEAR FLUOR T5 HO), 54W 0 o WITH MINI BIPIN BASE, 120V J 0 o w O 0 Lu F3 4" SQUARE DOWN LIGHT LIGHTFRAME LF4SQCFH I 32EB I 20-4SQCFH I -LP26T30K 120 26M RECESSED /30K/26W F4 2X4 SUSPENDED ZANEEN SIGN MASTER SUSPENSION - DIR./ IND. L3106813 - 120 (2) T5 CABLE /30K /56W REFER TO PLAN FOR V) v 1,200MM / 47 1/4"X300 MM / 11 13/16" - 2X28/54W T5 MOUNTING HEIGHTS M 0 0 LINEAR FLUORESCENT x F5 LINEAR WALL UPLIGHT ACCLAIM DCD.142.D.A.TBD.0 120 12 PF/LED SURFACE/ C_ (ABOVE CIRCULAR SOFFIT) z PI 15" PENDANT DALS 1062- 36- 42C- 12 -GG -SH 120 CF42 PENDANT/ @ 9 " -0" A.F.F. J P2 18" PENDANT ZANEEN SUPER SIGN ROUND SUSPENSION 18 ", 25 ", 37" - DIRECT 120 T5 PENDANT/ @ 9 " -0" A.F.F. 25" PENDANT 36" PENDANT A UNDERCABINET LIGHT CON -TECH UF228 -P 120 T5 SURFACE/ 30K/ 28W LED 1 PIN LIGHT ZANEEN MAYA SATIN GLASS 120 LED SURFACE/1W MAY.01 1.28.US LED 2 RECESSED WALL PIN LIGHT ZANEEN ARRAKIS 30 ARR.002.23.US 120 LED RECESSED/ 2W X EDGELIT RECESSED EXIT LIGHT LITHONIA LRP W 1/2 RMR XX 120/277 EL N UNV LED RECESSED/ 4W N Z N 00 .q 0 oD0v N D 0 w _ Lu - M o N Ln o O N Z ;u.Q z Q Q L J w - Q J O w N 1 U 00 LLI IY U m \\ \` 2 O u N M U (L J U Z Z w :2 Z Q w Z w w Lp',a 0 0 LL Oo ULO � N � m ' � M N N � Z O M � J N •C lL CL ONE r Lu �LOV° co I 'V M U j �.V Q) CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: as shown N m drawn by: LO 10 N Q V V 0 o J 0 o w O 0 Lu v v 0 0 U Z Z w :2 Z Q w Z w w Lp',a 0 0 LL Oo ULO � N � m ' � M N N � Z O M � J N •C lL CL ONE r Lu �LOV° co I 'V M U j �.V Q) CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: as shown release date: Apnl 18, 2014 drawn by: cc cheked by: cv ww CL 0 J 0 o :3 C) o m O 0 Lu U Z Z w :2 Z Q w Z w w Lp',a 0 0 LL Oo ULO � N � m ' � M N N � Z O M � J N •C lL CL ONE r Lu �LOV° co I 'V M U j �.V Q) CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: as shown release date: Apnl 18, 2014 drawn by: cc cheked by: cv SHEET NO. A -3.1