14-481-0290 CONSTRUCTION NOTES (CONT.' REFER TO SHEET A -2.1 FOR CONSTRUCTION NOTES 38. CONTRACTOR SHALL INSTALL THESE ASSEMBLIES IN ACCORDANCE WITH THE MANUFACTURERS SPECIFICATIONS, THE GYPSUM ASSOCIATION STANDARDS. THE CONTRACTOR SHALL PROVIDE FOR A LIVE LOAD OF 5 POUNDS PER SQUARE FOOT AND MAINTAIN A DEFLECTION OF L/240. 39. ALL FINISHES SHALL MEET THE REQUIREMENTS OF NFPA 101 (CURRENT EDITION) SECTION 27 -3.3.1 FOR FLAME SPREAD AND SMOKE GENERATION. 40. CONTRACTOR SHALL PRACTICE ALL PRACTICAL CARE TO PROVIDE DUST AND NOISE CONTROL PROTECTION. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION. 41. FIRE ALARM TESTING AND SMOKE EVACUATION TESTING SHALL BE CONDUCTED AFTER HOURS. CONTRACTOR SHALL COORDINATE WITH OWNER. 42. ALL PLUMBING FIXTURES SHALL COMPLY W/ EPACT 1992 WATER CONSERVATION STANDARDS. 43. ALL SINKS W/ COLD WATER SUPPLY SHALL BE TYPE L COPPER. 44. A MOISTURE /WATER SENSOR SHALL BE PROVIDED AS PER BUILDING 45. ALL WALL CONNECTIONS /TERMINATIONS AT CURTAIN WALL SHALL COMPLY W/ LANDLORD'S ADDITIONAL NOISE ATTENUATION AND FIRE - RATING REQUIREMENTS. 46. 'O.P.H.' DENOTES OPPOSITE HAND ELEVATION. 47. CONTRACTOR SHALL PROVIDE DETAILED SHOP DRAWINGS NOTING ALL MILLWORK FINISHES AND HARDWARE TO BE USED. CONTRACTOR SHALL PROVIDE ALL NECESSARY HARDWARE AND INTERIOR MILLWORK COMPONENTS. CONSTRUCTION ACTIVITIES NOTE: ALL CONSTRUCTION ACTIVITIES, BOTH DEMOLITION AND NEW WORK, WHICH MIGHT CREATE DISTURBING NOISE LEVELS OR OTHERWISE INTERFERE WITH THE DAY TO DAY OPERATIONS OF BUILDING TENANT+/ - OR CAUSE THE CONTRACTOR'S TO ENTER THE TENANT SPACES SHALL BE PERFORMED AFTER NORMAL BUSINESS HOURS OR ON WEEKENDS (COORDINATE WITH PROPERTY MANAGER REPRESENTATIVE). THESE ACTIVITIES SHALL INCLUDE BUT ARE NOT LIMITED TO: • CUTTING OR CORE DRILLING, CUTTING IN CONCRETE FLOORS OR WALLS. • DRILLING CONCRETE SLABS FOR PIPE HANGERS. • DISABLING THE HVAC SYSTEM. • CRANE OPERATIONS • DISRUPTION OF TENANT ACTIVITIES. • FIRE ALARM TESTING • SMOKE EVACUATION INSPECTIONS • X- RAYING FIELD VERIFICATION FIELD VERIFICATION: THESE DRAWINGS INCORPORATE BUILDING INFORMATION COMPILED FROM VARIOUS SOURCES ASSOCIATED WITH THIS PROJECT AND DEEMED AS RELIABLE. CONDITIONS DIRECTLY AFFECTING THE PRODUCT OR ITS INSTALLATION MUST BE FIELD VERIFIED BY THE CONTRACTOR OR A CONTRACTOR APPOINTED REPRESENTATIVE PRIOR BIDDING. SITE INSPECTIONS NOTE: IF SITE INSPECTIONS ARE REQUIRED, DURING CONSTRUCTION, OR CONSTRUCTION QUALITY VERIFICATION AFTER COMPLETION, THE GENERAL CONTRACTOR MUST PRE - SCHEDULE MEETING WITH THIS OFFICE, WITH THE RESPECTIVE SUBCONTRACTORS ATTENDING, AND AN HOURLY FEE WILL BE CHARGED BY THIS OFFICE TO THE GENERAL ICONTRACTOR. NOTE FOR CONTRACTORS: ALL CONTRACTOR BIDDING AND PRICING SHALL BE MADE UPON THE FINAL DRAWING APPROVED BY THE BUILDING DEPARTMENT. KEYED NOTES: O1 GYPSUM BOARD WALL WITH LEVEL 5 FINISH. REFER TO WALL DESIGNATION AND SECTION FOR WALL COMPOSITION INFORMATION.(TYP.) OFULL HEIGHT GLASS PARTITION W/ DRYWALL HEADER TO BOTTOM OF DECK. REFER TO SECTION 4/A -2.2. REFER TO SECTION FOR DRYWALL PLACEMENT. O3 NEW MILLWORK. REFER TO SHEETS IN THE A -6 SERIES FOR MORE INFORMATION. O4 CONTRACTOR MUST PROVIDE A RECESSED WATER LINE AT REFRIGERATOR LOCATION, COFFE & SODA MACHINE. O5 *F.E. - FIRE EXTINGUISHER: CONTRACTOR TO PROVIDE FIRE EXTINGUISHERS AND SEMI - RECESSED FIRE EXTINGUISHER CABINETS AS REQUIRED BY CODE. ONE PER 2500 SQ. FT.. AND NOT MORE THAN 75 FEET APART. LARSERNS FIRE EXTINGUISHER CABINET & FIRE EXTINGUISHER SS2409 -5R ARCHITECTURAL CABINET; MP -5 5LB. FIRE EXTINGUISHER. STAINLESS STEEL FINISH. CONTRACTOR SHALL PROVIDE GYPSUM WALL BOARD FURRING AS TIGHT AS POSSIBLE TO EXISTING CORE, COLUMNS, AND PERIMETER WALLS. NEW FURRING SHALL ALIGN THROUGHOUT. 7O CONTRACTOR SHALL PROTECT EXISTING ELEVATOR DOORS /CONTROLS DURING CONSTRUCTION. DOORS SHALL BE E.P.D. TO MATCH ADJACENT WALL COLOR. 8O EXISTING WATER COOLER TO REMAIN. CONTRACTOR SHALL PROTECT EXISTING COOLER. 9O EXISTING WATER HEATER TO BE REUSED. REFER TO ENGINEERING DRAWINGS FOR DETAILS. 10 EXISTING CORE DOORS TO BE ELECTROSTATICALLY PAINTED TO MATCH ADJACENT WALL COLOR. 11 MODIFY EXISTING RESTROOM FINISHES AS NEEDED FOR NEW STALL PARTITIONS, <9ALIGN NEW PERIMETER OFFICE SEPARATION PARTITIONS ON CENTERLINE OF WINDOW MULLIONS AS > INDICATED ON DETAIL 1 /A -2.4 O13 EXISTING PERIMETER WINDOWS TO REMAIN. CONTRACTOR SHALL PROTECT EXISTING AND PERIMETER SILL DURING THE CONSTRUCTION. 14 EXISTING DEMISING PARTITION TO REMAIN. CONTRACTOR SHALL PROTECT EXISTING AND PERIMETER WALLS DURING THE CONSTRUCTION. 15 NEW 1 HOUR FIRE RATED DEMISING PARTITION. REFER TO SECTION 1 /A -2.3 <8> NEW 4" A.F.F. RAISED DECK FLOORING. REFER TO FINISH PLAN FOR DETAILS. <17 > REFER TO DETAIL 4 SHEET A2.4 FOR PERIMETER FIRE SAFING DETAILS OPEN TO BELOW (N.I.C.) 00ST, SPACE . (NIC.) EXIST, 2140 ROOR BALCONY (N t.C,l OPEN TO BELOW (N.I.C.) 13 13 L,.,�-,-�, .x � h• *SHADED AREA DENOTES NOT IN CONTRACT 2nd Floor Construction Plan Scale: 1/8"= 1'-0" , TYPICAL WALL LEGEND Z 0000 o C14 o= w O ��o — ch LLJ Z N LO �o M N Z >LL ¢ > z (L ¢ Q 4. J w U J o Wo U 00 W M mm1IommImom _ 00 0 ce \ \ U c-4 M U N M V h %a n CN 04 �-o N O 0 0 0 U z H Z w :�i Z Q w Z w w ♦i^ 0 0 00 U � � N N Cl) L-UN! � Z� 0 > J N •c u_ Q En `o 0 fn < N ^= w o 5 L0 N Cd CU CL 0 IU — — — — NEW FIRE -RATED INTERIOR SLAB -TO -SLAB PARTITIONS: 1 HOUR FIRE RATED DEMISING PARTITION TO MATCH UL DESIGN No. U419. PROVIDE LEVEL 5 FINISH U.O.N. (TYP.) (BUILDING IS FULLY SPRINKLED). ,�. • '•��i,.�', TYPICAL INTERIOR PARTITION: 3 5/8" METAL STUDS (25 G) AT 24" ON CENTER !`f : ����•':,• FRAMED TO 6" ABOVE CEILING. 5/8" G.W.B., BOTH SIDES TAPED AND SPACKLED = �� •' '0 �0 READY FOR FINISH. % ' •• ��; z n NEW INTERIOR PARTITIONS: (NON- RATED). 3 5/8" METAL STUDS (25 GA.) AT 24" ON CENTER, SLAB -TO- SLAB WITH SOUND ATTENUATION BLANKET IN WALL CAVITY. w ONE LAYER OF 5/8" DRYWALL ON EACH SIDE, TAPED, SPACKLED ,/. CHRISTI hWA. �/ID>�Cs;lA AND READY FOR FINISH. (BUILDING IS FULLY SPRINKLED). LICENSE 140,,AR96861 4" OF SOUND ATTENUATION BLANKET 48" TO EACH SIDE OF PARTITION ABOVE CEILING. ARCHITECT — — — — NEW LOW- HEIGHT INTERIOR PARTITION: 3 5/8" METAL STUDS (25 G) AT 24" ON CENTER FRAMED TO 36 ". WALL SHALL HAVE STABILIZERS AS REQUIRED FOR PROPER INSTALLATION. NEW INTERIOR GLASS PARTITION: FRAMELESS FULL - HEIGHT 1/2 "CLEAR TEMPERED GLASS PARTITIONS. REFER TO WALL SECTION #4 & #5 IN SHEET A -2.3 & ELEVATIONS ON SHEETS A -6.x O 1. PARTITIONS TO STRUCTURE SHALL HAVE OPENINGS ABOVE THE CEILING AS DETERMINED BY ENGINEER TO ALLOW FOR THE FREE OPERATION OF THE PLENUM AND SMOKE EXHAUST SYSTEM. 2. BUILDING IS FULLY SPRINKLERED 3. CONTRACTOR SHALL USE 20 GAUGE MTL. STUDS AT 16" O.C. AT ALL HUNG MILLWORK LOCATIONS AND WHERE ALL /ANY WALL ATTACHED FIXTURES /EQUIPMENT ARE INSTALLED. ' 4. ALL DRYWALL PARTITIONS TO BE LEVEL 5 FINISH. CEILINGS TO BE LEVEL 5 CONSULTANT FINISH, scale: 5. TRANSFER BOOTS SHALL BE PROVIDED FOR ALL SLAB TO SLAB z PARTITIONS. release date: gprill8.2014 �w EXISTING PARTITION/ WALLS TO REMAIN: cc cheked by: CONTRACTOR SHALL PROTECT AS NEEDED. cv ;E 3 5/8" METAL STUDS (24 GA) AT 24" ON CENTER TO 6" ABOVE OF CEILING WITH ONE w A-2 Z (1) LAYER OF 5/8" GYPSUM WALL BOARD ON EACH SIDE, WITH R -1 1 BATT V INSULATION IN THE WALL CAVITY, TAPED AND SPACKLED TO A PAINT READY FINISH. PROVIDE R -1 1 BATT. INSULATION BLANKET ABOVE CEILING IN THE DESIGNATED SHEET No. ROOMS. w Q w CL a- � o- o O U 0 O z 0 L 0 Q m N Co U z H Z w :�i Z Q w Z w w ♦i^ 0 0 00 U � � N N Cl) L-UN! � Z� 0 > J N •c u_ Q En `o 0 fn < N ^= w o 5 L0 N Cd CU CL 0 IU — — — — NEW FIRE -RATED INTERIOR SLAB -TO -SLAB PARTITIONS: 1 HOUR FIRE RATED DEMISING PARTITION TO MATCH UL DESIGN No. U419. PROVIDE LEVEL 5 FINISH U.O.N. (TYP.) (BUILDING IS FULLY SPRINKLED). ,�. • '•��i,.�', TYPICAL INTERIOR PARTITION: 3 5/8" METAL STUDS (25 G) AT 24" ON CENTER !`f : ����•':,• FRAMED TO 6" ABOVE CEILING. 5/8" G.W.B., BOTH SIDES TAPED AND SPACKLED = �� •' '0 �0 READY FOR FINISH. % ' •• ��; n NEW INTERIOR PARTITIONS: (NON- RATED). 3 5/8" METAL STUDS (25 GA.) AT 24" ON CENTER, SLAB -TO- SLAB WITH SOUND ATTENUATION BLANKET IN WALL CAVITY. ' • /,\ , ; r►��: ', ONE LAYER OF 5/8" DRYWALL ON EACH SIDE, TAPED, SPACKLED ,/. CHRISTI hWA. �/ID>�Cs;lA AND READY FOR FINISH. (BUILDING IS FULLY SPRINKLED). LICENSE 140,,AR96861 4" OF SOUND ATTENUATION BLANKET 48" TO EACH SIDE OF PARTITION ABOVE CEILING. ARCHITECT — — — — NEW LOW- HEIGHT INTERIOR PARTITION: 3 5/8" METAL STUDS (25 G) AT 24" ON CENTER FRAMED TO 36 ". WALL SHALL HAVE STABILIZERS AS REQUIRED FOR PROPER INSTALLATION. NEW INTERIOR GLASS PARTITION: FRAMELESS FULL - HEIGHT 1/2 "CLEAR TEMPERED GLASS PARTITIONS. REFER TO WALL SECTION #4 & #5 IN SHEET A -2.3 & ELEVATIONS ON SHEETS A -6.x PARTITION NOTES: 1. PARTITIONS TO STRUCTURE SHALL HAVE OPENINGS ABOVE THE CEILING AS DETERMINED BY ENGINEER TO ALLOW FOR THE FREE OPERATION OF THE PLENUM AND SMOKE EXHAUST SYSTEM. 2. BUILDING IS FULLY SPRINKLERED 3. CONTRACTOR SHALL USE 20 GAUGE MTL. STUDS AT 16" O.C. AT ALL HUNG MILLWORK LOCATIONS AND WHERE ALL /ANY WALL ATTACHED FIXTURES /EQUIPMENT ARE INSTALLED. ' 4. ALL DRYWALL PARTITIONS TO BE LEVEL 5 FINISH. CEILINGS TO BE LEVEL 5 CONSULTANT FINISH, scale: 5. TRANSFER BOOTS SHALL BE PROVIDED FOR ALL SLAB TO SLAB as shown PARTITIONS. release date: gprill8.2014 drawn by: EXISTING PARTITION/ WALLS TO REMAIN: cc cheked by: CONTRACTOR SHALL PROTECT AS NEEDED. cv NEW INTERIOR PARTITION (SOUND INSULATED): 3 5/8" METAL STUDS (24 GA) AT 24" ON CENTER TO 6" ABOVE OF CEILING WITH ONE w A-2 Z (1) LAYER OF 5/8" GYPSUM WALL BOARD ON EACH SIDE, WITH R -1 1 BATT INSULATION IN THE WALL CAVITY, TAPED AND SPACKLED TO A PAINT READY FINISH. PROVIDE R -1 1 BATT. INSULATION BLANKET ABOVE CEILING IN THE DESIGNATED SHEET No. ROOMS.