Loading...
14-481-0222010 FLORIDA BUILDING CODE - BUILDING Allowed/ Required Provided M V LA Level 2 - Alteration (2010 FBC - Existing) r� drawn by: Reconiguralion of Space - Less than 50% of building area being altered P9 e9 LJ L-1 cc Occupancy Class: Business 'B' Existing Building O 04 Area of Work: +/- 15,289 U.S.F. Area of Work Seventh Floor Total Area = +/- 15,289 U.S.F. 04 C14 Automatic sprinkler systems shall be provided in all work areas in accordance with the Florida Building Code, Building. Design Ref Florida Fire Prevention Code. See Performance Compliance YES Construction Type: Type IIB - Unprotected, Sprinklered 338 (sprinklered) Chapter 39 - Existing Business Occupancies YES Table 601: Fire Resistance Rating for Building Elements (Type II B Unprotected. Structural Frame - N/A 0 hr Non Combustible Bearing Walls Exterior (see table 602) ( "x" distance >= 30 ") - N/A 0 hr Non Combustible Bearing Walls Interior - N/A 0 hr N/A Nonbearing Interior Walls and Partitions 0 hr 0 hr Floor Construction - N/A 0 hr Non Combustible Roof Construction - N/A 0 hr Non Combustible 39.2.5.2 - Maximum dead end corridors <50' <50' Table 803.5 Classification of Finishes: Exits Enclosures and Exit Passageways B B Classification of Finishes: Corridors C C,B,A Classification of Finishes: Rooms and enclosed Spaces C C,B,A OCCUPANT LOAD CALCULATIONS: Business Areas (100 gross) 338 Interior wall and ceiling finishes - (Exits and exit access corridors) Class A or B Class A or B Table 1004.1.1 OCCUPANT LOAD Class A,B,C Class A,B,C See Life Safeiy Building Informalion and Plans for Detailed Informalion Portable Fire Extinguishers (NFPA 101 Table 3 -2.1) <75' apart <75' apart Table 1016.1 Maximum Travel Distance - (Business) sprinklered 300' -0" <300' -0" Minimum Corridor Width (Section 1018.2) 44" > 44" Maximum Dead End Corridor (Sec. 1018.4) - sprinklered 50' -0" < 50' -0" Minimum Number of Exits Required (Table 1021.1) (Load 1 -500 persons) 2 2 Exit Separation (sprinklered)(1015.2.1) (Diagonal of space/31 see Life Safety >3 2010 Florida Fire Prevention Code NFPA 101 (2009 Edition) Required Provided M V LA Occupancy Classificalion: Exisling Business (B) r� drawn by: Reconiguralion of Space - Less than 50% of building area being altered P9 e9 LJ L-1 cc "Provisions of Level 1(Chap 6) shall also apply Hazard Classilcaton (6.2.2.3): Ordinary Hazard O 04 Area of Work: +/- 15,289 U.S.F. Occupant Load Classification (Table 7.3.1.2) 04 C14 Automatic sprinkler systems shall be provided in all work areas in accordance with the Florida Building Code, Building. Design Ref Florida Fire Prevention Code. See Performance Compliance YES TOTAL OCCUPANT LOAD 338 706 - Accessibility Chapter 39 - Existing Business Occupancies YES 39.1.5 - Classificalion of Hazard Contents Ordinary Hazard 39.1.6 - Minimum Construction Requirements None 0 39.2.3.2 - The clear width of any corridor serving >50 persons >44" >44" 39.2.5.2 - Maximum dead end corridors <50' <50' 39.2.5.3.1 - Maximum common path (sprinklered) <100' <100' 39.2.6.3 - Maximum travel distance (sprinklered) <300' <300' 39.3.3 - Interior Finishes Interior wall and ceiling finishes - (Exits and exit access corridors) Class A or B Class A or B Interior wall and ceiling finishes - (Occupied Spaces) Class A,B,C Class A,B,C Portable Fire Extinguishers (NFPA 101 Table 3 -2.1) <75' apart <75' apart 2010 Florida Building Code -Existing Allowed/ Required Provided M V LA Classification of Work - Alteration - LEVEL 2 r� drawn by: Reconiguralion of Space - Less than 50% of building area being altered P9 e9 LJ L-1 cc "Provisions of Level 1(Chap 6) shall also apply CV O 04 Previous Occupancy - Business / New Occupancy - Business 704 - Fire Protection 04 C14 Automatic sprinkler systems shall be provided in all work areas in accordance with the Florida Building Code, Building. Design Ref Florida Fire Prevention Code. See Performance Compliance YES 706 - Accessibility A building, facility, or element that is altered shall comply with the FBC, Accessibility YES The contractor shall make available b the building inspecbr any documentation necessary b verify that all products requiring approval per FS 533.842 are in compliance. OCCUPANCY CLASSIFICATION GROUND FLOOR (N.I.C.) GROUP M USABLE SQUARE FOOTAGE = 14,700 SQ. FT. LIFE SAFETY OCCUPANT LOAD (N.F.P.A. 101 CHAPTER 7.3.1.2) 1 PERSON PER 100 SQ. FT. OF GROSS FLOOR AREA 14,700 SF/ 100 = 147 PERSONS SECOND FLOOR GROUP B (BUSINESS) USABLE SQUARE FOOTAGE = 15,289 SQ. FT. LIFE SAFETY OCCUPANT LOAD (N.F.P.A. 101 CHAPTER 7.3.1.2) 1 PERSON PER 100 SQ. FT. OF GROSS FLOOR AREA 13,584'SF/ 100 = 135.8 PERSONS. BREAK ROOM =1,035 / 15 = 69 WELCOME = 670 / 5 = 134 TOTAL =338 PERSONS a A III 0 r� / �Orditl'AR4 i�J C t VAVa L'riBTAN W V p...,.....—...,_...—._—,.:—.........—.... —,..,....,_ _—_—_—,..—...m...,__—,...- A� ti � \4 4� W sPAa� . + . + Y t €' i t , , VACANT RETAIL SPCE t aco •: + - � SCOPE OF WORK AREA �' ?' " �;,1 '• � [t S V .'[ �j>i R � ^ a, �1rYk2f IA �.�p• . �'• zY4 '+ 2 t 1 1 dM g { C �j! J:,� kVAirr'XtiY7RN\Y1{+4T4)U,C ' } E i I-CTr.E SPACE (N1.C.1 AREA IN CONTRACT s` , y 45 rr r" r+' R, r i - rrrr�X � wWx 1 w i owl IT& l t • �r r b ` (tj,tt",j Ci .✓ r �r /.y Y MY, SPACE r MCI *SHADED AREA DENOTES NOT IN CONTRACT 1 st Floor Life Safety Plan Scale: 1/16"=F-0" MAX TRAVEL DISTANCE = 74' ; 0 ©� ^� ( ; ; I __a___I____._- -- -- -- -------� 1 _ � - ,_ I 10, 101 cc, id b,,-, �4- --- I TRAVEL DISTANCE= 127 l ' - - - - - +- -- FEC �--------- ---------- = - - - -� \, - - - -- - 1 ` I I I f /; I `. 164 11 Q f/ Ay ,/ / /// / / / / / / /// Q _L -_ __ _�__ > P.C.C. CO N PATH = 91' - -- 1 ff X 41i MAX TRAVEL s.A = O dT lit ` � �/ DISTANCE = 43' PEN TO BELOW 10k N FEC CD OPEN TO BELOW .c. A ^ IN I.C.) 1 ``X A x; MAX TRAVEL / DISTANCE = 72' c \\� *SHADED AREA DENOTES NOT IN CONTRACT 2nd Floor Life Safety Plan Scale: 1/ 1 6"= F-O" LIFE SAFETY LEGEND: XX FEC Coot.- � ACCESSORY ASSEMBLY USE EXIT SIGNAGE NO. OF OCCUPANTS THROUGH EXIT FIRE EXTINGUISHER CABINETS * *LARSERNS FULLY - RECESSED FIRE EXTINGUISHER CABINET & FIRE EXTINGUISHER SS2409 -5R ARCHITECTURAL CABINET; MP -5 5LB. FIRE EXTINGUISHER. STAINLESS STEEL FINISH N Z Ncoo o ��T. O �1�0 F — M UJI N�`0 O N LU Z > LL Q g Q Q n- J w U Jo wo U °° w — r_ a M gdZ \� 2 00 O UU- No) U \ \\��� Q .� .. - CV M V LA 10 r� drawn by: V P9 e9 LJ L-1 cc cheked by: CV O 04 (] 04 C14 MAX TRAVEL DISTANCE = 74' ; 0 ©� ^� ( ; ; I __a___I____._- -- -- -- -------� 1 _ � - ,_ I 10, 101 cc, id b,,-, �4- --- I TRAVEL DISTANCE= 127 l ' - - - - - +- -- FEC �--------- ---------- = - - - -� \, - - - -- - 1 ` I I I f /; I `. 164 11 Q f/ Ay ,/ / /// / / / / / / /// Q _L -_ __ _�__ > P.C.C. CO N PATH = 91' - -- 1 ff X 41i MAX TRAVEL s.A = O dT lit ` � �/ DISTANCE = 43' PEN TO BELOW 10k N FEC CD OPEN TO BELOW .c. A ^ IN I.C.) 1 ``X A x; MAX TRAVEL / DISTANCE = 72' c \\� *SHADED AREA DENOTES NOT IN CONTRACT 2nd Floor Life Safety Plan Scale: 1/ 1 6"= F-O" LIFE SAFETY LEGEND: XX FEC Coot.- � ACCESSORY ASSEMBLY USE EXIT SIGNAGE NO. OF OCCUPANTS THROUGH EXIT FIRE EXTINGUISHER CABINETS * *LARSERNS FULLY - RECESSED FIRE EXTINGUISHER CABINET & FIRE EXTINGUISHER SS2409 -5R ARCHITECTURAL CABINET; MP -5 5LB. FIRE EXTINGUISHER. STAINLESS STEEL FINISH N Z Ncoo o ��T. O �1�0 F — M UJI N�`0 O N LU Z > LL Q g Q Q n- J w U Jo wo U °° w — r_ a M gdZ \� 2 00 O UU- No) U \ \\��� Q .� .. - Z w o U 0 0 ? o K O m <H Er w w o' 0 LL 0 V) N N U Z Z W :�iL Z I..L W Z W W V) 0 0 C 00 U Lr) N CV M V) N N M Z N M N ,� J LL. Q� E CL o5 V wo D ~L0V° z cri CL J CHRISTIAN A. VIDAL, Al A iy LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: CV M V LA 10 r� drawn by: V �T cc cheked by: CV O 04 (] 04 C14 0 0 Z w o U 0 0 ? o K O m <H Er w w o' 0 LL 0 V) N N U Z Z W :�iL Z I..L W Z W W V) 0 0 C 00 U Lr) N CV M V) N N M Z N M N ,� J LL. Q� E CL o5 V wo D ~L0V° z cri CL J CHRISTIAN A. VIDAL, Al A iy LICENSE NO. AR96861 ARCHITECT CONSULTANT scale: as shown release date: April 18, 2014 drawn by: cc cheked by: CV LS -1.0 SHEET NO.