14-481-015i i i i DESIGN CRITERIA PROJECT DESCRIPTION INTERIOR OFFICE BUILD OUT IN AN EXISTING COMMERCIAL BUILDING, NO STRUCTURAL OR EXTERIOR SCOPE OF WORK. BUILDING IS FULLY SPRINKLED APPLICABLE CODES FLORIDA BUILDING CODE, BUILDING (FBC -B) FLORIDA BUILDING CODE, EXISTING BUILDING (FBC -EB) FLORIDA BUILDING CODE, MECHANICAL FLORIDA BUILDING CODE, FUEL GAS FLORIDA BUILDING CODE, PLUMBING FLORIDA FIRE PREVENTION CODE (FFPC) BASED ON N.F.P.A 101 (2009) NATIONAL ELECTRICAL CODE (NEC) FLORIDA ACCESSIBILITY CODE BASED ON 2010 ACCESSIBILITY CODE NOTE: IN ADDITION ALL WORK TO CONFORM TO APPLICABLE TRADE CODES, LAW & REGULATIONS. 2010 EDITION 2010 EDITION 2010 EDITION 2010 EDITION 2010 EDITION 2010 EDITION 2008 EDITION 2012 EDITION BUILDING DESCRIPTION CLASSIFICATION OF WORK = ALTEZATION LEVEL 2 PER F.E.B.C. 2010, SECTION 404 3 STORIES BUILDING (TYPE II) PER 503 TABLE F.B.C. (2010) *THIS BUILDING IS FULLY SPRINKLER CLASS OF REHABILITATION OF WCRK = MODIFICATION PER N.F.P.A. 101 CHAPTER 43 LEGAL DESCRIPTION: CARVERS SUB PB 6 -36 ALL BLK 1 LISS E & S35FT OF LOTS 16 & 19 LYG E OF 18 & LOT 18 & PORT LOT 33 PER DB 3860 -556 & ALL BLK 2 LESS LOTS 14 THRU 16 INC & ALLEY BET BLKS & LESS BEG 111.33FTE OF NW COR OF LOf 22 BLK 2 TH N 60 DEG E 19.09FT N 46 DEG E 120.76FT ELY AD 36.85FT N 07 DEG W 25.08FT S 45 DEG W 187.90FT TO POB & LESS ELEV PARC K/A THE RESID AT SUNSET PL CONDO NAU 09- 4025 -078 PER OR 23224 -2818 LOT SIZE 451468 SQ FT OR 16885- 0996 -1000 0895 6 YEAR BUILT 1999 ZONING COMPLIANCE THIS IS AN INTERIOR RENOVATION ONLY. NO ALTERATIONS WILL BE MADE TO EXISTING FACADES OF BUILDING. NOTE: CONTRACTOR SHALL PROVIDE ANY INFORMATION AND /OR PRODUCT APPROVAL NUMBERS AS REQUIRED BY FLORIDA STATUTE 553.842 AND FLORIDA ADMINISTRATIVE CODE 9B -72 DRAWING INDEX SHEET DRAWING TITLE CS COVER SHEET DEMOLITION D -1.0 DEMOLITION PLAN & NOTES (UNDER SEPARATE COVER) LIFE SAFETY PLAN ARCHITECTURAL A -1.0 GENERAL NOTES A -1.1 FIRE SYSTEMS A -2.1 FIRST FLOOR CONSTRUCTION PLAN A -2.2 SECOND FLOOR CONSTRUCTION PLAN A -2.3 WALL SECTIONS & DETAILS A -2.4 WALL SECTIONS & DETAILS A -2.5 DOOR SCHEDULE & ELEVATIONS A -2.6 DOOR DETAILS A -3.1 REFLECTED CEILING PLAN A -3.2 REFLECTED CEILING DETAILS A -4.1 ELECTRICAL LOCATION PLAN A -5.0 SCHEDULES A -5.1 FINISH PLAN & FINISH SCHEDULE A -6.1 INTERIOR ELEVATIONS & DETAILS A -6.2 INTERIOR ELEVATIONS & DETAILS A -6.3 INTERIOR ELEVATIONS & DETAILS A -6.4 INTERIOR ELEVATIONS & DETAILS A -6.5 INTERIOR ELEVATIONS & DETAILS A -6.6 INTERIOR ELEVATIONS & DETAILS A -6.7 INTERIOR ELEVATIONS & DETAILS A -6.8 RR ENLARGED PLAN, INTERIOR ELEVATIONS & DETAILS A -6.9 RR ENLARGED PLAN, INTERIOR ELEVATIONS & DETAILS A -6.10 MILLWORK & INTERIOR SECTIONS ELECTRICAL E -0 SYMBOLS AND GENERAL ELECTRICAL NOTES E -1 ELECTRICAL POWER PLAN E -2 PARTIAL ROOF PLAN AND ELECTRICAL SERVICE PLAN E -3 ELECTRICAL LIGHTING PLAN E -4 PANELS E -5 PANELS E -6 RISER AND PANELS MECHANICAL TYPICALS M -0 MECHANICAL PLAN DEMOLITION M -1 MECHANICAL PLAN NEW WORK AND PARTIAL ROOF PLAN M -2 SYMBOLS, SCHEDULE AND GENERAL NOTES M -3 CONTROL DIAGRAMS M -4 DETAILS P -1 PLUMBING PLAN DEMOLITION AND PLUMBING PLAN P -2 WATER AND SANITARY RISERS DIAGRAMS P -3 SYMBOLS, SCHEDULE, DETAILS AND GENERAL NOTES FIRE PROTECTION FP -I FIRE SPRINKLER PLAN - 2nd FLOOR FP -2 FIRE SPRINKLER PLAN - 1st FLOOR FIRE ALARM NOTES NOTES FA01 PARTIAL FIRE ALARM SYSTEM RISER 1 MAIN MALL RISER RISER 2 SHIVER RISER & BATTERY CALC TYP1 TYPICALS TYP2 TYPICALS TYP3 TYPICALS TYPO TYPICALS TYPS TYPICALS F co z W z O U Z W d' W W LL C 3 LL u c c u 0 0 u c c U z Z w :2i Z Q w Z w w 2 N 0 0 c 00 U N Lr) N N M W N N Z dj c V) • = LL. a C) ._ E CL o D Lur"o F-- Iry Lu O LL 0 Lu V) V) CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT SHEET NO. cs Z Qc) CVOOp N 000,q- 80, oQ W� O >O Low= Z w Z to ch o Z aw Novo N U cv) N 0 Z = J Lu U > 3 a a CL Lu w J U J o CL w p w U c') W K m . \ cgcoiU Q_ J U z Z w :2i Z Q w Z w w 2 N 0 0 c 00 U N Lr) N N M W N N Z dj c V) • = LL. a C) ._ E CL o D Lur"o F-- Iry Lu O LL 0 Lu V) V) CHRISTIAN A. VIDAL, AIA LICENSE NO. AR96861 ARCHITECT SHEET NO. cs