14-481-0050 THE SHOPS AT SUNSET - SHIVER • ENTERTAINMENT 4010es FACP 0.0000 Powered By Ext. Source 0.0650 Module Qty Module Qty Description Qty. Standby Current Total Standby Alarm Current Total Alarm Panel Equipment 1 1 JLCD ANNUN FOR 4010ES FACP (RUI) HEAT DET VERT N/0 302 -ET -135 SINGLE ACTION CAST PULL STATION SPST 0 1 0.0650 1 0.1400 2098 -9490 1 2 4010 -9402 1 FACP, 248PT IDNET, 1 BAY, 120V, PLATINUM • 2099 -9138 1 0.3160 0.3160 0.4300 0.4300 4010 -9912 1 SERIAL DACT WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) 0 75 Celsius 0.0300 0.0300 0.0400 1 0.0400 Panel Totals IDNet Addressable Devices SLC MC V/0 WP A/V 0.3460 MC CEIL A/V 0.4700 4099 -9001 2 JIDNET SINGLE ACTION PULL STA11ON • Device 0.0000 0.0000 0.0000 0.0000 4090 -9002 7 IDNET RELAY IAM • cD Q IN 0.0000 0.0000 0.0000 0.0000 4090 -9051 3 IDNET E- SERIES SUPERVISED IAM • Quantity 0.0000 0.0000 0.0000 0.0000 4098 -9714 6 TRUEALARM PHOTO SMOKE SENSOR 0.2490 0.0860 0.0000 0.0000 0.0000 0.0000 4098 -9733 1 TRUEAIARM HEAT SENSOR Power Plan Dist. (D) Wire Wire Res. Total V. Drop 0.0000 0.0000 0.0000 0.0000 4098 -9755 1 TRUEAIARM DUCT SMOKE SENSOR W/O RELAY OUTPUT • J 0.0000 0.0000 0.0000 0.0000 4098 -9792 1 7 ITRUEALARM SENSOR BASE ; A•2D•R 0 End 0.0000 0.0000 0.0000 0.0000 Miscellaneous Peripheral Devices That May Require System Power Ow 4606 -9102 1 ILCD ANNUN FOR 4010ES FACP RUI Branch 2ND k 1ST FLOOR STROBES 0.0650 0.0650 0.1400 0.1400 2098 -9490 2 1HEAT DET VERT N10 302 -ET -135 16.067 17.60% 0.0000 0.0000 0.0000 0.0000 2099 -9138 1 SINGLE ACTION CAST PULL STATION SPST 0 2 0.0000 0.0000 0.0000 0.0000 Notification Appliances 4010es SIG2 335 14ga 0,0031 1.398 2.876 4906 -9103 15 V/0 MC NON- ADDRESS, WHT, WALL 15 6 0.0000 0.0000 0.0600 0.9000 4906 -9103 2 V/0 MC NON- ADDRESS, WHIT, WALL 30 17.87 0.0000 0.0000 0.0940 0.1 B80 4906 -9130 3 A/V MC NON- ADDRESS, WHT, CEILING 110 3.457 0.0000 0.0000 0.3200 0.9600 4906 -9130 4 A/V MC NON- ADDRESS, WIRT, CEILING 15 0 0.0000 0.0000 0.0860 0.3440 4906 -913D 3 A/V MC NON- ADDRESS, WHT, CEILING 30 I SIG4 0.0000 0.0000 0.1320 0.3960 4906 -9130 6 A/V MC NON- ADDRESS, WHT, CEILING 75 0 Ft. 0.0000 0.0000 0.2500 1.5000 4906 -9131 1 JWP MC A/V NON -ADDR WALL MT RED 75 19.5 0.0000 0.0000 0.2490 0.2490 Peripheral Totals ' m 0.0650 4.6770 z Added Current for EPS Conversion of 24 to 29 Volt IDNac Devices 0.0000 0.0000 LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN RUI Totals 0 0.0000 0.0000 Address Totals 20 Addresses 0.0160 0.0200 Select ALL Power Supplies on this battery set: 4010es Sub Total Additional Current Draws: MAPNET /IDNet Device Addresses ordered / used 20 x 0.000800 Sub Total Spare addressable point capacity 09: 0 x 0.0008 Total S -ondby Time = 24 Hrs x 0.4270 Alarm Time = 5 Min 0.08333 x 5.167 Additional Spare Battery Capacity = 07 + Battery Discharge Factor = 207 + Minimum Battery Required 2081 -9275 18AH (2x) Battery Supplied 2081 -9275 18AH 2x 0.4270 j 0.4110 0.4110 = 0.0160 x 0.001000 0.4270 = 0.0000 x 0.001 0.4270 = 10.2480 Standby Ah = 0.4306 Alarm M 10.6786 0.0000 10.6786 2.1357 12.8143 5.1670 5.1470 5.1470 = 0.0200 5.1670 = 0.0000 5.1670 a , POWER SUPPLY SUMMARY 0.0000 Powered By Ext. Source 0.0650 Module Qty Description Standby Current Alarm Current Qty. MISCELLANEOUS 24VDC PERIPHERALS 1 0.0300 0.0400 4606 -9102 1 1 JLCD ANNUN FOR 4010ES FACP (RUI) HEAT DET VERT N/0 302 -ET -135 SINGLE ACTION CAST PULL STATION SPST 0 1 0.0650 1 0.1400 2098 -9490 1 2 0 0.0000 0.0000 2099 -9138 1 0 1 0.0000 0.0000 4010 -9402 1 FACP, 248PT IDNET, 1 BAY, 120V, PLATINUM 4010 -9912 1 SERIAL DACT 1 0.0300 1 0.040( Comp( NAC Currents from Voltage Current for Conversion of Battery Voltage to 29 volt EPS IDNAC D MAPNET /IDNet Device Addresses 401Oes SUMMARY Total Total '1. 0.0000 0.0000 0.0650 0.1400 4906 -9103 4906 -9103 1 0.3160 0.4300 1 0.0300 0.0400 0.3460 0.0000 0.0000 20 0.0160 0.4700 4.5370 0.0000 0.0200 Total 0.4110 5.1470 Capacity: 8.000A Ckt. Copacity: 3.000A Aux. Capocity: 2.000A 0 THE SHOPS AT SUNSET - SHIVER ENTERTAINMENT 4010es FACP VOLTAGE DROPS PID 4906 -9103 4906 -9103 4906 -9131 4906 -9130 4906 -9130 4906 -9130 4906 -9130 Cn 1� Candela 15cd 30cd 75cd 15cd 30cd 75cd 110cd W WIRE RESISTANCE BASED ON TABLE 8 FROM NATIONAL ELECTRICAL CODE (UNCOATED SOLID COPPER WIRE) 0 75 Celsius Device Type MC V/0 MC V/0 WP A/V MC CEIL A/V MC CEIL A/V MC CEIL A/V MC CEIL A/V \� Minimum Device Supv. Current cD Q IN W Lo W Voltage 0 Spare Quantity M �v ICY) O Alarm Current 0.0600 0.0940 0.2490 0.0860 0.1320 0.2500 0.3200 Circuit NAG Circuit / Per Power Plan Dist. (D) Wire Wire Res. Total V. Drop Volt 7 Volt Min Device Max o. IC V Cl) m J ,� Capacity Output Branch Circuit/ NOTIFICATION CIRCUIT DESCRIPTION Supply Ckt. Feet Gouge Ft. R Alarm A A•2D•R 0 End Drop Voltage Distance Ow (Amps) Terminals Capacity Branch 2ND k 1ST FLOOR STROBES 401 Des SIG1 360 14ga 0,0031 1.553 3.433 16.067 17.60% 16vdc 367 Ft. 6 0 1 2 1 0 2 3A 19.5 1.97 1 12 2ND FLOOR STROBES 4010es SIG2 335 14ga 0,0031 1.398 2.876 16.624 14.75% 16vdc 408 Ft. 6 2 0 1 2 2 0 3A 19.5 17.87 13 2ND FLOOR STROBES 4010es SIG3 355 14ga 0,0031 1.586 3.457 16.043 17.737 16vdc 359 Ft. 1 3 0 0 1 0 4 1 3A 19.5 1.17 9 SPARE 14010es I SIG4 I 14gal 0.0031 1-0.0001 o 19.5001 0.00%1 16vdc 0 Ft. z 3A 19.5 100.07 0 NOTE: ' m ••. z ; H 0 LUMP SUM METHOD WAS USED TO CALCULATE ALLOWABLE VOLTAGE DROP. THIS METHOD ALLOWS FOR A SMALL MARGIN � M OF SAFETY, TAKING INTO CONSIDERATION THAT THE ACTUAL INSTALLED CIRCUIT ROUTING MAY DIFFER FROM WHAT IS SHOWN � d ON THE SHOP DRAWINGS. IF THE ACTUAL CIRCUIT LENGTH IS GOING TO EXCEED THE MAXIMUM ALLOWABLE CIRCUIT (� w s 4hll{{{{``� N W LENGTH, CONTACT YOUR LOCAL SIMPLEXGRINNELL DISTRICT OFFICE. O � a w W ~ ui F j W t�A z Z BATTERY CALCS I ---i ZZ L 15 15 15 SIG3 ACTUAL 1.586 AMPS EOL SIG3 1 11 11 15 110 75 75 75 75 MAX 3.000 AMPS 10K C C C C C C i i i INTERIOR MODIFICATIONS ONLY (ANY EXTERIOR MODIFICATION MAY REQUIRE A BOARD APPEARANCE) 15 15 15 75 15 30 15 30 15 15 30 30 75 L SIG2 ACTUAL 1.398 AMPS EOL SIG2 MAX 3.000 AMPS 10K SCOPE OF WORK C3 CP 5`G� DN iC MP FAA M1 INTERFACE -9A MAIN CP O p0?, �5 ' X AHU Fu BF Q ` 4 � � � ` T C SHUTDOWN ALARM TROUBLE SUPERVISORY ` t L 110 15 15 15 15 15 15 110 30 15 15 L MNSU i o �T�_c ,�T, ,�;! C C c c C F F 2 2 2 2 2 1 2 0 0 o bled �`° s 1: _: !1, '. Dad °rPn, �r'�it.s• PPr CO t1 �� mac, 5` �� �� 5` 5` �� 5` 5` 5 '� �� '�' '�' �' Die 0Ve to bate `� meto arrli. 5 � � � � � � � � � � � � � d for m D(_ � 1 to ej7 t o 401OES FACP LOCATED IN ELEC. 120 VOLT AC 2ND FLOOR ROOM EX. 1 = DEDICATED CIRCUIT 2ND FLOOR . M1 -14A M1 -15A M1 -16A ELEVATOR WP CONTROLLERS F 11P L MN C PRIMARY ALTERNATE FIRE HAT SIG1 ACTUAL 1.553 AMPS WP 75 EOL SIGt AIM 2 0 0 0 MAX 3.000 AMPS 10K CEO' 1 ST FLOOR 1 ST FLOOR S I -11-1 VER RISER USGMIAMI IIDRAFTING100- 2003VLL100 -2003 CAD DRAWINGSITHE SHOPS AT SUNSET P(ACE4019E71.SUNSET SHOPS SHIVER- REV00- 977170502XSUNSET SHOPS SHIVER - 977170502 DWG DATE CREA7ZD: April 3, 2014 DATE PIA7TED: Apri 7, 2014 DATE SAVED: April 7, 2014 W Cn 1� z Q W MI LLL. \� Q N cD Q IN W Lo W WM�`° J -� LL M co Q 4 M �v ICY) O Z W UQL0 (n (3) U.) O Z Lr) w IL = a V W ' Z Cl) o. IC V Cl) m J ,� ww O zw Ow 75-j �t J oQ O Z H U W U) o o. z O 0 o U) p w V) w o v z ' m ••. z ; H 0 I• � M OOWGG PGA � d pR0 (� w s 4hll{{{{``� N W O � a w W ~ ui F j W t�A z Z N A Q Z a V w d O IL w Y w �Caa w z W ° (O ILL ° N o w � o J Z W U O o ~ g 0 o (n Q r-I o - c°') rZ4 z a -4 c� W z a O °OZ Q L0 J H Z UU z W Q ULI U U Q a ww z Q H U O0 W U O w Fw- 0- 5 WO a 0a �W Q wO 0 I=- ) Z O W U Z ULI Tx J Z J -j O O Z zW Z o E-1 W 0) J J V) W Z � o� z 0 w E-I W W Z OJ (n J a E- _ ca O F- a_ a4 A Q of 0 O .�. � M (D t` z W E���' z;�> za DW Wes,: 0 ��0 z�Z aF w� � oQa �o DRAWN BY: DATE: JS 4/7/14 DESIGNED BY: DATE: APPROVED BY: DATE: PROJECT NUMBER: 263401987 - 977170502 SHEET TITLE/ PATH: SHEET NUMBER: RISER2 SIZE D 124-Xw