14-403R-004=m GENERAL DEMOLITION NOTES 5YM I. THE SECTION 15 INCLUDED FOR GENERAL CONTRACTOR b. G.G. IS TO ERECT CONSTRUCTION BARRICADES AND IF, REFERENCE WORK TO BE PERFORMED BY GENERAL DEBRIS /DUCT 5GREEN5 PER LANDLORDS AJ EXISTING 6" X 20 GA METAL STUDS w 16" O.G. J" TYP "X" CONTRACTOR (G.CJ APPLIED AS NEEDED TO STORE. SPECIFICATIONS. CONTACT LANDLORD'S FIELD z. G.G. IS TO REMOVE ALL EXISTING LEASEHOLD REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL AJ EXISTING INTERIOR PARTITIONS TO REMAIN IMPROVEMENTS A5 REQUIRED TO ACHIEVE SCOPE OF DEMOLITION WORK. WORK NOTES. DEMOLITION INCLUDES, 13UT 15 NOT LIMITED q. WHERE APPLICABLE, 6.0. 15 TO COORDINATE THE TO THE REMOVAL OF ALL EXISTING INTERIOR WALLS, REMOVAL, DISPOSAL, AND /OR RETURN OF ALL EXISTING 0 PARTITIONS, GEILIN65, FLOOR COVERING5, PLATFORMS, SECURITY SYSTEMS WITH LANDLORD'S CONSTRUCTION STOCK AREA : 101 DISPLAY SHOW WINDOWS, CABINETS, ETC. UNLESS NOTED MANAGER PRIOR TO ITS REMOVAL. FAILURE TO DO SUCH 18 OTHERWISE. DEMOLITION AL50 INCLUDES THE REMOVAL COORDINATION WILL RESULT IN G.G.'S MONETARY FINE IN REMOVE FREE STANDING MERCHANDISE DISPLAYS BOLTED TO FLOOR. OF ALL EXISTING ELECTRICAL, MECHANICAL AND THE EQUIVALENCE OF THE COST REPLACEMENT VALUE OF PLUMBING FIXTURES AND EQUIPMENT UNLESS NOTED ON THE EXISTING SECURITY SYSTEM. 19 MECHANICAL AND ELECTRICAL DRAWINGS. IO.G.C. IS TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE 5• ALL ABANDONED ELEGTRIGAL/TELEPHONE CONDUIT, DISCREPANCIES OR IRREGULARITIES DISCOVERED PLUMBING LINES, DRAIN LINES, AND MECHANICAL DURING DEMOLITION WHIGH MIGHT AFFECT THE CURRENT PANEL. SEE ELEGTRIGAL DRAWINC75 FOR SCOPE OF WORK. DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE STORE DESIGN. G.G. 15 TO PAY SPECIAL ATTENTION TO REMOVED. AVAILABLE HEIGHT FOR INTENDED CEILING ELEVATION, 4. C7.0.15 TO COORDINATE THE DISCONNECTION AND MECHANICAL DUGTWORK AND RECESSED LIGHTING. GAPPING OF ANY UTILITIES WITH LANDLORD'S FIELD 11, G.G. IS TO GUT ALL NECESSARY OPENINGS FOR ANY REPRESENTATIVE. REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY. 5• IN ORDER TO CAUSE THE LEAST AMOUNT OF AFTER CUTTING IN 50 FAR AS POSSIBLE ALL INCONVENIENCE, G.G. 15 TO COORDINATE WITH ALL PROTRUSIONS, MARKS, GRACK5, OR OTHER EVIDENCE OF ADJACENT SPACES A CONVENIENT TIME TO PERFORM DAMAGED, DEFICIENT OR UNSAFE CONDITION, ANY PARTS DEMOLITION WORK. G.G. IS TO PROVIDE AND INSTALL ALL WHICH ARE SPLIT, CRACKED, 5PALLED, CHIPPED, BROKEN, TEMPORARY PROTECTED MEANS OF EGRESS. MI551N6, OUT OF LINE OR ADJUSTMENT MECHANICALLY OR TEMPORARY LIGHTING, AND ALL SAFETY DEVIGE5 IN STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR ACCORDANCE WITH ALL STATE AND LOCAL CODES, AND OTHERWISE DEFICIENT OR IN. URED IN ANY MANNER LANDLORD REQUIREMENTS. SHALL BE REMOVED, REPLACED, REPAIRED OR RESTORED SATISFACTORILY AS DIRECTED BY TENANT'S 6. G.G. IS RESPONSIBLE FDR PATCHING AND /OR REPAIRING CONSTRUCTION MANAGER. EXISTING FLOOR SLAB, DEMISING WALLS, AND ROOF DECK AFTER COMPLETION OF ALL DEMOLITION AND 12. G.G. 15 RESPONSIBLE FOR REMOVING ALL DEMOLISHED PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION. ITEMS, DEBRIS, ETC., FROM SITE. G.G. IS RESPONSIBLE C7.0.15 TO COORDINATE WITH LANDLORD FOR PROPERLY DISPOSING OF ALL ITEMS AGGORDIN6 RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF TO ANY APPLICABLE LOCAL OR STATE ORDINANCES. WORK. G.G. 15 TO PATCH, REPAIR AND LEVEL EXISTING FLOOR SLAB AND INFORM TENANT OF ALL SEVERE IRREGULARITIES IN EXI5TIN6 SLAB IMMEDIATELY. 1. G.G. IS TO EXERCISE EXTREME CARE DURING DEMOLITION 50 AS NOT TO DAMAGE OR DISRUPT ANY UTILITIES OR SPRINKLER LINES WHIGH MIGHT PASS THROUGH THIS SPACE TO 5ERVIGE OTHER MALL 5PAGE5 OR OTHER TENANTS. L.L. WILL BEAR SOLE RESPONSIBILITY OF ANY SUCH DISRUPTION OR DAMAGE. WALL TYPE SCHEDULE: EXISTING 5YM DE5GRIPTION :. AJ AJ INTERIOE CONCRETE COLUMN*:_, IF, EX15TINC7 TENANT DEM z> _ AJ AJ EXISTING 6" X 20 GA METAL STUDS w 16" O.G. J" TYP "X" GYP BD. EACH SIDE FULL HEIGHT TO UNDERSIDE OF 2ND EX. FLOOR DECK. UL DESIGN U -465 AJ AJ EXISTING INTERIOR PARTITIONS TO REMAIN = = AJ AJ INTERIOR PARTITION OR ELEMENT TO BE REMOVED EXISTING CONDITIONS /SELECTIVE DEMOLITION EX. STOREFRONT EX. TOILET ROOM: 1C* a EXISTING DRINKING FOUNTAIN TO REMAIN. D EXISTING STOREFRONT ENTRY AND DISPLAY WINDOWS TO REMAIN. IF, EXISTING TOILET ROOM TO REMAIN. TEMPORARILY REMOVE ALL EXISTING FIXTURES REMOVE SECTION OF PARTITIONS WITH RECESSED WALL STANDARDS WHERE SHOWN. BASE CONDITION AND REPLACE AS NEEDED. AND ACCESSORIES FOR REPLACEMENT OF FINISHES. EX. SALES AREA: 100 I-1 EXISTING TOILET ROOM FLOORING TO BE REMOVED COMPLETE. ALL ADHESIVES TO 0 FIELD VERIFY AND REMOVE ANY ABANDONED TENANT FLOOR FIXTURES. BE REMOVED BACK TO SLAB. SLAB 15 TO BE GLEAN, SMOOTH, AND LEVEL READY AND EXPOSED LINE VOLTAGE RECEPTACLE. 1P� FOR NEW FLOORING. 0 REMOVE EXISTING GASH DESK, ALL ELECTRICAL, TEL AND DATA LINES TO BE REMOVED EX. STOCK AREA : 101 I) BACK TO POINT OF SERVICE. OUT GONDUIT5 BELOW FLOOR AND PATCH AND REPAIR FLOOR. 18 REMOVE EXISTING TENANT FIXTURES, SHELVING, ACCESSORIES, AND WALL 5TANDARD� EXISTING CERAMIC TILE FLOORING TO REMAIN THROU6H OUT. REMOVE FREE STANDING MERCHANDISE DISPLAYS BOLTED TO FLOOR. EX. V.I.F. EXTENT OF ABANDONED ITEM5. 13 ALL EXISTING FITTING ROOMS TO BE REMOVED COMPLETE INCLUDING: ALL 19 LOCATION OF EXISTING ELECTRICAL, AND TELEPHONE EQUIPMENT. EXISTING 50 EXISTING RECESSED WALL STANDARDS TO REMAIN, UNLESS OTHERWISE NOTED. CONTACTORS ARE TO BE REMOVED AND REPLACED WITH TENANT LIGHTING CONTROL Ir4 REMOVE ALL WOOD WALL 5A5E THROUGH OUT, PANEL. SEE ELEGTRIGAL DRAWINC75 FOR SCOPE OF WORK. LJ REMOVE EXI5TIN6 FACE GAP TRIM AND HORIZONTAL VALANCE ABOVE. TYPICAL a EXISTING DRINKING FOUNTAIN TO REMAIN. THROUGH OUT. 21 EXISTING VCT FLOORING TO REMAIN UNLESS NOTED OTHERWISE. FIELD VERIFY WALL REMOVE SECTION OF PARTITIONS WITH RECESSED WALL STANDARDS WHERE SHOWN. BASE CONDITION AND REPLACE AS NEEDED. EXISTING SALES / STOCK DOOR TO BE REMOVED COMPLETE. PATCH AND REPAIR PARTITION AS REQUIRED, PREPARE AREA FOR INSTALLATION OF NEW FITTING ROOM 22 EXI5TIN6 SECTION OF FLOORING TO BE REMOVED. ALL ADHESIVES TO BE REMOVED BACK TO SLAB. SLAB IS TO BE GLEAN SMOOTH, AND LEVEL, READY FOR NEW CASED OPENING. FLOORING. ffJ REMOVE EXI5TIN6 5EN50RMATIC PEDESTALS WITH ASSOCIATED LOW- VOLTAGE AND EXPOSED LINE VOLTAGE RECEPTACLE. 1P� EXI5TIN6 COLUMN ENCLOSURES TO REMAIN. PATCH ND REPAIR AS REQUIRED READY FOR TENANT FINISHES. I) REMOVE ALL WOOD WALL BASE THROUGH OUT. 14 EXISTING CERAMIC TILE FLOORING TO REMAIN THROU6H OUT. EX. FITTING ROOMS 101/102 13 ALL EXISTING FITTING ROOMS TO BE REMOVED COMPLETE INCLUDING: ALL PARTITIONS, DOOR/GURTAIN5, FRAMES, HARDWARE, FIXTURES, AND ACCESSORIES. ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND MADE SAFE. Ir4 REMOVE ALL WOOD WALL 5A5E THROUGH OUT, 15 EXISTING CERAMIC TILE FLOORING TO REMAIN THROUGH OUT. rAal PLAN NORTH 0000 ••• . . 0.0 00 0.0 DA E:-** •3 /ca /1 • V • • V JOB NO: 14 -015 • ••• • W • • DRAWN-,. • 5 AFF `: 0 w 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 LICENSE No. AR- 0015586 PRa ECT COM MTM (ADDT'cCrtv 1 OAIaYD IIDAD, IUIIE is ),T& (w) M K10 Lu W O LL cn Wq x z LU w J cn s; Oct) ­A .., r zI-- a Cl) c') N Qvb < L "' o z 0 c/) w � GL qr- 0 Q LLJ Cl� _ � Q O U) co �- STORE NUMBER ■ ■ ■ ISSUE 'A' -ISSUE LL, DID, PERMIT DATE 3/28/14 W -ISSUE TENANT CHANGE DATE 5/12/14 'C'- -ISSUE BUILDING COMMENT DATE 5/14/14 'D' -ISSUE DATE 'E' -ISSUE DATE SHEET TITLE EX. CONDITIONS / SELECTIVE DEMO. FLOOR PLAN SCALE 1/4' =1' -0' SHEET NUMBER A0.1 mmwm�_