14-403R-004=m
GENERAL DEMOLITION NOTES
5YM
I.
THE SECTION 15 INCLUDED FOR GENERAL CONTRACTOR
b. G.G. IS TO ERECT CONSTRUCTION BARRICADES AND
IF,
REFERENCE WORK TO BE PERFORMED BY GENERAL
DEBRIS /DUCT 5GREEN5 PER LANDLORDS
AJ EXISTING 6" X 20 GA METAL STUDS w 16" O.G. J" TYP "X"
CONTRACTOR (G.CJ APPLIED AS NEEDED TO STORE.
SPECIFICATIONS. CONTACT LANDLORD'S FIELD
z.
G.G. IS TO REMOVE ALL EXISTING LEASEHOLD
REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL
AJ EXISTING INTERIOR PARTITIONS TO REMAIN
IMPROVEMENTS A5 REQUIRED TO ACHIEVE SCOPE OF
DEMOLITION WORK.
WORK NOTES. DEMOLITION INCLUDES, 13UT 15 NOT LIMITED
q. WHERE APPLICABLE, 6.0. 15 TO COORDINATE THE
TO THE REMOVAL OF ALL EXISTING INTERIOR WALLS,
REMOVAL, DISPOSAL, AND /OR RETURN OF ALL EXISTING
0
PARTITIONS, GEILIN65, FLOOR COVERING5, PLATFORMS,
SECURITY SYSTEMS WITH LANDLORD'S CONSTRUCTION
STOCK AREA : 101
DISPLAY SHOW WINDOWS, CABINETS, ETC. UNLESS NOTED
MANAGER PRIOR TO ITS REMOVAL. FAILURE TO DO SUCH
18
OTHERWISE. DEMOLITION AL50 INCLUDES THE REMOVAL
COORDINATION WILL RESULT IN G.G.'S MONETARY FINE IN
REMOVE FREE STANDING MERCHANDISE DISPLAYS BOLTED TO FLOOR.
OF ALL EXISTING ELECTRICAL, MECHANICAL AND
THE EQUIVALENCE OF THE COST REPLACEMENT VALUE OF
PLUMBING FIXTURES AND EQUIPMENT UNLESS NOTED ON
THE EXISTING SECURITY SYSTEM.
19
MECHANICAL AND ELECTRICAL DRAWINGS.
IO.G.C. IS TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE
5•
ALL ABANDONED ELEGTRIGAL/TELEPHONE CONDUIT,
DISCREPANCIES OR IRREGULARITIES DISCOVERED
PLUMBING LINES, DRAIN LINES, AND MECHANICAL
DURING DEMOLITION WHIGH MIGHT AFFECT THE CURRENT
PANEL. SEE ELEGTRIGAL DRAWINC75 FOR SCOPE OF WORK.
DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE
STORE DESIGN. G.G. 15 TO PAY SPECIAL ATTENTION TO
REMOVED.
AVAILABLE HEIGHT FOR INTENDED CEILING ELEVATION,
4.
C7.0.15 TO COORDINATE THE DISCONNECTION AND
MECHANICAL DUGTWORK AND RECESSED LIGHTING.
GAPPING OF ANY UTILITIES WITH LANDLORD'S FIELD
11, G.G. IS TO GUT ALL NECESSARY OPENINGS FOR ANY
REPRESENTATIVE.
REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY.
5•
IN ORDER TO CAUSE THE LEAST AMOUNT OF
AFTER CUTTING IN 50 FAR AS POSSIBLE ALL
INCONVENIENCE, G.G. 15 TO COORDINATE WITH ALL
PROTRUSIONS, MARKS, GRACK5, OR OTHER EVIDENCE OF
ADJACENT SPACES A CONVENIENT TIME TO PERFORM
DAMAGED, DEFICIENT OR UNSAFE CONDITION, ANY PARTS
DEMOLITION WORK. G.G. IS TO PROVIDE AND INSTALL ALL
WHICH ARE SPLIT, CRACKED, 5PALLED, CHIPPED, BROKEN,
TEMPORARY PROTECTED MEANS OF EGRESS.
MI551N6, OUT OF LINE OR ADJUSTMENT MECHANICALLY OR
TEMPORARY LIGHTING, AND ALL SAFETY DEVIGE5 IN
STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR
ACCORDANCE WITH ALL STATE AND LOCAL CODES, AND
OTHERWISE DEFICIENT OR IN. URED IN ANY MANNER
LANDLORD REQUIREMENTS.
SHALL BE REMOVED, REPLACED, REPAIRED OR
RESTORED SATISFACTORILY AS DIRECTED BY TENANT'S
6.
G.G. IS RESPONSIBLE FDR PATCHING AND /OR REPAIRING
CONSTRUCTION MANAGER.
EXISTING FLOOR SLAB, DEMISING WALLS, AND ROOF
DECK AFTER COMPLETION OF ALL DEMOLITION AND
12. G.G. 15 RESPONSIBLE FOR REMOVING ALL DEMOLISHED
PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION.
ITEMS, DEBRIS, ETC., FROM SITE. G.G. IS RESPONSIBLE
C7.0.15 TO COORDINATE WITH LANDLORD
FOR PROPERLY DISPOSING OF ALL ITEMS AGGORDIN6
RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF
TO ANY APPLICABLE LOCAL OR STATE ORDINANCES.
WORK. G.G. 15 TO PATCH, REPAIR AND LEVEL EXISTING
FLOOR SLAB AND INFORM TENANT OF ALL SEVERE
IRREGULARITIES IN EXI5TIN6 SLAB IMMEDIATELY.
1.
G.G. IS TO EXERCISE EXTREME CARE DURING DEMOLITION
50 AS NOT TO DAMAGE OR DISRUPT ANY UTILITIES OR
SPRINKLER LINES WHIGH MIGHT PASS THROUGH THIS
SPACE TO 5ERVIGE OTHER MALL 5PAGE5 OR OTHER
TENANTS. L.L. WILL BEAR SOLE RESPONSIBILITY OF ANY
SUCH DISRUPTION OR DAMAGE.
WALL TYPE SCHEDULE: EXISTING
5YM
DE5GRIPTION
:. AJ
AJ INTERIOE CONCRETE COLUMN*:_,
IF,
EX15TINC7 TENANT DEM
z> _ AJ
AJ EXISTING 6" X 20 GA METAL STUDS w 16" O.G. J" TYP "X"
GYP BD. EACH SIDE FULL HEIGHT TO UNDERSIDE OF 2ND
EX.
FLOOR DECK. UL DESIGN U -465
AJ
AJ EXISTING INTERIOR PARTITIONS TO REMAIN
= = AJ
AJ INTERIOR PARTITION OR ELEMENT TO BE REMOVED
EXISTING CONDITIONS /SELECTIVE DEMOLITION
EX. STOREFRONT
EX. TOILET ROOM: 1C*
a EXISTING DRINKING FOUNTAIN TO REMAIN.
D
EXISTING STOREFRONT ENTRY AND DISPLAY WINDOWS TO REMAIN.
IF,
EXISTING TOILET ROOM TO REMAIN. TEMPORARILY REMOVE ALL EXISTING FIXTURES
REMOVE SECTION OF PARTITIONS WITH RECESSED WALL STANDARDS WHERE SHOWN.
BASE CONDITION AND REPLACE AS NEEDED.
AND ACCESSORIES FOR REPLACEMENT OF FINISHES.
EX.
SALES AREA: 100
I-1
EXISTING TOILET ROOM FLOORING TO BE REMOVED COMPLETE. ALL ADHESIVES TO
0
FIELD VERIFY AND REMOVE ANY ABANDONED TENANT FLOOR FIXTURES.
BE REMOVED BACK TO SLAB. SLAB 15 TO BE GLEAN, SMOOTH, AND LEVEL READY
AND EXPOSED LINE VOLTAGE RECEPTACLE.
1P�
FOR NEW FLOORING.
0
REMOVE EXISTING GASH DESK, ALL ELECTRICAL, TEL AND DATA LINES TO BE REMOVED
EX.
STOCK AREA : 101
I)
BACK TO POINT OF SERVICE. OUT GONDUIT5 BELOW FLOOR AND PATCH AND REPAIR
FLOOR.
18
REMOVE EXISTING TENANT FIXTURES, SHELVING, ACCESSORIES, AND WALL 5TANDARD�
EXISTING CERAMIC TILE FLOORING TO REMAIN THROU6H OUT.
REMOVE FREE STANDING MERCHANDISE DISPLAYS BOLTED TO FLOOR.
EX.
V.I.F. EXTENT OF ABANDONED ITEM5.
13
ALL EXISTING FITTING ROOMS TO BE REMOVED COMPLETE INCLUDING: ALL
19
LOCATION OF EXISTING ELECTRICAL, AND TELEPHONE EQUIPMENT. EXISTING
50
EXISTING RECESSED WALL STANDARDS TO REMAIN, UNLESS OTHERWISE NOTED.
CONTACTORS ARE TO BE REMOVED AND REPLACED WITH TENANT LIGHTING CONTROL
Ir4
REMOVE ALL WOOD WALL 5A5E THROUGH OUT,
PANEL. SEE ELEGTRIGAL DRAWINC75 FOR SCOPE OF WORK.
LJ
REMOVE EXI5TIN6 FACE GAP TRIM AND HORIZONTAL VALANCE ABOVE. TYPICAL
a EXISTING DRINKING FOUNTAIN TO REMAIN.
THROUGH OUT.
21 EXISTING VCT FLOORING TO REMAIN UNLESS NOTED OTHERWISE. FIELD VERIFY WALL
REMOVE SECTION OF PARTITIONS WITH RECESSED WALL STANDARDS WHERE SHOWN.
BASE CONDITION AND REPLACE AS NEEDED.
EXISTING SALES / STOCK DOOR TO BE REMOVED COMPLETE. PATCH AND REPAIR
PARTITION AS REQUIRED, PREPARE AREA FOR INSTALLATION OF NEW FITTING ROOM
22 EXI5TIN6 SECTION OF FLOORING TO BE REMOVED. ALL ADHESIVES TO BE REMOVED
BACK TO SLAB. SLAB IS TO BE GLEAN SMOOTH, AND LEVEL, READY FOR NEW
CASED OPENING.
FLOORING.
ffJ
REMOVE EXI5TIN6 5EN50RMATIC PEDESTALS WITH ASSOCIATED LOW- VOLTAGE
AND EXPOSED LINE VOLTAGE RECEPTACLE.
1P�
EXI5TIN6 COLUMN ENCLOSURES TO REMAIN. PATCH ND REPAIR AS REQUIRED READY
FOR TENANT FINISHES.
I)
REMOVE ALL WOOD WALL BASE THROUGH OUT.
14
EXISTING CERAMIC TILE FLOORING TO REMAIN THROU6H OUT.
EX.
FITTING ROOMS 101/102
13
ALL EXISTING FITTING ROOMS TO BE REMOVED COMPLETE INCLUDING: ALL
PARTITIONS, DOOR/GURTAIN5, FRAMES, HARDWARE, FIXTURES, AND ACCESSORIES.
ALL ELECTRICAL TO BE REMOVED BACK TO NEAREST J -BOX AND MADE SAFE.
Ir4
REMOVE ALL WOOD WALL 5A5E THROUGH OUT,
15
EXISTING CERAMIC TILE FLOORING TO REMAIN THROUGH OUT.
rAal
PLAN
NORTH
0000 ••• . . 0.0 00 0.0
DA E:-** •3 /ca /1 • V • • V
JOB NO: 14 -015
• ••• • W • •
DRAWN-,. • 5 AFF `: 0
w
711 N. FIELDER RD.
ARLINGTON, TX 76012
PH: (817) 635 -5696
FAX: (817) 635 -5699
LICENSE No. AR- 0015586
PRa ECT COM MTM
(ADDT'cCrtv
1 OAIaYD IIDAD, IUIIE is ),T& (w) M K10
Lu
W
O
LL
cn
Wq
x
z LU w
J cn s;
Oct)
A
..,
r
zI-- a
Cl) c')
N
Qvb < L "' o z
0 c/) w �
GL qr- 0 Q
LLJ Cl� _ � Q O
U) co �-
STORE NUMBER
■ ■ ■
ISSUE
'A' -ISSUE LL, DID, PERMIT
DATE 3/28/14
W -ISSUE TENANT CHANGE
DATE 5/12/14
'C'- -ISSUE BUILDING COMMENT
DATE 5/14/14
'D' -ISSUE
DATE
'E' -ISSUE
DATE
SHEET TITLE
EX. CONDITIONS /
SELECTIVE DEMO.
FLOOR PLAN
SCALE
1/4' =1' -0'
SHEET NUMBER
A0.1
mmwm�_