14-403-019it o KEY NOTES 1. EXISTING JUNCTION BOX AT STOREFRONT FOR CONNECTION TO NEW TENANT SIGNAGE. SIGN SHALL REMAIN CONNECT TO EXISTING CONTROL SYSTEM. 2. FURNISH AND INSTALL JUNCTION BOX FOR CONNECTION OF ILLUMINATED SIGN BOXES MOUNTED ABOVE THE CEILING. PROVIDE AN 8r -0" WHIP TO ROUTE THROUGH NEW LIGHTING CONTROL PANEL AS REQUIRED. 3. CONNECT NEW SOFFIT LIGHTING INTO EXISTING SOFFIT LIGHTING AND ASSIGN TO CIRCUIT AS INDICATED. 4. CONNECT NEW DISPLAY LIGHTING INTO EXISTING DISPLAY LIGHTING AND ASSIGN TO CIRCUIT AS INDICATED. 5. CONNECT NEW GENERAL LIGHTING INTO EXISTING GENERAL LIGHTTNG AND ASSIGN TO CIRCUIT AS INDICATED. 6. ROUTE NEW ACCENT LIGHTING THROUGH EXISTING CONTROLS AS REQUIRED. COORDINATE IN FIELD. 7. NEW SWITCH BANK FOR CONTROL OF SALES AND FITTING ROOM LIGHTING. SEE SWITCHING DETAIL ON THIS SHEET AND LIGHTING CONTROL PANEL DETAIL ON SHEET E4.0 FOR ADDITIONAL INFORMATION. S. EXISTING TOILET EXHAUST FAN TO REMAIN. 9. CONNECT NEW TOILET ROOM EMERGENCY LIGHT INTO EXISTING EMERGENCY CIRCUIT AS REQUIRED. 10. EXISTING 277/480 VOLT, 3 PHASE, 4 WIRE, 125 AMP PANEL WITH 100 AMP MAIN BREAKER TO REMAIN. (DESIGNATED "Ark 11. EXISTING 30 KVA TRANSFORMER ON THE FLOOR TO REMAIN. 12. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 225 AMP PANEL WITH 100 AMP MAIN BREAKER TO REMAIN. (DESIGNATED "B ") 13. NEW LIGHTING CONTROL PANEL, SUPPLIED BY OWNER AND INSTALLED BY G.C. SEE RISER DIAGRAM SHEET E3.0 AND LIGHTING CONTROL PANEL DETAIL ON SHEET E4.0 FOR ADDITIONAL INFORMATION. 14. DEVICES IN THIS AREA SHALL BE AS FOLLOWS (WHERE SHOWN AND APPLICABLE): SINGLE POLE SWITCHES: HUBBELL, MODEL #HBL -1221. - LIGHTING CONTROL SWITCHES: LINE VOLTAGE LIGHTED TOGGLE. - COVERPLATES: HUBBELL, COLOR WHITE. EX E4 EX E4 EX /E4 EX E4 EX /E4 EX /E4 EX /GI O EX E4 EX/E41 EX /E4 / / EX /E4' EX /E4 EX /E4 n " n nn " ice- E GI 1 / n / -'19" fit n - - -y g* I r - - - 9.1 r - - - *r 1 I - - --- B" -t_1- - - -r Bri r - B..I r _ _...- -wow 1 I - '�I 1 - B" 1r -' g`1 r - `B"fi1 "B'39 "6"11 "B"1s "B"1s "6"19 "6"19 "6"19 "6"19 "6"19 "9 "21 "6"21 "6"21 "6"21 21 "6.21 "9"23 "9.23 "6.23 "B "23 "6.23 "6"23 "9.25 "9"25 "9.25 "B'25 EX /H 42 - -_ -_- - -_- 11 I► Iwo PENN .9ft MON __ __ _ _ _ _ - -_ - -- -_ - -- - _ _� -_ -- -�- -- -- �- -_ -_ _ _ _ /� /A • / EX /A%EM B" 37 _ EFS7- B r 37 B 37 Bw 37 B' 37 9 37 B" 37 B" 37 B 37 B" 37 9" 37 B" 37 B' 37 EX /A n ow EX /A EX /A EX /A EX /A EX /A EX /A i Q" B" 1 /4/EX /X I" 9.3 O" �w 3 O" B" 1 O" Bw 1 O" B" 1 O" 9" 1 2 / I I " B"3 B"35 A / /,, EX /A EX /A /EM/ EX /A » » .6"371 "6"41 B"38 1�JJ% «6"38 9"38 O B"3 FIXTURE EX /E4 EX /A �1 GI / EX /GI 1 / "B'3s EX /A I EX /A /EM/ EX /A /EM/ 0 SOFFIT) 30 IN 1 d» B" 1 42 3 B" 35 _ _ "$" 35 - - 3" ~X35- 3 3 €4 - -w� Bw 38 A A EX /A /EM/ EX /A • I lljw 11 - 6"-35- ��'- � B" 38 p ri F B" 1" how ft" boo / EX /GI - _ - - - - - - - - - - w-5 -" B" 35 - " Brr 3 E4 1 •" B" 3 •" B" 3 �" B" 38 Ow / FIXTURE "EX /G2" / "B"3� (TYP. FOR 43) "B"13 "8"13 "6"13 "8"13 "6.13 "6.13 "8"13 A I A i 1 9"37 I EX /EM EX A / 1 / EX /A EX/€4 - - - dX/E4 -- - - E3 - �X{E3 - - • I I� I r / � I1 / • ice-- -� -'0 X/H " B' 3 "Er- I I I » 1 1 3 7 14 "B" l l 1 "B" 11 "B' 11 "B" 11 6"40 F I I » D1 /NL I EX /XI B" 8I I 1 I » i B" 35 8"39 13 - - B" 11 40 D2 E A A EX /A EX/A I B. 8 MKI (� I I • • �" 0" "B" 351 II9" 38 I F /A� \ 12 3� DC /B A /EM i 1 "B'3 "B'3 B" 1 B" 1 I EX/�A^ 119" 1\I V w y 40 1 1 "B" 1. 1 l_ Ex /c /c /EM � EX /c II "If 38 F I " B„ 914X /AW B" 35 I \ W. B" 3 40 E4 I \ O A �1 EX /A EX /A EX /A EX /A 9"35 EX /A EX /GI \ \ 10 D2 1 0 0 0 0• ' w "8"33 �- 6"38 "B "33 wryr3 11 "B"3 "B"1 "B"1 B'1 i 0 "B"1 I Q ET 42 EX/ B I tX /A • F I 1 9" 35 1 2 \ \ \ IN. " � 3 40 40 E4 i B" 35EX/ EX /GI " Er1 "6.42 � 1 A A EX /A EX /A 6.41 EX /C EX /C - - E4 "16"27 I • "g,� •wry. _ "9 I r "� EX/ �� EX /GI ID 35 ry In F711 -- - • » ".B"_ 35 ,� _ " 6"35 - "g" 35 � _ __T_3 - - _�35 _ -" E�3 w B" 35 • » 8r 1 " B" 42 \ \ 0 0 Er,3 -4 �- _ - - -- - -- \ O EX/ B I - - - b "8"33 "8"33 O '�B" 11 C,2 C,2 G2 G2 G2 C,2 4 B" 15 9" 15 15 15 B" 15 B" 17 17 17 17 17 B" 17 lu Y1 " B» 9 - 3 - - --E4- E4 - - - ---- -E4- - - - X/E4 _ _ - n�ac/-E4- - - " - - -EX/-E4- _ _ E4 - - - ' - - - 1 " B" 42 "6"11 "9"11 1 9.11j, B "11 °6"11 6.111 "B"11 1 "6.11; "6"11 ' " "B 11 , I � i 33 "6"38 I ` m 33 FLOOR PLAN LIGHTING WORK SCALE 1/4• CONTACTOR #1 CONTACTOR #2 "B"33 •I °1 el II o • • LIGHTING I LIGHTING LIGHTING \-3-GANG LIGHT SWITCH COVERPLATE +46" AFF PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SWITCHING DETAIL, NOT TO SCALE • % .• ••• . . . . . • *so* • • • • • w••• ...•• ... • ; Wei Z G� 2 U uw t�i ca O ° 0 0 0 0 H Mj,pjAI.DA1)E C07TY FIRE DF:PARTW! NT •Uryrrrurry�` �• pEMN�`''e. Y • � •��G E N SF•••• �s� No gi 09c %* F ,r • A • wr• STA E 01: 4a" ; : :DATA••' w : 3/26/14 • w w w • • JOB NO: 14-015 wWWN: STAFF �HEC:KED: CM QD uww W_ • Y Y 1 � � O c$ Fa O c Room= ComMA m (ADDITC(r] 125 a114A1O 14M, AM Ili 11L (00)111 -511/ W W V oc Q O J t- CL W LL co J Z W cn ) Z to to � CV Q �- W a � v, Q W . oom�Q= J = cf) = .9 0 a � I- U ui J W 00 = Q H cn = r• 0 a o F- U-) cn co F-" ffmm� MEN STORE NUMBER tmbodo ISSUE V -ISSUE LL, MD, PERMIT DATE 3/26/14 DATE C'-ISSUE D =� E E' -ISSUE DATE SHEET TITLE FLOOR PLAN LIGHTING WORK SCAI 1/4' -1' -0' SHEET NUMBER E1.0 SCHEDULE LIG HT FIXTURE PE50RIPTION EXI5TIN6 6" RECESSED INCANDESCENT DOWNLI6HT WITH CLEAR ALZAK TRIM. NOTE EM FIXTURES HAVE EMER&ENGY BALLAST AND 010 MIN. BATTERY NEW TO MATCH EXISTING 6" REGE55ED INCANDESCENT DOWNLI&HT WITH CLEAR MFC LI6HTOLIER LI&HTOLIER GATAL06# 72bbHM- b05bGL - 12bbHM- &O56GL LAMP TYPE VOLTAOE (2) 26W GFL (2) 26W GFL 120 120 MOUNTING RECESSED RECESSED GTY 31 -A b -A/r=M 10 -A REMARK5 EXISTING LIGHT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWIN65 V.I.F. NEW FIXTURES TO MATCH EXISTING 5YM MARK O / ' U/A EX /A/EM A ALZAK TRIM. NOTE EM FIXTURES HAVE A /EM EMERGENCY BALLAST AND 010 MIN. BATTERY EXISTIN6 2 X 2 FLUORESCENT WITH 01 CELL PARABOLIC LENS. LIGHTOLIER PLA2&g052U&12O5O (2)F532T8 TL741/6 120 REGE55ED 1 -A/EM 3 EXISTING L16HT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWIN65 V.I.F. EdEX/E EXISTIN6 2 X 4 FLUORESCENT WITH PR15MATIG LENS. NOTE EM FIXTURES HAVE EMEi'RGENGY BALLAST AND 010 MIN. L16HTOLIER XT26V240 -12050 (2)F532Tb TLb41 120 RECESSED 5-C, I -G/EM EXISTIN6 LIGHT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. NOTE REPLACE A;LL PRISMATIC LENS. FIXTURE SPEC FROM ORIGINAL TENANT DRAWINGS V-1 F. O ❑� / C EX /C /EM O D2 BATTERY 24" DRUM FOCAL PENDANT FIXTURE WITH FABRIC COVER T.B.D. L16HTOLIER T.B.D. 5NI3OTb -55 (4) 26W GFL (I) W- F025W78 (1) W- 120 120 PENDANT MOUNT SURFACE MOUNT 2 b TENANT 5UPPLIEDAN15TALLED BY 6.0. SET B.O. FIXTURE @ b -O A.F.F. EXI5TIN6 LIGHT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. FIXTURE SPEC FROM OR161NAL TENANT DRAWINGS V.I.F. EVE3 EXISTIN6 3' (2) LAMP FLUORESCENT STRIP FIXTURE I -1 EX/E4 EXISTIN6 4' (2) LAMP FLUORESCENT STRIP FIXTURE LI&HTOLIER 5N14OTb -55 (I) W- F032WTb (1) H- 120 SURFACE MOUNT 45 EXISTIN6 LIGHT FIXTURES, TO BE GLEANED, REPAIRED, REL.AMPEP. FIXTURE SPEC FROM ORIGINAL TENANT DRAWINGS V.I.F. -� NEW 3' (2) LAMP FLUORESCENT STRIP FIXTURE L16HTOLIER SNI30Tb -5S (- F025WTb U W TLb41 120 SURFACE MOUNT b NEW FIXTURES 70 MATCH EXISTIN6 NEW 4' (2) LAMP FLUORESCENT STRIP FIXTURE RECE55ED METAL HALIDE ACCENT FIXTURE LIC6HTOLIER INDY 5NI4OTb -S5 M525b- 70H -WH (� FO32WTb 70W PAR50L MH 120 120 SURFACE MOUNT RECESSED 13 3 NEW FIXTURES TO MATCH EXISTIN6 TENANT PROVIDED INSTALLED BY O.G. F- -�-- -� E4 F EXISTING STOREFRONT TRACK L16HTIN66 METAL HALIDE WHITE, 51NOLE CIRCUIT .TRACK L16HTOLIER L16HTOLIER b2016 WH 01175 NH GDM35/PAR 30 /M/FL 6000 SERIES TRACK MRI6 -12V 501-4 NFL b000 SERIES TRACK 120 120 SURFACE SURFACE 11 43 EXISTIN6 LIGHT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWIN65 V.I.F. EXI5TIN6 L16HT FIXTURES, TO BE GLEANED, REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWINGS V.I.F. EX /Gj EX /C2 EXI5TIN6 SALES AREA TRACK LIGHTING LOW 1/OLTA6E, SINGLE CIRCUIT TRACK NEW 5ALE-5 AREA TRACK LI6HTIN6 LOW VOLTAGE, SINGLE CIRCUIT TRACK TO MATCH EXISTING LIGHTOLIER 01175 WH MRI6-12V 5OW NFL b000 SERIES TRACK 120 SURFACE b heads Ib' track ADDITIONAL TRACK L16HTIN6 TO MATCH EXISTING. FIXTURE SPEC, FROM ORIGINAL TENANT DRAWINGS V.I.F. EXI5TIN6 LIGHT FIXTURES, TO BE GLEANED, G2 0 EX--H EXI5TIN6 WALL SCONCE FIXTURE VI5TA C63700 /I1=13 -5LA (1) 130TT -27K 120 SURFACE 3 REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWINGS V.I.F. EXI5TIN6 LIGHT FIXTURES, TO BE GLEANED, X EXISTIN6 EXIT 516N WITH W 90 MIN BATTERY BACK -UP DUAL -LITE LXU -RWE INCLUDED WALL 3 REPAIRED, RELAMPED. FIXTURE SPEC FROM ORIGINAL TENANT DRAWINGS V-1-F. SINGL E HEAD REMOTE EMERGENCY WITH E MIN BATTERY BACK-UP NAVILITE NRSQ INCLUDED SURFACE I TENANT PROVIDED INSTALLED BY 6.C,. ADD TO TOILET ROOMS C] REOE55ED 6 EXISTIN6 AUDIO SPEAKERS WIRED BACK TO MANA6ER5 DESK $ $ AUDIO SPEAKERS o KEY NOTES 1. EXISTING JUNCTION BOX AT STOREFRONT FOR CONNECTION TO NEW TENANT SIGNAGE. SIGN SHALL REMAIN CONNECT TO EXISTING CONTROL SYSTEM. 2. FURNISH AND INSTALL JUNCTION BOX FOR CONNECTION OF ILLUMINATED SIGN BOXES MOUNTED ABOVE THE CEILING. PROVIDE AN 8r -0" WHIP TO ROUTE THROUGH NEW LIGHTING CONTROL PANEL AS REQUIRED. 3. CONNECT NEW SOFFIT LIGHTING INTO EXISTING SOFFIT LIGHTING AND ASSIGN TO CIRCUIT AS INDICATED. 4. CONNECT NEW DISPLAY LIGHTING INTO EXISTING DISPLAY LIGHTING AND ASSIGN TO CIRCUIT AS INDICATED. 5. CONNECT NEW GENERAL LIGHTING INTO EXISTING GENERAL LIGHTTNG AND ASSIGN TO CIRCUIT AS INDICATED. 6. ROUTE NEW ACCENT LIGHTING THROUGH EXISTING CONTROLS AS REQUIRED. COORDINATE IN FIELD. 7. NEW SWITCH BANK FOR CONTROL OF SALES AND FITTING ROOM LIGHTING. SEE SWITCHING DETAIL ON THIS SHEET AND LIGHTING CONTROL PANEL DETAIL ON SHEET E4.0 FOR ADDITIONAL INFORMATION. S. EXISTING TOILET EXHAUST FAN TO REMAIN. 9. CONNECT NEW TOILET ROOM EMERGENCY LIGHT INTO EXISTING EMERGENCY CIRCUIT AS REQUIRED. 10. EXISTING 277/480 VOLT, 3 PHASE, 4 WIRE, 125 AMP PANEL WITH 100 AMP MAIN BREAKER TO REMAIN. (DESIGNATED "Ark 11. EXISTING 30 KVA TRANSFORMER ON THE FLOOR TO REMAIN. 12. EXISTING 120/208 VOLT, 3 PHASE, 4 WIRE, 225 AMP PANEL WITH 100 AMP MAIN BREAKER TO REMAIN. (DESIGNATED "B ") 13. NEW LIGHTING CONTROL PANEL, SUPPLIED BY OWNER AND INSTALLED BY G.C. SEE RISER DIAGRAM SHEET E3.0 AND LIGHTING CONTROL PANEL DETAIL ON SHEET E4.0 FOR ADDITIONAL INFORMATION. 14. DEVICES IN THIS AREA SHALL BE AS FOLLOWS (WHERE SHOWN AND APPLICABLE): SINGLE POLE SWITCHES: HUBBELL, MODEL #HBL -1221. - LIGHTING CONTROL SWITCHES: LINE VOLTAGE LIGHTED TOGGLE. - COVERPLATES: HUBBELL, COLOR WHITE. EX E4 EX E4 EX /E4 EX E4 EX /E4 EX /E4 EX /GI O EX E4 EX/E41 EX /E4 / / EX /E4' EX /E4 EX /E4 n " n nn " ice- E GI 1 / n / -'19" fit n - - -y g* I r - - - 9.1 r - - - *r 1 I - - --- B" -t_1- - - -r Bri r - B..I r _ _...- -wow 1 I - '�I 1 - B" 1r -' g`1 r - `B"fi1 "B'39 "6"11 "B"1s "B"1s "6"19 "6"19 "6"19 "6"19 "6"19 "9 "21 "6"21 "6"21 "6"21 21 "6.21 "9"23 "9.23 "6.23 "B "23 "6.23 "6"23 "9.25 "9"25 "9.25 "B'25 EX /H 42 - -_ -_- - -_- 11 I► Iwo PENN .9ft MON __ __ _ _ _ _ - -_ - -- -_ - -- - _ _� -_ -- -�- -- -- �- -_ -_ _ _ _ /� /A • / EX /A%EM B" 37 _ EFS7- B r 37 B 37 Bw 37 B' 37 9 37 B" 37 B" 37 B 37 B" 37 9" 37 B" 37 B' 37 EX /A n ow EX /A EX /A EX /A EX /A EX /A EX /A i Q" B" 1 /4/EX /X I" 9.3 O" �w 3 O" B" 1 O" Bw 1 O" B" 1 O" 9" 1 2 / I I " B"3 B"35 A / /,, EX /A EX /A /EM/ EX /A » » .6"371 "6"41 B"38 1�JJ% «6"38 9"38 O B"3 FIXTURE EX /E4 EX /A �1 GI / EX /GI 1 / "B'3s EX /A I EX /A /EM/ EX /A /EM/ 0 SOFFIT) 30 IN 1 d» B" 1 42 3 B" 35 _ _ "$" 35 - - 3" ~X35- 3 3 €4 - -w� Bw 38 A A EX /A /EM/ EX /A • I lljw 11 - 6"-35- ��'- � B" 38 p ri F B" 1" how ft" boo / EX /GI - _ - - - - - - - - - - w-5 -" B" 35 - " Brr 3 E4 1 •" B" 3 •" B" 3 �" B" 38 Ow / FIXTURE "EX /G2" / "B"3� (TYP. FOR 43) "B"13 "8"13 "6"13 "8"13 "6.13 "6.13 "8"13 A I A i 1 9"37 I EX /EM EX A / 1 / EX /A EX/€4 - - - dX/E4 -- - - E3 - �X{E3 - - • I I� I r / � I1 / • ice-- -� -'0 X/H " B' 3 "Er- I I I » 1 1 3 7 14 "B" l l 1 "B" 11 "B' 11 "B" 11 6"40 F I I » D1 /NL I EX /XI B" 8I I 1 I » i B" 35 8"39 13 - - B" 11 40 D2 E A A EX /A EX/A I B. 8 MKI (� I I • • �" 0" "B" 351 II9" 38 I F /A� \ 12 3� DC /B A /EM i 1 "B'3 "B'3 B" 1 B" 1 I EX/�A^ 119" 1\I V w y 40 1 1 "B" 1. 1 l_ Ex /c /c /EM � EX /c II "If 38 F I " B„ 914X /AW B" 35 I \ W. B" 3 40 E4 I \ O A �1 EX /A EX /A EX /A EX /A 9"35 EX /A EX /GI \ \ 10 D2 1 0 0 0 0• ' w "8"33 �- 6"38 "B "33 wryr3 11 "B"3 "B"1 "B"1 B'1 i 0 "B"1 I Q ET 42 EX/ B I tX /A • F I 1 9" 35 1 2 \ \ \ IN. " � 3 40 40 E4 i B" 35EX/ EX /GI " Er1 "6.42 � 1 A A EX /A EX /A 6.41 EX /C EX /C - - E4 "16"27 I • "g,� •wry. _ "9 I r "� EX/ �� EX /GI ID 35 ry In F711 -- - • » ".B"_ 35 ,� _ " 6"35 - "g" 35 � _ __T_3 - - _�35 _ -" E�3 w B" 35 • » 8r 1 " B" 42 \ \ 0 0 Er,3 -4 �- _ - - -- - -- \ O EX/ B I - - - b "8"33 "8"33 O '�B" 11 C,2 C,2 G2 G2 G2 C,2 4 B" 15 9" 15 15 15 B" 15 B" 17 17 17 17 17 B" 17 lu Y1 " B» 9 - 3 - - --E4- E4 - - - ---- -E4- - - - X/E4 _ _ - n�ac/-E4- - - " - - -EX/-E4- _ _ E4 - - - ' - - - 1 " B" 42 "6"11 "9"11 1 9.11j, B "11 °6"11 6.111 "B"11 1 "6.11; "6"11 ' " "B 11 , I � i 33 "6"38 I ` m 33 FLOOR PLAN LIGHTING WORK SCALE 1/4• CONTACTOR #1 CONTACTOR #2 "B"33 •I °1 el II o • • LIGHTING I LIGHTING LIGHTING \-3-GANG LIGHT SWITCH COVERPLATE +46" AFF PROVIDE PERMANENT, TYPED LABELS AS SHOWN. SWITCHING DETAIL, NOT TO SCALE • % .• ••• . . . . . • *so* • • • • • w••• ...•• ... • ; Wei Z G� 2 U uw t�i ca O ° 0 0 0 0 H Mj,pjAI.DA1)E C07TY FIRE DF:PARTW! NT •Uryrrrurry�` �• pEMN�`''e. Y • � •��G E N SF•••• �s� No gi 09c %* F ,r • A • wr• STA E 01: 4a" ; : :DATA••' w : 3/26/14 • w w w • • JOB NO: 14-015 wWWN: STAFF �HEC:KED: CM QD uww W_ • Y Y 1 � � O c$ Fa O c Room= ComMA m (ADDITC(r] 125 a114A1O 14M, AM Ili 11L (00)111 -511/ W W V oc Q O J t- CL W LL co J Z W cn ) Z to to � CV Q �- W a � v, Q W . oom�Q= J = cf) = .9 0 a � I- U ui J W 00 = Q H cn = r• 0 a o F- U-) cn co F-" ffmm� MEN STORE NUMBER tmbodo ISSUE V -ISSUE LL, MD, PERMIT DATE 3/26/14 DATE C'-ISSUE D =� E E' -ISSUE DATE SHEET TITLE FLOOR PLAN LIGHTING WORK SCAI 1/4' -1' -0' SHEET NUMBER E1.0