Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
14-403-004
NO GENERAL DEMOLITION NOTES I. THE SECTION IS INCLUDED FOR GENERAL CONTRACTOR 8. G -G. 15 TO ERECT CONSTRUCTION BARRICADES AND A) REFERENCE WORK TO E39 PERFORMED BY GENERAL DEBRI5/DUCT SCREENS PER LANDLORD'S EXISTING TENANT DEMISING HALL: (IHS R,4TED) A•) EXISTING 6" X 20 GA METAL STUDS a I6" O.G. J" TYP "X" GYP BD. EACH SIDE FULL HEIGHT TO UNDERSIDE OF 2ND FLOOR DECK. UL DESIGN U-465 CONTRACTOR (G.C) APPLIED AS NEEDED TO STORE. SPECIFICATIONS. CONTACT LANDLORD'S FIELD 2. G.G. IS TO REMOVE ALL EXISTING LEASEHOLD REPRESENTATIVE PRIOR TO THE COMMENCEMENT OF ALL IMPROVEMENTS AS REQUIRED TO ACHIEVE SCOPE OF DEMOLITION WORK. , WORK NOTES. DEMOLITION INCLUDES, BUT IS NOT LIMITED 9. WHERE APPLICABLE, 6.0. 15 TO COORDINATE THE yp� TO THE REMOVAL OF ALL EXISTING INTERIOR WALLS, REMOVAL, DISPOSAL, AND/OR RETURN OF ALL EXISTING PARTITIONS, CEILINGS, FLOOR COVERINGS, PLATFORMS, SECURITY SY5TEM5 WITH LANDLORD'S CONSTRUCTION DISPLAY SHOW WINDOWS, CABINETS, ETG. UNLESS NOTED MANAGER PRIOR TO ITS REMOVAL. FAILURE TO DO SUCH OTHERWISE. DEMOLITION ALSO INCLUDES THE REMOVAL COORDINATION HILL RESULT IN G.C.'S MONETARY FINE IN OF ALL EXISTING ELECTRICAL, MECHANICAL AND THE EQUIVALENCE OF THE 005T REPLACEMENT VALUE OF PLUMBING FIXTURES AND EQUIPMENT UNLE55 NOTED ON THE EXISTING SECURITY SYSTEM. MECHANICAL AND ELECTRICAL DRAWINGS. 10 -6.0. 15 TO NOTIFY TENANT IMMEDIATELY OF ANY SEVERE 5. ALL ABANDONED ELECTRICAL/TELEPHONE CONDUIT, DISCREPANCIES OR IRREGULARITIES DISCOVERED PLUMBING LINES, DRAIN LINES, AND MECHANICAL DURING DEMOLITION WHIGH MIGHT AFFECT THE CURRENT DUCTWORK AS THE RESULT OF DEMOLITION SHALL BE STORE DESIGN. G.G. IS TO PAY SPECIAL ATTENTION TO REMOVED. AVAILABLE HEIGHT FOR INTENDED CEILING ELEVATION, 4. 6.0. 15 TO COORDINATE THE P15GONNECTION AND MECHANICAL DUCTWORK AND RECESSED LIGHTING. CAPPING OF ANY UTILITIES WITH LANDLORD'S FIELD II G.G. IS TO OUT ALL NECESSARY OPEMIN65 FOR ANY REPRESENTATIVE. REQUIRED PURPOSE AND REPAIR, WHERE NECESSARY. 5• IN ORDER TO CAUSE THE LEAST AMOUNT OF AFTER GUTTING IN .50 FAR AS POSSIBLE ALL INCONVENIENCE, G.G. IS TO COORDINATE WITH ALL PROTRUSIONS, MARKS, CRACKS, OR OTHER EVIDENCE OF ADJACENT SPACES A CONVENIENT TIME TO PERFORM DAMAGED, DEFICIENT OR UNSAFE CONDITION, ANY PARTS DEMOLITION WORK. 6.0. 15 TO PROVIDE AND INSTALL ALL WHIGH ARE SPLIT, CRACKED, 5PALLED, CHIPPED, BROKEN, TEMPORARY PROTECTED MEANS OF EGRESS. MISSING, OUT OF LINE OR ADJUSTMENT MECHANICALLY OR TEMPORARY LIGHTING, AND ALL SAFETY DEVICES IN STRUCTURALLY UNSAFE OR UNSOUND, BENT, TORN, OR ACCORDANCE WITH ALL STATE AND LOCAL CODES AND OTHERWISE DEFICIENT OR INJURED IN ANY MANNER LANDLORD REQUIREMENTS. SHALL BE REMOVED, REPLACED, REPAIRED OR RESTORED SATISFACTORILY AS DIRECTED BY TENANT'S 6. G.G. IS RESPONSIBLE FOR PATCHING AND /OR REPAIRING CONSTRUCTION MANAGER. EXISTING FLOOR SLAB, DEMISIN& WALLS, AND ROOF DECK AFTER COMPLETION OF ALL DEMOLITION AND 12.6-G. 15 RESPONSIBLE FOR REMOVING ALL DEMOLISHED PRIOR TO THE COMMENCEMENT OF NEW CONSTRUCTION. ITEMS, DEBRIS, ETG., FROM SITE. G.G. 15 RESPONSIBLE G.G. 15 TO COORDINATE WITH LANDLORD FOR PROPERLY DISPOSING OF ALL ITEMS ACCORDING RESPONSIBILITY IN PERFORMING ANY AND ALL ROOF TO ANY APPLICABLE LOCAL OR STATE ORDINANCES. WORK. G.G. 15 TO PATCH, REPAIR AND LEVEL EXISTING FLOOR SLAB AND INFORM TENANT OF ALL SEVERE IRREGULARITIES IN EXISTING SLAB IMMEDIATELY. -1. G.G. IS TO EXERCISE EXTREME CARE DURING DEMOLITION 50 AS NOT TO DAMAGE OR DISRUPT ANY UTILITIES OR SPRINKLER LINES WHICH MIGHT PASS THROUGH THIS SPACE TO SERVICE OTHER MALL SPACES OR OTHER TENANTS. L.L. HILL BEAR SOLE RESPONSIBILITY OF ANY SUCH D15RUPTION OR DAMAGE. WALL TYPE SCHEDULE: EXISTING SYM DE5CRIPTION A) A) INTERIOR CONCRETE COLUMNS: A) EXISTING TENANT DEMISING HALL: (IHS R,4TED) A•) EXISTING 6" X 20 GA METAL STUDS a I6" O.G. J" TYP "X" GYP BD. EACH SIDE FULL HEIGHT TO UNDERSIDE OF 2ND FLOOR DECK. UL DESIGN U-465 A) A) EXISTING INTERIOR PARTITIONS TO REMAIN - - A) A•) INTERIOR PARTITION OR ELEMENT TO BE REMOVED EXISTING CONDITIONS / SELECTIVE DEMOLITION EX. STOREFRONT EX. TOILET ROOM: 1W 1M EXISTING 5TOREFORNT ENTRY AND DISPLAY .WINDOWS TO REMAIN. 18 EXISTING TOILET ROOM TO REMAIN. TEMPORARILY REMOVE ALL EXISTING FIXTURES EX. SALES AREA: 100 AND ACCESSORIES FOR REPLACEMENT OF FINISHES. 2❑ FIELD VERIFY AND REMOVE ANY ABANDONED TENANT FLOOR FIXTURES. 19 REMOVE EXISTING SHEET VINYL TO BE REPLACED WITH NEW. REMOVE EXISTING GASH DESK, ALL ELECTRICAL, TEL AND DATA LINES TO BE REMOVED EX. STOCK AREA: 101 BACK TO POINT OF SERVICE. OUT CONDUITS BELOW FLOOR AND PATCH AND REPAIR FLOOR. ® REMOVE EXISTING TENANT FIXTURES, 5HELVIN5, ACCESSORIES, AND WALL STANDARDS 4� REMOVE FREE STANDING MERCHANDISE DISPLAYS BOLTED TO FLOOR. V.I.F. EXTENT OF ABANDONED ITEMS. 5© EXISTING RECESSED WALL STANDARDS TO REMAIN, UNLESS OTHERWISE NOTED. 21 LOCATION OF EXISTING ELECTRICAL, AND TELEPHONE EQUIPMENT. 'EXISTING CONTACTORS ARE TO BE REMOVED AND REPLACED WITH TENANT LIGHTING CONTROL Q REMOVE EXISTING FACE GAP TRIM AND HORIZONTAL VALANCE ABOVE. TYPICAL THROUGH OUT. REMOVE SECTION OF PARTITIONS WITH RECESSED WALL STANDARDS WHERE SHOWN. ® EXISTING COLUMN ENCLOSURES TO REMAIN. PATCH ND REPAIR AS REQUIREP READY FOR TENANT FINISHES. EXISTING CERAMIC TILE FLOORING TO REMAIN THROUGH OUT. 10 REMOVE ALL WOOD WALL BASE THROUGH OUT. II REMOVE EXISTING SEN50RMATIC PEDISTALS WITH ASSOCIATED LOW - VOLTAGE AND EXPOSED LINE VOLTAGE RECEPTACLE. EX. FITTING ROOMS 101/102 12 REMOVE EXISTING FITTING ROOM DOOR CASING, CURTAINS AND HARDWARE., 13 REMOVE EXISTING FITTING ROOM BENCHES, MILLWORK TRIM ETG. 14 REMOVE (2) FITTING ROOMS COMPLETE. 15 REMOVE 3 -WAY MIRROR 16 EXISTING CERAMIC TILE FLOORING TO REMAIN THROUGH OUT. 17 REMOVE ALL WOOD WALL BASE THROUGrf OUT. PANEL. SEE ELECTRICAL DRAWINGS FOR SCOPE OF WORK. 22 EXISTING DRINKING FOUNTAIN TO 'REMAIN. Z3 EXISTING VGT FLOORING TO REMAIN. FIELD VERIFY HALL BASE CONDITION AND REPLACE AS NEEDED. 24 REMOVE AND REPLACE EXISTING STOCKROOM DOOR. PLAN NORTH INTERIOR MODIFICATIONS ONLY (ANY tXftpj0R N1bDINCATION MAY REQUIRE 4 bbAkt) APPEAIUNCF) — 11 *71 4U•U ••q • U "•••• w�Y• • u • "• do w • v r DATE: . w • y S 12a•/ 14 .... • " . JOB HO:. 14 -015, • DRA4*, I.: STAFF CHECkED: CM """ " •••w coos* 069 "?-. • 711 N. FIELDER RD. ARLINGTON, TX 76012 PH: (817) 635 -5696 FAX: (817) 635 -5699 LICENSE No. AR- 0015586 O <,4DDTE<h 125 MAO AM, SM 105 11L. (SW)113 -5G?8 fOUTFIUl1�?i01R, CT Oi014 F�Jf. (NrOl1i3 -5iiiG i h W Lu OQj , yp� CO Lu LL JZ W t.+ m > Ci) 0 c 1) F- d Cn � ~ N W C /� � Q Vn a Q ono d O O m rt c J =C/)= ..< aU) ~W W COD Q I¢ C!) = I*• O a O STORE NUMBER tmbmdo ISSUE 'A' -ISSUE LL, BID, PERMIT DATE 3/28/14 '6' -ISSUE DATE 'C' -ISSUE DATE 'D' -ISSUE DATE 'E' -ISSUE DATE SHEET TITLE EXISTING COND. DEMOLMON FLOOR PLAN SCALE 1/47 -1' -0' SHEET NUMBER A0.1