13-994-043
DEVICES NOTES 1. COORDINATE ALL LIGHTING FIXTURES WITH MECHANICAL AND PLUMBING TRADES BEFORE ROUGH - IN. PARTICULARLY IN RECESSED TYPES. 2. ALL OUTLETS MOUNTED ON COMMON WALL BETWEEN OR ROOMS SHALL NOT BE MOUNTED BACK TO BACK. THEY SHALL BE STAGGERED TO PREVENT SOUND TRANSMISSION. 3. THERMOSTAT WIRING SHALL BE DONE BY ELECTRICAL CONTRACTOR PER DIAGRAMS BY UNIT MANUFACTURER. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. 4. FOR EXACT LOCATION OF DROP AND LUMINOUS CEILING AREAS, WHERE APPLICABLE, SEE ARCHITECT DRAWINGS. 5. ALL WIRING SHALL BE COPPER THW / THHN, BUT OTHER TYPE OF INSULATION MAY BE USED IF ACCEPTED BY CODE 6. NO RECEPTACLES SHALL BE LOCATED ABOVE KITCHEN SINK. RECEPTACLES IN TOP OF KITCHEN OR BAR COUNTER SHALL BE PROVIDED WITH GFI. 7. ALL DUPLEX RECEPTACLES SHALL BE 125V- 15A -2P -3W GROUNDED. STANDARD GRADE, COLOR CODING. RECEPTACLES SHALL BE MANUFACTURED BY SLATE DECORATOR SERIES OF COLOR SELECTED BY ARCHITECT. 8. ALL CONDUITS SHALL BE CONCEALED IN CEILING, WALL OR FLOOR. 9. ALL RECEPTACLES SHALL BE WIRED IN ACCORDANCE WITH N.E.C. TO ENSURE CORRECT POLARITY. 10. VERIFY EXACT LOCATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN BEFORE ROUGHING -IN. 11. ALL DUPLEX RECEPTACLES SHALL BE INSTALLED IN VERTICAL POSITION AT + 18" A.F.G. MINIMUM. 12. ALL DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH LATEST A.D.A. STANDARDS. 13. ALL ELECTRICAL WIRING IN CEILING PLENUMS SHALL BE IN ACCORDANCE WITH F.B.C. 2001 AND N.E.C. ART 300 -22. SEE A/C AND ARCHITECTURAL PLANS FOR EXACT AREAS. 14. PROVIDE FIRE STOPS IF ALL ELECTRICAL CONDUITS CROSSING FIRE RATED CEILING AND /OR WALLS. CONSULT WITH ARCHITECT BEFORE PROCEEDING WITH ANY PENETRATION THROUGH WALL AND CEILING. REMOVAL AND RELOCATION NOTES 1) THE NATURE OF THIS CONTRACT INVOLVES THE REMODELING OF EXISTING FACILITIES, AND THE CONTRACTOR SHALL MAKE FIELD VISITS PRIOR TO BID AND BECOME FAMILIAR WITH THE SCOPE OF WORK INVOLVED IN THIS JOB. EXTRAS SHALL NOT BE ALLOWED FOR FAILURE ON THE CONTRACTOR'S PART TO COMPLY WITH THIS REQUIREMENT. 2) WHERE ELECTRIC FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC., ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS THE OPERATION OF ANY EQUIPMENT, FIXTURE, RECEPTACLES, ETC., THAT IS TO REMAIN (INCLUDING ITEMS THAT ARE NOT SHOWN IN THE DRAWINGS BUT ARE PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RECIRCUIT THEM, (INCLUDING BOXES, CONDUITS, WIRES, ETC.) TO RESTORE THEM TO THE ORIGINAL OPERATING CONDITION, ALL AT NO ADDITIONAL COST TO THE OWNER. 3) UN -USED OPENINGS IN BOXES, CABINETS, ETC., WHERE CONDUIT IS REMOVED SHALL BE PLUGGED OR BLANKED OUT B Y APPROVED AP OV D 0 METH S. D 4) ALL EXPOSED CONDUITS NOT REUSED IN THE NEW AND REMODELED WORK, SHALL BE REMOVED. 5) EXISTING CONDUIT RUNS, STUBBING UP THRU FLOORS, IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE- ENERGIZED AND REMOVED, CONDUIT CUT -OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR. THE SAME APPLIES WITH EXISTING CONDUITS THAT ARE STUBBING OUT OF WALLS AND FLOORS. 6) CIRCUIT NUMBERS WHEN SHOWN ARE BASED IN PREVIOUS ELECTRICAL DESIGN FOR THIS AREA AND ARE FOR REFERENCE PURPOSE ONLY. CONTRACTOR SHALL VERIFY IN FIELD AVAILABILITY OF SUCH CIRCUITS AND CONNECT ACCORDINGLY. 7 CONTRACTOR SHALL C CUT, PATCH AND FINISH TO MATCH EXISTING SURFACE, AREAS REQUIRING SELECTIVE DEMOLITION IN ORDER TO INSTALL NEW RACEWAYS AND BOXES. 8) IN SHADED AREAS DESCRIBE AS "NOT WORKING AREAS" LIKE BEDROOM /BATHROOMS THE ELECTRICAL CONTRACTOR SHALL APPLY THE LATEST EDITION OF N.E.C. A) INSTALL SMOKE DETECTORS (AS NESSESARY) & INTERLOCKED W /EXISTING ONES. B) EXISTING RECEPTACLES SHALL BE INSPECTED, REPLACED AND /OR ADD TO COMPLY W /N.E.C- 210 -52, AS NESSESARY. C) EXISTING BATHROOM RECEPTACLES SHALL BE REPLACE BY GFI RECEPTACLES TO COMPLY W /NEC.210- 8 -(a), AS NESSESARY. D) EXISTING EXTERIOR RECEPTACLES SHALL BE REPLACED WITH GFI RECEPTACLES AND WHEATHER PROOF COVER, IF REQUIRED 9) EXISTING ELECTRICAL PANEL WILL BE REMAIN AS SHOWN ON PLAN. FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT /ENGINEERS IF ANY CONFLIC OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. INTERRUPTION OF SERVICE ANY WORK REQUIRED BY THESE DOCUMENTS THAT WILL HAVE AN EFFECT ON NORMAL OPERATION OF THE BUILDING SHALL BE COORDINATED WITH THE BUILDING MANAGEMENT. THIS WORK INCLUDES BUT IS NOT LIMITED TO INTERRUPTION OF POWER, TELEPHONE, COMMUNICATION SYSTEM, AIR CONDITIONING. WORK IN THIS CATEGORY MAY HAVE TO DE PERFORMED OUTSIDE REGULAR WORK HOURS AS COORDINATED WITH BUILDING MANAGEMENT. SCHEDULE TIMES AND DATES WITH THE GENERAL CONTRACTOR AND BUILDING MANAGEMENT AS REQUIRED TO AVOID NORMAL WORKING OPERATION. ELECTRICAL SIMBOL LEGEND 000 LIGHTING FIXTURE TYPE DESIGNATION - SEE SCHEDULE _e RECEPTACLE - SINGLE - 20A, 125V, 3 -WIRE (5 -20R) ® FLUORESCENT FIXTURE - RECESSED ADDITIONAL COST TO THE PROJECT GSPG CONSULTING CORP, DO NOT ACCEPT RESPONSIBILITY. EC SHALL CONDUCT A FIELD INVESTIGATION (SEE ( "FIELD INVESTIGATION NOTE ") RECEPTACLE - DUPLEX - 20A, 125V, 3 -WIRE (5 -20R) 5 WORKING DAYS AFTER COMMENCE DEMOLITION WORK TO NOTIFY THE ENGINEER IF FLUORESCENT FIXTURE - RECESSED - EMERGENCY CORRECTION REQUESTED. RECEPTACLE - DUPLEX - 20A, 125V, 3 -WIRE (5 -20R) ABOVE STD. HEIGHT OR ABOVE MECHANICAL AND PLUMBING PLANS SHALL BE CHECK BY E.C. Al- iV• V V •i • • •r••• r•• 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 "��� RECEPTACLE - SINGLE - 20A, 250V, 3 -WIRE } \W REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT `••r.`•s JUNCTION BOXES - AS REQUIRED OR NOTED G+ REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT o ELECTRICAL PANEL -- REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT 30 �, 3TST SAFETY SWITCH - (3)- POLES, (30)- FRAME, (15) -FUSE, *) COMPLIANCE W /NEC 110 -26(a) & 240.24 TYPE. NO EXEPTIONS. ( -PER MANUFACTURER 29. EMERGENCY BATTERY UNIT FIXTURES SHALL BE AT LEAST 1,400 LUMENS REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT r V t`•�`•` �\ �w REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT 0 CABLE/1V OUTLET, PROVIDE 1/2" E.C. WITH PULL STRING 30. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR . STRAPS OR OTHER APPROVED PIPE SUPPORTS. CODED AS PER NEC. STANDARDS . TO CABLE/TV POINT OF SERVICE 31. PROVIDE J.B. AS REQUIRED BY FIELD CONDITIONS, IN THE EVENT THEY EMERGENCY LIGHT FIXTURE - SURFACE (WALL /CEILING MOUNTED) BATTERY © EXHAUST FAN (SEE AIR DISTRIBUTION SCHEDULE) 32. DUCTS DETECTOR SHALL BE PROVIDED IN EXISTING is NEW AC UNITS (2000 BACK UP CFM OR MORE) AND SHALL BE MONITORED BY FA SYSTEM TO SHUT DOWN NATIONAL ELECTRICAL CODE, ALL APPLICABLE STATE AND LOCAL CODES, AND THE EQUIPMENT IN CASE OF ACTIVATION WITH SOUND k LIGHT SUPERVISORY EMERGENCY /EXIT LIGHT FIXTURE COMBO - SURFACE- BATTERY BACK UP 44 TELEPHONE JACK OUTLET - FLUSH IN WALL PROVIDE 1/2" E.C. PLACE, FA CONTRRCTOR SHALL VERIFIED WORKING CONDITION. IF DEVICE DO NOT WORK PROPERLY HAVE TO BE REPLACE. ADDITIONAL FEE MAY APPLIES. REFER TO WITH PULL STRING TO TELEPHONE POINT OF SERVICE SITE INVESTIGATION AND UNFORESEEN CONDITION NOTES FOR CLARIFICATION. TOGGLE SWITCH - 1 PST, 20A, 120/277V SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A $2 TOGGLE SWITCH - 2PST, 20A, 120/277V ABBREVIATIONS MCB MAIN CIRCUIT BREAKER INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG NUMBERS, ETC. WIRES /CONDUIT, DRY TRANSFORMER REDUCTION WILL NOT BE ACCEPTABLE, UNDER A.F.F. ABOVE FINISHED FLOOR MLO MAIN LUGS ONLY ANY CIRCUMSTANCE IN "AS BUILT" PLANS UNLESS PRIOR APPROVAL BY THE $3 TOGGLE SWITCH -- 3WAY, 20A, 120/277V A.F.G. ABOVE FINISHED GROUND MH METAL HALIDE STRAIGHT RUN EXCEEDS 200 FT. AND APPROVED EXPANSION FITTING WITH 34. ELECTRICAL CONTRACTOR SHALL DISCUSS WITH ENGINEER ANY DISCREPANCY BB BACK BOARD MT. MOUNT FOUND IN SET OF DWG PRIOR TO ROUGH IN. MECHANICAL AND PLUMBING PLANS DEVICES NOTES 1. COORDINATE ALL LIGHTING FIXTURES WITH MECHANICAL AND PLUMBING TRADES BEFORE ROUGH - IN. PARTICULARLY IN RECESSED TYPES. 2. ALL OUTLETS MOUNTED ON COMMON WALL BETWEEN OR ROOMS SHALL NOT BE MOUNTED BACK TO BACK. THEY SHALL BE STAGGERED TO PREVENT SOUND TRANSMISSION. 3. THERMOSTAT WIRING SHALL BE DONE BY ELECTRICAL CONTRACTOR PER DIAGRAMS BY UNIT MANUFACTURER. SEE MECHANICAL DRAWINGS FOR EXACT LOCATION. 4. FOR EXACT LOCATION OF DROP AND LUMINOUS CEILING AREAS, WHERE APPLICABLE, SEE ARCHITECT DRAWINGS. 5. ALL WIRING SHALL BE COPPER THW / THHN, BUT OTHER TYPE OF INSULATION MAY BE USED IF ACCEPTED BY CODE 6. NO RECEPTACLES SHALL BE LOCATED ABOVE KITCHEN SINK. RECEPTACLES IN TOP OF KITCHEN OR BAR COUNTER SHALL BE PROVIDED WITH GFI. 7. ALL DUPLEX RECEPTACLES SHALL BE 125V- 15A -2P -3W GROUNDED. STANDARD GRADE, COLOR CODING. RECEPTACLES SHALL BE MANUFACTURED BY SLATE DECORATOR SERIES OF COLOR SELECTED BY ARCHITECT. 8. ALL CONDUITS SHALL BE CONCEALED IN CEILING, WALL OR FLOOR. 9. ALL RECEPTACLES SHALL BE WIRED IN ACCORDANCE WITH N.E.C. TO ENSURE CORRECT POLARITY. 10. VERIFY EXACT LOCATION OF LIGHTING FIXTURES WITH ARCHITECTURAL REFLECTED CEILING PLAN BEFORE ROUGHING -IN. 11. ALL DUPLEX RECEPTACLES SHALL BE INSTALLED IN VERTICAL POSITION AT + 18" A.F.G. MINIMUM. 12. ALL DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH LATEST A.D.A. STANDARDS. 13. ALL ELECTRICAL WIRING IN CEILING PLENUMS SHALL BE IN ACCORDANCE WITH F.B.C. 2001 AND N.E.C. ART 300 -22. SEE A/C AND ARCHITECTURAL PLANS FOR EXACT AREAS. 14. PROVIDE FIRE STOPS IF ALL ELECTRICAL CONDUITS CROSSING FIRE RATED CEILING AND /OR WALLS. CONSULT WITH ARCHITECT BEFORE PROCEEDING WITH ANY PENETRATION THROUGH WALL AND CEILING. REMOVAL AND RELOCATION NOTES 1) THE NATURE OF THIS CONTRACT INVOLVES THE REMODELING OF EXISTING FACILITIES, AND THE CONTRACTOR SHALL MAKE FIELD VISITS PRIOR TO BID AND BECOME FAMILIAR WITH THE SCOPE OF WORK INVOLVED IN THIS JOB. EXTRAS SHALL NOT BE ALLOWED FOR FAILURE ON THE CONTRACTOR'S PART TO COMPLY WITH THIS REQUIREMENT. 2) WHERE ELECTRIC FIXTURES, SWITCHES, OUTLETS, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC., ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS THE OPERATION OF ANY EQUIPMENT, FIXTURE, RECEPTACLES, ETC., THAT IS TO REMAIN (INCLUDING ITEMS THAT ARE NOT SHOWN IN THE DRAWINGS BUT ARE PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RECIRCUIT THEM, (INCLUDING BOXES, CONDUITS, WIRES, ETC.) TO RESTORE THEM TO THE ORIGINAL OPERATING CONDITION, ALL AT NO ADDITIONAL COST TO THE OWNER. 3) UN -USED OPENINGS IN BOXES, CABINETS, ETC., WHERE CONDUIT IS REMOVED SHALL BE PLUGGED OR BLANKED OUT B Y APPROVED AP OV D 0 METH S. D 4) ALL EXPOSED CONDUITS NOT REUSED IN THE NEW AND REMODELED WORK, SHALL BE REMOVED. 5) EXISTING CONDUIT RUNS, STUBBING UP THRU FLOORS, IN AREAS WHERE WALLS ARE TO BE REMOVED, SHALL HAVE THEIR CONDUCTORS DE- ENERGIZED AND REMOVED, CONDUIT CUT -OFF GROUND FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR. THE SAME APPLIES WITH EXISTING CONDUITS THAT ARE STUBBING OUT OF WALLS AND FLOORS. 6) CIRCUIT NUMBERS WHEN SHOWN ARE BASED IN PREVIOUS ELECTRICAL DESIGN FOR THIS AREA AND ARE FOR REFERENCE PURPOSE ONLY. CONTRACTOR SHALL VERIFY IN FIELD AVAILABILITY OF SUCH CIRCUITS AND CONNECT ACCORDINGLY. 7 CONTRACTOR SHALL C CUT, PATCH AND FINISH TO MATCH EXISTING SURFACE, AREAS REQUIRING SELECTIVE DEMOLITION IN ORDER TO INSTALL NEW RACEWAYS AND BOXES. 8) IN SHADED AREAS DESCRIBE AS "NOT WORKING AREAS" LIKE BEDROOM /BATHROOMS THE ELECTRICAL CONTRACTOR SHALL APPLY THE LATEST EDITION OF N.E.C. A) INSTALL SMOKE DETECTORS (AS NESSESARY) & INTERLOCKED W /EXISTING ONES. B) EXISTING RECEPTACLES SHALL BE INSPECTED, REPLACED AND /OR ADD TO COMPLY W /N.E.C- 210 -52, AS NESSESARY. C) EXISTING BATHROOM RECEPTACLES SHALL BE REPLACE BY GFI RECEPTACLES TO COMPLY W /NEC.210- 8 -(a), AS NESSESARY. D) EXISTING EXTERIOR RECEPTACLES SHALL BE REPLACED WITH GFI RECEPTACLES AND WHEATHER PROOF COVER, IF REQUIRED 9) EXISTING ELECTRICAL PANEL WILL BE REMAIN AS SHOWN ON PLAN. FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE -FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT /ENGINEERS IF ANY CONFLIC OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. INTERRUPTION OF SERVICE ANY WORK REQUIRED BY THESE DOCUMENTS THAT WILL HAVE AN EFFECT ON NORMAL OPERATION OF THE BUILDING SHALL BE COORDINATED WITH THE BUILDING MANAGEMENT. THIS WORK INCLUDES BUT IS NOT LIMITED TO INTERRUPTION OF POWER, TELEPHONE, COMMUNICATION SYSTEM, AIR CONDITIONING. WORK IN THIS CATEGORY MAY HAVE TO DE PERFORMED OUTSIDE REGULAR WORK HOURS AS COORDINATED WITH BUILDING MANAGEMENT. SCHEDULE TIMES AND DATES WITH THE GENERAL CONTRACTOR AND BUILDING MANAGEMENT AS REQUIRED TO AVOID NORMAL WORKING OPERATION. ELECTRICAL SIMBOL LEGEND 000 LIGHTING FIXTURE TYPE DESIGNATION - SEE SCHEDULE _e RECEPTACLE - SINGLE - 20A, 125V, 3 -WIRE (5 -20R) ® FLUORESCENT FIXTURE - RECESSED ADDITIONAL COST TO THE PROJECT GSPG CONSULTING CORP, DO NOT ACCEPT RESPONSIBILITY. EC SHALL CONDUCT A FIELD INVESTIGATION (SEE ( "FIELD INVESTIGATION NOTE ") RECEPTACLE - DUPLEX - 20A, 125V, 3 -WIRE (5 -20R) 5 WORKING DAYS AFTER COMMENCE DEMOLITION WORK TO NOTIFY THE ENGINEER IF FLUORESCENT FIXTURE - RECESSED - EMERGENCY CORRECTION REQUESTED. RECEPTACLE - DUPLEX - 20A, 125V, 3 -WIRE (5 -20R) ABOVE STD. HEIGHT OR ABOVE MECHANICAL AND PLUMBING PLANS SHALL BE CHECK BY E.C. Al- GFI MOUNTED COUNTER. ® FLUORESCENT FIXTURE - SURFACE /PENDANT /RECESSED 27. JUNCTION AND PULL BOXES SHALL BE SECURELY MOUNTED TO THE BUILDING QUAD RECEPTACLE - 20A, 125V, 3 -WIRE (5 -20R) STRUCTURE, ACCESSIBLE ALL THE TIME, WITH SUPPORTING FACILITIES INDEPENDENT FLUORESCENT FIXTURE - SURFACE /RECESSED OF THE CONDUITS ENTERING OR LEAVING THE BOXES. BRACKETS, RODS, HANGERS, RECEPTACLE -- DUPLEX - 20A, 125V, 3 -WIRE (5 -20R) BOLTS OF OTHER SUITABLE SUPPORTING METHOD MAY BE USED. AND SHALL BE EMERGENCY LIGHT GALVANIZED CODE -GAUGE SHEET STEEL, WITH SCREWED ON COVER, NEMA 1, OF HALF CONTROLLED BY A SWITCH SIZES AND SHAPE TO ACCOMMODATE WIRING WITHOUT CROWDING AND TO SUIT FLUORESCENT FIXTURE - STRIP GFI APPROVED WIRING METHOD WHERE AUTORIZED BY N.E.C., LOCAL CODES AND FLUORESCENT FIXTURE - EMERGENCY 28. AIC RATING BRANCH CB IN 480V/277 LOAD CENTER OR PANELBOARDS RECEPTACLE - SINGLE - 20A, 250V, 3 -WIRE } \W REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT D I O I�OJ JUNCTION BOXES - AS REQUIRED OR NOTED G+ REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT o ELECTRICAL PANEL -- REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT 30 �, 3TST SAFETY SWITCH - (3)- POLES, (30)- FRAME, (15) -FUSE, *) COMPLIANCE W /NEC 110 -26(a) & 240.24 TYPE. NO EXEPTIONS. ( -PER MANUFACTURER 29. EMERGENCY BATTERY UNIT FIXTURES SHALL BE AT LEAST 1,400 LUMENS REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT WITH A TEST SWITCH, "LED" ANNUNCIATION AND CONNECTED AHEAD OF SWITCH. ELECTRIC MOTOR AS NOTED �\ �w REFER TO LIGHTING FIXTURES SCHEDULES. PROVIDED BY ARCHITECT 0 CABLE/1V OUTLET, PROVIDE 1/2" E.C. WITH PULL STRING 30. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR . STRAPS OR OTHER APPROVED PIPE SUPPORTS. CODED AS PER NEC. STANDARDS . TO CABLE/TV POINT OF SERVICE 31. PROVIDE J.B. AS REQUIRED BY FIELD CONDITIONS, IN THE EVENT THEY EMERGENCY LIGHT FIXTURE - SURFACE (WALL /CEILING MOUNTED) BATTERY © EXHAUST FAN (SEE AIR DISTRIBUTION SCHEDULE) 32. DUCTS DETECTOR SHALL BE PROVIDED IN EXISTING is NEW AC UNITS (2000 BACK UP CFM OR MORE) AND SHALL BE MONITORED BY FA SYSTEM TO SHUT DOWN NATIONAL ELECTRICAL CODE, ALL APPLICABLE STATE AND LOCAL CODES, AND THE EQUIPMENT IN CASE OF ACTIVATION WITH SOUND k LIGHT SUPERVISORY EMERGENCY /EXIT LIGHT FIXTURE COMBO - SURFACE- BATTERY BACK UP 44 TELEPHONE JACK OUTLET - FLUSH IN WALL PROVIDE 1/2" E.C. PLACE, FA CONTRRCTOR SHALL VERIFIED WORKING CONDITION. IF DEVICE DO NOT WORK PROPERLY HAVE TO BE REPLACE. ADDITIONAL FEE MAY APPLIES. REFER TO WITH PULL STRING TO TELEPHONE POINT OF SERVICE SITE INVESTIGATION AND UNFORESEEN CONDITION NOTES FOR CLARIFICATION. TOGGLE SWITCH - 1 PST, 20A, 120/277V SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A $2 TOGGLE SWITCH - 2PST, 20A, 120/277V ABBREVIATIONS MCB MAIN CIRCUIT BREAKER INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG NUMBERS, ETC. WIRES /CONDUIT, DRY TRANSFORMER REDUCTION WILL NOT BE ACCEPTABLE, UNDER A.F.F. ABOVE FINISHED FLOOR MLO MAIN LUGS ONLY ANY CIRCUMSTANCE IN "AS BUILT" PLANS UNLESS PRIOR APPROVAL BY THE $3 TOGGLE SWITCH -- 3WAY, 20A, 120/277V A.F.G. ABOVE FINISHED GROUND MH METAL HALIDE STRAIGHT RUN EXCEEDS 200 FT. AND APPROVED EXPANSION FITTING WITH 34. ELECTRICAL CONTRACTOR SHALL DISCUSS WITH ENGINEER ANY DISCREPANCY BB BACK BOARD MT. MOUNT FOUND IN SET OF DWG PRIOR TO ROUGH IN. MECHANICAL AND PLUMBING PLANS AMOUNT OF 10% OF EACH SIZE USED $4 TOGGLE SWITCH - 4WAY, 20A, 120/277V C. CONDUIT MTG. HT. MOUNTING HEIGHT A MINIMUM OF 3 FUSES OF EACH SIZE. SET OF DWG SUBMITTED AT 50, 75, 90% FOR PRICING PURPOSE SHALL NOT BE CAB. CABINET N.I.C. NOT IN CONTRACT TAKEN AS FINAL SET OF PLAN. E.0 SHALL HAVE IN THE SITE JOB THE LAST REVISED 11. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN $K TOGGLE SWITCH - KEY OPERATED - 20A, 120/277V C.B. CIRCUIT BREAKER OS OCCUPATIONAL SENSOR WILL BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS 35. ARCHITECT OWNER SHALL PROVIDE INFORMATION ABOUT ALL UTILITY COMPANY ARCHITECT/ OWNER CKT. CIRCUIT PNL. PANEL SERVICE CONNECTION POINT PRIOR COMMENCE TO WORK, ANY CHANGE AND OR sP TOGGLE SWITCH - WITH RED PILOT LIGHT - 20A, 120/277V (E) EXISTING RECEPT. RECEPTACLE VERIFIED IN FIELD PRIOR TO ROUGH IN AND PRIOR TO SUBMIT SHOP DRAWINGS; TEL /CAN ROOM, MAIN COMPUTER ROOM TO SERVICE CONNECTION POINT WILL BE EC. EMPTY CONDUIT SW. SWITCH PROPOSE ONLY IT SHALL RE COORDINATED IN FIELD BY ELECTRICAL CONTRACTOR. EQUIPMENT /DEVICES IN THE PROJECT INCLUDING ALL TYPES PUMPS, MOTOR, AIR $M MANUAL MOTOR RATED SWITCH - WITH THERMAL O.L. E.W.C. ELECTRIC WATER COOLER U.G. UNDER GROUND CAPACITY ETC AND SHALL REFER TO MFG FOR SPECS AND INSTALLATION DETAILS. ACCEPTANCE WILL BE PROVIDED. G.F.I. GROUND FAULT INTERRUPTER U.O.N. UNLESS OTHERWISE NOTED GSPG CONSULTING CORP WILL NOT ACCEPT RESPONSIBILITY FOR ANY CHANGE AFTER $D DIMMER SWITCH - RATING AS NOTED. A.F.C.I. ARC FAULT CIRCUIT INTERRUPTER V.P. VAPOR PROOF EXACT LOCATION OF ALL MOTORS, AC UNITS, LIGHTS FIXTURES, DEDICATED AND 36. WHERE SCOPE OF WORK IS NOT PROPERLY DEFINE, ELECTRICAL CONTRACTOR LTG. LIGHTING W.P. WEATHER PROOF (N3R) SHALL PROVIDE AN ALLOWANCE TO COMPLETE THE WORK IN QUESTION, AS PART OF DISCREPANCY PLEASE CONTACT ENGINEERS FOR CLARIFY. os OCCUPATIONAL SENSOR GROUND GND. X.P. EXPLOSION PROOF NC. NON CONCURRENT LOADS DEVICES ETC SHALL BE MOUNTED AT STANDARD HEIGHTS ACCORDING NFPA -70 0 B 37. FURNITURE T E PRE -WIRED TYPE AS PER OWNERS PURCHASED FURN. (CLASS TO MEET N.E.C.) TC. THRU TIME SWITCH OR PHOTOCELL. ELECTRICAL CONTRACTOR TO PROVIDE ALLOWANCE FOR INSTALLATION OF NOT ALL SYSMBOLS MAY APPLY. (1) ISOLATED GROUND E EXISTING TO REMAIN ELECTRICAL CONTRACTOR SHALL VERIFIED WITH MFG /SUPPLIER OR ARCHITECT F/L DENOTE FAN -LIGHT RATED JB AS PER ER EXISTING TO BE REMOVED EXACT MOUNTED HEIGHT, LOCATION AND CONNECTION DETAILS OF EVERY 314.27 (d), NEC. UNFORESEEN CONDITION NOTE: ALTHOUGH GSPG CONSULTING CORP, AS ENGINEER OF RECORD, HAVE CONDUCTED A GOOD -FAITH INVESTIGATION OF THE FIELD AND ITS CONDITIONS AND BECAUSE OF THE UNKNOWN AND UNFORESEEN CONDITIONS OF THE VARIOUS COMPONENTS THAT ARE SCHEDULED TO BE REMOVED, RELOCATED, EXISTING OR REPLACED AS WELL AS THOSE, ANY D ADDITIONAL REQUIREMENTS THAT MAY BE IMPOSED BY THE AUTHORITY HAVING JURISDICTION (AHJ) AND THERE IS ALWAYS THE POSSIBILITY THAT ADDITIONAL WORK, MATERIAL AND TIME MAY BE REQUIRED. IF SUCH WERE THE CASE, OWNER AND GENERAL CONTRACTOR SHOULD BE AWARE THAT IT MAY REQUIRE FOR ADDITIONAL COMPENSATION TO CIRCUMVENT THOSE ISSUES AND ACCOMPLISH THE WORK. WHERE POSSIBLE; THE GENERAL CONTRACTOR SHALL EXHAUST ALL MEANS NOT TO INCUR ADDITIONAL SERVICES TO PROJECT BY COORDINATING AND ASSESSING THE CONDITION AT HAND, THIS SHALL BE PERFORM WITHOUT BRINGING FINANCIAL STRESS OR EXPENSES TO ITS SUB CONTRACTORS, IN GENERAL. GENERAL CONTRACTOR SHALL ADVISE THE A/E SHOULD SAID CONDITIONS BECOME APPARENT, AND NO FIELD DIRECTIVE OR CORRECTIVE MEASUREMENTS WAS REACHED. IT SHALL BE KNOW THAT WE ARE NOT CONTRACTED TO CORRECT OR ADDRESS EXISTING ITEMS THAT ARE NOT OBVIOUS OR EASILY MISSED DURING INITIAL FIELD INVESTIGATION OR ARE NOT INSTALLED PER CODE, INSTALLED WITHOUT PERMITS, OR ARE SIMPLY NON -CODE COMPLIANCE INSTALLATION PERFORMED BY TENANTS ALIKE. WE BELIEVE THAT THE SPACE, AREA, BUILDING OR SIMILAR SPACES ARE PROVIDED TO THE NEW TENANT FOR LEASE WITHOUT ANY CODE VIOLATIONS AND THAT SHALL BE LAND LORDS RESPONSIBILITY TO ADDRESS THOSE ISSUES ONCE THEY HAVE BEEN IDENTIFIED OR NOTED BY EITHER THE CONSTRUCTION TEAM OR BUILDING OFFICIALS DURING INSPECTIONS. ADDITIONAL FEES /CHARGES DUE TO UNFORESEEN CONDITIONS MAY APPLIES SITE INVESTIGATION NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE: THE BIDDER IS REQUIRED BEFORE SUBMITTING HER /HIS PROPOSAL TO VISIT THE SITE AND FAMILIARIZE HER /HIS WITH THE NATURE AND EXTENT OF THE WORK TO BE PERFORM. ANY DEVIATIONS THAT MAY AFFECT THE WORK TO BE PERFORMED SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT /ENGINEER FOR CONSIDERATIONS. VARIATIONS FROM CONTRACT DOCUMENTS: ROUTING AND OR CONSTRUCTIONS VARIATIONS SHOULD BE ANTICIPATED BY THE ELECTRICAL CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES WHERE APPLICABLE. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER (EXCEPT FOR UNFORESEEN SITUATION DUE TO DESIGN CONDITION; REFER TO UNFORESEEN CONDITION NOTES). THE CONTRACTOR WILL IN NO WAY BE RELIEVED OF HIS OR HER OBLIGATIONS AND RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. SPECIAL CONSIDERATION WILL BE GIVEN TO UNFORESEEN CONDITIONS. LIGHTING FIXTURE SCHEDULE ILLUSTRATION TYPE DESCRIPTION MOUNTING MANUFACTURER No. VOLTS LAMPS / FIXTURE WATTS EA. CATALOG NUMBER REMARKS LIGHTING FIXTURES WILL BE SELECTED BY INTERIOR DESIGNER/ ARCHITECT/ OWNER PRIOR ELECTRICAL ENGINEER APPROVAL SEE RCP FOR EXACT LOCATION OF ALL LIGHTS FIXTURES. REFER TO ARCH DWGS. ELECTRICAL GENERAL AND STANDARD NOTES LEGEND AND SCHEDULES SCALE: NTS GENERAL ELECTRICAL NOTES THIS JOB INVOLVE RENOVATION WORK. EC SHALL MAKE A DEEP SITE JOB INVESTIGATION TO VERIFIED IN FIELD ACTUAL CONDITION VS PLANS SUBMITTED. SITE JOB VISIT IS MANDATORY TO BID THIS PROJECT. WRITTEN REPORT SHALL BE SUBMIT TO THE ENGINEER NO LATER THAT 5 WORKING DAYS. ANY CHANGES /CORRECTION /MODIFICATION DUE TO UNFORESEEN CONDITION /LACK OF INFORMATION OF EQUIPMENT IN PLACE OR ANY OTHER SITUATION THAT IMPLIES ADDITIONAL COST TO THE PROJECT GSPG CONSULTING CORP, DO NOT ACCEPT RESPONSIBILITY. EC SHALL CONDUCT A FIELD INVESTIGATION (SEE ( "FIELD INVESTIGATION NOTE ") AND CONTACT THE ENGINEERS IMMEDIATELY PRIOR TO COMMENCE TO WORK, EC /GC HAVE 5 WORKING DAYS AFTER COMMENCE DEMOLITION WORK TO NOTIFY THE ENGINEER IF ANY DISCREPANCY IS FOUND IN SET OF DWGS, AFTER THAT GSPG CONSULTING WILL CONSIDER THE PLANS ACCURACY ACCEPTABLE AND ADDITIONAL FEES MAY APPLIES TO ANY CORRECTION REQUESTED. F MECHANICAL AND PLUMBING PLANS SHALL BE CHECK BY E.C. Al- ALSO SET OF DWGS SUBMITTED AT 50, 75, 90% FOR PRICING PURPOSE SHALL NOT BE TAKEN AS FINAL. E.0 SHALL HAVE IN THE SITE JOB THE LAST REVISED AND APPROVED SET OF PLANS, WITH NO EXEPTION „ 1 . ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 27. JUNCTION AND PULL BOXES SHALL BE SECURELY MOUNTED TO THE BUILDING STRUCTURE, ACCESSIBLE ALL THE TIME, WITH SUPPORTING FACILITIES INDEPENDENT 2. ALL WIRING TO RUN EXPOSED, CONCEALED IN MASONRY WALLS OR CONCRETE OF THE CONDUITS ENTERING OR LEAVING THE BOXES. BRACKETS, RODS, HANGERS, SLABS, BENEATH SLABS OF GRADE OR RUN UNDERGROUND SHALL BE IN RIGID BOLTS OF OTHER SUITABLE SUPPORTING METHOD MAY BE USED. AND SHALL BE GALVANIZED STEEL CONDUIT. OR PVC SCHEDULE 50 IF EXPOSED, OR SCHEDULE GALVANIZED CODE -GAUGE SHEET STEEL, WITH SCREWED ON COVER, NEMA 1, OF 40 IN ALL OTHER SITUATIONS, GALVANIZED STEEL CONDUIT. ELECTRIC METALLIC SIZES AND SHAPE TO ACCOMMODATE WIRING WITHOUT CROWDING AND TO SUIT TUBING EMT, ELECTRIC NON METALLIC TUBING ENT, MC CABLE OR ANY OTHER (EMT), (ENT), LOCATION. APPROVED WIRING METHOD WHERE AUTORIZED BY N.E.C., LOCAL CODES AND ORDENANCES AND LOCAL AUTHORITIES MAY BE CONCEALED IN INTERIOR HOLLOW 28. AIC RATING BRANCH CB IN 480V/277 LOAD CENTER OR PANELBOARDS WALLS AND ABOVE SUSPENDED CEILINGS. SHALL BE 14,000A MIN and 208V/120 LOAD CENTER OR PANELBOARDS SHALL BE 1 MIN, AS PER CODE REQUIREMENTS. 3 . ALL WIRES SHALL BE COPPER UNLESS SPECIFICALLY OTHERWISE INDICATED FOR CB IN KAIC REFER TO PANELS SCHEDULES. MCB ON THE DRAWINGS. ALL INSULATION SHALL BE TYPE "THW ". OR "THHN/THWN ". 28.1. ALL EXTERIOR DISCONNECT SWITCHES (DS). SHALL BE IN NEMA 3R 3A. ALL GROUND WIRES, SHALL BE COOPER. ALUMINUM WIRES FOR GROUND ENCLOSURE RATED, FUSE, SIZED AS PER EQUIPMENT NAMEPLATE AND IN WILL NOT BE ACCEPTED. COMPLIANCE W /NEC 110 -26(a) & 240.24 TYPE. NO EXEPTIONS. 29. EMERGENCY BATTERY UNIT FIXTURES SHALL BE AT LEAST 1,400 LUMENS 4 . BOXES SHALL BE PROVIDED FOR ALL OUTLETS. IN GENERAL THESE BOXES SHALL WITH A TEST SWITCH, "LED" ANNUNCIATION AND CONNECTED AHEAD OF SWITCH. BE STAMPED OR PRESSED SHEET METAL. BOXES IN HAZARDOUS AREAS SHALL BE WHERE APPLICABLE. APPROVED FOR THE CONDITIONS INDICATED. 5 ALL CONDUITS SHALL BE SECURELY FASTENED TO THE BUILDING WITH PIPE 30. ALL RACEWAYS ROUTED, INSULATED CONDUCTORS SYSTEM SHALL BE COLOR . STRAPS OR OTHER APPROVED PIPE SUPPORTS. CODED AS PER NEC. STANDARDS . 6 MANUFACTURER'S NAMES AND CATALOG NUMBERS ARE USED TO DEFINE 31. PROVIDE J.B. AS REQUIRED BY FIELD CONDITIONS, IN THE EVENT THEY . THE TYPE AND QUALITY OF EQUIPMENT AND MATERIAL. EQUAL ITEMS OF OTHER ARE NOT SHOWN ON PLANS MANUFACTURERS ARE ACCEPTABLE WITH THE APPROVAL OF THE ENGINEER. 32. DUCTS DETECTOR SHALL BE PROVIDED IN EXISTING is NEW AC UNITS (2000 7 . ALL WORK SHALL BE DONE IN FULL ACCORDANCE WITH ALL CHAPTERS OF THE CFM OR MORE) AND SHALL BE MONITORED BY FA SYSTEM TO SHUT DOWN NATIONAL ELECTRICAL CODE, ALL APPLICABLE STATE AND LOCAL CODES, AND THE EQUIPMENT IN CASE OF ACTIVATION WITH SOUND k LIGHT SUPERVISORY LOCAL UTILITY CO. REQUIREMENTS. COMPLY W /F.B.C. 2010 do N.E.C. LATEST SIGNAL. IN CASES OF INTERIOR RENOVATION, WHERE EXISTING DEVICES IN EDITION. PLACE, FA CONTRRCTOR SHALL VERIFIED WORKING CONDITION. IF DEVICE DO NOT WORK PROPERLY HAVE TO BE REPLACE. ADDITIONAL FEE MAY APPLIES. REFER TO 8 . AS SOON AS PRACTICABLE, AND WITHIN 30 DAYS AFTER THE AWARD OF THE SITE INVESTIGATION AND UNFORESEEN CONDITION NOTES FOR CLARIFICATION. CONTRACT, AND BEFORE ANY MATERIALS OR EQUIPMENT ARE RELEASED FOR SHIPMENT, THE CONTRACTOR SHALL SUBMIT TO THE ENGINEER FOR APPROVAL A 33. WHEN REFERRING PANELBOARDS /LOAD CENTER RATED AMPACITY IT MEANS COMPLETE LIST OF MATERIALS AND EQUIPMENT PROPOSES TO FURNISH AND MINIMUM VALUES ACCEPTABLE. SERVICE WIRES /CONDUIT SIZE, BRANCH INSTALL, GIVING MANUFACTURER'S NAMES. TRADE NAMES, CATALOG NUMBERS, ETC. WIRES /CONDUIT, DRY TRANSFORMER REDUCTION WILL NOT BE ACCEPTABLE, UNDER SEVEN COPIES SHALL BE FURNISHED. ANY CIRCUMSTANCE IN "AS BUILT" PLANS UNLESS PRIOR APPROVAL BY THE ENGINEER. 9 . WHERE A CONDUIT PASSES THROUGH A BUILDING EXPANSION JOINT OR A STRAIGHT RUN EXCEEDS 200 FT. AND APPROVED EXPANSION FITTING WITH 34. ELECTRICAL CONTRACTOR SHALL DISCUSS WITH ENGINEER ANY DISCREPANCY BONDING JUMPER SHALL BE INSTALLED. REPRESENTATIVE SPARE FUSES IN THE FOUND IN SET OF DWG PRIOR TO ROUGH IN. MECHANICAL AND PLUMBING PLANS AMOUNT OF 10% OF EACH SIZE USED SHALL BE CHECK BY E.C. ANY EQUIPMENT /PUMP /UNIT /CU, ETC. NOT SHOWN ON 10. WHERE FUSIBLE EQUIPMENT IS SPECIFIED, DELIVER TO THE OWNERS WITH ELECTRICAL PLANS E.C. SHALL CONTACT ENGINEER INMIDIATELLY FOR CORRECTIONS. A MINIMUM OF 3 FUSES OF EACH SIZE. SET OF DWG SUBMITTED AT 50, 75, 90% FOR PRICING PURPOSE SHALL NOT BE TAKEN AS FINAL SET OF PLAN. E.0 SHALL HAVE IN THE SITE JOB THE LAST REVISED 11. THE CONTRACTOR SHALL VISIT THE SITE BEFORE SUBMITTING HIS BID IN AND APPROVED SET OF PLANS, WITH NO EXEMPTION ORDER THAT HE MAY BECOME AWARE OF EXISTING CONDITIONS, NO ALLOWANCES WILL BE MADE FOR ANY EXISTING CONDITION OF WHICH THIS CONTRACTOR WAS 35. ARCHITECT OWNER SHALL PROVIDE INFORMATION ABOUT ALL UTILITY COMPANY ARCHITECT/ OWNER AWARE. SERVICE CONNECTION POINT PRIOR COMMENCE TO WORK, ANY CHANGE AND OR OMISSION WOULD IMPLIED CHANGES IN PLANS AFFECTING TIMING SCHEDULE 12. IN FACILITIES THAT INVOLVE NEW OR RENOVATION WORK, E.C. SHALL /BUDGET, ETC. UNDERGROUND CONDUIT LAYOUT FROM MAIN ELECTRICAL ROOM, MAIN VERIFIED IN FIELD PRIOR TO ROUGH IN AND PRIOR TO SUBMIT SHOP DRAWINGS; TEL /CAN ROOM, MAIN COMPUTER ROOM TO SERVICE CONNECTION POINT WILL BE THE VOLTAGE /PHASE /AMPACITY /NUMBER OF CONNECTION POINTS OF ALL PROPOSE ONLY IT SHALL RE COORDINATED IN FIELD BY ELECTRICAL CONTRACTOR. EQUIPMENT /DEVICES IN THE PROJECT INCLUDING ALL TYPES PUMPS, MOTOR, AIR SIZED AND AMOUNT OF CONDUITS FOR TEL /CAN AND COMPUTER SYSTEM SHALL BE CONDITION UNITS, ELEVATORS, GENERATOR SPECIFICATION VOLTAGE, AMPACITY, SPECIFIED PRIOR TO COMMENCE TO WORK, IF NOT, REGULAR AND STANDARD CAPACITY ETC AND SHALL REFER TO MFG FOR SPECS AND INSTALLATION DETAILS. ACCEPTANCE WILL BE PROVIDED. EC SHALL CONTACT MFG /ENGINEER ANY DISCREPANCY. GSPG CONSULTING CORP WILL NOT ACCEPT RESPONSIBILITY FOR ANY CHANGE AFTER THAT AND WILL REQUIRED ADDITIONAL SERVICE FEE IN ORDER TO PROCEED. 13. REFER TO ARCHITECTURAL, CONSULTANTS AND EQUIPMENT LAYOUT PLANS FOR EXACT LOCATION OF ALL MOTORS, AC UNITS, LIGHTS FIXTURES, DEDICATED AND 36. WHERE SCOPE OF WORK IS NOT PROPERLY DEFINE, ELECTRICAL CONTRACTOR GENERAL RECEPTACLES, & OTHER EQUIPMENT BEFORE ROUGHING -IN. ANY SHALL PROVIDE AN ALLOWANCE TO COMPLETE THE WORK IN QUESTION, AS PART OF DISCREPANCY PLEASE CONTACT ENGINEERS FOR CLARIFY. HIS /HER BID. GENERAL USE RECEPTACLES, SWITCHES, WALL MOUNTED EXIT SIGN, ALARM DEVICES ETC SHALL BE MOUNTED AT STANDARD HEIGHTS ACCORDING NFPA -70 0 B 37. FURNITURE T E PRE -WIRED TYPE AS PER OWNERS PURCHASED FURN. NFPA -72, AND OTHER LOCAL CODES AND ORDINANCES AS APPLICABLE UNLESS ELECTRICAL CONTRACTOR TO PROVIDE ALLOWANCE FOR INSTALLATION OF OTHERWISE NOTED. WIRING DEVICES IF NOT PRE -WIRED TYPE FURNITURE IS PURCHASED. ELECTRICAL CONTRACTOR SHALL VERIFIED WITH MFG /SUPPLIER OR ARCHITECT R A ALL CKT BEAKERS THAT FEE D MULTIWIRE BRANCH CIRCUITS SUPPLYING EXACT MOUNTED HEIGHT, LOCATION AND CONNECTION DETAILS OF EVERY PRE- ASSEMBLY FIXED OR FREESTANDING PARTITION FURNITURE IN OFFICE DEDICATED JB /RECPTACLES /CONNECTION POINT. SPACES SHALL BE IN COMPLIANCE WITH ARTICLE 605 do 605.6 FOR SIMULTANEOUS DISCONNECTIONS OF ALL UNGROUNDED CONDUCTORS AT THE 14. ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT NOT FURNISHED PANELBOARD WHERE THE BRANCH CKT ORIGINATES UNDER THIS SECTION BEFORE ROUGHING -IN AND CONTACT ENGINEER IF ANY 38. AVAILABLE FAULT CURRENT AT THE PAD MOUNTED TRANSFORMER DISCREPANCY SECONDARY TERMINALS IS ESTIMATED TO BE 100.000* AMPS 15. LIFT MOTOR SWITCH SHOULD BE LOCATED ON THE GROUND FLOOR. PROVIDE SYMMETRICAL RMS. ALL MAIN BREAKERS SHALL BE SIZED FOR A.I.C.S. 3 WIRES TO SINGLE POLE DBL. THROW SWITCH FOR CHANDELIERS MAINTENANCE IN SERIES WITH DOWNSTREAM BRANCH CIRCUIT BREAKERS AS REQUIRED. PURPOSE. A FULLY RATED SYSTEM IN LIEU OF A SERIES RATED EQUIPMENT MAY BE REQUIRED IF MANUFACTURER CANNOT SUPPLY SERIES RATED 16. THERE CAN NOT BE ANY EQUIPMENT INSTALLED BELOW THE FLOOD CRITERIA EQUIPMENT IN EITHER CASE, ALL EQUIPMENT MUST HAVE PROPER (9' -0 ") ANY MECHANICAL DEVICES SHALL BE AT +9' -1" MINIMUM NO EXCEPT. PROTECTION TO COMPLY WITH AVAILABLE FAULT. RECEPTACLE OUTLETS INSTALLED IN DWELLING UNITS BEDROOM SHALL BE PROTECTED BY ARC. FAULT CIRCUIT INTERUPTER(S). 39. IN COMPLIANCE WITH NEC 110.16 ALL SWITCHBOADS, PANELBOARDS, INDUSTRIAL CONTROL PANELS, METER SOCKET, ETC SHALL BE FIELD MARKET TO 17. CONDUIT RUNS ARE SHOWN SCHEMATICALLY. BUILDING CONDITIONS WARN QUALIFIED PERSONS OF POTENCIAL ELECTRIC ARC FLASH HAZARDS. WILL DETERMINE THE ACTUAL CONDUIT RUN. THE MARKING SHALL BE LOCATED SO AS TO BE CLEARLY VISIBLE TO QUALIFIED PERSON BEFORE EXAMINATION, ADJUSTMENT, SERVICIN, OR MAINTENANCE OF THE 18. THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT NAME PLATE EQUIPMENT. RATING RATING OF THE MOTORS, HEATERS do AC UNITS BEFORE INSTALLATION do INFORM TO THE ELECTRICAL ENGINEER OF ANY DISCREPANCIES. 40. IN FIRE RATED WALL NO BACK TO BACK RECEPTACLES WOULD BE ACEPTABLE, UNLESS 24" DISTANCE OR MORE BETWEEN THEM. 19. WHERE WIRE SIZES ARE INDICATED ON THE PLANS FOR ANY INDIVIDUAL CIRC. THE INDICATED WIRE SIZE SHALL APPLY TO THE COMPLETE CIRCUIT UNLESS 41. WHEN RENOVATION WORK INVOLVE EC SHALL VERIFIED IN FIELD THE OTHERWISE INDICATED. EXISTING CONDITION. ANY CHANGES /CORRECTION /MODIFICATION DUE TO UNFORESEEN CONDITION /LACK OF INFORMATION OF EQUIPMENT IN PLACE OR ANY 20. ALL MOTORS STARTERS FOR FANS, PUMPS, BOILERS, AIR CONDITIONING, ETC.; OTHER SITUATION THAT IMPLIES ADDITIONAL COST TO THE PROJECT GSPG SHALL BE EQUIPPED WITH OVERLOAD PROTECTION IN EACH PHASE LEG. STARTERS CONSULTING CORP, DO NOT ACCEPT RESPONSIBILITY. EC SHALL CONDUCT A FIELD FOR MOTORS RATED AT 50 HP. OR LESS AT 208 v. MAY BE ACROSS THE LINE INVESTIGATION (SEE ( "FIELD INVESTIGATION NOTE ") AND CONTACT THE ENGINEERS TYPE, WHERE APPLICABLE STARTERS FOR LARGER MOTORS SHALL BE REDUCED IMMEDIATELY PRIOR TO COMMENCE TO WORK, IF ANY DISCREPANCY VOLTAGE TYPE PART WINDING, PRIMARY RESISTOR, ETC.) 40. PROVIDE PHENOLIC LABELS IN ALL MAIN SERVICE LOCATION WITH NO 21. IN COMMERCIAL KITCHEN ALWAYS PROVIDE A SHUNT TRIP CIRCUIT BREAKER EXEMPTION TO SHUT OFF ALL THE KITCHEN EQUIPMENT LOCATED UNDER THE HOOD. 41. SECTION 406.11. FOR ALL 15 AND 20A RECEPTACLES IN ALL AREAS 22. ALL CB USED FOR HEATERS, AC & REFRIGERATION UNITS SHALL BE HVAC SPECIFIED IN 210.52 (KITCHEN, FAMILY ROOM, DINNING ROOM, LIVING ROOM, TYPE U.L LISTED. PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION ROOM OR SIMILAR 23. ALL CB USED FOR HIGH INTENSITY DISCHARGE FIXTURES SHALL BE MARKED ROOM OR AREA OF DWELLING UNITS) TO BE LISTED TAMPER RESISTANT M.I.D. AT THE PANEL FOR ALL HID UNSWITCHED LIGHTS CKT. RECEPTACLES. 42. 2011 NEC - 210.12 (ARC -FAULT CIRCUIT PROTECTION). 24. ALL CB USED FOR FLUORESCENT UNSWITHCHED FIXTURES SHALL BE MARKED IN DWELLING UNITS. ALL 120V, SINGLE PHASE, 15 -20 AMPS BRANCH CIRCUITS S.W.B. AT THE PANEL. SUPPLYING OUTLETS INSTALLED IN DWELLING UNIT IN FAMILY ROOMS, DINNING 25. ALL EQUIPMENT FURNISHED WITH CORD, THE CORD SHALL BE INSTALLED WITH ROOM, LIVING ROOMS, PARLORS, LIBRARIES, DENS, SUN ROOMS, RECREATION CORRECT OUTLET PLUG, JACKS, ETC., AS REQUIRED FOR COMPLETE INSTALLATION ROOMS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED OF EQUIPMENT. ALSO WHEN APPLICABLE RECEPTACLES SHALL BE FURNISHED TO BY A LISTED ARC -FAULT CIRCUIT INTERRUPTER, COMBINATION TYPE INSTALLED TO MATCH THE ELECTRICAL EQUIPMENT SERVED BY. PROVIDE PROTECTION OF THE BRANCH CIRCUIT. 26. ALL ELECTRICAL SERVICE EQUIPMENT SHALL BE READILY ACCESSIBLE AND 43. ANY CHANGES TO BID PRICING DUE TO ADDED WORK OR CHANGES DUE TO SHALL HAVE CLEAN AND DRY LOCATION AND BE PROTECTED FROM PHYSICAL DAMAGE. PERMITTING PROCESS /BUILDING DEPARTMENT REVIEW, COMMENTS do COORDINATION ALSO, CLEAN WORKING SPACE SHALL BE PROVIDED AROUND EQUIPMENT AS PER SHALL BE TREATED AS CORRECTED BID PRICE AND NOT AS CHANGE ORDER NOR NEC. 110 -26 BE TREATED AS ERRORS k OMISSIONS FROM THE DESIGN TEAM. 1 1 2 1 3 1 6 1 9 1 10 1 11 12 1 13 1 14 1 15 1 16 1 17 4 f 06 z u • LU IV V V V V t= ` V U V V V= w• O N V VV • � py � >��Y Iwl � m -2 = w �LL e LU mv Y r r t 0, Q� 1 GSPG ,\ C 8 y 440 NW 132nd CT MIAMI, FLORIDA 33112 email: #af #alcaran�afLnat \•la•h 7ff.514.3300 � Fax :3 30 05 5 # #. #7 #1 !/ CertificateR 30290 rieri/a Ra#fstraII,n: 5#754 SEAL ���,���.,,,, . w . N . 5675 Q ; S o TE F R5� Al- „ , 2013 c v? c 0 U 0 W L.L.J V_ J W� r� J U) W < T O U a� 0 A Architect: JORGE EDUARDO GONZALEZ,AIA AR 94751 / ID 5595 / LEED AP Revisions P120928 Pro iect 05/7/2013 Date: Author Drawn Checked E0.0 • • • i I Uz o o� ~ M o� 00 z Z oo F- z L Z J 0 z C7 oz wZ W� rw F-- M z O LLI F- 0 Of CL 00 z� oU_ =5 o " W_ 0 LU a �Cn ©W Q U W O z w CD vi O zO <U) J W LU Of �o C LLI w t= LL of �o �L [� � oz IL LLj < Y o 0 © LU � U o� Zw LL, F- U) z 5� a W S F~ z Zd ww V) F-- Q W oL z LU ua a� Kw _n C �z o� IL I� U o= o wF- �° d Z o° Of W° LL oz � F- 0 X ww 21 >- F_ n zw J d' a� =a. 0 W' zN �r �a �0 i