13-994-035I J ICI I I■ D C i A AIR DISTRIBUTION SCHEDULE SYM USE TYPE N.C. ACCESSORIES MFR & MODEL NO REMARKS "A" SUPPLY SIDEWALL SUPPLY DIFFUSER MAX. 25 O.B.D. TITUS OPEN 40RUAA14 40RUA012 20X12 WEIGHT LBS. XXXX 9 10 11 12 13 � 14 O.B.D. AIR DISTRIBUTION SCHEDULE SYM USE TYPE N.C. ACCESSORIES MFR & MODEL NO REMARKS "A" SUPPLY SIDEWALL SUPPLY DIFFUSER MAX. 25 O.B.D. TITUS OPEN 40RUAA14 40RUA012 20X12 WEIGHT LBS. XXXX 300 350 AREAS B " SUPPLY SQUARE CEILING DIFFUSER "X24" MAX. 25 O.B.D. TITUS KITCHEN AREAS AHU #3,4,5 & 6 MVD 24 AREA SERVED SEE FL PLAN TMS -AA DROP CEILING "RAG" RETURN CEILING DIFFUSER MAX. 25 0.B.D. TITUS AHU #1 do 2 SEE 0/A CAL. SEE 0/A CAL. (48"X24) LL EXTERNAL STATIC PRESS. WG 350FL -S1 1"-0 "L" LOUVER EXTERIOR WALL MAX. 25 - RUSKIN - ELEC. CHAR. V /,Y /ti 460/3/60 MOUNTED INTAKE a cn DUCT ACCESORIES (90 degree ELBOWS ELF6375DXD 125.0 " -" Q_DPLY CEILING DIFFUSER TOTAL SENS. HEAT MBTU /HR _ EXISTING RAH-ROOMS (HARD gENT. AIR TEMP. -F DB /'F WB (HARD CEILING) 80/67 CEILING DIFFUSER -ti-- ® CEILING) NOTES: 1. ALL AIR DISTRIBUTION SHALL BE OF EXTRUDED ALUMINUM CONSTRUCTION. 2. REFER TO PLAN FOR QUANTITY, LOCATION AIR THROW PATTERN AND SIZES. 3. ALL SUPPLY DIFFUSER SHALL BE INSTALL WITH MANUAL VOLUME DAMPERS (MVD) BUILT --IN SPLIT SYSTEM AC UNITS EOUIPMENT SCHEDULE UNIT MFG CARRIER CARRIER • • O 17' ii Y • .r�r CAPACITY (TONS) 10.0 TONS 12.5 TONS �_..- vvVr fW.. Yr • rsr ..-Y ' UNIT MANUFACTURER CARRIER CARRIER CUBIC FEET PER MINUTE MODEL NUMBER 40RUAA14 40RUA012 V WEIGHT LBS. XXXX XXXX `• W REMARKS: REF. PIPING RS /RL VERIFY W MFG -(3/8"-1 -1 8 VERIFY W MFG (1/2"-1-1/8 V f N.., E7I 4 V 1i W = La Y •, W UNIT NUMBER AHU #1 do 2 AHU #3,4,5 & 6 MVD MANUAL VOLUME DAMPER AREA SERVED SEE FL PLAN SEE FL PLAN EXISTING AND RELOCATED REF. TOTAL SUPPLY AIR CFM 4,000 5,000 F.L.D. FULL LOUVER DOOR OUTSIDE AIR CFM SEE 0/A CAL. SEE 0/A CAL. SUPPLY DUCT SECTION LL EXTERNAL STATIC PRESS. WG 1"_0 1"-0 -� MD MANUAL VOLUME DAMPER FAN MOTOR FLA 4.8 4.8 E.F. (SEE AIR DISTRIBUTION SCHEDULE) o: U " ELEC. CHAR. V /,Y /ti 460/3/60 460/3/60 a cn DUCT ACCESORIES (90 degree ELBOWS COOL. COIL CAP. MBTU /HR 125.0 155.6 FLEXIBLE ROUND DUCT - TOTAL SENS. HEAT MBTU /HR 97.80 121.7 I gENT. AIR TEMP. -F DB /'F WB 80/67 80/67 CEILING DIFFUSER -ti-- ® CEILING RETURN GRILLE 3 LINEAR BAR DIFFUSER WITH SUPPLY AIR PLENUM 19 v MODEL NUMBER -- --- z UNIT MTD. ELEC. HEAT CAP. 10 KW 15 KW 2 STEPS OF ELEC. HEAT NO. 2 2 w = ELEC. CHAR. V O 'L 460/3/60 460/3/60 IST c NO PROFE351ONAL ENGINEER MCA 16 28.6 9960 J MOCP 20.0 30.0 460 LEI Date: a z UNIT NUMBER CU #1 k 2 CU 3,4,5 do 6 Drawn / LOCATION SEE FL. PLAN SEE FL. PLAN = Z AMBIENT TEMP. F 95 95 REFRIGERANT TYPE R PURON PURON COMP. FLA / RLA - - ° ELEC. CHAR. V 460/3 60 460/3/60 ° MANUFACTURER CARRIER CARRIER 2-1 MODEL NUMBER 38AUD012 38AUZA14 cIli °o WEIGHT (LBS) AND DIMENSIONS (LXWXH) 499 / 4'- 11.4 "X3' -9.9 "X4'2.4" 499 / 4'- 11.4 "X3' -9.9 "X4'2.4" 0 MCA AMP 18.9 24.9 0 F=- MOCP AMP 25 30 REMARKS EER /NOTES 11.0 11.2 NOTES: 1. PROVIDE ALL AHU'S WITH 7 DAYS PROGRAMMABLE THERMOSTAT. 2. PROVIDE ALL AHU'S WITH BUILT IN DISCONNECT. 3. PROVIDE ALL AHU'S WITH HORIZONTAL AIRFLOW ARRANGEMENTS, POS #1 OR #3 4. AHU #4 COIL COATING FOR ADDITIONAL ENVIROMENTAL PROTECTION. EXISTING HOOD'S INFORMATION PROVIDED ON THIS PLANS, IS AN EXACT REPRODUTION OF FAN INFORMATION TABLE SHOWN ON HARD COPIES SET PROVIDED BY OWNER (SHEET M -6) AIR CONDITIONING LEGEND SYMBOL DESCRIPTION I �- • • O 17' ii Y • .r�r V r BDD �_..- vvVr fW.. Yr • rsr ..-Y ' 0/A OUTSIDE AIR CFM CUBIC FEET PER MINUTE n' EXHAUST FAN E.R. V V 4 ! f V� ` `• W S/A Y y r V V J f V L V f N.., E7I 4 V 1i W = La Y •, W TRANSFER GRILLE "A" AIR DISTRIBUTION (SEE SCHEDULE) MVD MANUAL VOLUME DAMPER MTVD MOTORIZED VOLUME DAMPER EX /RL EXISTING AND RELOCATED REF. REFRIGERANT RTU. ROOFTOP UNIT F.L.D. AIR CONDITIONING LEGEND SYMBOL DESCRIPTION AHU AIR HANDLING UNIT C.D. CEILING DIFFUSER COND. CONDENSATE BDD BACK DRAFT DAMPER 0/A OUTSIDE AIR CFM CUBIC FEET PER MINUTE E.F. EXHAUST FAN E.R. EXHAUST REGISTER R/A RETURN AIR RG RETURN GRILLE S/A SUPPLY AIR SR SIDEWALL REGISTER TG TRANSFER GRILLE "A" AIR DISTRIBUTION (SEE SCHEDULE) MVD MANUAL VOLUME DAMPER MTVD MOTORIZED VOLUME DAMPER EX /RL EXISTING AND RELOCATED REF. REFRIGERANT RTU. ROOFTOP UNIT F.L.D. FULL LOUVER DOOR TO ® THERMOSTAT / HUMIDISTAT ® SUPPLY DUCT SECTION �3 EXHAUST,RETURN,OR OUTSIDE AIR MVD MOTORIZED VOLUME DAMPER -� MD MANUAL VOLUME DAMPER FD FIRE DAMPER W /SUITAILE ACCESS PANEL © ❑© E.F. (SEE AIR DISTRIBUTION SCHEDULE) o: U " AIR DUCT TO BE REMOVED ED= DUCT TRANSITION a cn DUCT ACCESORIES (90 degree ELBOWS 1037 SHALL HAVE TURNING VANES) 1 FLEXIBLE ROUND DUCT - FLEXIBLE ROUND DUCT DOWN TO GRILL TO BE ADJUST VIA SPEED CONTROLLER. I DUCT SMOKE DETECTOR MOUNTED ON SUPPLY SIDE I EF -1 • SIDEWALL SUPPLY DIFFUSER W /DAMPERS ®-�- CEILING DIFFUSER -ti-- ® CEILING RETURN GRILLE 3 LINEAR BAR DIFFUSER WITH SUPPLY AIR PLENUM 19 LINEAR BAR DIFFUSER BLANKED -OFF NOTE: NOT ALL SYMBOLS MAY BE USED. flti LU Y W V V Y �V CFM wz FAN UNIT M O D E u .____ ____._ FAN -RPM VVYi V K VOLT a o Y! `U Y r Y f r f Y •JrJr G U'� ! t,- f 4 oA Architect: SEAL Uj w F- Q _ so ° INLINE BSQ -XXX -X O LU z TAG w J RPM H. P. ij z ^ BLOWER Of TAG . 5675 SP RPM W �3 VOLT FLA z D -30 z LU SEE PLAN FOR LOCATION SF #2 o: U " ° U 3600 (C� SP INLINE a cn O 1037 3/4 1 F -.• . o do G`a - z y; o TO BE ADJUST VIA SPEED CONTROLLER. I z I EF -1 • 0 zo 1.5" 1252 15.000 3 460 19 _ SEE PLAN FOR LOCATION FAN F- EXISTING EXHAUST FAN CFM wz FAN UNIT M O D E u .____ ____._ FAN -RPM LU 0)F- Z VOLT a o WEIGHT (LBS.) a _____ _. oA Architect: SEAL Uj w F- Q _ so ° INLINE BSQ -XXX -X O LU z TAG w SP RPM H. P. ij ty-z FLA BLOWER Of TAG . 5675 SP RPM HP �3 VOLT FLA D -30 z SEE PLAN FOR LOCATION SF #2 o: U " o' • r o 3600 (C� SP FAN t EXISTING EXHAUST FAN CFM wz FAN UNIT M O D E u .____ ____._ FAN -RPM LU 0)F- 0 VOLT a o WEIGHT (LBS.) 0 z� _____ _. oA Architect: SEAL Uj w F- Q _ so � G 1 INLINE BSQ -XXX -X O LU z TAG IX 0 SP RPM H. P. 1 ty-z FLA BLOWER HOUSING TAG . 5675 SP RPM HP �3 VOLT FLA D -30 z� SEE PLAN FOR LOCATION SF #2 GREENHECK o' • r o 3600 (C� SP INLINE a cn 14.2 1037 3/4 1 F -.• . o do G`a - z y; o TO BE ADJUST VIA SPEED CONTROLLER. I ^ I EF -1 • EF --1 zo 1.5" 1252 15.000 3 460 19 oz SEE PLAN FOR LOCATION LL aLLI ATE 2013 w z 2 A4 -92@ so �u� µ w IL 1113 Proiect IST c NO PROFE351ONAL ENGINEER m A4 KSF ** 9960 1.0" 650 5.0 3 460 7.019 Date: a z U, w Drawn / LU Checked = Z ofE2 ;�a 2-1 cIli O 0 F=- U z0 �3 p of O LU ^ 2fLU z 0 �0 LLJo z� "' z rn Q °zo �� V j U) J LU t U .� U r LLI LU W LL ww_ LL w o J w OL LL- L O E < z L EL LLj C 661 0 � W �_U) T F- LU U Q< Z w w � ^ a �z �LU IILw m LU W z FAN t EXISTING EXHAUST FAN CFM UNIT FAN UNIT M O D E u .____ ____._ FAN -RPM LU 0)F- 0 VOLT a WEIGHT (LBS.) 0 z� _____ _. U_ LU Architect: Y Uj w _ so N0. INLINE BSQ -XXX -X MODEL TAG IX 0 SP RPM H. P. 1 ty-z FLA BLOWER HOUSING TAG o >- SP FAN MFG EXISTING EXHAUST FAN CFM UNIT FAN UNIT M O D E u .____ ____._ FAN -RPM H.P. 0 VOLT FLA WEIGHT (LBS.) REMARKS _____ _. Y SF11 N0. INLINE BSQ -XXX -X MODEL TAG j CFM SP RPM H. P. 1 VOLT FLA BLOWER HOUSING TAG CFM SP RPM HP �3 VOLT FLA D -30 SEE PLAN FOR LOCATION SF #2 GREENHECK INLINE BSQ -180 -7 3600 (C� SP INLINE 0.73 14.2 1037 3/4 1 208 - 245 TO BE ADJUST VIA SPEED CONTROLLER. I I EF -1 D -30 EF --1 12450 1.5" 1252 15.000 3 460 19 SEE PLAN FOR LOCATION LL aLLI 2 A4 -92@ IL 1113 Proiect a 920 A4 KSF ** 9960 1.0" 650 5.0 3 460 7.019 * EXISTING FAN TO BE ADJUST /REPLACE UP TO 9960 CFM. PLEASE VERIFY NEW HOOD PLANS BY KITCHEN CONSULTANT. ** AS TAG ON NEW PLANS. PRESSURIZATION FANS SF #1 (KITCHEN AREA) AND SF #2 (SITTING AREA) FAN UNIT MFG FAN UNIT MODEL # CFM HOUSING (DIMMESION) BHP SONES FAN -RPM H.P. 0 VOLT FLA WEIGHT (LBS.) REMARKS TAG Y SF11 GREENHECK INLINE BSQ -XXX -X 2200 (® SP INLINE - - _ - 1 208 - - TO BE ADJUST VIA SPEED CONTROLLER. U5 w 0.25 IN WG) (XXXXXXX) .0 0 SEE PLAN FOR LOCATION SF #2 GREENHECK INLINE BSQ -180 -7 3600 (C� SP INLINE 0.73 14.2 1037 3/4 1 208 - 245 TO BE ADJUST VIA SPEED CONTROLLER. I �o 0.25 IN WG) (28X28X28) =o Up -] I- U SEE PLAN FOR LOCATION 1. SF #1 AND MVD ASSOCIATED WITH IT SHALL BE INTERLOCKED WITH HOOD'S SYSTEM. MVD SHALL CLOSING WHEN FAN STOP WORKING 1. SF #2 AND MVD ASSOCIATED WITH IT SHALL BE INTERLOCKED WITH AHU'S 3,4,5 MVD SHALL BE INTERLOCK WITH UNIT, CLOSING WHEN FAN STOP WORKING 1 1 2 � 3 1 10 F- = U = _ 'S z JORGE EDUARDO GON%ALEZ,AIA o 0 AR 94751 / ID 5595 / LEED Alo 0 Z b 0 Revisions f g w w HVAC - GENERAL AND SPECIFIC NOTES, SCHEDULES AND LEGEND 0 SCALE: 11 12 I 13 14 15 16 W N.T.S. IVI U Pl a� w o U) of w a- m a 17 ^ of u_ oZ o� o� Y Z LU J IX �Cr Cr U5 w ° .0 0 iL �o �o =o Up I- U LL aLLI P120928 LLJ LU IL 1113 Proiect a 05/7/2013 T z Date: a Author U, w Drawn / Checked = Z HVAC - GENERAL AND SPECIFIC NOTES, SCHEDULES AND LEGEND 0 SCALE: 11 12 I 13 14 15 16 W N.T.S. IVI U Pl a� w o U) of w a- m a 17 ^