13-518-003(VI L K i H G A 1 2 3 4 5 6 J- 7 8 9 10 1 1 1 2 1 ., 14 15 Demolition Notes 1.— THIS JOB INVOLVE EXTENDED RENOVATION WORK. EC SHALL MAKE A DEEP SITE JOB INVESTIGATION TO VERIFIED IN FIELD ACTUAL CONDITION. SITE JOB VISIT IS MANDATORY TO BID THIS PROJECT. ALL AREAS, INCLUDING WALLS, FLOOR AND /OR CEILING WHERE DEMOLITION WORK TAKE PLACE AND ELECTRICAL LIGHTS, OUTLETS, DEVICES, EQUIPMENTS, DATA /TEL SYSTEM, OR OTHERS SHALL BE REMOVED. EXISTING WIRES /CONDUITS MAYBE REUSED FOR FUTURE RENOVATION WORK, SHOULD REMAIN IN PLACE, PROPERLY CAPPED AND STRAPPED, WHERE REQUIRED. ANY CHANGES /CORRECTION /MODIFICA11ON DUE TO UNFORESEEN CONDITION /LACK OF INFORMATION OR ANY OTHER SITUATION THAT IMPLIES ADDITIONAL COST TO THE PROJECT GSPG CONSULTING CORP, DO NOT ACCEPT RESPONSIBILITY. EC SHALL CONDUCT A FIELD INVESTIGATION AND CONTACT THE ENGINEERS IMMEDIATELY PRIOR TO COMMENCE TO WORK, EC /GC HAVE 5 WORKING DAYS AFTER COMMENCE DEMOLITION WORK TO NOTIFY THE ENGINEER IF ANY DISCREPANCY IS FOUND IN SET OF DWGS, AFTER THAT GSPG CONSULTING WILL CONSIDER THE PLANS ACCURACY ACCEPTABLE AND ADDITIONAL FEES MAY APPLIES TO ANY CORRECTION REQUESTED. 2.— ALL WORK SHALL BE DONE IN A NEAT AND WORKMANLIKE MANNER. 3.— ALL WORK SHALL BE DONE IN FULL ACCORDANCE WITH ALL CHAPTERS OF THE NATIONAL ELECTRICAL CODE, ALL APPLICABLE STATE AND LOCAL CODES, AND ORDINANCES, AND THE LOCAL UTILITY CO, IF REQUIRES. ALSO SHALL COMPLY W /F.B.C. 2010 & N.E.C. LATEST EDITION. 4.— ALL SIGNAGE AND LIFESAFETY DEVICES SHALL BE REMOVED IF REQUIRED AND REINSTALLED IN SIMILAR LOCATION. LIFE SAFETY DEVICES SHALL REMAIN OPERATIONAL AT ALL TIMES. 5.— CONTRACTOR SHALL ASSURE THAT EXISTING MATERIALS, FINISHES AND EQUIPMENT THAT ARE SCHEDULED OR EXPECTED TO REMAIN ARE PROTECTED FROM DAMAGE. 6.— ALL EXISTING LIGHT FIXTURES IN PORTIONS OF THE CEILING TO BE REMOVED SHALL BE REMOVED AND STORED. ALL LIGHT FIXTURES THAT REMAIN AFTER THE WORK HAS BEEN COMPLETED SHALL BE RETURNED TO THE LANDLORD. 7.— EXISTING POWER /DATA IN DEMO AREAS TO BE REMOVED. DATA CABLES TO BE REMOVED. POWER CIRCUIT IS TO REMAIN IN AREA FOR LATER REUSE. COORDINATE WITH ARCHITECTS /OWNER AND LOW VOLTAGE INSTALLER IF AVAILABLE ALL EQUIPMENTS, DEVICES RECEPTACLES AND DATA /TEL SYSTEM OUTLETS SHALL BE REMOVED DEMOLITION PLAN SCALE; 1/8" = P-0" C N] 0 REMOVE ALL COLUMN DECORATIVE FINISHES AND LEAVE THE COLUMN STRUCTURE EXPOSED 0 REMOVE FINISHES `' n ALL RECEPTACLES AND WALL MOUNTED lcz��,� FIXTURES SHALL BE REMOVE J RCP WILL BE UNDER TOTAL RENOVATION U MOST OF EXISTING LIGHTS FIXTURES AND CONTROLS SHALL BE REMOVED. TEMPORARY LIGHTS SHALL BE INSTALLED TO KEEP n SAFETY WORKING ILLUMINATION LEVELS. SEE NOTES FOR ADDITIONAL INFO -- _JU- -- F= \ r ME MS WOMEN'S RESTROOM RESTROOM TO REMAIN TO REMAIN ALL KITCHEN EQUIPMENT SHALL BE REMOVED IN COORDINATION WITH NEW KITCHEN DESIGN. PROPERLY CAP /SEAL/TERMINATE ALL ELECTRICAL CONNECTIONS AS REQUIRED. ---- w ZO ZO Ao 0 �Q O ae OG W Z adz WN C7 i Id. rn N � ° V p m� Q {W� ° = O GR i U W� I I 440 NW 732nd C7 MIAMI, FLORIDA 33782 emait: gspgatcaran @att.net Tetephone:786.574.3300 A Fax :305.599.8787 Certiticate8: 30290 Florida Registration: 56754 SEAL GEN FTq�vo , �� No. 56754 ", 1 v: * iiz o� : STATE OF S t ®''t $11 11 S DAB May 08, 2013 i GERARDO SDM PEAEZ- GALCERAN FLORIDA REG. 140. 56754 t PROFESSIONAL ENGMEER e It E c L U Proiect No. cy) LL 4 05/7/2013 7 8 C P1r\ W Author cy) a LL Drawn / Checked 17 mm ` "J � Q z W Q o Cr c r� V) o Z LL - J a LL Cr C w J LL v ^ < U W W Lu a CL CL _ r W O a a V j �./ / Wz �_ 0 F- c� W0 C/) a zz a � LIJ a � � Z � Z- °LLJ a a LO W '7 U (D z w Z O CL Q Architect: Z W �! L % 4' r A °O -A= .LL1 iokij i IJARDOGONZALEZ,AIA" AR JA7,5] IQ` X55$5 E DEED AP O Revisions O a Proiect No. 05/7/2013 7 8 Date: 10 11 12 Author 14 15 Drawn / Checked 17 E 1 7 8 9 10 11 12 13 14 15 16 17