13-1255-012PLUMB 1 NC
MATERIALS
A. 5ANITARY 5EWER - CAST IRON OR COPPER PIPING MAY BE USED EXCEPT
THAT ALL PIPING BELOW GRADE SHALL BE CAST IRON. VENTS TWO
INCHES (29 IN SIZE AND SMALLER MAY BE EITHER SCHEDULED 40
GALVANIZED STEEL OR COPPER PIPING.
B. DOMESTIC WATER AND HOT WATER PIPING SHALL BE COPPER TYPE "L"
INSULATED WITH ARMAFLEX OR EQUIVALENT INSULATING TO A THICK -
NE55 OF I".
G. GA5 PIPING SHALL BE BLACK STEEL 5GHEDULED 40 WITH 5GREWED
F ITT IN65.
D. CHILLED WATER SUPPLY AND RETURN PIPING SHALL BE GALVANIZED
STEEL PIPE. (STANDARD WALL) OR TYPE "M" HARD COPPER TUBIN5.
ALL PIPIN5 SHALL BE INSULATED WITH I" THICK OWEN5 CORNING
FIBEROLA55 25 A5J/55L OR EQUAL.
MAKINS UP PIPE
A. 5GREWED PIPE SHALL BE MADE UP WITH PIPE COMPOUND APPLIED TO
THE MALE THREAD WITH NOT MORE THAN TWO THREADS LEFT EXPOSED.
PIPE SHALL BE REAMED AFTER THREADING.
B. BELOW GRADE SANITARY PIPIN5 5HALL BE CAST IRON PIPE AND SHALL
BE MADE UP WITH ONE THIRD OF THE HUB CAULKED WITH FIRST
QUALITY OAKUM, AND THE REMAINDER FILLED WITH FIRST QUALITY
GAULKINS AT ONE POURING AND CAULKED TIGHT. ABOVE GRADE TGG
SHALL HAVE OPTION OF U5IN5 PVG AS CODE PERMITS.
G. COPPER JOINTS SHALL BE MADE UP WITH q5 -5 SOLDER.
HAN6ER5 AND 5UPPORT5
HORIZONTAL PIPIN5 SHALL BE SUPPORTED AT INTERVALS NOT TO EXCEED
10 " -0" WITH 5WIVEL SPLIT PIPE HAN6,ER5 EQUAL TO CRANE NO. IggF OR
6RINNELL NO. 104. VERTICAL PIPING SHALL BE SUPPORTED BY MEANS OF
WROUGHT IRON CLAMPS 505PENDED FROM THE UNDER51DE OF STRUCTURE WITH
HANGER RODS.
GLEANOUT5
CLEANOUTS SHALL BE AS MANUFACTURED BY J05AM, ZURN MFG. CO. OR EQUAL
AND SHALL BE IN5TALLED AT ALL BENDS, ANGLE-5, AND ENDS OF ALL WASTE
AND SEWER LINES, AS CALLED FOR ON THE DRAWINGS, AND AS REQUIRED BY
LOCAL CODES. ALL GLEANOUT5 SHALL BE BROUGHT TO GRADE, AND IN ALL
CA5E5, 5HALL BE PROVIDED WITH 5UFFIGIENT SPACE FOR RODDIN6.
FIXTURES
A. PAPER TOWEL DISPENSER - DI5PEN5E5 400 G -FOLD OR 525 MULTIFOLD
PAPER TOWELS. CABINET - STAINLESS STEEL (BOBRICK EQUIPMENT
#5 -262 OR EQUIVALENT).
B. MIRROR - W' X 30" WITH ONE PIECE ROLL FORMED FRAME, TYPE
304 5TAINLE55 STEEL, WITH CONGEALED HANGER (BOBRICK EQUIPMENT
#B -2q0 OR EQUIVALENT).
C. SURFACE MOUNTED 50AP DISPENSER - PU5H --UP DI5PEN5ER WITH
V151BLE CONTAINER AND CHROME PLATED MOUNTIN6 BRACKET (BOBRIGK
EQUIPMENT #BI55 OR EQUIVALENT).
D. SURFACE MOUNTED T155UE DI5PEN5ER - HEAVY DUTY ALUMINUM
CA5TIN5; MOLDED HIGH IMPACT PLASTIC SPINDLES; HOLD 2000
SHEET ROLLS (BOBRICK EQUIPMENT #8 -2730 W/O CONTROLLED DELIVERY
OR EQUIVALENT).
E. CRAB BARS FOR THE PHY51GALLY HANDICAPPED, AS REQUIRED: 18
5AUCE, TYPE 304 5TAINLE55 STEEL WITH NON -SLIP GRIPPING SUR-
FACE; EXP05ED MOUNTING PLATES - LENCTH5 AS REQUIRED BY STATE
AND LOCAL CODES (BOBRICK EQUIPMENT #5-(b106 5ERIE5 OR
EQUIVALENT).
F. WASTE RECEPTACLE - METAL FREE 5TANDIN5 WASTE WITH OPEN TOP.
5. OWNER'S CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER
INSTALLATION OF ALL TOILET ACCESSORIES INCLUDING PROPER
BLOGKING IN WALL.
VALVES
ALL VALVES SHALL BE BRA55 AND MANUFACTURED BY CRANE, NIBGO,
5TOGKHAM, LUNKENHEIMER, NORDSTROM, GRINNELL OR EQUAL.
SPRINKLER 5Y5TEM
A. SHOP DRAWIN55 - THE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP
DRAWING5 TO THE TENANT'S LANDLORD AND TO THE APPROPRIATE
RATING BUREAU FOR THEIR APPROVAL. A GOP'( OF THE APPROVAL
LETTER FROM THE RATING BUREAU SHALL BE FORWARDED TO THE
TENANTS LANDLORD AND TO:
MIKE 50RMAN
GENERAL NUTRITION CORPORATION
300 SIXTH AVENUE
PITTSBURGH, PA 15222
B. SPRINKLER HEADS - 5HOW WINDOWS - HIGH TEMPERATURE. CHROME
PLATED, COMPLETELY RECESSED TYPE. 5ALE5 AND OFFICE AREA -
CHROME PLATED, 5EMI- RECE55ED TYPE. 5TORA6E, TOILET AND WORK
AREA WITH GEILIN55 - BRASS, PENDANT TYPE. 5TORA5E AND WORK
AREA WITHOUT CEILIN55 - BRA55 UPRIGHT TYPE.
ROUGH -IN5
FOR SECOND LEVEL STORES, THE TENANT'S GENERAL CONTRACTOR SHALL RUN
ALL LINES REQUIRED FOR PLUMBING ROUGH -IN5 TIGHT A6AIN5T THE UNDER -
51DE OF THE SECOND FLOOR LEVEL. THE SECOND FLOOR STRUCTURAL SLAB
SHALL BE CORED AS REQUIRED TO INSTALL THESE ITEMS AT THE LOCATIONS
5HOWN ON THE PLANS.
TESTING AND ADJU5TIN5
CONTRACTOR WILL DEMONSTRATE OPERATION OF 5Y5TEM TO FULL 5ATI5-
FACTION OF TENANT, WILL BALANCE AIR FLOW IN AC60R.DANGE WITH AIR
QUANTITIES ON DRAWIN65 AND WILL RECORD VOLUME READINGS IN ACCOR-
DANCE WITH A5HAE AND PROVIDE SAME TO TENANT. 6A5 PIPING SHALL
WITHSTAND AIR PRESSURE TESTING PER UNIFORM PLUMBING CODE.
GUARANTEE
ALL MATERIALS, EQUIPMENT, AND WORKMANSHIP SHALL BE GUARANTEED FOR
A PERIOD OF ONE (1) YEAR AFTER DATE OF ACCEPTANCE. THE COMPLETED
SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY TENANT SHALL BE
A CONDITION OF THI5 CONTRACT. ALL WORK FOUND TO BE DEFECTIVE SHALL
BE REPAIRED OR REPLACED BY THI5 SUBCONTRACTOR WITHOUT ADDITIONAL
CHARGE TO THE TENANT.
MECHANICAL
TEMPORARY 5ERVIGE5
THE CONTRACTOR SHALL PROVIDE THE FOLLOWING SPECIFIC ITEMS OF
TEMPORARY SERVICES:
A. TELEPHONE - THE TENANT'S GENERAL CONTRACTOR SHALL INSTALL A
JOB 51TE TELEPHONE AND NOTIFY TENANT AS L15TED ON SHEET A -1
OF THE TELEPHONE NUMBER AND THE NAME OF THE SUPERINTENDENT.
B. TEMPORARY WATER - WATER REQUIRED IN THE PERFORMANCE OF THE
CONTRACT SHALL BE PROVIDED AND PAID FOR BY THE CONTRACTOR.
WATER USED FOR HUMAN CONSUMPTION SHALL CONFORM TO REQUIRE -
MENT5 OF STATE AND LOCAL AUTHORITIES FOR POTABLE WATER.
G. TEMPORARY ELECTRICITY - TEMPORARY ELECTRIC SERVICE REQUIRED
IN THE PERFORMANCE OF THE CONTRACT SHALL BE FURNISHED AND
PAID FOR BY THE CONTRACTOR WH0 SHALL FURNISH, INSTALL, AND
MAINTAIN ALL TEMPORARY OVERHEAD CONSTRUCTION, METERS, DROPS,
AND OTHER WIRING AND FITTIN65 FOR BOTH LIGHT AND POWER AT
LOCATIONS REQUIRED IN THE WORK AND SHALL BEAR THE C05T OF
MAKING THE 5ERVIGE CONNECTIONS. BEFORE FINAL ACCEPTANCE,
TEMPORARY ELEGTRIGAL 5ERVIGE FACILITIES IN5TALLED BY THE
CONTRACTOR SHALL BE REMOVED AND THE 5ERVIGE CONNECTIONS
5EVERED IN ACCEPTABLE MANNER.
D. TEMPORARY HEAT - WHEN REQUIRED FOR PROPER INSTALLATION OR
PROTECTION OF ANY PORTION OF THE WORK, THE CONTRACTOR 5HALL
FURNISH AND INSTALL TEMPORARY HEATING UNITS AS APPROVED BY
THE LANDLORD OR LOCAL AUTHORITY.
E. C05T OF LANDLORD PROVIDED UTILITY SERVICES - IF THE LANDLORD
ELECTS TO PROVIDE TEMPORARY UTILITY 5ERVIGE5, THE CONTRACTOR
WILL BE 50 INFORMED BY THE TENANT. THE CONTRACTOR SHALL MAKE
PROVISIONS OR COORDINATE WITH LANDLORD'S 6ENERAL CONSTRUCTOR
TO PAY THE COST OF SAID TEMPORARY CONSTRUCTION AND UTILITY
SERVICES.
NOTE FOR TENANT GENERAL CONTRACTOR
IT 15 THE RE5PON51BILITY OF THE TENANT'S GENERAL CONTRACTOR TO
MAKE USE OF APPLICABLE NOTES AND SPECIFICATIONS LISTED ON THI5
SHEET AS THEY MAY PERTAIN TO THE SPEGIFIG JOB.
HANDICAP SPECIFICATION: ARCHITECTURAL BARRIERS ACT, 42 U56. 4151 -4157
GENERAL
THE WORK COVERED BY THESE SPECIFICATIONS INCLUDES BUT 15 NOT
LIMITED TO PROVIDIN5 ALL LABOR, MATERIAL, AND EQUIPMENT NECESSARY
TO COMPLY WITH HANDICAP REQUIREMENTS IN THI5 ESTABLISHMENT.
TOILET ROOM ACCESSORIES
A. MIRROR BOTTOM EDGE SHALL BE LOCATED 40" MAXIMUM ABOVE FLOOR.
B. TOILET T155UE DISPENSER SHALL BE MOUNTED WITHIN 12" FROM THE
FRONT EDGE OF TOILET SEAT. Iq" MIN. A.F.F. (4.16.6)
G. OPERATING PARTS OF DISPENSER AND DISPOSAL FIXTURES SHALL BE
WITHIN 40" OF FLOOR. (4.23 .7)
WATER GL05ET SRAB BARS
A. ONE AT 51DE 42" LONG EXTENDING IN FRONT OF WATER CL05ET; ONE
AT REAR 36" LONG CENTERED ON WATER CLOSET; BOTH MOUNTED 36"
ABOVE FLOOR. (4.26)
B. BARS SHALL BE 1 -1/4" - 1 -1/2" IN DIAMETER WITH 1 -1/2" CLEAR-
ANCE TO WALL. (4.26)
G. BAR FASTENERS AND MOUNTING SUPPORT SHALL WITHSTAND 250 LB5./
FT. BENDING, SHEAR, AND TENSION. (4.26)
WATER GL05ET
A. HEIGHT OF WATER GLO5ET SEAT SHALL BE IV' A.F.F.( 4.16)
B. FORGE REQUIRED TO ACTIVATE FLUSH VALVE SHALL BE 5 LB5.
MAXIMUM (4.16.5)
LAVATORY
A. PROVIDE 30" x 45" CLEAR FLOOR SPACE FOR FORWARD APPROACH,
INGLUDING KNEE AND TOE SPACE. Klcl.3)
B. PROVIDE GLEAR 5PAGE BENEATH LAVATORY 2q " HIGH x 30" WIDE x
W DEEP (KNEE SPACE) AND q" HIGH FROM THE FLOOR x 30" WIDE x
17" DEEP FROM FRONT OF LAVATORY (TOE SPACE). (4.IC12)
G. HOT WATER AND DRAIN PIPE UNDER LAVATORY SHALL BE INSULATED
WITH ARMSTRONG ARMFLEX PIPE INSULATION. MITER OUT PIECES
JOINTED TOGETHER WITH ARMSTRONG 520 ADHESIVE. (4.lq.4)
D. FAUCET CONTROLS SHALL BE OF THE TYPE NOT REQUIRING TIGHT
GRA5PIN5, PINGHIN6, OR TWI5TIN6 OF WR15T AND AN OPERATING
FORGE NOT EXCEEDING 5 LB5. (4.Iq.5)
E. SELF- GLO51N5 VALVES SHALL BE OF THE TYPE REMAINING OPEN FOR AT
LEAST 10 SECONDS. KICIS)
PLUMBING FIXTURE CONNOCT I ON SCHEMULr
MARK
FIXTURE
GW
HW
W
V
REMARKS
HG
WATER OL05ET
1/2"
-
4"
21"
EX15TINO TO REMAIN.
RHEEM #EGSPIO
(HANDICAP)
u0z
LAV
LAVATORY
1/2"
1/2"
21"
1 -1/2"
EXI5TING TO REMAIN.
(HANDICAP)
•
DF
WATER COOLER
1/21"
-
21'
1 -1/2"
EXISTING TO REMAIN.
FD
FLOOR DRAIN
1/2"
-
311
1 -1/2"
EXISTING TO REMAIN.
MOP
SERVICE SINK
1/2"
1/2"
3"
1 -1/2"
a. FIAT #M515-2424; 24 "x24 "xlO" ONE -PIECE MOLDED STONE W/ 3" DRAIN,
VINYL BUMPERGUARD ON 3 SIDES.
b. SERVICE FAUCET #830 -AA; 8" CENTERS INLETS WITH BACK FLOW
PREVENTER/VAGUUM BREAKER, 3/4" HOSE TREADED OUTLET,
AND PAIL HOOK W/ WALL SUPPORT
GO
GLEANOUT
-
-
3
-
a. WADE # 6000, CAST IRON W/ THREADED ADJUSTABLE HOUSING
NOTES
1. ALL FIXTURES SHALL HAVE AN INDIVIDUAL SHUTOFF VALVE.
2. ALL FIXTURES SHALL BE PROVIDED W/ A SHOKTROL.
3. INSTALL A METER AND/ OR BACKFLOW PREVENTOR AS
LOCAL CODE REQUIRES.
1. THE CONTRACTOR SHALL BE FAMILIAR W1TH ALL
EXISTING CONDITIONS PRIOR TO SUBMITTING A BID.
2. GLEAN AND REPAIR ALL EXISTING PLUMBING FIXTURES
TO A NEW APPEARANCE AND GOOD WORKING CONDITION.
3. INSTALL NEW MOP SINK 8 WATER HEATER AS SHOWN.
CONNECT NEW 3" WASTE, 1 -1/2" VENT AND 3/4" G.W.
TO EXISTING PLUMBING LINES, FIELD VERIFY LOCATION.
WATrER H EATrEf"R SCE"- MMULM
MARK
RECOVERY
5TORA6E
GALLONS
LINING
MAXIMUM INPUT
REMARKS
GPH
R15EOF
W.H.
14
60
10
OLA55
1.5 KW @ 120WI (P
RHEEM #EGSPIO
1
1
1
I"
60
MOP
WASTE 4 \00ormNir IQ I SWR
NO SCALE
I
--�- 1/2" TO/FROM
WATER HEATER
WH
i
Lt
BALL VALVE
(TYP)
HEAT TF
H/W OUT —y-
STEEL TONIC STRAP
ANCHOR TO WALL
TYPICAL.
24" X 24" X 3/4"
EXT. GRADE
PLY. PLATFORM
2" X 4" WD. 4 0
BLOCKING ANCHOR
SECURELY TO WALL
)RAIN PAN LINE TO
E RIM OF MOP SINK. F-
e
3" X 1 1/2" X 14 GA.
SLOTTED ANGLE5 (TYP.)
VAALLVE CUUM RELIEF
INSULATION
Gm SUPPLY
—
—UNION
(TYP)
_r_---WATT5 NO. DET -5
EXPANSION TANK
2 GALLON CAPACITY
-2 318" X 24" DIA.
POLYETHYLENE
DRAIN PAN
WATER HEATER DETAIL_
NO 5GALE
I. WATER HEATER 15 ELECTRIC AS SCHEDULED.
ItOJER rh9l
SGALE: 1/4" = 1' -0"
.B• OF
i•
PLUM51NG KEYED NOTES :
I CONNECT NEW 3" WASTE LINE TO EXISTING WASTE
LINE IN AREA.
FIELD COORDINATE LOCATION AND FLOW DIRECTION.
Q2 CONNECT NEW 3/4" GOLD WATER LINE TO EXISTING
LINE IN AREA. FIELD COORDINATE LOCATION.
�! CONNECT NEW 1 -1/2" VENT LINE TO EXI5TING VENT LINE
IN AREA. FIELD COORDINATE LOCATION.
vim/ i •
i
1 i •
0
moN
r
I ••
•
K)zj.0
,
•
i
r
rr
r
r
a
I
1 • • /• -
MWs 10/14/2013
Checked By: D.
DAI CHICKID
1 • . �i
ml
Drawing No.
p —
CL 1
C
Lli
LJ
u0z
n
•
•
•
1 • • /• -
MWs 10/14/2013
Checked By: D.
DAI CHICKID
1 • . �i
ml
Drawing No.
p —