Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-900-014
FIRE SPRINKLER SPECIFICATIONS 1. THE DRAWINGS ARE DIAGRAMMATIC AND REQUIRE COORDINATION WITH ARCHITECTURAL, AIR CONDITIONING AND ELECTRICAL PLANS. 2. THE FIRE SPRINKLER CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR THE ENGINEER'S REVIEW, FOR ALL SPECIFIED MATERIALS AND EQUIPMENT PRIOR TO ORDERING, INSTALLATION OR SUBMISSION TO LOCAL A.H.J.. 3. THE FIRE SPRINKLER CONTRACTOR SHALL GUARANTEE ALL WORK AND INSTALLED SPRINKLER SYSTEMS FOR A PERIOD OF ONE YEAR FROM DATE OF "CERTIFICATE OF OCCUPANCY". 4. THIS BUILDING IS DESIGNED PER NFPA 13, 14 AND 20. 5. ABOVE GROUND SPRINKLER PIPING SHALL BE: — SCHEDULE 40 FOR PIPE 1" THRU 2" DIA. W/ THREADED FITTINGS — SCHEDULE 10 FOR PIPE 2 1/2" DIA. AND LARGER W/ GROOVED FITTINGS. 6. DESIGN DENSITY, HEAD TEMPERATURE AND SPACE CLASSIFICATION SHALL BE AS NOTED ON THE PLANS. 7. ALL VALVES SHALL BE UL FM LISTED VALVES WITH TAMPER SWITCHES OS &Y CAST IRON BODY. 8. SPRINKLER PIPING SHALL BE PRESSURE TESTED AT 200 PSIG. FOR 2 HOURS. MAXIMUM PIPE HANGER SPACING DESIGNED 3/4" 1" 1 1/4- 1 1/2- 2" 2 1/2- 3" 4" 6" THREADED LT. WALL STEEL N/A 12' 12' 12' 12' 12' N/A N/A N/A STEEL PIPING N/A 12' 12' 12' 12' 12' 12' 12' 12' NOTE: SPRINKLER LEGEND DESIGNED DAS ' DRAWN DAB r'!► CHECKED DAS .r ,h A l�l ° 4. CONC. SLAB J V--CONC. INSERT -ALL THREAD ROD _---PIPE RING HANGER PIPE HANGER DETAIL NOT TO SCALE cc ml FIRE PROTECTION PLAN ARMOVERS GREATER THAN 24" IN LENGTH SHALL BE SUPPORTED BY A HANGER. SPRINKLER HEAD DETAILS: NOT TO SCALE GENERAL NOTES: 1. REPLACE ALL EXISTING BLACK SPRINKLER HEADS WITH NEW PER SPRINKLER SCHEDULE. 2. ALL SPRINKLER HEADS ARE NEW UNLESS NOTED OTHERWISE. ,�E C 5�V0F0k��YRO; ��Z•IT�' ����11'1"I��`( I tit *�1(�rF, SCALE: 1/4" = 1$ -0" WARNING! MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITF 'OMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDINC ODES. THIS DRAWING IS THE SOLE PROPERTY OF "HENZ ENGINEERING Inc." AND IS 4 ;NSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE XPRESS WRITTEN PERMISSION OF HENZ ENGINEERING INC. I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHORIZATION #3880 TO PROVIDE THE ENGINEERING SERVICE. o 59492 •';�c ' CU(1SULTInG EfiGinaRS N 240C ' IB i� / : LU OF . uu: ss 10 N N\ � r11111r ommercia IVd 2A Lauderdale By The Sea, FL 33308 T 954.523.4933 F 954.523.5052 www.henz.com PROJECT No.: 12059.00 architect NORBERTO ROSENSTEIN ARCHITECT , INC. MRCFUECM - NIM DE" - RAM 126 S. FEDERAL HIGHWAY SURE f 202 DAM BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX= (954) 922 -7388 EMAIL*doero9enet9kwc Ntect c:om WEB WWWlos"ekwcNteckcom STATE REG. NO. AR0016674 NATL. REG. NO. 69178 ©20M NORdERTO R08"TEW ARCHITECT, IIrC. ALL R,GHT6 REBERYED. THIS DOCUMENT OR PARTS TMIREOR, MAY NOT DE IREPR=ICW IN ANY FORM UTHOUT FERhQ86I0K h, DESIGNED DAS ' DRAWN DAB r'!► CHECKED DAS .r I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME DR UNDER MY SUPERVISION, AND TO THE BEST DF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. R E V I S 1 0 N S COMM. 2012 -37 DATE 2/14/2011 5701 SUNSET DR SUITE F06 ISIS WELLNESS NAILBAR SOUTH MIAMI FLORIDA, 33143 FIRE PROTECTION PLAN FP -1 Q 1 a