12-900-009AIR CONDITIONING SPECIFICATIONS L GENERAL: A. ALL DIMENSIONS AND ACTUAL CONSTRUCTION CONDITIONS MUST BE VERIFIED AT THE PROJECT SITE PRIOR TO SUBMITTING BID. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES IMMEDIATELY. B. THESE DRAWINGS ARE DIAGRAMMATIC AND REQUIRE CLOSE COORDINATION WITH EXISTING STRUCTURE, LIGHTS, CONDUITS, PLUMBING AND CEILING SYSTEM. THE CEILING SPACE IS EXTREMELY TIGHT AND WILL REQUIRE CAREFUL ADVANCE PLANNING BEFORE DUCT INSTALLATION. THE CONTRACTORS PRICE FOR THIS PROJECT SHALL INCLUDE A SITE VISIT TO FIELD VERIFY, ALL COORDINATION, DUCT TRANSITIONS AND FIELD ROUTING AS REQUIRED FOR A COMPLETE OPERATING AND TESTED SYSTEM. C. SUBMIT MANUFACTURERS DATA AND SHOP DRAWINGS ON ALL EQUIPMENT, MATERIALS AND DUCT SYSTEM LAYOUT FOR REVIEW BY THE ENGINEER PRIOR TO ORDERING, FABRICATION OR INSTALLATION. PRIOR TO ORDERING ANY EQUIPMENT, IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THAT EQUIPMENT VOLTAGE SPECIFIED IS AVAILABLE. D. ALL MOTORS STARTERS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR TO BE WIRED AND INSTALLED BY THE ELECTRICAL CONTRACTOR. E. ALL WORK SHALL BE IN STRICT ACCORDANCE WITH THE FOLLOWING CODES: I. THE FLORIDA BUILDING CODE 2010 2. NFPA -90A AIR CONDITIONING AND VENTILATION 3. SMACNA, LOW VELOCITY DUCT CONSTRUCTION 4. NFPA 101, LIFE SAFETY CODE 2. MATERIALS: A. GALVANIZED STEEL SHEET METAL DUCT WORK INSTALLED IN ACCORDANCE WITH "SMACNA" STANDARDS WITH R -6 FIBERGLASS DUCT WRAP INSULATION. PROVIDE MANUAL VOLUME DAMPERS AT ALL BRANCH TAKE -OFFS. PROVIDE TURNING VANES AT ALL ELBOWS. FLEXIBLE ROUND DUCTS MAY BE USED FOR DIFFUSER DROPS AS SHOWN ON PLANS. SUBMIT SHOP DRAWINGS. B. ALL CEILING DIFFUSERS SHALL HAVE OPPOSED BLADE DAMPERS. C. OUTSIDE AIR AND EXHAUST DUCTS SHALL BE AIR LEAK SEALED GALVANIZED SHEET METAL 3. TEST AND BALANCE: A. AN AABC OR NEBB CERTIFIED INDEPENDENT TEST AND BALANCE COMPANY SHALL BALANCE THE SYSTEM TO DESIGN VALUES ON THE DRAWINGS TO WITHIN PLUS 10% OR MINUS 5X PROVIDE WRITTEN REPORT TO DOCUMENT AIR SYSTEM PERFORMANCE, MOTOR SPEED, AMPS, SUPPLY AND EXHAUST FAN CFM VALUES AND AIR CONDITIONING PERFORMANCE FOR ENGINEER REVIEW PRIOR TO PROJECT COMPLETION. IT IS THE RESPONSIBILITY OF THE TEST AND BALANCE COMPANY TO PERFORM MODIFICATIONS TO THE SPECIFIED EQUIPMENT, BELTS, PULLEYS ETC. TO ACHIEVE THE DESIGN VALUES LISTED ON THE DRAWINGS. 4. CONTRACTOR'S WARRANTY: A. CONTRACTOR SHALL PROVIDE A ONE YEAR WARRANTY FOR ALL EQUIPMENT AND SYSTEMS FROM DATE OF FINAL ACCEPTANCE BY THE OWNER, (CERTIFICATE OF OCCUPANCY). HVAC SYMBOL LEGEND: (D THERMOSTAT PANEL- ROOF MTD. EXH. FAN (D REMOTE BULB SENSOR DUCT TURN DOWN ® DUCT SMOKE DETECTOR MOUNT (DUCT OPENING SIZES): MAXIMUM PANEL:- 60 "x54" DUCT TURN UP ® TEST, RESET &ANNUNCIATOR "ft-'0 4 "x4" 83 W VOLTS 115/1 /60 FLEXIBLE DUCT MANUF. TRANSITION ME MODEL NO. SP -1380 DBF4XLT NOTES EXISTING SUPPLY 3,5 TURNING VANE FOE Vot = Voz - QUATION 4-3) AHU -1 OUTSIDE AIR RETAIL NET FLOOR AREA = 8CSQFT EXISTING RETURN 800 X 15/1000 = 12 PEOPLE 45' BRANCH DUCT TAKE -OFF ®R RELOCATED VOZ = (186)/(1.0) = 186 CFM 1 -WAY Vot = 186 CFM SUPPLY NOTES: BALANCE AHU -1 TO 19CFM 0 /A. HORIZONTAL FIRE DAMPER RELOCATED RETURN R R D. MANUAL VOLUME DAMPER FN NEW SUPPLY SEE NOTE RETURN REGISTER 24x24 FILTER BACK RETURN SUPPLY DIFFUSER 17IN NEW RETURN RETURN AIR GRILLE FIRE DAMPER COMBINATION FIRE /SMOKE DAMPER AIR FLOW DIRECTION NOTES: 1. ALL AIR DISTRIBUTION DEVICES SHALL BE OF ALUMINUM CONSTRUCTION. 2. FINISH FOR ALL AIR DISTRIBUTION DEVICES SHALL BE AS SELECTED BY ARCHITECT /OWNER 3. PROVIDE INSULATING BLANKETS ON � MOTORIZED DAMPER ® EXHAUST FAN -D4- VALVE NOTES: GYPSUM WA RETAINING ANGLE 1 1/4x1 1/4 x1/8" al GYPSUM FILLER DAMPER S VERTICAL MOUNT U.L. SIZE LIMITATIONS VERTICAL MOUNT (DUCT OPENING SIZES); MAXIMUM PANEL- 60 "x54" MAXIMUM ASSEMBLY: 120 "x114" MINIMUM PANEL: 4 "x4" HORIZONTAL MOUNT (DUCT OPENING SIZES): MAXIMUM PANEL:- 60 "x54" MAXIMUM ASSEMBLY. 102 "x54" MINIMUM PANEL- 4 "x4" FAN SCHEDULE MARK EF -1 DF -1 USE TOILET DRYER CFM 69 103 S.P. IN WATER 0.250 0.8" RPM 900 1000 DRIVE DIRECT DIRECT HP/WATTS 54 W 83 W VOLTS 115/1 /60 115/1 /60 MANUF. GREENHECK FANTECH MODEL NO. SP -1380 DBF4XLT NOTES 1,4 3,5 I. PROVIDE BACKDRAFT DAMPER 2. PROVIDE BUG SCREEN 3. PROVIDE WALL CAP 4. CONTROLLED BY WALL SWITCH 5. CONTROLLED BY PRESSURE SWITCH OUTSIDE AIR CXULATION: FLORIDA MECHANICAL COD010 TABLE 403.3 OCCUPANCY Rp R,, CFM/ NECK SIZE OCC. DENSITY CLASSIFICATION CFM/PERSON FM /FT" 2 TMS -AA # /1000 FT" 2 OFFICE SPACES 5 0.06 FIRE RATED ROOF/FLOOR CEILING ASSEMBLY 5 RETAIL SALES 7.5 0.12 C 15 DINING ROOMS 7.5 0.18 70 Vbz = Rp Pz + Ra A - EQUATION 4 -1) Vbz Vo` EQUATION 4 -2) E, SUPPLY SINGLE ZONE SYSTEMS Vot = Voz - QUATION 4-3) AHU -1 OUTSIDE AIR RETAIL NET FLOOR AREA = 8CSQFT 250 -AA 800 X 15/1000 = 12 PEOPLE OBD Vb, _ (7.5)(12) +(0.12)(800) =86 CFM VOZ = (186)/(1.0) = 186 CFM 1 -WAY Vot = 186 CFM NOTES: BALANCE AHU -1 TO 19CFM 0 /A. AIR DISTRIBUTION SCHEDULE: � �;' YES MARK MAKE MODEL CFM/ NECK SIZE DAMPER REMARKS A TITUS TMS -AA 60 -100 CFM 06 "0 NECK OBD SEE NOTE B FIRE RATED ROOF/FLOOR CEILING ASSEMBLY 24x24 105 -200 CFM 08 "0 FIRE STOPPING C SMOKE CONTROL 205 -350 CFM 10 "0 D LAY IN 355 -550 CFM 12 "0 E SUPPLY 555 -800 CFM 14 "0 F TITUS 250 -AA 100 CFM 8x8 NECK OBD SEE NOTE 1 -WAY SUPPLY R TITUS 350FLF 0 -2000 CFM 20x20 NECK SEE NOTE 24x24 FILTER BACK RETURN RETURN NOTES: 1. ALL AIR DISTRIBUTION DEVICES SHALL BE OF ALUMINUM CONSTRUCTION. 2. FINISH FOR ALL AIR DISTRIBUTION DEVICES SHALL BE AS SELECTED BY ARCHITECT /OWNER 3. PROVIDE INSULATING BLANKETS ON BACKS OF SUPPLY DIFFUSERS. 4. REFER TO CONTRACT DRAWINGS AND SPECIFICATIONS FOR OTHER ACCESSORIES AND /OR REQUIREMENTS. NOTES: 1. UNDERWRITERS LABORATORIES LISTED AND 1-1/2 HOUR STANDARD 555, CLASS 'A 2. STANDARD CONSTRUCTION 18 GA. GALVINIZED STEEL 3. PROVIDE 1/8" MOUNTING SCREWS ON 6" CENTERS. 4. PROVIDE ACCESS PANELS IN ADJACENT DUCT FOR ACCESS. NAILOR -HART MODEL 0110 TYPE A 1 1/2 HR "DYNAMIC TYPE" FUSIBLE LINK TEMPERATURE: 1657 FIRE DAMPER DETAIL: NOT TO SCALE SUPPORT FROM STRUCTURE ® /NEOPRENE VIBRA71ON TYPE ISOLATORS AND 3/8" HANGER RODS FROM CONTROLS DTR TO CONTROLS MANUAL AIR VENT %LVE DTS I PIPE 1/4" LINE TO OND. PAN NOTE 1 AUTOMATIC AIR =NT VALVE RET. AIR DUCT PIPE 1/4- LINE) COND. PAN (REFER HVAC PLAN) O 1 Tq COIL R. A. �!t!`� `; �" -- -T I 1 i rJ j S.A. FILTER FINISHED CEILING FLEXILE CONNECTION, TYP. HINGED CABINET DOOR AUX. DRAII PAN WITH FLOAT SWITCH. TO PROVIDE FULL ACCESS INSULATED TRAPPED SUMMER/WINTER CHANGE FAN COND.DRAIN(REFER OVER STRAP-ON AQUASTAT INSULATED CONDENSATEPAN ENLG'D. HVAC PLAN (INSULATE OVER AQUASTAT) FOR ROUTING) PROVIDE CONDENSATE RMP. NOTES: 1. AL ED EQUIPMENT SECTION I INSULATION R LHA2. LL VVES LP PINGAN SHWN TO BE LOCATED COIUMT�BI ET WITH ACCESS FROM BELOW UNIT. FAN COIL UNIT PIPING SCHEMATIC (DUCTED INSTALLATION) NOT TO SCALE MANUAL DAMPER W/ LOCKING ADJUSTMENT HANDLE BRANCH DUCT - BRANCH � I I I I TRUNK DUCT DIRECTION OF DIR CTION OF AIR FLOW AIR FLOW L45' BRANCH DUCT CONNECTION TEE 'M MUM^ vA►ure- 3/4" COPPER CONDENSATE DRAIN WITH 1" K -FLEX INSULATION TO EXISTING RISER. FIELD VERIFY EXACT LOCATION. EXISTING 1" CHILLED WATE LINES. EXTEND CHILLED WATER LINES TO NEW AHL LOCATION. USE 1" COPPE WITH 2" K -FLEX INSULATION. PROVIDE NEW ISOLATION VALVES AND 2 -WAY VALVE. RAISE AHU MINIMUM 18" ABOVE CEILING. MECHANICAL PLAN qi,P Oh, w CIRCULAR DUCT FOR CONNECTION TO FLEX DUCT PROVIDE CLASS 1 FLEX DUCT TO DIFFUSERS. 45' FLARED TAP MAIN TRUNK DUCT INTO TRUNK DUCT MANUAL VOLUME DAMPER. FURNISH CABLE OPERATED REMOTE '20y, CONTROLLED VOLUME DAMPERS IN BRANCH DUCTS LOCATED IN INACCESSIBLE CEILINGS. ROUND NECK CEILING DIFFUSER SPIN COLLAR DETAIL: SPUTTER DAMPER BLADE LSPUTTER DAMPER CONTROL ROD W/ LOCK HANGING HANG ALL DUCT PER SMACNA STANDARDS CHANNEL STRAP & SADDLE NOT TO SCALE ELBOW coRr­...,.. TURI HVAC DUCT DETAILS NOT TO SCALE 4 NEW OUTSIDE AIR �T TO EXISTING MAIN (SIDE AIR DUCT. FIELD 21FY EXACT LOCATION. 4 NEW TOILET iAUST TO EXISTING IN EXHAUST DUCT. LD VERIFY EXACT '.ATION. architect NORBERTO ROSENSTEIN ARCHITECT INC. ARCH16CTH - HrM DPI - FLAW 126 S. FEDERAL HIGHWAY SURE f 202 DAM BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX- (954) 922 -7388 E1ML*do9ro9enstekwc Nteckc omm WEB WWWIO®9I18tekwcI'11teC'LCOII'1 STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYMWT Q20e NOIRMWO ROSENSTEAI ARCHITECT, 24C. ALL RSGHTS RESERVED. THIS DOCUMENT OR PARTS I 14 RSOK MAY NOT ft R£PRODUCSD IN ANY FORM UTHOUT PERI IISSIOK DESIGNED DAS DRAWN DAS CHECKED DAS I HEREBY CERTIFY THAT THESE PLANS :R YLIC WHERE PREPARED BY ME OR UNDER ,R DT BE MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES, l VC> HVAC DESIGN REQUIRES: YES NO DUCT SMOKE DETECTOR FIRE DAMPER(S) SMOKE DAMPER(S) FIRE RATED ENCLOSURE V, FIRE RATED ROOF/FLOOR CEILING ASSEMBLY FIRE STOPPING SMOKE CONTROL WARNING! MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. '0 THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITI 'OMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDIN( 'ODES. THIS DRAWING IS THE SOLE PROPERTY OF "HENZ ENGINEERING Inc." AND IS At NSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE _XPRESS WRITTEN PERMISSION OF HENZ ENGINEERING INC. 1, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERIfJMTAQF AUTHORIZATION #3880 TO PROVIDE THE ENGINEERING SERVICE. �% �i P' "sH•M' �I�f1Z �(1GIfl��RIf1G If1C. �G� E - • Na 5ggg2 congflTin miu[as cc 240 Commercial Blvd 2A LL C * Lauderdale By The Sea, FL 33308 OF 1I q• q .�E T954.523.4933 F 954.523.5052 - -ice 0 F L O pk' `*G�.` �.henz,com ''�•,FSS�ONP� �``� PROJECT No.: 12059.00 R E V I S 1 0 N S COMM. DATE 2012 -37 2/14/2011 5701 SUNSET DR SUITE FOB ISIS WELLNESS NAILBAR SOUTH MIAMI FLORIDA, 33143 MECHANICAL PLAN, M -1 OF 1