Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-900-002
✓ ADJACENT RETAIL TENNANT O F- v L J A F r)34JI 0 j I I ' L A / I I H / L / 011 DE MOL„ITION„ PLAN OA REMOVE ALL FLOORING ELEMENTS INCLUDING BUT NOT LIMITED TO FLOOR TILES, WALL BASE, DRAINS, AND ASSOCIATED COMPONENTS; REPAIR AND PREPARE, FILL -IN EXISTING OPENINGS; ANYTHING THAT WILL INTERFERE WITH A SMOOTH CONCRETE FLOOR TO RECEIVE NEW FINISH. BO REMOVE EXISTING CEILING AND ASSOCIATED COMPONENTS (LIGHTS, SIGNS, VENTS, SOFFITS) REUSE EXISTING STOREFRONT OUTLETS EXISTING SPRINKLERS TO REMAIN AND BE REUSED THRU OUT. © REMOVE EXISTING PARTITIONS AND ASSOCIATED COMPONENTS. O EXISTING STOREFRONT WINDOWS, DOORS AND ALL ASSOCIATED COMPONENTS TO REMAIN. O EXISTING NEUTRAL PIERS TO BE PROTECTED DURING CONSTRUCTION. O EXISTING COLUMN TO REMAIN. PROTECT DURING CONSTRUCTION. © EXISTING ELECTRICAL PANEL AND TRANSFORMER TO REMAIN. OH EXISTING STOREFRONT SOFFIT TO REMAIN. (D REMOVE PLUMBING FIXTURES. CAP AND CONCEAL PLUMBING LINES BELOW FINISHED FLOOR /SLAB. OJ EXISTING PIPES TO REMAIN. PROTECT DURING CONSTRUCTION. KO EXISTING HVAC UNIT TO BE RAISED AND SHIFTED. SHIFT (RELOCATE AND TURN) AS PER MECHANICAL DRAWINGS; RAISE TO CLEAR LIGHTING FIXTURES AND SPRINKLER HEADS, V.I.F. SEE MECHANICAL DWGS. WALL LEGEND EXISTING TO REMAIN ] EXISTING TO BE REMOVED ADDITIONAL DEMOLITION NOTES: - Main electrical service conduit and feeders to remain. - Main service electrical panel /breaker to remain. - Electrical panel and Transformer to remain. - Sprinkler Branches to remain. 021 KEY NOTES AND LEGEND / / / / D EXIT CORRIDOR 60 i0i MALL HALLWAY 0,31 EXISTING CONDITIONS GENERAL DEMOLITION NOTES 1. G.C. SHALL SURVEY THIS PROJECT AND BECOME ZOUGHLY FAMILIAR WITH ALL ASPECTS OF THE WORK REQUIRED. ANY C✓ERED VARIANCE FROM THESE DOCUMENTS SHALL BE BROUGHT TO THE AT-)N OF THE ARCHITECT FOR A SOLUTION BEFORE FINAL PRICING IS GIVEN 1E OWNER. 2. G.C. SHALL MAKE ARRANGEMENTS FOR ALL REQI TEMPORARY PROTECTION (INCLUDE PROTECTION OF EXISTING TEIAND BASE BUILDING PRIOR TO START OF DEMOLITION). 3. G.C. SHALL COORDINATE ALL TRADES AND DISCIR INVOLVED WITH DEMOLITION. 4. DEMOLITION SERVICES AND TEMPORARY WORK PID BY G.C. SHALL NOT, IN ANY WAY, INTERFERE WITH NORMAL BUSINPERATIONS WITHIN THE AFFECTED AND /OR ADJACENT AREAS 5. TEMPORARY WORK SHALL INCLUDE (BUT NOT LI1TO) THE FOLLOWING: A. TEMPORARY LIGHT /POWER B. TEMPORARY WALLS AND /OR FLOORING C. PLASTIC PROTECTION (FIN ANF FUR) D. TEMPORARY CEILING /HVAC 6. G.C. SHALL COORDINATE ALL DEMOLITION AND TARY WORK WITH OWNER'S REP. AS REQUIRED, AND SHALL MAKE ARMENTS FOR REMOVAL OF DEBRIS AND CARTING FROM PREMISES WITH MII DISTURBANCES ON A REGULAR BASIS. 7. G.C. SHALL KEEP THE AFFECTED AREAS CLEAR _ TIMES AND SHALL BE RESPONSIBLE FOR DAILY CLEANUP AND VACUUCARPET AS REQUIRED. 8. NOT USED 9. G.C. SHALL PROVIDE TEMPORARY BARRIERS TO CT ADJACENT AREAS FROM DAMAGE CAUSED BY ALL WORK. 10. THE DRAWINGS DON'T PURPORT TO SHOW ALUTS EXISTING AT THE SITE. IT IS THE RESPONSIBILITY OF THE G.0 TO V)N SITE ALL OBJECTS TO BE PRESERVED AND REPORT TO OWNER ANY FANCY OR QUESTIONABLE ITEMS. 11. G.C. SHALL USE ALL MEANS NECESSARY TO F EXISTING OBJECTS DESIGNATED TO REMAIN AND, IN THE EVENT OF D, IMMEDIATELY MAKE ALL REPAIRS AND REPLACEMENTS NECESSARY TO 'HE APPROVAL OF THE ARCHITECT AT NO ADDITIONAL COST TO THE 12. G.C. SHALL NOTIFY THE OWNER AT LEAST TW(WORKING DAYS PRIOR TO COMMENCEMENT OF DEMOLITION WORK. 13. G.C. SHALL COORDINATE DEMOLITION AND RENF DEBRIS W/ OWNER REPRESENTATIVE. 14. PATCH AND REPAIR FLOOR AS REQUIRED FORLOOR FINISH MATERIAL. 15. CONTRACTOR SHALL TAKE ALL PRECAUTIONS JRES REQUIRED BY ANY PORTION OF THE WORK, BOTH DURING DEMCNND CONSTRUCTION, 16. WHERE DEMOLITION OCCURS ADJACENT TO EX-0 REMAIN, PATCH AND REPAIR TO MATCH ADJACENT CONDITIONS FORM APPEARANCE. 041 GENERAL NOTES leigNMENWIT. Imm 1. THE G.C. SHALL BE GOVERNED BY ALL CONDITIONS AS INDICATED IN THE CONSTRUCTIUON DRAWINGS FOR THE BUILDING. 2. THE G.C. SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE W/ ALL APPLICABLE SAFETY CODES. 3. THE G.C. SHALL INDEMNIFY AND HOLD THE OWNER /ARCHITECT /ENGINEER HARMLESS FOR INJURY OR DEATH TO PERSONS OR FOR DAMAGE TO PROPERTY CAUSED BY THE NEGLIGENCE OF THE CONTRACTOR, HIS AGENTS, EMPLOYEES, OR SUBCONTRACTORS. 4. ALL WORK SHALL BE APPLIED IN ACCORDANCE WITH THE MANUFACTURE'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 5. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME AS SIMILAR WORK. 6. WHERE DEVICES OR TIMES OR PARTS THEREOF ARE REFERRED TO IN SINGULAR, IT IS INTENDED THAT SUCH SHALL APPLY TO AS MANY SUCH DEVICES, ITEMS OR PARTS AS REQUIRED TO PROPERLY COMPLETE THE WORK. 7. THE G.C. SHALL BE RESPONSIBLE FOR THE SECURITY OF THE BUILDING AND SITE WHILE JOB IS IN PROGRESS, UNTIL THE JOB IS COMPLETED. 8. THE INTENT OF THESE DRAWINGS IS TO INDICATE THE SCOPE OF WORK REQUIRED IN ORDER TO CONSTRUCT COMPLETE AND FINISH SPACES READY FOR OCCUPANCY. THE CONTRACTOR AND SUB - CONTRACTORS ARE EXPECTED TO VISIT THE PROJECT SITE PRIOR TO SUBMISSION OF BIDS AND NOTIFY THE OWNER, PRIOR TO BIDDING, OF ANY DISCREPANCIES WITHIN THE DRAWINGS OR POSSIBLE CONFLICTS WHICH AFFECTS THE PROGRESS /SCOPE OF THIS PROJECT. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND FIELD CONDTIONS NOTIFYING THE OWNER OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE PROJECT. 9. THE CONTRACTOR SHALL ENSURE THAT THIS PROJECT AND ALL CONSTRUCTION ACTIVITIES RELATED THERETO, CONFORM WITH ALL LOCAL, REGIONAL, STATE, AND /OR FEDERAL REGULATIONS PERTAINING TO DISTURBING, DISPLACING, AND /OR REMOVAL OF ASBESTOS OR ASBESTOS CONTAINING MATERIALS. 10. ALL ITMES MARKED "N.I.C." ARE NOT PART OF THIS PROJECT. 11. ALL WORK SHALL BE GUARANTEED FOR A PERIOD OF (1) ONE YEAR AFTER COMPLETION, UNLESS OTHERWISE SPECIFIED, AND SHALL BE SO STATED IN CONTRACTOR'S WRITTEN PROPASAL AND AGREEMENT. ALL REPAIRS, CORRECTIONS, DISCREPANCIES, ECT. MUST BE MADE WITHOUT ANY ADDITIONAL COST TO THE OWNER, AND WITHIN (5) FIVE DAYS AFTER NOTICE IS GIVEN. B. CODES: 1. ALL WORK SHALL CONFORM TO THE APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF ANY CONFLICTS WHERE THE METHODS OR STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAW OR ORDINACES, THE LAWS OR ORDINANCES SHALL GOVERN. NOTIFY THE OWNER OR ARCHITECT OF ALL CONFLICTS. C. DIMENSIONS: 1. ALL INFORMATION SHOWN ON THE DRAWINS RELATIVE TO EXISTING CONDITIONS IS GIVIN AS THE BEST PRESENT KNOWLEDGE BUT, WITHOUT GUARNATEE OF ACCURACY. G.C. SHALL FIELD VERIFY EXISTING CONDITIONS AND DIMENSIONS AND SHALL NOTIFY THE ARCHITECT OF ANY DISCREPANCIES OR CONDITIONS ADVERELY AFFECTING THE DESIGN PRIOR TO PROCEEDING WITH THE ITEMS OF WORK AFFECTED. 2. DIMENSIONS ON THE PLANS ARE TYPICALLY TO THE FINISH FACE OF PARTITIONS OR TO THE CENTER LINE OF COLUMNS, U.N.O. ch, f J1 .01A 3. DO NOT SCALE DRAWINGS: 6` 7 )EPT. THE G.C. SHALL USE DIMENSIONS SHOWN ON THE DRAWINGS AND ACTUAL FIELD MEASUREMENT. NOTIFY THE ARCHITECT IF ANY DISCREPANCIES FOUND. D. FIRE PROTECTION: ; +.a:�:,, �,,E�, 1. NOT USED 2. NOT USED 3. NOT USED 4. BUILDING FIRE DETECTION / ALARM SYSTEM SHALL BE MODIFIED AS NECESSARY TO MAINTAIN DESIGN EFFECTIVENESS. G.C. SHALL PROVIDE SEPERATE PERMIT OR DOCUMENTATION AS REQUIRED TO COMPLY WITH FPC 603.2 E. GENERAL CONSTRUCTION: 1. THE G.C. SHALL INVESTIGATE AND VERIFY LOCATIONS OF STRUCTURAL, MECHANICAL, AND ELECTRICAL ELEMENTS AND OTHER EXISTING CONDITIONS PRIOR TO DRILLING OR CUTTING OF SLABS OR STRUCTURAL MEMEBERS. NOTIFY THE ARCHITECT OF ANY CONFLICTS PRIOR TO BEGINNING OF WORK. 2. IT SHALL BE THE RESPONSIBLITY OF THE G.C. TO LOCATE ALL EXISTING UTILITIES WETHER SHOWN HEREON OR NOT AND PROTECT THEM FROM DAMAGE. THE G.C. SHALL BEAR ALL EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUCTION WITH THE EXECUTION OF HIS /HER WORK 3. ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) CONDITION AT ALL TIMES 4. THE CONTRACTOR SHALL VERIFY ALL DOOR AND WINDOW ROUGH OPENING DIMENSIONS WITH DOOR AND WINDOW MANUFACTURES. 5. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. F. AMERICAN WITH DISABILITIES ACT: 1. ALL MOUNTING HEIGHTS AND CONSTRUCTION IS TO COMPY WITH THE FLORIDA ACCESIBILITY CODE & AMERICAN WITH DISABILITIES ACT. architect NORBERTO ROSENSTEIN ARCHITECT , INC. ARCHiECW - NTE M DM - PLANING 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL- infoarosensteinarchitect.com WEB: wwW.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2008 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOT BE REPRODUCED IN ANY FORM WITHOUT PERMISSION. DESIGNED N.R. DRAWN D.S. CHECKED N.R. I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. C � " 423 �L . �k e+ b. R E V I S 1 0 N S COMM. 2012 -37 DATE 8/8/2012 5701 SUNSET DR SUITE F06 ISIS WELLNESS NAILBAR SOUTH MIAMI FLORIDA, 33143 DEMOLITION P LA N A-2 �F 7