Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
12-303-035
711 N. FIELDER RD. f - -- _, �- - ,�.. :t, _._ - -- -.�— LD-1 . .. ARLINGTON, 1X 76012 . --y1- , , ., -- .... /JJ PH: 817 63 —5696 LJ/ _ — / I 1 FAX. (1317) 635 .5699. El I FL ol f --_- -� -v- . so -2 f � I , 1.. - - . ... _ . L I _ I I - A — w__ -- - IuECHAWAL CODED NOTES: 545 CFM I /I 1. PROVIDE NEW CARRIER CHILLED WATER AIR HANDLER U - NIT WITH ELECTRIC HEAT. BALANCE UNIT TO THE SCHEDULED C CFM. EXTEND N E W INSULATED 1 - 1/4 " COPPER CONDENSATE _._._ ... .... ....... _ _ I......_.e 23s TO THE MOP SINK. PROVIDE NEW SECONDARY DRAIN PAN I it II ii IL If II I {I { I I {{ {I »I �.... :: �$ , WITH HIGH LEVEL L - ........ _ _..... _ . .. _... _. ...... I �. , I ALARM. PROVIDE CONNECTION TO � .: ... - -- _ ..._._T.._....... .:..:._ _..... ... _.:...__._ . ..._ - - -..._ _ __ �. � THE I , -...- FIRE /SMOKE ALARM SYSTEM. BELIMO CONTROL VALVES AND ........ - _____ . . SENSORS FOR CHILLED WATER SHALL BE PURCHASE �.._ - . -:. _. D FROM ........................ �) I -.- ROTH BROTHERS, INC, 1 I� I I �---� f - - - -i 2. INSTALL ACCESS PANEL REQUIRED FOR PROPER SERVICING OF .AIR HANDLER. RR-1 EXACT LOCATIONS. TO BE APPROVED BY THE ARCHITECT. 3. EXTEND AND CONNECT NEW CHILLED WATER SUPPLY AND �. :. . . _......_ ' , I - - -- _ RETURN PIPING FROM AHU TO THE EXISTING SUPPLY AND _ _ -_-- -- -_. - -�- _ _ __ __ -- _ - ---- - -- - - - - -- -T -__ RETURN TURN PIPING. PROVIDE NEW SHUT OFF VALES. FIELD r I I C T- -r — , —� I VERIFY EXACT LOCATION AND REQUIREMENTS PRIOR TO BID. 1 z 4. PROVIDE NEW BUILDING STANDARD .THERMOSTAT WITH I 2 CWR , I 1 v REMOTE TEMPERATURE' SENSOR. EXTEND AND CONNECT CONTROL WIRING TO AHU CONTROLLER AS REQUIRED. so-t » i � I I R L' 780 cr1~t 2A CWR f 1 MOUNT THERMOSTAT AND SENSOR AT 48" AFF. VERIFY CONTROL WITH LANDLORD ALL --- ._._._ ..._ . _ ___ _ -_, _..... _:_:._.. - .:..�.._.. ___..... I r.,, ,, ,.., TR REQUIREMENTS PRIOR TO f 1...._._.._... I , BID. COORDINATE ALL BUILD E .._.__� > ) /!., ... I BUILDING E N R G Y MANAGEMENT I ......... .._...... CONNECTION REQUIREMENTS WITH LANDLORD PRIOR TO BID, ... ...... . ... ........... - .... 5. PROVIDE AND BALANCE NEW CEILING EXHAUST FAN AS W I� _ — - � .; - -;`. •.,- .,, •.., -.,,, SCHEDULED. EXTEND AND CONNECT NEW 8 "0 TO LANDLORD et• i t3 j, I EXHAUST DUCT.. FIELD VERIFY EXACT LOCATION PRIOR TO -- I I -' � - • I p \ :, � ,, �.,..;, I BEGINNING WORK.. d M -- %' f.. - -� �_`_>_<;f i 6. ELECTRICAL CONTRACTOR a 1 t) I , OSt! :: \ R SHALL FURNISH A NEW D Z ..._. _. � � so -t �. ,.:,�,, I g / Z. ' /�'' � I ADDRESSABLE DUCT MOUNTED SMOKE DETECTOR. ` W fY » 780 CFrt 9 / _ 16x14 UP I / �..� / � MECHANICAL CONTRACTOR SHALL INSTALL SMOKE Z 0 >O 24 r e I / .. eO a0 �eetf t cUtO 1 2 I I I j / ! \l,/ , I DETECTOR IN THE SUPPLY /RETURN AIR DUCT AND t= J I • 1 LL INTERLOCK SMOKE DETECTOR TO SHUT DOWN UNIT UPON I— a ., ALARM. ELECTRICAL CONTRACTOR SHALL WIRE DETECTOR - " I � j � , <... '� ,., �� ., "••. `w 7 //, �" ,�:' I C`/ TO RESPECTIVE .REMOTE ANNUNCIATOR AT CASHWRAP. to W Q - REFER TO ELECTRICAL a — _._.._ I I t-J TRI AL DRAWINGS FOR ADDITIONAL I ,_c_1 I I so –, INFORMATION. 1 / I 7. ROUTE NEW OUTSIDE - I— I - ,. --,.,,, -... ''., - ....., •_,. 1 I •. / � � %, � WITH MANUAI. DAMPER. TO 11.1 r S DE AIR DUCT sp -t LANDLORD PROVIDED CO C) / / _.._ D COMMON OUTSIDE ._AIR DUCT..MAIN: ---- = — ,, —z - — - - —� �` FIELD VERIFY EXACT LOCATION AND CONDITION PRIOR TO 1 ,- . , ,y,✓ ,,'" ; -' ,,' � I .•..,. '.•••.- '.,_, .. _ BID. 1 / ' •. -• _.. ._ - .. _... _ , GIN FIELD WITH EXISTING 8 .COORDINATE FINAL DUCT ROUTING SYSTEMS IN SPACE PRIOR TO DUCT FABRICATION. MOUNT Ir , DUCTWORK AS HIGH AS POSSIBLE. TYPICAL. W 9. GC TO UNDERCUT DOOR 1 FOR RETURN AIR FLOW. �. ' 10 ROUTE INSULATED COPPER CONDENSATE PIPING FROM AHU I TO MOP SINK. ROUTE CONDENSATE PIPE DOWN THRU _.._.. _. I ,• I - I - MINIMUM OF 16" PER _ I w I L __ ,I I FOOT THROUGHOUT. MAIN ( TAIN A M MUM SLOPE r 1..._._.... _... -.__ _.. O 11 PROVIDE TRANSFER GRILLE WITH SMOKE DAMPER IN WALL. i 1 /�,..... ... . {� LA.oAD NOTES: INSTALL AS HIGH AS POSSIBLE. COORDINATE WITH EC. lil � A. EXTERNALLY INSULATED FLEXIBLE DUCT, NOT TO XCEED 5' -0" IN LENGTH ,MAYBE USED FOR VERTICAL CONNECTIONS TO SUPPLY DIFFUSERS ONLY, 1 B. EXTERNAL FOIL WRAP INSULATION IS MANDATORY OR ALL SUPPLY AIR DUCT WORK IN CLOSED CEILING AREA �-• 6 M .2 M , 5 VERIFIED AND NOT IN LIEU OF INTERNAL DUCT LIN R. C. COORDINATE AHU LOCATION AND CONNECTIONS TO THE �......,. LANDLORD'S CW /HW PIPING WITH MALL OPERATIONS VERIFY r TO BE LOCATED IN A STRUCTURALLY APPROVED LOCATION °c, I ._> `, -� PRIOR TO BID. t7� , Q. HVAC DUCTWORK LEGEND SYMBOL DESCRIPTION RG RETURN GRILLE SID ® SUPPLY DIFFUSER LID LINEAR SLOT DIFFUSER T LOW VOLTAGE THERMOSTAT © LOW VOLTAGE SENSOR TIED TO THERMOSTAT MVID --i MANUAL VOLUME DAMPER SUPPLY DUCT WITH ELBOW TURNED UP SUPPLY DUCT WITH ELBOW TURNED DOWN RETURN OR EXHAUST DUCT, ELBOW TURNED UP RETURN OR EXHAUST DUCT, ELBOW TURNED DOWN BRANCH TAKE OFF DUCT WITH MANUAL DAMPER ELBOW WITH TURNING VANES 1" LINED DUCTWORK -- - -- EXISTING WORK TO REMAIN NEW WORK - ■ v ■ / IL