PLUMBING SPECIFICATIONS:
1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FLORIDA PLUMBING CODE
2007 AND ALL CODES ADOPTED BY IT.
2. PRIOR TO ORDERING, CONTRACTOR SHALL SUBMIT SHOP DRAWINGS
FOR ALL MATERIALS AND EQUIPMENT TO ENGINEER OF RECORD
FOR APPROVAL.
3. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT
ALL PLUMBING WORK IS FREE FROM DEFECTS OF MATERIALS AND
WORKMANSHIP, AND FOR A PERIOD OF ONE YEAR FROM DATE OF
FINAL ACCEPTANCE, REPAIR AND REPLACE ALL WORK WHICH BECOMES
DEFECTIVE AT NO EXPENSE TO THE OWNER
4. MATERIALS SHALL BE AS FOLLOWS:
A. DOMESTIC WATER PIPING — TYPE V COPPER WITH LEAD FREE SOLDER
B. SANITARY WASTE PIPING — SCH 40 NO HUB CAST IRON ABOVE GRADE.
SCH 40 PVC BELOW GRADE.
C. CONDENSATE DRAINAGE PIPING — TYPE 'L' COPPER IN 1" ARMAFLEX
D. VALVES — BRONZE NOBCO OR EQUAL AND RATED AT 125 PSI
5. ALL PLUMBING FIXTURES SHALL BE WATER SAVER PER CODE. FPC TABLE 604.4.
TYPE, COLOR AND TRIM TO BE SELECTED BY OWNER.
6. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS.
7. COMPLETE SYSTEM: FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN— SERVICE TEST
AFTER COMPLETION OF INSTALLATION.
a. FURNISH REQUIRED FLASHING TO ROOFING CONTRACTOR FOR PIPES
PENETRATING THE ROOF
9. ASSE 1010 CERTIFIED WATER HAMMER ARRESTORS SHALL BE ONLY APPROVED
MEANS OF CONTROLLING WATER HAMMER.
SYMBOL LEGEND
SYMBOL
DESCRIPTION
D4
GATE VALVE
BALL VALVE
P&T RELIEF VALVE
m}-
GATE VALVE IN RISER
Q
PIPE TURNS DOWN
0-
PIPE TURNS UP
-ilF-
UNION
40
HOSE BIBB
A�
WATER HAMMER ARRESTOR
LETTER DENOTES SIZE.
�(
WALL CLEAN OUT
1—ml
WATER METER
FLOOR CLEAN OUT
...--------
. ---. -- COLD WATER PIPING
-----------
--- - -- HOT WATER PIPING
SANITARY WASTE PIPING
-- — —
— — — — — — VENT PIPING
CONDENSATE DRAIN PIPE
—�—
PAN PAN DRAIN PIPE
- - --
PST -- PACT RELIEF PIPE
&� S ` tro
WL 1097
1 or 2 Hour Fire Rated Through
Penetration Firestop for Single
Metal Pipe through
Gypsum Walls using
FYRE- SHIELD.
F- Rating = 1 and 2 Hr.
T- Rating = 0 Hr.
CONC. SLAB
'—CONC. INSERT
``3/8" ALL THREAD ROD
PIPE I
--PIPE RING HANGER
PIPE HANGER NOT TO SCALE
1; 1" �, I r✓ (,1 l 111 1 i ,
3735 Green Rd.
Beachwood, OH, 44122
Drawing not to scale
1� Pre -Rated Gypsum Wallboard/Stud Wall Assembly
20 Metallic Pipe - A) Steel Pipe - E" diam. (or smaller) Sch. 40 (or heavier) steel pipe.
B) Iron Pipe - t" diam. (or smaller) cast or ductile iron pipe.
C) Conduit - 4" diam. (or smaller) EMT or rigid steel conduit.
D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing.
E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe.
The annular space shall be min. 1/4" to max. 5 1E" within the firestop system.
Q FYRE- SHIELD - Min. 1/2" thickness of sealant applied within opening. Additional sealant
to be installed such that it min. 1/4" crown is formed around the
penetrating item.
Project: The Tremco Products used above have been The above described assembly has been
................ __......._ tested in accordance with the following:
• ASTM FX 14 (UL 1479) Standard Test Method tested and is baste on both past re and shall -
1 OCatlOn, for Through Penetration FirestoPping. Ire l i performance d edgers,. Tremor shall not
Ire liable for any datnages, direct or pn-
sequential, resulting from use of tkis material
Installer. Date: 4/23/97 Drawing: TW -1097 or design. Trotneo shall only be responsible
for relslacine material found to be defective.
Signature: Approved by: J. Pitcole
I
PLAN KEY NOTES:
O EXISTING 2 -1/2" COLD WATER MAIN WITH
VALVE.
MAIN COLD WATER LINE TO REMAIN. DEMO
ALL OTHER HOT AND COLD WATER PIPING.
REMOVE ALL PLUMBING FIXTURES AND
FLOOR DRAINS FROM SPACE.
�l CAP OFF ALL PLUMBING STACKS AT FLOOR.
O DEMO ALL UNUSED VENT PIPING FROM
CEILING.
EXISTING LANDLORD DRAINAGE RISERS TO
REMAIN. TYPICAL.
O REMOVE EXISTING WALL HYDRANT AND
REPLACE WITH NEW IN NEW LOCATION..
O REMOVE EXISTING STORM DRAIN GRATE AND
PATCH FLOOR.
O EXISTING SANITARY OR STORM DRAINAGE
CLEANOUT TO REMAIN.
10 REMOVE EXISTING NATURAL GAS LINE. CAP
OFF AT CORRIDOR WALL.
11 REMOVE NATURAL GAS METER AND CAP
OFF GAS SERVICE TO THIS SPACE.
�IUn
T
W
,,,
\1
lP
N�
2
SCALE: 1 /8" = 1' -0"
11
rr!• !ro a i YYiYY !fi
! Y V V V • • V
• • N 4
6 V V
..�
• ♦. i f V
V V i
V N f V
• l v Vwv l
Y V i V • G k C! , i. • i
G N u •
V U V f V •
• U G l
V
i u�tli �V 1ifN (, N i
) THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED
:REWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE
'PLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF
_NZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE
:PRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSI
HENZ ENGINEERING INC.
I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE
LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION
OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL
DISCIPLINE CONTAINED IN THIS PUN, I FURTHER CERTIFY THAT THIS PLAN WAS
PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER
61G15- 111.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE
ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE
OF AUTHORIZATION #3110 TO PROVIDE THE ENGINEERING SERVICE.
WARNING! t t
MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG
ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND
LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL DAVID A. SCHMID , .E,•
COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL '
PROFESSSUNA ENGItJ�E�R No.5�J4�2
REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE STATE,OF FLORIDA I
PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. !
CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING r :� ' 1 I r, " 9. A
PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF 3 - PROJECT No.: 11098.00
REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. A ., tDATE: %,
archite
NORBERTO ROSENSTEIN
ARCHITECT , INC.
K0fMCTW - NrHU DE"- M-MM
126 S. FEDERAL HIGHWAY
SUITE # 202
DANIA BEACH, FLORIDA 33004
PH: (954) 922 -6551
FAX. (954) 922 -7388
EMAIL -info•rosensteinarchitect.com
WEB: www.rosensteinarchitect.com
STATE REC=. NO. .4RP P I6 & 74
NATL. RES. NO. &SI78
COPYRIGHT 0200'U
N0F3ERTO ROWNSTEIN ARCHITECT, INC.
ALL RIGHTS fQESERVED. THIS DOCUMFINT
OR PARTS THEIQEOF, MAY NOT 15M IWPFODUCED
IN ANY FOR1 WITHOUT PEF41155ION.
DESIGNED mlNplup,l
� ill�llllllg�m�hl) g�� � � �np
DS 11' Iyl.�illllll�� hli
i it I
I IY iG
DRAWN+ �Ili�l'I'il�il �ill���IIP'pp i�pJhb'�' °I,I�� �u��ld�l �IIgg
I
CHECKED mm III;;
'r�ll III II 'm
pAcJ ��I�^� °1,L� Ilulhaiolilitl uuun @�, °��� �
I HEREBY CERTIFY THAT THESE PLANS
WHERE PREPARED BY ME OR UNDER
MY SUPERVISION, AND TO THE BEST
OF MY KNOWLEDGE, COMPLY WITH ALL
APPLICABLE CODES.
I R E V I S 1 0 N S '
COMM. DATE
2011.37 8/1/2011
5701 SUNSET DR
SUITE A15A
WHITE BOX
SOUTH MIAMI
E1.ORDA, 33143
PLUMBING PLAN
P -1