11-910-014ALE a i M � N < I » a c . N PLUMBING SPECIFICATIONS: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH FLORIDA PLUMBING CODE 2007 AND ALL CODES ADOPTED BY IT. 2. PRIOR TO ORDERING, CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL MATERIALS AND EQUIPMENT TO ENGINEER OF RECORD FOR APPROVAL. 3. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING WORK IS FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP, AND FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE, REPAIR AND REPLACE ALL WORK WHICH BECOMES DEFECTIVE AT NO EXPENSE TO THE OWNER 4. MATERIALS SHALL BE AS FOLLOWS: A. DOMESTIC WATER PIPING — TYPE V COPPER WITH LEAD FREE SOLDER B. SANITARY WASTE PIPING — SCH 40 NO HUB CAST IRON ABOVE GRADE. SCH 40 PVC BELOW GRADE. C. CONDENSATE DRAINAGE PIPING — TYPE 'L' COPPER IN 1" ARMAFLEX D. VALVES — BRONZE NOBCO OR EQUAL AND RATED AT 125 PSI 5. ALL PLUMBING FIXTURES SHALL BE WATER SAVER PER CODE. FPC TABLE 604.4. TYPE, COLOR AND TRIM TO BE SELECTED BY OWNER. 6. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS. 7. COMPLETE SYSTEM: FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN— SERVICE TEST AFTER COMPLETION OF INSTALLATION. a. FURNISH REQUIRED FLASHING TO ROOFING CONTRACTOR FOR PIPES PENETRATING THE ROOF 9. ASSE 1010 CERTIFIED WATER HAMMER ARRESTORS SHALL BE ONLY APPROVED MEANS OF CONTROLLING WATER HAMMER. SYMBOL LEGEND SYMBOL DESCRIPTION D4 GATE VALVE BALL VALVE P&T RELIEF VALVE m}- GATE VALVE IN RISER Q PIPE TURNS DOWN 0- PIPE TURNS UP -ilF- UNION 40 HOSE BIBB A� WATER HAMMER ARRESTOR LETTER DENOTES SIZE. �( WALL CLEAN OUT 1—ml WATER METER FLOOR CLEAN OUT ...-------- . ---. -- COLD WATER PIPING ----------- --- - -- HOT WATER PIPING SANITARY WASTE PIPING -- — — — — — — — — VENT PIPING CONDENSATE DRAIN PIPE —�— PAN PAN DRAIN PIPE - - -- PST -- PACT RELIEF PIPE &� S ` tro WL 1097 1 or 2 Hour Fire Rated Through Penetration Firestop for Single Metal Pipe through Gypsum Walls using FYRE- SHIELD. F- Rating = 1 and 2 Hr. T- Rating = 0 Hr. CONC. SLAB '—CONC. INSERT ``3/8" ALL THREAD ROD PIPE I --PIPE RING HANGER PIPE HANGER NOT TO SCALE 1; 1" �, I r✓ (,1 l 111 1 i , 3735 Green Rd. Beachwood, OH, 44122 Drawing not to scale 1� Pre -Rated Gypsum Wallboard/Stud Wall Assembly 20 Metallic Pipe - A) Steel Pipe - E" diam. (or smaller) Sch. 40 (or heavier) steel pipe. B) Iron Pipe - t" diam. (or smaller) cast or ductile iron pipe. C) Conduit - 4" diam. (or smaller) EMT or rigid steel conduit. D) Copper Tubing - 4" diam. (or smaller) Type L (or heavier) copper tubing. E) Copper Pipe - 4" diam. (or smaller) Regular (or heavier) copper pipe. The annular space shall be min. 1/4" to max. 5 1E" within the firestop system. Q FYRE- SHIELD - Min. 1/2" thickness of sealant applied within opening. Additional sealant to be installed such that it min. 1/4" crown is formed around the penetrating item. Project: The Tremco Products used above have been The above described assembly has been ................ __......._ tested in accordance with the following: • ASTM FX 14 (UL 1479) Standard Test Method tested and is baste on both past re and shall - 1 OCatlOn, for Through Penetration FirestoPping. Ire l i performance d edgers,. Tremor shall not Ire liable for any datnages, direct or pn- sequential, resulting from use of tkis material Installer. Date: 4/23/97 Drawing: TW -1097 or design. Trotneo shall only be responsible for relslacine material found to be defective. Signature: Approved by: J. Pitcole I PLAN KEY NOTES: O EXISTING 2 -1/2" COLD WATER MAIN WITH VALVE. MAIN COLD WATER LINE TO REMAIN. DEMO ALL OTHER HOT AND COLD WATER PIPING. REMOVE ALL PLUMBING FIXTURES AND FLOOR DRAINS FROM SPACE. �l CAP OFF ALL PLUMBING STACKS AT FLOOR. O DEMO ALL UNUSED VENT PIPING FROM CEILING. EXISTING LANDLORD DRAINAGE RISERS TO REMAIN. TYPICAL. O REMOVE EXISTING WALL HYDRANT AND REPLACE WITH NEW IN NEW LOCATION.. O REMOVE EXISTING STORM DRAIN GRATE AND PATCH FLOOR. O EXISTING SANITARY OR STORM DRAINAGE CLEANOUT TO REMAIN. 10 REMOVE EXISTING NATURAL GAS LINE. CAP OFF AT CORRIDOR WALL. 11 REMOVE NATURAL GAS METER AND CAP OFF GAS SERVICE TO THIS SPACE. �IUn T W ,,, \1 lP N� 2 SCALE: 1 /8" = 1' -0" 11 rr!• !ro a i YYiYY !fi ! Y V V V • • V • • N 4 6 V V ..� • ♦. i f V V V i V N f V • l v Vwv l Y V i V • G k C! , i. • i G N u • V U V f V • • U G l V i u�tli �V 1ifN (, N i ) THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED :REWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE 'PLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF _NZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE :PRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSI HENZ ENGINEERING INC. I, DAVID A. SCHMIDT, P.E. #59492, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE MECHANICAL DISCIPLINE CONTAINED IN THIS PUN, I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 111.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHORIZATION #3110 TO PROVIDE THE ENGINEERING SERVICE. WARNING! t t MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL DAVID A. SCHMID , .E,• COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL ' PROFESSSUNA ENGItJ�E�R No.5�J4�2 REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE STATE,OF FLORIDA I PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. ! CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING r :� ' 1 I r, " 9. A PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF 3 - PROJECT No.: 11098.00 REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. A ., tDATE: %, archite NORBERTO ROSENSTEIN ARCHITECT , INC. K0fMCTW - NrHU DE"- M-MM 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX. (954) 922 -7388 EMAIL -info•rosensteinarchitect.com WEB: www.rosensteinarchitect.com STATE REC=. NO. .4RP P I6 & 74 NATL. RES. NO. &SI78 COPYRIGHT 0200'U N0F3ERTO ROWNSTEIN ARCHITECT, INC. ALL RIGHTS fQESERVED. THIS DOCUMFINT OR PARTS THEIQEOF, MAY NOT 15M IWPFODUCED IN ANY FOR1 WITHOUT PEF41155ION. DESIGNED mlNplup,l � ill�llllllg�m�hl) g�� � � �np DS 11' Iyl.�illllll�� hli i it I I IY iG DRAWN+ �Ili�l'I'il�il �ill���IIP'pp i�pJhb'�' °I,I�� �u��ld�l �IIgg I CHECKED mm III;; 'r�ll III II 'm pAcJ ��I�^� °1,L� Ilulhaiolilitl uuun @�, °��� � I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. I R E V I S 1 0 N S ' COMM. DATE 2011.37 8/1/2011 5701 SUNSET DR SUITE A15A WHITE BOX SOUTH MIAMI E1.ORDA, 33143 PLUMBING PLAN P -1 Q 1