Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11-354-054
t •••• V r V r r ,u V mow.. .. _ A. SCORE OF WORK • , • •. • s • G +•• V • V U • V • V 1, PROVIDE A COMPLETE AND OPERABLE FIRE PROTECTION SYSTEM AS IT APPLIES TO THE DEMISED PREMIFF, .' • • •' : + • + 1.1, THE FIRE PROTECTION SYSTEM SHALL BE DESIGNED FABRICATED AND INSTALLED BY A LICENSED OR NICET FIRE PROTECTION SYSTEM CONTRACTOR. 1.2, THE ENGINEER SHALL PROVIDE SPECIFICATIONS AND DIAGRAMS TO ALLOW LETTING OF A CONTRACT OF T14E FIRE PROTECTON PORTION OFD THE PROJECT. • • • • t • t • t • • 1.3. THE ENTIRE SYSTEM DESIGN, MATERIALS USED AND INSTALLATION SHALL COMPLY WITH FM GLOBAL ENGMEFRING,!'EQl11REElENTS!kS A MIhMUM.- Z 1.4. SIMON PROPERTY GROUP'S INSURANCE PLAN REVIEW GROUP CONTACT IS GLOBAL RISK CONSULTANTS, ItL,'CARY: (4i0)OZSII15.1, 2551..E.• •: Q SARATOGA STREET, GILBERT, AZ 85296. 1.5. REGIONAL PLAN SUBMITTALS SHALL BE MADE TO THE FOLLOWING OFFICES: • I""' s 1.5.1. AK, AZ, CA ,CT, IA, IL, IN, KY, MA, MD, ME, NH, NJ, NV, NY, OH, PA, UT, VA, WA, WI: V (� ATTN: DAVID COUGH Y•••• •••t` •••t• �r•• w sT 23 CUMBERLAND STREET :060., +' ; Z EMEND cc MANCHESTOR, CT 06040 • + " + (160)647 -0747 r•n• • ••••• • •tt • • • ••• • (R 1.5.2. AR, CO, KS, LA, M0, NE, NM, OK, TX: 1.5.3 FL, GA, NC, NC, SC TN: Z Z s ATTN: KIM NEWTON ATTN: LORI MEYERS Z 0 2590 WOODSIDE DRIVE 1003 REGENCY MANOR DRIVE ' HIGHLAND VILLAGE, TX 75077 BALLWIN, MO 63011 Q (636)891 -9052 2. WHERE APPLICABLE, THE CONTRACTOR SHALL CONTRACT THIS WORK WITH A LANDLORD APPROVED FIRE PROTECTION CONTRACTOR. ALL MATERIALS AND EQUIPMENT UNDER THIS SECTION SHALL BE NEW AND LISTED BY UNDERWRITERS LABORATORIES, INC. FOR FIRE PROTECTION SYSTEM O U.11 Z ' INSTALLATION. � r , 3. THE FIRE PROTECTION SYSTEM SHALL BE AS FOLLOWS: Q 3.1. NEW WET SPRINKLER FIRE PROTECTION SYSTEM FOR ALL AREAS OF THE RETAIL SPACE, PORTIONS THAT ARE UNHEATED OR EXPOSED TO W c , FREEZING TEMPERATURES SHALL BE PROVIDED WITH AN AUTOMATIC DRY PIPE SYSTEM COMPLYING WITH FM AND NFPA i3. U) D 3.2. COVERAGES SHALL BE IN ACCORDANCE WITH EXISTING CONDITIONS, NFPA 13, LOCAL CODES, LANDLORD'S CRITERIA, MALL INSURANCE CARRIER LLLJJJ AND LSDB:C'S STANDARDS AND SHALL INCLUDE: co LU ' 3.2.1. ALL PIPE TAPS, RISERS, LATERALS, BRANCHES, VALVES, HANGERS, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED. co cr r 3.2.2. PROVIDE PROFESSIONALLY DESIGNED AND SEALED DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS AS NEEDED LU Q INCLUDING ANY SEALS, PERMITS, FEES, AND CHARGES. 3.3. FIRE EXTINGUISHERS SHALL BE PROVIDED. REFER TO INSTALLATION SECTION OF THIS SPECIFICATION. a nx, 4. EXAMINE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DOCUMENTS TO PROPERLY SEQUENCE, COORDINATE, AND INTEGRATE THE x A i VARIOUS ELEMENTS OF THE FIRE PROTECTION SYSTEM WITH OTHER CONTRACTORS TO AVOID INTERFERENCES AND CONFRONTATIONS. LU 5. CONTRACTOR SHALL USE APPROVED INDUSTRY FIRE SPRINKLER STANDARDS FOR REUSING EXISTING FIRE SPRINKLER BRANCHES AND SUBMIT '0 CALCULATIONS TO THE LSD&C'S PROJECT MANAGER UPON REQUEST OR REWORK SYSTEM TO THE LSD&C PROJECT MANAGER'S SATISFACTION, 10 6. RELOCATION OF EXISTING MAINS, LATERALS, BRANCHES AND RISERS TO FACILITATE STORE DESIGN CRITERIA SHALL BE INCLUDED AS PART OF THIS WORK. 1. SHOP DRAWINGS AND DESIGN TYPICAL SPRINKLER 1. IN ACCORDANCE WITH THE PREVAILING STANDARDS, BUT IN NO LESS THAN THAT REQUIRED BY NFPA 13, THIS FIRE PROTECTION CONTRACTOR 11" HEAD LOCATION FOR 24' SHALL PREPARE COMPLETE CALCULATIONS AND SHOP DRAWINGS. SIX (6) COPIES SHALL BE SUBMITTED TO THE GENERAL CONTRACTOR AND T -BAR CEILING ADDITIONAL SETS AS REQUIRED TO THE PROPER CODE AUTHORITIES FOR APPROVAL (NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN = RECEIVED). 2. COPY OF THE LETTER OF APPROVAL FROM THE LANDLORD'S INSURANCE RATING BUREAU SHALL IE FORWARDED TO THE LANDLORD'S AGENT AND TO THE LSD&C PROJECT MANAGER. IN In 59 g W 2.1. A MINIMUM OF FIVE SETS OF SHOP DRAWINGS ALONG WITH HYDRAULIC CALCULATIONS (IF APPLICABLE) SHALL BE SUBMITTED TO GLOBAL wB1# _ RISK CONSULTANTS FOR APPROVAL. HYDRAULIC CALCULATIONS SHALL BE SUBMITTED REGARDLESS OF THE SCOPE OF WORK INVOLVED. H U e w K 2.2. FIVE SETS OF MATERIAL BROCHURES SHALL ALSO BE SUBMITTED TO GRC FOR REVIEW. BROCHURES SHALL BE LIMITED TO NEW SPRINKLER i?;, i a a HEADS, FLEXIBLE DROPS AND VALVES. PLANS SHALL INDICATE THE TYPE OF PIPING BEING UTILIZED WITH THE GAUGE INDICATED. 2:Ng xo ixN 18' 3. LISTED BELOW ARE MINIMUM REQUIREMENTS FOR SPRINKLER SYSTEM DESIGN AND INSTALLATION. SYSTEM SHALL BE HYDRAULICALLY DESIGNED: o ° 3 ut 9 12" 3.1. ORDINARY HAZARD, GROUP 2: PROVIDE A 0.20 GPM /SF PER 1,500 SQUARE FEET DENSITY WITH 1657 RATED I' ORIFICE SPRINKLER HEADS OR FOLLOW NFPA DENSITY /AREA CURVE FOR DENSITY COVERAGE. PROVIDE A MAXIMUM COVERAGE OF 130 SQUARE FEET PER HEAD. o W o o 3.1.1. MINIMUM SPACING SHALL BE 70 SQUARE FEET PER HEAD AND SPACING SHOULD NOT EXCEED 100 SF FOR DENSITIES OVER 0.25 W o w _ GPM /SF. e= F Ea A TYPICAL 24'x24 "CEILING TILE TYPICAL x24 "CEILING TILE 3.1,2. FM GLOBAL REQUIRED DENSITY WILL BE 0.15 GPM /SF OVER THE MOST HYDRAULICALLY REMOTE 2500 SF USING I" ORIFICE, 165 I .1: IR ��SXE E H° " DEGREE RATED HEADS. HEAD SPACING SHOULD NOT EXCEED 130SF. OPTIMUM SPRINKLER OPERATING AREA SHOULD BE 300SF UNLESS # _0 On g ° SPECIFIC APPROVAL IS GIVEN OTHERWISE FOR SPECIAL OCCUPANCIES. THE MOST REMOTE AREA SHOULD HAVE THE DIMENSIONS r =• . `"_' TYPICAL SP LER w K ° - • M 12" 12" PARALLEL TO THE BRANCH LINE OF AT LEAST 1.4 TIMES THE SQUARE -FOOT OF THE AREA. THE DENSITY DESIGN SHOULD CONFORM TO HEAD LING R THE MOST STRINGENT OF FM GLOBAL OR NFPA 13, ORDINARY HAZARD GROUP TWO OCCUPANCY FOR RETAIL /COMMON /OFFICE AND T- CEILING MECHANICAL EQUIPMENT AREAS. C�� - Yw =Wr 3.2. MAXIMUM HEAD SPACING: 15FT.^ -+_ 3.3. SPRINKLERS SHALL BE TESTED FOR A MINIMUM OF 2 HOURS AT 200 PSI. ° ; r "� 9 • " 3.4. DESIGN CALCULATIONS OF INSIDE PIPE SHALL USE C =100 FOR DRY AND C =120 FOR WET SYSTEMS. C. SPRINKLER HEADS : 8'M mo o 1. ALL SPRINKLER HEADS SHALL BE NEW (EXISTING HEADS IN EXISTING LSD&C STORES ARE NOT TO BE REPLACED UNLESS NOTED OTHERWISE), _ • K ak W h ° U.L AND F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY AUTOMATIC SPRINKLER, GRINNELL, RELIABLE, OR VIKING. N �- O 12" 12" 2. ALL SPRINKLER HEADS SHALL ME RATED AS FOLLOWS OR AS REQUIRED BY LOCAL CODES: C7 rf 2.1. STORAGE AREAS OR MEZZANINES: 200'F- 225'F, `-L 2.2. SALES AREA: 150'F -17U'F OR 200'F -225'F AS NOTED ON PLANS J 3. ALL SPRINKLER HEADS SHALL BE AS FOLLOWS: TYPICAL 24'x24'CEIUNG TILE ( I) ) TYPICAL 48 "x24'CEIUNG TILE (FAUX 24'x24') 3.1. MANUFACTURER 3.1.1. SALES AREA: BASE BID SHALL INCLUDE HEADS MANUFACTURED BY RELIABLE WITH ALTERNATE BIDS BASED ON VIKING MICROMATIC MODEL M OR GRINNELL MODEL F972 AND SHALL BE APPROVED BY THE LSD&C PROJECT MANAGER PRIOR TO ORDERING AND SPRINKLER 3.1.2, INSTALLATION. FIRE HEAD DETAILS NTS NON -SALES _IREI: ROUGH BRASS FINISH AS MANUFACTURED BY AUTOMATIC SPRINKLER, STAR, RELIABLE, GRINNELL OR VIKING OODF023HOSPHD SPRINKLER COMPANY ONLY, 3.2. HEAD TYPE F DROP NIPPLE 3.2.1. .ALES AREA: REFER TO LEGEND ON FIRE SPRINKLER HEAD PLAN FOR HEAD TYPE REQUIREMENTS IN SALES AREA. Z w DROP NIPPLE W O 3 3.2.2. NON -SALES AREA w P O 3.2.2.1. GYPSUM BOARD OR LAY -IN CEILING: RECESSED V t a 3.2.2.2. WITHOUT CEILING: PENDANT Q Y W 3.2.2.3. OPEN TO STRUCTURE: UPRIGHT -� REDUCER REDUCER 3.2.2.4. HEADS MOUNTED UNDER I FEET ABOVE FINISHED FLOOR SHALL BE CONCEALED OR BE PROVIDED WITH WIRE GUARDS. a d � SUSPENDED CEILING SPRINKLER HEAD 4. ALL SALES AREA SPRINKLER HEADS INCLUDING TRIM AND COVER SHALL HAVE FACTORY APPLIED FINISH. REFER TO LEGEND ON FIRE SPRINKLER SUSPENDED CEILING HEAD PLAN FOR FINISH REQUIREMENTS. 0 rn W Wo0) 5. ALL SPRINKLER HEADS ON THE MALL SIDE OF TENANT'S STOREFRONT ENCLOSURE, IF ANY, SHALL MATCH LANDLORD'S TYPE. U) Z M D. PIPING, FITTINGS B VALVES Z ESCUTCHEON O POP -OUT COVER M n SPRINKLER HEAD FINISH TO MATCH 1. SCHEDULE 40 BLACK STEEL: ASTM A -53 WELDED AND SEAMLESS, ANSI 1- 36 -10 -70 FOR WROUGHT STEEL PIPE. U) O CEILING 2. CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER, SCREWED OR CAST IRON FLANGED JOINTS FOR PIPES RECESSED HEAD CONCEALED HEAD LARGER THAN 2 INCHES. FITTING SHALL BE APPROVED FOR 175 PSI WORKING PRESSURE. ZO CIO W 1''> 3. GALVANIZED OR BLACK MALLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND SMALLER. ` > M fA DROP NIPPLE 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE WHERE APPROVED BY LOCAL CODE AND LANDLORD. ©` L+- a U 5. APPROVED FM LIGHTWALL PIPING WITH ROLL GROOVES MAY BE USED IN SIZES LARGER THAN 2 INCHES, EXCEPT WHERE PIPE IS SUBJECT TO O� O I J U Ld �- SPRINKLER HEAD PHYSICAL DAMAGE. Z Z o t >- m -�- - REDUCER 6. ALL HANGERS SHALL CONFORM TO FM GLOBAL GUIDELINES, STRUCTURAL STEEL HEADERS SHALL BE INSTALLED FOR SUPPORTING CROSS MAIN ui O z 1-- a HANGERS WHERE THE MAIN 15 NOT DIRECTLY BELOW A STRUCTURAL MEMBER. W J = L;j Z L) LU,LUL rL_-i 7. CAST IRON WALL PLATES SHALL BE PROVIDED ON EXPOSED PIPING WHERE PIPE PASSES THROUGH WALLS, PARTITIONS, CEILINGS, ETC., SECURED O = O t O O N 0 SPRINKLER HEAD 0 N d O U LJ 1n 4- REDUCER BY SETSCREWS. d UU 1�_ In N In N O Lpi » -C A. VALVES SHALL BE FM GLOBAL APPROVED AND RATED 175 PSI MINIMUM. REVISIONS' o E. INSTALLATION REQUIRED IY: ►ATE z 2 `o ►-- ° DROP NIPPLE 04/01/11 � 0 1. AFIRE PROTECTION SYSTEM TAP IS NORMALLY FURNISHED BY THE LANDLORD, VERIFY IN FIELD PRIOR TQ BID. rn w F= 1.1. WHENEVER AN EXISTING SPRINKLER SYSTEM IS BEING RENOVATED, THE INTEGRITY AND RELIABILITY OF THE EXISTING SYSTEM SHALL BE MAINTAINED. o 1.2. ORIGINAL SPRINKLER SHOP DRAWINGS SHALL BE ACQUIRED THROUGH THE MALL MANAGER /PROJECT MANAGER; HOWEVER, THE SPRINKLER CONTRACTOR SHALL VERIFY THE EXISTING SPRINKLER SYSTEM IN THE FIELD AND SHALL COORDINATE WITH AND SHOW DISCREPANCIES BETWEEN PENDANT HEAD UPRIGHT HEAD THE ORIGINAL SHOP DRAWINGS AND FIELD CONDITIONS IN THE RENOVATED SHOP DRAWINGS. 2. INSTALLATION SHALL INCLUDE TESTING THE BUILDING SYSTEM PRIOR TO CONNECTING TO MALL SPRINKLER SYSTEM. TESTING SHALL BE APPROVED BY INITS THE FIRE SPRINKLER HEAD DETAILS OODF023GOSPHD DEPARTMENT AND THE EMIR ED PREMIS SEIISATESTED ND READY F OR SERVICE. LANDLORD'S SPRINKLER MAIN WILL NOT BE MADE UNTIL THE k,MM7�i`I` 3. SPRINKLER HEAD SPACING SHALL COMPLY WITH ORDINARY HAZARD, GROUP 2. 4'1 :. r' 4. SYSTEM SHALL COMPLY WITH THE MOST STRINGENT OF THESE SPECIFICATIONS, THE LANDLORD'S DESIGN CRITERIA OR LOCAL CODES WITH PIPE • IDICAT s No REVISI•N to nIS sir SIZING BEING BASED ON NFPA ORDINARY HAZARD, GROUP 2 AND COMPLY WITH NFPA 13 AND FM GLOBAL DATA SHEETS 2 -8N LATEST EDITIONS. ( ,� jr 5, ALL SPRINKLER LINES SHALL BE CONCEALED AND MOUNTED AS HIGH AS IS PRACTICAL, AVOIDING INTERFERENCE WITH LIGHTS, DUCTS, PIPES, O S H R E M S H O C K t.i tti n+ pCi STORAGE DECK, ETC. .S:r. Shremshock Engineering, Inc. n; li. E „T ;{ 6. FIRE PROTECTION CONTRACTOR SHALL PREPARE COORDINATED SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL SPRINKLER HEADS, SPRINKLER 1? q1 1�- 6130S. Sunbury RM. Westerville, OH 43041 LINES, LIGHTS, DIFFUSERS, GRILLES AND REGISTERS PRIOR TO INSTALLATION. t: 614 545 4550 1: 614 545 4555 7. RELOCATE ALL MAINS AND BRANCHES INTERFERING WITH CEILING HEIGHTS, EQUIPMENT AND MAJOR COMPONENTS, INCLUSIVE OF ADJACENT TENANTS JEROMY T. PERRY, 164321 AND MALL COMMON AREAS. REMOVE ALL UNUSED PIPING. CERTIFICATE %UWA� f�.j AT ION FIRE PROTECTION RESPONSIBILITY SCHEDULE ITEM FURNISHED NY INSTALLED BY RE -USE EXISTING N/A REMARKS Esotc VENDOR LANDLORD CONTR. LANDLORD CONTR. OTHER SPRINKLER PIPING FPC FPC OFFICIAL PRIOR TO ROUGH -IN. SPRINKLER HEADS 10. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS ST�''I C OF FPC FPC / �• ORID, �� u PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OF REPLACEMENT OF DAMAGES SHALL BE AT THIS FIRE EXTINGUISHERS FPC FPC "SPRINKLER U , 111 b DATE I 11 8/11 AS- BUILTS DRAWINGS 1 PROPERLY COMPLETED AND SIGNED CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, DESIGNED �Y: BJD FPC AUTHORITIES HAVING JURISDICTION, TENANT'S ARCHITECT, INSURANCE REPRESENTATIVE, PROJECT OFFICE AND THE LSD&C PROJECT MANAGER. CERTIFICATES OF APPROVAL FROM THE AUTHORITY HAVING JURISDICTION SHALL BE FORWARDED TO SPG. DRAWN NY: BJD CHECKED BY' JTP 12. PROVIDE VALVED DRAIN WITH HOSE THREAD AT ALL LOW POINTS OR TRAPS IN SPRINKLER PIPING. IDENTIFY DRAIN VALVES IF ABOVE HARD CEILINGS WITH A SUITABLE CEILING MARKER AND PROVIDE ARCHITECT APPROVED METHOD FOR ACCESS AS REQUIRED. FIRE PROTECTION,, 13. COORDINATE SPRINKLER WORK WITH FIRE /ALARM CONTRACTOR WHERE THERE ARE FLOW AND TAMPER SWITCHES AND ALARM REQUIREMENTS. SPECIFICATIONS 14. SPRINKLER SYSTEM SHALL BE INTERFACED WITH BUILDING FIRE /LIFE SAFETY AND SMOKE EXHAUST SYSTEM IF REQUIRED. REFER TO LANDLORD TENANT CRITERIA AND REQUIREMENTS. AND D D E T A I L S 15. FURNISH AND INSTALL 10LL TYPE 'ABC' FIRE EXTINGUISHERS WITH CABINETS IF REQUIRED, AND AT LEAST A '2A1 OBC' RATED EXTINGUISHER. �1 G F� L a7 LOCATIONS ARE TO BE ESTABLISHED IN THE FIELD BY THE LSD&C PROJECT MANAGER AND THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DRAWING NUMBER' DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. `� `% 2 NTS NTS o 3 FIRE PROT. RESPONSIBILITY SCHEDULE 00*023FOscHD B FIRE PROTECTION SPECIFICATIONS OONF023AIISPR A 8. FASTENING AND /OR SUSPENSION DEVICES MUST BE ATTACHED TO THE BUILDING STRUCTURE ONLY. SUPPORT SHALL BE FROM THE TOP OF ANY OAR JOIST OR AS DIRECTED BY THE LANDLORD OR THE BUILDING STRUCTURAL ENGINEER. PROVIDE FOR SEISMIC BRACING WHERE REQUIRED BY LOCAL 12708 7�� �OM..wr..P�� CODES OR FM GLOBAL. I. FURNISH AND INSTALL A VALVED TEST CONNECTIONS IN A ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM AS REQUIRED OR REQUESTED BY THE * NO. 64321 "- MALL, LOCAL INSPECTOR, OR INSURANCE CARRIER - COORDINATE LOCATION WITH THE LSDAC PROJECT MANAGER AND LOCAL FIRE PROTECTION OFFICIAL PRIOR TO ROUGH -IN. 10. WHEN COMPLETED, THE ENTIRE FIRE PROTECTION PIPING SYSTEM SHALL BE HYDROSTATICALLY TESTED AS REQUIRED BY THE RULES AND REGULATIONS ST�''I C OF OF THE AUTHORITIES HAVING JURISDICTION ON GLOBAL RISK CONSULTANTS. SYSTEM SHALL SHOW NO SIGNS OF LEAKAGE OR OTHER DEFECTS. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO THE WORK OF THE OTHER CONTRACTORS OR TO THE BUILDING, OR TO ITS CONTENTS, / �• ORID, �� u PEOPLE, ETC., CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLED BY HIM. ALL REPAIRS OF REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. COMPLETELY FLUSH THE SYSTEM UNTIL DISCHARGE SHOWS NO DISCOLORATION. "SPRINKLER U , 111 b DATE I 11 8/11 1 PROPERLY COMPLETED AND SIGNED CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE FURNISHED TO THE LANDLORD, DESIGNED �Y: BJD AUTHORITIES HAVING JURISDICTION, TENANT'S ARCHITECT, INSURANCE REPRESENTATIVE, PROJECT OFFICE AND THE LSD&C PROJECT MANAGER. CERTIFICATES OF APPROVAL FROM THE AUTHORITY HAVING JURISDICTION SHALL BE FORWARDED TO SPG. DRAWN NY: BJD CHECKED BY' JTP 12. PROVIDE VALVED DRAIN WITH HOSE THREAD AT ALL LOW POINTS OR TRAPS IN SPRINKLER PIPING. IDENTIFY DRAIN VALVES IF ABOVE HARD CEILINGS WITH A SUITABLE CEILING MARKER AND PROVIDE ARCHITECT APPROVED METHOD FOR ACCESS AS REQUIRED. FIRE PROTECTION,, 13. COORDINATE SPRINKLER WORK WITH FIRE /ALARM CONTRACTOR WHERE THERE ARE FLOW AND TAMPER SWITCHES AND ALARM REQUIREMENTS. SPECIFICATIONS 14. SPRINKLER SYSTEM SHALL BE INTERFACED WITH BUILDING FIRE /LIFE SAFETY AND SMOKE EXHAUST SYSTEM IF REQUIRED. REFER TO LANDLORD TENANT CRITERIA AND REQUIREMENTS. AND D D E T A I L S 15. FURNISH AND INSTALL 10LL TYPE 'ABC' FIRE EXTINGUISHERS WITH CABINETS IF REQUIRED, AND AT LEAST A '2A1 OBC' RATED EXTINGUISHER. �1 G F� L a7 LOCATIONS ARE TO BE ESTABLISHED IN THE FIELD BY THE LSD&C PROJECT MANAGER AND THE LOCAL FIRE PROTECTION OFFICIAL. MAXIMUM TRAVEL DRAWING NUMBER' DISTANCE BETWEEN EXTINGUISHERS SHALL BE 75 FEET OR LESS AS REQUIRED BY LOCAL CODES. `� `% 2 NTS NTS o 3 FIRE PROT. RESPONSIBILITY SCHEDULE 00*023FOscHD B FIRE PROTECTION SPECIFICATIONS OONF023AIISPR A