ELECTRICAL RESPONSIBILITY SCHEDULE
°W "• v
1. REFER TO LANDLORD'S SPECIFICATIONS AND TENANT DESIGN CRITERIA FOR NECESSARY INFORMATION AND COORDINATION !K!11f bTYY:n 'fRADES. +
COORDINATE ALL WORK WITH ALL TRADES INCLUDING PUT NOT LIMITED TO MECHANICAL, PLUMBING, FIRE PROTECTION, AND STRUCTURAL
CONTRACTORS. INSTALL ALL WORK TO CLEAR NEW AND EXISTING ARCHITECTURAL AND STRUCTURAL MEMBERS. NO ITEM SUCH AS PIPE, DUCT,
�•••�
• • • i i "'
ITEM
FURNISHED BY
INSTALLED OR PERFORMED BY
RE -USE
EXISTING
N/A
REMARKS
LA
CONVR.
ESDtc
VENDOR
LANDLORD
CONT'R. OTHER
ELECTRICAL SERVICE /DISTRIBUTION
ETC. IS TO BE IN CONTACT WITH ANY EQUIPMENT. • • W C,
2. ANY DISCREPANCY BETWEEN ESD&C DRAWINGS AND TENANT CRITERIA, ESD&C DRAWINGS SHALL TAKE PRECEDENCE. : W • i °
• i • • 4
3. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL INSTALLED ITEMS AND LOCATIONS ARE NOT EXACTLY PLACED AND •;RE••
NOT TO BE SCALED. ALL CONDUITS SHALL BE RUN TO SUIT CONDITIONS IN THE FIELD. CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY ON THESE
PUNS AND DO NOT NECESSARY REFLECT THE EXACT CONDUIT LOCATIONS. ALL CONDUITS SHALL BE RUN INSIDE SHELL (?F,a'JILDING AY7-UNDER
i
INSULATED CEILING TO AVOID HIGH AMBIENT TEMPERATURE CONDITION. "
W ° � • • •
� „i ,r • � •
4. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO SCHEDULE ALL ELECTRICAL INSPECTIONS REQUIRED BY THe PLLUIK DL�FAI MEAT '
AND SERVING UTILITIES, AND EACH CONTRACTOR SHALL BE RESPONSIBLE FOR HIS OR HER PERMITS AND INSPECTION FEES.
5. BEFORE COMMENCING ANY WORK, CONTRACTORS SHALL REVIEW THE LATEST NATIONAL, STATE, AND LOCAL CODE REQUIREMENTS, INCLUDING
LANDLORD CRITERIA, AND PERFORM THE WORK IN STRICT ACCORDANCE WITH THESE, IN CASE OF CONFLICT, THE STRICTER REQUIREMENTS WILL
PREVAIL
G. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING HIS OR HER BID. FOR THE
PURPOSE OF SURVEYING EXISTING CONDITIONS, WHICH MAY AFFECT THE WORK TO BE DONE UNDER THIS SECTION, ANY DISCREPANCIES SHALL BE
IMMEDIATELY REPORTED TO THE GENERAL CONTRACTOR, ESD&C, OR THE LANDLORD'S FIELD REPRESENTATIVE FOR CLARIFICATION.
7. AFTER BID, ANY QUESTIONS RELATING TO SPECIFIC M, E. OR P ISSUES ARE TO BE DIRECTED AS RFI'S THROUGH THE ESO&C PROJECT MANAGER.
8. SHOULD THE SPACE HAVE BEEN INACCESSIBLE FOR INSPECTION, CONTRACTOR MUST INDICATE SO ON HIS OR HER DID.
!. NO ADDITIONAL COMPENSATION SHALL BE MADE FOR ANY CHANGE ORDERS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOISITE AND /OR
PREDETERMINE ALL EXISTING CONDITIONS BEFORE SUBMITTING HIS OR HER BID.
10. THE CONTRACTOR, WITHIN FIFTEEN (15) DAYS OF THE AWARD OF THE CONTRACT, SHALL SUBMIT TO THE OWNER, SIX (6) COPIES OF A COMPLETE
LIST OF MATERIALS AND EQUIPMENT PROPOSED FOR THE JOB INCLUDING ALL DATA PART NUMBERS RATING CAPACITY SIZE DIMENSIONS
ELECTRICAL DATA, GRADE, MANUFACTURER, AND ANY OTHER DESCRIPTIVE DATA FDR ALL EgUIPMENT� OR SYSTEMS THAT DEVIATE FROM SP�ECIFIEp
ITEMS. ANY DELAYS OR COSTS DUE TO THESE DEVIATIONS, WILL BE THE RESPONSIBILITY OF THE CONTRACTOR.
11. CONTRACTOR SHALL REMOVE ALL ABANDONED WIRING WHICH IS NOT TO BE REUSED. ABANDONED WIRING SHALL BE DISCONNECTED AND REMOVED
FROM CONDUIT OR RACEWAY. AS -IS PRACTICAL, CONDUIT AND /OR RACEWAYS SHALL REMAIN WITH PULL STRING AND CAPPED. CONTRACTOR SHALL
BE RESPONSIBLE FOR THE DISPOSAL OF ALL UNUSED OR ABANDONED MATERIALS AND EQUIPMENT AND ITS REMOVAL OFF THE TENANT'S AND
•
•
• E 0
• •�rji • F-
V 0 n • 4
�� r Z = '"'°
• �/ � �
• ;;
..;
rA
v
Z Z
Z Q
Z
J
a
Z 4• : .
W / rl f
�✓
_ r
Q Uj
W
Q ;
'A W;"
L1G ri
=`
W 0 >4
CL ~
a•.,
X ?
W = a5 �µ
MAIN OVER CURRENT DEVICE
•
PRIO VERIFY
FIBOR To BID
METER IN LANDLORD'S OR TENANT'S SPACE
(VERIFY W/ POWER PUNS, RISER)
FIELD VERIFY
PRIOR TO BID
C /T'S AND CABINET IN LANDLORD'S OR
TENANT'S SPACE (VERIFY W/ POWER PUNS,
RISER
•
FIELD VERIFY
PMDR TO BIO
SERVICE ENTRANCE CONDUIT(S) TO LEASE SPACE
•
E.C. to EXTEND
CONDUIT PER EDS.1
SERVICE ENTRANCE FEEDER(S) TO LEASE SPACE
•
E.C. To EXTEND
CONDUCTORS PER
I.F.S. ENCLOSURE (SWITCHGEAR ASSEMBLY)
IF
EC
277/490 volr PANEL
IF
IF
INSTALLED IN FACTORY
STEP DOWN LINE TRANSFORMER t MOUNTING
ACCESSORIES
IF
IF
INSTALLED IN FACTORY
120/208 VOLT PANEL(S)
IF
IF
INSTALLED IN FACTORY
ONTRO�REAKER SYSTEM FOR LIGHTING
IF
IF
INSTALLED IN FACTORY
LIGHTING CONTROLLER WITH POWER SUPPLY
AND OVERRIDE STATION
EMS
IF
INSTALLED IN FACTO
BREAKER LOCKS
IF
IF
AS REQUIRED BY
ENGINEER
MECHANICAL / PLUMBING EQUIPMENT COORDINATION
LANDLORD'S PREMISES.
12. OWNER RESERVES THE RIGHT TO HAVE CONSTRUCTION REVIEWED BY AN OUTSIDE CONSULTANT PRIOR TO ACCEPTANCE OF THE PROJECT.
POWER WIRING AND CONDUIT / PULL STRING TO
ALL HVAC EQUIPMENT
EC
EC
13. EACH CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP RELATED TO HIS OR HER WORK FOR A MINIMUM PERIOD OF ONE YEAR
FROM THE DATE WHICH THE OWNER ACCEPTS THE PROJECT. THE CONTRACTOR, AT NO ADDITIONAL COST TO THE OWNER OR TENANT, SHALL
CORRECT ANY DEFECTS IN MATERIALS OR WORKMANSHIP DURING THIS GUARANTEE PERIOD.
ROOF TOP UNIT -
DISCONNECT SWITCH
•
HVAC UNIT -
WEATHERPROOF GFI SERVICE REC.
•
WIRED BY EC
14. EACH CONTRACTOR SHALL BE RESPONSIBLE AND ENSURE A CLEAN INSTALLATION, ESPECIALLY IN EXPOSED CEILING AREAS. THE FINAL
APPROVAL OF THIS WORK WILL BE ISSUED BY ESD&C PROJECT MANAGER.
: K
w �_
'� "
a _° W.-Oz. ° s
Z O # y W
� ° � � E1 1:4 •
c W 3
N s. IL 7 6 j� Ir
`� _ > s' w a
„�N�° ��w�r .'40m. 9
i i �{
€ # ° E w
Sw�=� � ��`���
t3 N p S
_ €88RI irf
, � s L E v c°, E' k'
"� � o -
- W U N o t2 :
: ! •
92 M42'3 W
c , t GI S _ z
w K ° 12
_ r E' = E; ° " � W
.,,I<� �����a �� 5
WNW w
SI
=3W� °�WZ� +�-
`FAr iE`w`%° W A
LOW VOLTAGE WIRING TO BE INSTALLED IN CONDUIT AS REQUIRED NY
JURISDICTION OR LANDLORD.
❑ LOW VOLTAGE WIRING TO BE INSTALLED IN CONDUIT DUE TO HARD CEILING.
NOTE:
• CONTRACTOR SHALL FIELD VERIFY LOW VOLTAGE WIRING IN CONDUIT PRIOR TO BID,
• WIRING MUST BE PLENUM RATED DUE TO CEILING PLENUM RETURN.
15. PROVIDE THREE SETS OF "AS- BUILT" DRAWINGS AND TWO BOUND SETS OF ALL OPERATIONS MANUALS, DIAGRAMS, SERVICE CONTRACTS, AND
GUARANTEES TO ESD&C PRECEDENT TO FINAL PAYMENT. A REPORT PREPARED NY AN INDEPENDENT AIR BALANCE CONTRACTOR, HIRED NY GC,
MUST BE INCLUDED IN THE CLOSEOUT PACKAGE,
16. THE ABBREVIATION "ESD&C" WHEREVER IT APPEARS IN THESE ELECTRICAL DRAWINGS SHALL REFER TO "EXPRESS BRANDS STORE DESIGN AND
CONSTRUCTION`.
17. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS
RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF HIS OR HER SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS
THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS.
11. THESE PUNS MAY BE USED FOR CONSTRUCTION ONLY AFTER APPROVAL IS OBTAINED FROM THE BUILDING DEPARTMENT ELECTRICAL PLAN CHECK
DIVISION AND THAT DIVISIONS STAMPED APPROVAL AND AUTHORIZED SIGNATURE APPEAR ON THE PUNS.
19. REFER TO ARCHITECTURAL DRAWINGS FOR DEMOLITION WORK.
20. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATION.
21. DESIGN AND CIRCUITRY MAY BE BASED ON AS -BUILT DRAWINGS. GC AND ELECTRICAL CONTRACTOR SHALL VERIFY ACCURACY OF AS- BUILT�;�
DRAWINGS. IN CASE OF DISCREPANCY, ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONDUITS, CONDUCTORS, BOXES,
MISCELLANEOUS FITTINGS, ETC. FOR A COMPLETE AND OPERABLE SYSTEM FOR HOME RUNS SHOWN. (RANCH CIRCUIT INSTALLATION SHALL COMPLY
WITH SPECIFICATIONS AND LATEST N.E.C.
22. WHERE PRACTICAL, AND WHERE CONDUIT CONDITION WARRANTS, CONTRACTOR MAY REUSE APPROPRIATE EXISTING CONDUIT SYSTEM. HOWEVER, IT
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO CORRECT ANY AND ALL EXISTING CODE VIOLATIONS IN CONDUIT SYSTEMS TO BE REUSED.
CONTRACTOR MUST OBTAIN THE ESD&C PROJECT MANAGER'S PERMISSION IN WRITING.
AIR HANDLING UNIT CW AND/OR HW, CW WITH
ELECTRIC HEAT) -
DISCONNECT SWITCH FAN CONTACTS
AC
AC
AIR HANDLING UNIT (DX SPLIT) - DISCONNECT
SWITCH /FAN CONTACTS
•
CONDENSING UNIT (DX SPLIT) -
DISCONNECT SWITCH
•
CONDENSING UNIT (DX SPLIT) -
WEATHERPROOF GFI SERVICE REC.
+
FAN POWERED vJAV / vAV SYSTEM (WITH OR
WITHOUT ELECTRIC HEAT) - DISCONNECT
SWITCH
•
WATER SOURCE HEAT PUMP -
DISCONNECT SWITCH
•
TOILET EXHAUST FANS (FRACTIONAL HP) WITH
DISCONNECT SWITCH
LD
MC
ELECTRONIC CONTROL DAMPERS -
DISCONNECT SWITCH
EC
EC
DUCT
•
LOW VOLTAGE SYSTEMS
N
O
Y N O
a-
� �
23. IF APPLICABLE, RECONNECT, COMPLETE, AND MAKE OFERAIE ALL EXISTING LIGHTING, RECEPTACLES, AND CIRCUITRY.
24. PRIOR TO INSTALLING ANY UNDERGROUND CONDUIT, VERIFY CONDUIT SIZES AND POINTS OF SERVICE WITH THE SERVING UTILITIES.
25. ALL CONDUCTORS ARE TO BE STANDARD ANNEALED COPPER CONDUCTORS WITH TYPE THHN INSULATION, UNLESS NOTED OTHERWISE, AND SHALL
RUN FROM POINT TO POINT IN APPROVED CONDUIT. ALL CONDUITS, WHEN EXPOSED IN AREA WITH NO CEILING EXCEPT STOCKROOM AREAS),
SHALL BE INSTALLED IN RACKED FORM, WITH FITTED CONDUIT AND PARALLEL TO STRUCTURAL MEMBERS, (EXCEPT
PAGING SYSTEM -
HARDWARE
Ps
PS
PAGING SYSTEM -
WIRE
PS
EC
WIRED BY EC, FINAL
CONNECT. BY PS
PACING SYSTEM -
CONDUIT / PULL STRING
EC
EC
IF REQUIRED BY
AUTHORITY HAVING
BURGLAR / SECURITY SYSTEM -
HARDWARE
SSv
SC
26. ALL CONDUCTORS SHALL ME PHYSICALLY IDENTIFIED AT EACH END FOR CIRCUIT USAGE AND CONTINUITY.
27. GENERALLY, ALL CONDUITS SHALL BE CONCEALED EXCEPT FOR UNFINISHED AREAS, SUCH AS EQUIPMENT ROOMS. EXPOSED CONDUIT SHALL BE
ALLOWED ONLY AS NOTED ON PLAN AND AS APPROVED BY ESD&C'S PROJECT MANAGER. PAINTING OF CONDUITS, NOTED ON DRAWINGS OR
SPECIFICATIONS WILL BE BY GENERAL CONTRACTOR.
O Z 3
•• I_
V 0 t Ix
< Er a-
Q Y W
...I < W �
CL EL_ C7 t
c0 rn
W W o Ln
U) NO
Z 0
O
0
0
W
? M
V ♦ (n 0 LL_
Er •-^ U
Q
O U = W
Z . Z N •; i CL p
. .
Z O
H a :3 Z ~ EL
W N W = L; j Z U
X VJ ,_ U P EL 2 Q
W � 13- y N � W
BURGLAR / SECURITY SYSTEM -
WIRE
�
EC
LOW VOLTAGE WIRE IN CONDUIT
NTS
L
OODE023LONOTE
BURGLAR SECURITY SYSTEM
/ -
CONDUIT / PULL STRING
EC
EC
IF REQUIRED BY
AUTHORITY HAVING
JURISDIC.
SYMBOL
DESCRIPTION
MANUFACTURER it MODEL NUMBER
REMARKS
E L E C T R I C A L G E N E R A L N O T E S
NTS
RF TECH NOLOG SYSTEM -
HARDWARE
RF
RC
-e
SINGLE RECEFT. W/
COVERPLATE
20 AMP, 120 VOLT
OODE023COOE
RF TECHNOLOGY SYSTEM -
WIRE
RF
RC
1. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL ME "THRU- WIRING" WHERE AND WHENEVER
POSSIBLE.
2. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING
RELATED ELECTRICAL EQUIPMENT.
3. ALL RECEPTACLE CIRCUITS UP TO 100' -0" SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 100' -1" TO 150' -0"
IN LENGTH SHALL UTILIZE ¢10 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS 150' -1" UP TO 250' -0" IN LENGTH SHALL UTILIZE #8
CONDUCTORS MINIMUM. CIRCUITS ABOVE 250' -0" SHALL UTILIZE #G CONDUCTORS MINIMUM.
4. PLACEMENT OF ALL RECEPTACLES IN THE SALES AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO
CORNERS), UNLESS OTHERWISE NOTED. IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF
RECEPTACLE WITH ESD&C'S PROJECT MANAGER PRIOR TO ROUGH IN.
5. ALL RECEPTACLES AND COVERS (DUPLEX, QUADRAPLEX, ETC) SHALL BE THE COLORS AS NOTED IN THE ELECTRICAL POWER PUN NOTES AND
SCHEDULES.
i. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERATE SYSTEM.
7. ACCESS TO ALL COMPONENTS AND EQUIPMENT MUST BE PROVIDED TO MEET CODE AND SERVICE /MAINTENANCE EASE. WHERE DRYWALL CEILINGS
" "
ARE USED IN THE SAES AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN
INACCESSIBLE LOCATIONS, THE USE OF JUNCTION BOXES ABOVE DRYWALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES
USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. IF PLAN LOCATION IS NOT ACCEPTABLE,
IMMEDIATELY CONTACT ESD&C PROJECT MANAGER.
8. ANY PENETRATION THROUGH THE ROOF OR WALL WITH CONTROL WIRING MUST BE SLEEVED IN A CONDUIT.
DUPLEX RECEFT. W/
COVERPLATE
20 AMP, 120 VOLT
RF TECHNOLOGY SYSTEM -
CONDUIT / PULL STRING
EC
EC
IF REQUIRED BY
AUTHORITY HAVING
QUAD. RECEFT. W/
QUAD. ECE
20 AMP, 120 VOLT
CCTV / ALARM SYSTEM -
HARDWARE
•
CCTV WIRE J ALARM SYSTEM -
•
DUPLEX RECEFT. W/
COVERPLATE
DEDICATED DUPLEX RECEPTACLE ON ISOLATED GROUND, 20 AMP, 120 VOLT
CCTV I ALARM sYST MIN C -
CONDUIT / FULL ST ALARM
•
IF REQUIRED BY
AUTHORITY HAVING
JURISDIC.
bT
TELEPHONE OUTLET
WHITE COLOR RJ14C TELE. JACK IN SALES AND NON -SALES AREA.
Music SYSTEM -
HARDWARE (SPEAKERS / CD PLAYER)
M5
EC
OUTLET ELEPHONE
WHITE COLOR PLATE IN SAE S AND IN NON -SALES AREA.
MUSIC SYSTEM -
vnRE
EC
EC
MUSIC SYSTEM -
CONDUIT /PULL STRING
EC
EC
IF REQUIRED BY
AUTHORITY HAVING
JURISDIC.
O
JUNCTION BOX
JUNCTION BOX, 4" X 4" X 2 1/8" DEEP MINIMUM
DELIVERY BUZZER SYSTEM -
HARDWARE
LD
EC
MAGNETIC STARTER
FULL VOLTAGE STARTER IN A NEMA 1 ENCLOSURE, SIZE 1 MINIMUM
DELIVERY BuzZER SYSTEM -
WIRE
EC
EC
DISCONNECT SWITCH
HEAVY DUTY, FUSIBLE AND NON- FUSIBLE
DELIVERY BUZZER SYSTEM -
CONDUIT / FULL STRING
EC
EC
IF REQUIRED BY
AUTHORITY HAVING
JURISDIC,
9. ALL 24 VOLT COMMUNICATION AND /OR SENSOR WIRING ASSOCIATED WITH HVAC SYSTEM SHALL BE FURNISHED BY HVAC EQUIPMENT
MANUFACTURER AND INSTALLED BY ELECTRICAL CONTRACTOR. ALL FINAL CONNECTIONS SHALL BE BY MECHANICAL CONTRACTOR. ALL WIRING
AND EQUIPMENT SHALL Bf INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE N.E.C., LOCAL CODE, AND LANDLORD REQUIREMENTS.
ALL WIRING SHALL BE IN CONDUIT.
REVISIONS:
Al REOUIRED BY; DATE
- u /n /1T
®
DELIVERY BUZZER
TRANSFORMER
n
TRANSFORMER AT i -0 A.F.F.
MISCELLANEOUS ELECTRICAL ITEMS
Cy
DELIVERY BUZZER
SEE FLOOR PUN FOR MOUNTING HEIGHT
10. FURNISH AND INSTALL GROUND WIRE CONNECTION BY -PASS BETWEEN WATER METER PLUMBING END PIPE USING CLAMP CONNECTORS. MAKE
SURE PLUMBING METALLIC WATER PIPE IS SECURELY GROUNDED AS PER N.E.C. AND LOCAL CODES.
LIGHTING FIXTURES AND LAMPS
LD
EC
"
DELIVERY BUZZER
PUSHBUTTON
PUSH BUTTON UNIT AT 4i" A.F.F.
LIGTINUSSWSITCHES, RECEPTACLES AND
LD
EC
11. IFS ENCLOSURE FURNISHED BY ESD&C AND INSTALLED BY ELECTRICAL CONTRACTOR IS HEREIN DESCRIBED:
FLOOR BOXES AND COVERS
LD
EC
UNLESS 47NEWMSE
NOTED ON FLANS
4. EQUIPMENT NOTED HAS BEEN PREPURCHASED BY EXPRESS STORE DESIGN is CONSTRUCTION.
b. UNIT WILL BE SHIPPED TO THE PROJECT IN MULTIPLE SECTIONS AND THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR
OFF- LOADING OF EQUIPMENT, INSPECTION OF EQUIPMENT FOR DAMAGES, VERIFICATION OF EQUIPMENT RECEIVED, ENSURING THAT THE
EQUIPMENT RECEIVED IS COMPLETE AND MEETS THE SCHEDULED PANELS FOR THE PROJECT, MOVING AND MOUNTING OF SECTIONS AS WELL
O
CEILING SMOKE
DETECTOR
SYSTEM CONNECTED CEILING MOUNTED PHOTOELECTRIC TYPE SMOKE DETECTOR
JUNCTION BOXES
EC
EC
s
DUCT SMOKE DETECTOR
SYSTEM CONNECTED DUCT MOUNTED PHOTOELECTRIC TYPE SMOKE DETECTOR COMPLETE
WITH SAMPLING TUNES
AS REASSEMBLING OF SAME INTO ONE COMPLETE UNIT PER MANUFACTURER'S REQUIREMENTS.
c. ELECTRICAL CONTRACTOR IS TO CONNECT ALL PROVIDED INTERCONNECTING CABLES BETWEEN SECTIONS AND TORQUE CONNECTIONS PER
MANUFACTURER'S REQUIREMENTS.
HARDWARE SYSTEM -
HARDWARE
yy
EC
. noICAT s RMr�x » nis s
(�
SINGLE PHASE MOTOR
SE SORMATIC
POWER WIRINGSAND CONDUIT / PULL STRING
EC
EC
S H R E M S �""� r1 K
din
M. ELECTRICAL CONTRACTOR IS TO CONNECT LIGHTING BRANCH CIRCUITS TO APPROPRIATE LOAD TERMINALS PROVIDED WITHIN IFS ENCLOSURE
PER LIGHTING ZONES INDICATED IN THE PANEL SCHEDULE (I.E: ZONE A, 1, C). LINE SIDE WIRING AND LIGHTING CONTROL WIRING WILL BE
PREWIRED BY MANUFACTURER AT FACTORY. COORDINATE EXACT TERMINAL NUMBER FOR EACH CIRCUIT CONNECTION WITH MANUFACTURER'S
DRAWINGS.
s. ALL LIGHTING, RECEPTACLE, AND MISCELLANEOUS BRANCH CIRCUITS NOT SPECIFIED AS BEING CONTROLLED ARE TO BE WIRED DIRECTLY TO
THE CORRESPONDING BRANCH BREAKER IN THE DESIGNATED PANEL.
f. ALL CONNECTIONS WITHIN THE TELEPHONE /DATA SECTION AND HVAC CONTROL SECTION OF THE IFS ENCLOSURE ARE TO BE PERFORMED NY
OTHERS.
12. THE GENERAL CONTRACTOR'S FIRE SPRINKLER SUI- CONTRACTOR SHALL DESIGN AND INSTALL FIRE SPRINKLER SYSTEM CONFORMING TO
LANDLORD'S CRITERIA, TENANT'S REQUIREMENTS, AND PER LOCAL CODES AND NFPA STANDARDS.
13. CENTER ALL FIXTURES IN CEILING TIE WHERE APPLICABLE,
14. THE ELECTRICAL AND TELEPHONE SERVICES SHALL BE INSTALLED TO THE REQUIREMENTS OF THE SERVING UTILITIES. THE MAIN SERVICE SHALL
BE ABLE TO WITHSTAND THE AVAILABLE SHORT CIRCUIT CURRENT INDICATED (ABC) ON THE ONE -LINE DIAGRAM.
15. CONTRACTOR SHALL PROVIDE CUT SHEETS TO ESD&C FOR ALL EQUIPMENT AND DEVICES FURNISHED NY THE CONTRACTOR THAT DEVIATE FROM
SPECIFIED ITEM FOR REVIEW AND APPROVAL PRIOR TO THE PURCHASE OF ANY SUCH EQUIPMENT OR DEVICES.
1i. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND ARCHITECT FOR LOCATION, RESTRICTION, AND REQUIREMENTS OF
ALL CONCRETE SAW CUTS. SAW CUTS SHALL BE PATCHED TO MATCH EXISTING CONCRETE.
Shremshock Engineering, Inc.
6130 S. Sunbury Md. Westerville, OH 43081
t: 814 545 4550 f: 814545 4555
REECE A. P W�t�klll If #53410
='F *N,
CERTIFICA1TMR �N
J2708;� 7 �/
No. 53410
= Or '
TATS OF +k/
i I k/
•t► p. �`
DATA AND TELEPHONE SYSTEMS -
CABLE AND JACKS
TEL
TEL
TC
TRAFFIC COUNTER
DATA AND TELEPHONE SYSTEMS -
CONDUITS / PULL STRING
EC
EC
DUPLEX FLOOR RECEFT.
W COVERPLATE
/
20 AMP, 120 VOLT FLOOR BOX -ONE GANG 10X: 12414; LID: S3i25
TELEPHONE DEMARC PANEL -
PROTECTION OF DURING CONSTRUCTION /
RELOCATION DEMOLITION
GC
GC
CALL ESDtC TO
RELOCATE• DO NOT
CUT WIRES.
TWIST -LOCK
RECEPTACLE
DREAMSTEAMER - (FURNISHED BY ESD&C)
DUCT SMOKE DETECTOR
MC
MC
WIRED BY EC
MECHANICAL EQUIPMENT SHUT -DOWN RELAY
MC
MC
WIRED IT EC
DC
DOOR CONTACT
INSTALLED AT ALL EXIT DOORS, INCLUDING ROLLING GRILLES.
FIRE ALARM SYSTEM
•
DUCT MOUNTED
SMOKE DETECTORS
WIRED BY EC
M❑
MOTION DETECTOR
CEILING OR WALL MOUNTED
CASHWRAP -
BOWLER WIRING AND CONDUIT / FULL STRING
Ec
EC
IJ
REMOTE ANNUNCIATOR
TEST STATION
REMOTE ANNUNCIATOR TEST STATION FOR DUCT MOUNTED
SMOKE DETECTOR IN HVAC DUCT WORK
ROLLING GRILLE -
POWER WIRING AND CONDUIT / PULL STRING
•
DATE ISSUED: 02/18/11
DESIGNED NY: AOH
DRAWN AY: AOH
CHECKED NY: RAP
DREAMSTEAMER -
POWER WIRING AND CONDUIT / PULL STRING
EC
EC
RECEPTACLE BY LO
K
O
KEYPAD
KEYPAD MOUNTED AT 4'-4' A F.F. SEE FLOOR PLAN
N FOR LOCATION
AS -BUILT DRAWINGS
EC
EC
OS
SENSOR
SINGLE GANG BOX (2 "x4 ") FOR SENSOR AT 49" A.F.F. WITH FACE FLUSH TO
DRYWALL.
17. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL ENSURE THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS
AS REQUIRED.
ELECTRICAL
1
POWER PLAN �
NOTES
OT
THERMOSTAT
SINGE GANG BOX (2 "x4 ") FOR THERMOSTAT AT 48" A.F.F. WITH FACE FLUSH TO
DRYWALL
EC ELECTRICAL CONTRACTOR IER MS MUSIC NSYSTEMOVENDOROR TEL TELEPHONE AI
CONTRACTOR
EMS ENERGY MANAGEMENT SYSTEM VENDOR PC PLUMBING CONTRACTOR ANY ITEM NOT
FAC FIRE ALARM CONTRACTOR P5 FACING SYSTEM VENDOR
GC GENERAL CONTRACTOR RC RF TECHNOLOGY CONTRACTOR SHOWN IS THE
IF IFS SUPPLIER RF RF TECHNOLOGY SYSTEM VENDOR RESPONSIBILITY
LD LIGHTING PACKAGE DISTRIBUTOR
LL LANDLORD SC SECURITY CONTRACTOR
_ESNtC_EVffSS R "DIURUCTION SSV SECURITY SYSTEM VENDOR OF CONTRACTOR.
ELECTRONICALLY
OPERATED
DAMPER
REFER TO MECHANICAL DRAWINGS FOR SPECIFICATIONS.
DRAWING NUMBER:
IN %3
NOTE: ALL SYMBOLS MAY NOT BE USED ON THIS PROJECT. SHOWN FOR REFERENCE ONLY.
POWER REFERENCE
C SCHEDULE
"TS
ELECTRICAL
RESPONSIBILITY HE LE
SCHEDULE D U
NTS
c
E
POWER PLAN CONSTRUCTION NOTES