11-354-0422. COMPLY WITH MASTIC MANUFACTURER'S PRINTED DIRECTIONS FOR PREPARATION AND SEALING OF MOUNTING SURFACES BY SEALING DRYWALL, AND PLYWOOD, SUBSTRATES WITH DRYWALL AND PLYWOOD PAINT. ALLOW PAINT TO DRY BEFORE APPLYING MIRROR MASTIC. 3. MIRROR CHANNEL INSTALLATION: A. TO PLYWOOD: DRILL, DO NOT DIMPLE, BACK LIP OF CHANNEL TO RECEIVE FASTENERS WITH HOLES PROPERLY SIZED AND SPACED TO RECEIVE FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL TO PLYWOOD SUBSTRATE IN ACCORDANCE WITH THE FASTENER MANUFACTURERS WRITTEN INSTRUCTIONS. INSTALL THE WEB OF THE TOP CHANNEL 114" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR INTO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING INTO THE BOTTOM CHANNEL. AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS AT QUARTER POINTS FOR BOTTOM MIRROR CHANNELS USING ONLY 2 SETTING BLOCKS PER MIRROR PANEL. B, TO DRYWALL: MARK THE LOCATIONS FOR THE STUD FASTENERS ON THE BACK LIP OF EACH MIRROR CHANNEL AT EQUAL INTERVALS NOT OVER 8' ON CENTER, AND NOT MORE THAN 3' FROM ENDS PRIOR TO DRILLING THE CHANNEL. DRILL AND COUNtERSINK, DO NOT DIMPLE BACK LIP OF CHANNEL TO RECEIVE STUD FASTENERS AT MARKED LOCATIONS WITH HOLES PROPERLY SIZED TO RECEIVE STUD FASTENERS. ATTACH MIRROR CHANNELS BY SCREW ATTACHING MIRROR CHANNEL THROUGH THE BACK LIP OF THE CHANNEL THROUGH DRYWALL, STUD FRAMING, AND SHEET METAL BACKER PLATE SUBSTRATES IN ACCORDANCE WITH THE FASTENER MANUFACTURERS WRITTEN INSTRUCTIONS. I. INSTALL T14E WEB OF THE TOP CHANNEL 114" HIGHER THAN THE HEIGHT OF THE MIRROR TO ALLOW THE RAISING OF THE MIRROR INTO THE TOP CHANNEL AND ITS SUBSEQUENT LOWERING ONTO THE WEB OF THE BOTTOM CHANNEL, AFTER INSTALLING FASTENERS PLACE MASKING TAPE OVER THE ENTIRE LENGTH OF THE BACK LIP OF THE CHANNEL COMPLETELY COVERING THE FASTENER HEADS TO PROTECT THE MIRROR FROM BEING CHIPPED IN SETTING. ADHERE SETTING BLOCKS TO THE WEB OF THE BOTTOM MIRROR CHANNELS, LOCATED AT QUARTER POINTS, USING 2 SETTING BLOCKS PER MIRROR PANEL. 4. WOOD TRIM # INSTALLATION A, BEFORE INSTALLING MIRROR WOOD TRIM, EXAMINE SHOP- FABRICATED WORK FOR COMPLETION AND COMPLETE WORK AS REQUIRED, PRIME TO ALL EXPOSED SURFACES OF THE MIRROR WOOD TRIM WHICH WILL N LL BE I CONTACT WITH THE MIRROR BACKING TO ELIMINA TE INTERACTIONS BETWEEN THE RESINS IN THE WOOD AND THE MIRROR BACKING. B. INSTALL MIRROR WOOD TRIM PLUMB, LEVEL, TRUE, AND STRAIGHT WITH NO DISTORTIONS. SCRIBE AND CUT MIRROR WOOD TRIM TO FIT ADJOINING WORK, AND REFIN15W CUT SURFACES AND REPAIR DAMAGED FINISH AT CUTS. INSTALL WITH MINIMUM NUMBER OF JOINTS POSSIBLE, USING FULL - LENGTH PIECES (FROM MAXIMUM LENGTH OF WOOD TRIM AVAILABLE) TO GREATEST EXTENT POSSIBLE. DO NOT USE PIECES LESS THAN 16" LONG, EXCEPT WHERE 514ORTER SINGLE- LENGTH PIIECES ARE NECESSARY. SCARF RUNNING JOINTS. MITERS OVER 4' LONG 514ALL BE SPLINED AND GLUED. L. PROTECTION AND CLEANING 1. PROTECT MIRRORS FROM BREAKAGE AND CONTAMINATING SUBSTANCES RESULTING FROM CONSTRUCTION OPERATIONS. USING CLEAN WARM WATER, CLEAN MIRRORS BY METHODS RECOMMENDED IN REFERENCED GLAZING STANDARDS. DIVISION 09: FINISHES SECTION 062116 - GYPSUM BOARD ASSEMBLIES A. GENERAL: PROVIDE GYPSUM BOARD SYSTEMS INCLUDING METAL FRAMING ACCESSORIES, GYPSUM BOARD, JOINT TREATMENT, ACOUSTICAL INSULATION, ACOUSTICAL SEALANT, AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. B. STANDARDS: COMPLY WITH A5TM C754 AND A5TM C440, AND REQUIREMENTS FOR FIRE RATINGS. 1. DEFLECTIONS: MAXIMUM L1240 TYPICAL, L/360 AT LOCATIONS INDICATED TO RECEIVE TILE. C. FIRE -RATED ASSEMBLIES: LISTED BY UNDERWRITER'S LABORATORY, GYPSUM ASSOCIATION (GA) FILE NO'S IN GA -600 FIRE RESISTANCE DESIGN MANUAL, OR OTHER LISTING A IC AUTHORITIES. APPROVED BY PPL AB LE D. SYSTEMS RESPONSIBILITY: PROVIDE PRODUCTS MANUFACTURED BY OR RECOMMENDED BY MANUFACTURER OF GYPSUM BOARD TO MAINTAIN SINGLE - SOURCE RESPONSIBILITY FOR SYSTEM. E. MANUFACTURERS: U5G, GEORGIA PACIFIC, OR NATIONAL GYPSUM. F. METAL FRAMING: CONFORM TO ASTM 0754; COMPLETE I6 GAGE AND LIGHTER STEEL FRAMING AND SUSPENSION SYSTEM FOR GYPSUM BOARD SYSTEMS; PROVIDE ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION. I. INSTALL OWNER FURNISHED GARCY STUDS AND STANDARDS; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. 2. MANUFACTURED SUSPENSION SYSTEM SUCH AS CHICAGO METALLIC /DRYWALL 5Y5TEM 15 ACCEPTABLE. G. GYPSUM BOARD: CONFORM TO Ci40; UL LISTED FIRE RESISTANT GYPSUM BOARD THROUGHOUT. I. STANDARD: ASTM C36, 5/8" THICK. 2. CORE BOARD: ASTM 0442, I" THICK. H. GYPSUM BOARD ACCESSORIES: COMPLY WITH ASTM CM. I. PROVIDE PROTECTIVE COATED STEEL CORNER BEADS AND EDGE TRIM; TYPE DESIGNED TO BE CONCEALED IN FINISHED CONSTRUCTION BY TAPE AND JOINT COMPOUND. 2. CORNER BEADS: MANUFACTURER'S STANDARD METAL BEADS. 3. REINFORCING TAPE, JOINT COMPOUND, ADHESIVE, WATER, FASTENERS: TYPES RECOMMENDED DED BY SYSTEM MANUFACTURER AND CONFORMING WITH A5 TM C475. . 4. CONTROL/EXPANSION JOINTS: 2 -PIECE DRYWALL JOINTS DESIGN To EE FINISHED TO ADJACENT SURFACE WITH TAPE 4 SPACKLE. 5. MAXIMUM CALCULATED DEFLECTION OF ANY FRAMING MEMBER IN DIRECTION NORMAL TO THE PLANE OF THE WALL WHEN SUBJECTED TO SPECIFIED PRESSURES SHALL BE LIMITED TO L/175 OF THE SPAN BUT NO MORE THAN 314'. I. FIRE RATED CONSTRUCTION: COMPLY WITH UNDERWRITER'S LABORATORIES CERTIFIED FIRE TESTS ANp APPLICABLE CODE REQUIREMENTS. I. SHAFT WALL SYSTEM: PROVIDE AT SHAFTS AND WHERE INDICATED. J. ACOUSTICAL ACCESSORIES. PROVIDE ASTM C665, TYPE I ACOUSTICAL INSULATION AND ASTM 04119 PAINTABLE ACOUSTICAL 5EALANT5 WHERE ACOUSTICAL SYSTEMS ARE INDICATED. K. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, REFERENCED AND APPLICABLE REQUIREMENTS FOR FIRE RATINGS AND ACOUSTICAL RATINGS. I. SPECIAL METAL STUD AND GYPSUM DOOR: PROVIDE SPECIAL CONFIGURATION AS INDICATED ON DRAWINGS. L. METAL FRAMING ERECTION: ERECT METAL FRAMING IN ACCORDANCE WITH ASTM C764 AND MANUFACTURER'5 RECOMMENDATIONS. I. DOOR OPENING FRAMING: INSTALL DOUBLE STUDS AT DOOR FRAME JAMBS; INSTALL RUNNERS ON EACH SIDE OF OPENING AT FRAME HEAD HEIGHT BETWEEN JAMB STUDS AND ADJACENT STUDS, 2. INSTALL MEMBERS TRUE TO LINES AND LEVELS TO PROVIDE SURFACE FLATNESS WITH MAXIMUM VARIATION OF 1 /6" IN 10-0" IN ANY DIRECTION. 3. INSTALL METAL FRAMING BACKING WHERE REQUIRED FOR SUPPORT OF FIXTURES, CABINETS, ACCESSORIES AND HARDWARE. 4. COORDINATE INSTALLATION OF BUCKS, ANCHORS, BLOCKING, ELECTRICAL AND MECHANICAL WORK HAIGH 15 TO BE PLACED IN OR BEHIND PARTITION FRAMING; i ALLOW ITEMS TO BE INSTALLED AFTER FRAMING 15 COMPLETE. M. CEILING FRAMING INSTALLATION: ERECT IN ACCORDANCE WITH A5TM 0754 AND MANUFACTURER'S RECOMMENDATIONS. REINFORCE OPENINGS IN CEILING SUSPENSION SYSTEM. 1• LATERALLY BRACE ENTIRE SUSPENSION SYSTEM, N. GYPSUM BOARD INSTALLATION: INSTALL IN ACCORDANCE WITH ASTM 0840 AND MANUFACTURER'S RECOMMENDATIONS. USE SCREWS WHEN FASTENING GYPSUM BOARD TO FURRING AND TO FRAMING. I, FOR FIRE RATED SYSTEMS COMPLY WITH REQUIREMENTS FOR FIRE RATINGS. 2. PLACE CORNER BEADS AT EXTERNAL CORNERS; USE LONGEST PRACTICAL LENGTHS. 3. PLACE EDGE TRIM WHERE GYPSUM BOARD ABUTS DISSIMILAR MATERIALS. 4. TAPE, FILL, AND SAND EXPOSED JOINTS, EDGES, CORNERS AND OPENINGS TO PRODUCE SURFACE READY TO RECEIVE FINISHES; FEATHER COATS ONTO ADJOINING SURFACES.. 5. FINISHING: COMPLY WITH GYPSUM ASSOCIATION (GA) 'LEVELS OF GYPSUM BOARD FINISH" GA LEVEL 4, THREE COAT FINISHING AND SANDING IS REQUIRED FOR SURFACES INDICATED TO BE PAINTED; PROVIDE FLU5H, SMOOTW JOINTS AND SURFACES READY FOR APPLIED PAINT FINISHES. 6. REMOVE AND REPLACE DEFECTIVE WORK. 0. ACOUSTICAL ACCESSORIES INSTALLATION. I. PLACE ACOUSTICAL INSULATION TIGHT WITHIN SPACES, AROUND CUT OPENINGS, REWIND AND AROUND ELECTRICAL AND MECHANICAL ITEMS WITHIN PARTITIONS, AND TIGHT TO ITEMS PASSING THROUGH PARTITIONS. 2. PLACE ACOUSTICAL SEALANT WITHIN PARTITIONS IN ACCORDANCE WITH MANUFACTURER'5 RECOMMENDATIONS; INSTALL ACOUSTICAL SEALANT AT GYPSUM BOARD PERIMETER, AT BASE LAYER AND FACE LAYER OF GYPSUM BOARD, AND PENETRATIONS OF PARTITIONS: B. TOLERANCE: MAXIMUM 114' SPACE BETWEEN GYPSUM BOARD AT FLOOR, CEILING, AND PENETRATIONS. 4. INSTALL ELECTRICAL BOX PADS WITH PADS MOLDED AND PRESSED ON BACK 51DE OF BOX, CLOSING OPENINGS, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, FOR COMPLETE ACOUSTICAL BARRIER. SECTION 093000 - TILING A. GENERAL: PROVIDE TILE SYSTEMS INCLUDING SETTING MATERIALS, GROUT, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. STANDARDS: COMPLY WITH TILE COUNCIL OF AMERICA "HANDBOOK OF CERAMIC TILE INSTALLATION" INCLUDING REFERENCED A5TM AND ANSI STANDARDS. C. TILE MANUFACTURERS: AS INDICATED ON DRAWINGS. 1, FLOOR TILE: PROVIDE NON -SLIP UNITS WITH MINIMUM WET AND DRY VALUE OF 040 COEFFICIENT OF FRICTION W14EN TESTED IN ACCORDANCE WITH ASTM C1028• D. LATEX THIN SET: T14INSET BOND COAT, LATEX- CEMENTITIOUS MORTAR CONFORMING TO ANSI A118.4. E. GROUT. ANSI A1164, LATEX CEMENTITIOUS TYPE BY LATICRETE, BOSTIK OR CUSTOM BUILDING PRODUCTS. GROUT JOINT 1/6' MAX. OR AS INDICATED IN FINISH SCHEDULE. F. INTEGRAL WATERPROOFING: LATICRETE, BOSTIK, OR NOBEL LIQUID RUBBER INTEGRAL TILE SETTING WATERPROOFING SYSTEM WITH NO BITUMINOUS EXTENDERS; PROVIDE AT TILE APPLICATIONS ABOVE GRADE. G. CLEANING AND SEALING MATERIALS: AS RECOMMENDED BY TILE AND GROUT MANUFACTURERS, SUCH AS BOSTIK CONSTRUCTION PRODUCTS /HYDROMENT CERAMASEAL. H. PREPARATION: DO NOT COMMENCE WORK UNTIL SURFACE CONDITIONS ARE WITHIN TOLERANCES REQUIRED FOR PROPER INSTALLATION; APPLY LATEX LEVELING MATERIAL WHERE NECESSARY TO MEET REQUIRED TOLERANCES. I, INSTALLATION: COMPLY WITH TILE COUNCIL OF AMERICA (TCA) HANDBOOK FOR CERAMIC TILE INSTALLATION FOR LATEX BOND COAT THIN SET APPLICATION. I. TILE: INSTALL TILE IN ACCORDANCE WITH REFERENCED ANSI STANDARDS AND TCA RECOMMENDATIONS FOR TYPE OF 5U55TRATE AND INDICATED SETTING METHOD; LATEX- CEMENT THIN SET AND BOND COATS REQUIRED. 2. PLACE TILE IN ACCORDANCE WITH PATTERNS INDICATED ON DRAWINGS OR AS DIRECTED BY OWNER'S PROJECT MANAGER; CAREFULLY PLAN TILE LAYOUTS, ENSURE PATTERN 15 UNINTERRUPTED FROM ONE SURFACE TO THE NEXT AND THROUGH DOORWAYS. 3. SEAL TILE AND GROUT SURFACES WHERE RECOMMENDED BY MANUFAGTURER FOR MATERIALS AND APPLICATIONS INVOLVED; COMPLY WITH MANUFACTURER'S RECOMMENDATIONS. SECTION 095100 - ACOUSTICAL CEILINGS A. GENERAL: PROVIDE ACOUSTICAL CEILINGS INCLUDING SUSPENSION SYSTEM, TRIM, AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. STANDARDS: CONFORM TO ASTM 0635 FOR METAL SUSPENSION SYSTEM AND ASTM C636 OR INSTALLATION OF ACOUSTICAL CEILINGS. C. RFORMANCE REQUIREMENTS: PROVIDE PRODUCTS LISTED BY UNDERWRITERS LA RATORIES (UL). FLAME SPREAD /SMOKE DENSITY: PROVIDE PRODUCTS MEETING CODE REQUIR ENTS FOR MAXIMUM 25 FLAME SPREAD AND MAXIMUM 25 SMOKE DENSITY. D. SEISMIC EQUIREMENTS: COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS F R SEISMIC BRACING F CEILING SUSPENSION SYSTEM, AND WITH ASTM E580. E. SUBMITTAL SUBMIT PRODUCT DATA, SHOP DRAWINGS INDICATING LAYOUT, NO SAMPLES OF GRID, TR , AND CEILING UNITS.5AND F. INSTALLER: FI WITH MINIMUM THREE YEAR'S SUCCESSFUL EXPERIENCE I PROJECTS OF SIMILAR TYPE D SCOPE; ACCEPTABLE TO MANUFACTURE F ACOUSTI L UNITS, G. PROJECT CONDITI S. DO NOT INSTALL CEILINGS UNTIL NG IS E LOSER, SUFFICIENT HEAT PROVIDED, DUST GENERATING A I ES 14AV ERMINATED AND OVERHEAD WIECHANI L WORK IS COMPLETED, TEST APPR D; ALLOW WET WORK TO DRY PRIOR TO INSTALLATION. H. ACOUSTICAL UNITS: TYP AS INDICATED ON D fNGS". MANUF TURERS: ARMSTRONG OR APPROVE EQUAL. 1. NON- RATED(NON -5A 5) AREAS: ARM5 24" X 4 X 5/8" FINE F155URED PANELS (tk 2+1) WITH 5QUA E - WWI , I UNSGORED ON- NAL. /N D REC 2• NON -RATED (SALES) A 5: ARMS70 24" X 2 X 5/8" DUNE (#1775) BEVELED TEGULAR -WHI 3. RATED AREAS: ARMSTRON 24" X 24" X 5/8' DUNE ( #I& ) LED TEG R -WHITE A. RATED (NON - SALES) AREAS: ONG 2 X 48' X 5/8" FINE FISSURED PANELS (#1830) WITH SQUAR - WHI , UN5CORED /NON - DIRECTIONAL. I. SUSPENSION SYSTEM: TYPE AS I I ON D WINGS. MANUFACTURERS: ARMSTRONG OR D UAL. I. FOR ARMSTRONG 6(17201 CEILIN AR T ONG PRELUDE XL 15/16' EXPOSED TEE OR STANDARD 1" PRO LE WHITE BA ENAMEL FINISHED STEEL OR ALUMINUM TYPE, EDGE TRIM IN TICAL G NCEALED. 2• FOR ARMSTRONG # ILING: MSTRO G SUPRAFINE XL 01/16" EXPOSED TEE. OR 111/16" NARROW E WHIT BAKED E MEL FINISH. STEEL OR ALUMINUM TYPE, EDGE TRIM WIT CAL LE CONCEALED. 3• FOR ARM5TR0 2 CEILI : ARMSTRONG 5 RAFINE XL FIRE GUARD 01/16" EXPOSED TEE. J. PREPARATION: M FILING EA AND ESTABLISH L YOUT OF ACOUSTICAL UNITS TO BALANCE BORDER WIDTHS OPPOSITE EDGES OF E H CEILING; DO NOT USE LE55 THAN HALF WIDTH UNIT AT BORDERS. COORDINATE ITH OTHER WORK SUPPORTED BY EN!A ' G THROUGH CEILINGS, INCL ING LIGHT FIXTURES, WVAC EQUIPMEI "V PART ION SYSTEMS. K. INSTALLATI PLY WI MANUFACTURER RECOMMENDATIONS, ASTM C436, AND APPLICABLE I 1111 ENJ 5 FOR FIRE RATINGS. 1. FINISHED CEILIN : TRUE TO LINES AND LEVELS AND FREE OM WARPED, SOILED OR DAMAGED RID OR ACOUSTICAL UNITS, 2. INSTALL CEILI SYSTEMS IN A MANNER CAPABLE OF SUPPOR G SUPERIMPOSED LOADS, WIT MAXIMUM PERMISSIBLE DEFLECTION OF 1 /9" IN 10' ". 3. ENSURE 5 PENSION SYSTEM IS LOCATED TO ACCOMMODATE FITT GS AND UNITS OF EQUIPME WHICH 15 TO BE PLACED AFTER INSTALLATION OF CEILI GRID. 4. WHER DUCTS OR OTHER EQUIPMENT PREVENT REGULAR SPACING OF NGERS, REIN RCE NEAREST ADJACENT 14ANGERS AND RELATED CARRYING CH NEL5 AS RE IRED TO SPAN REQUIRED DISTANCE. . 5. IN ALL EDGE MOLDINGS AT INTERSECTION OF CEILING AND VERTICAL SU ACES, U ING MAXIMUM LENGTHS, STRAIGHT, TRUE TO LINE AND LEVEL; MITER C NERS• 6. FIT ACOUSTIC UNITS IN PLACE, FREE FROM DAMAGED EDGES OR DEFECTS DE [MENTAL TO APPEARANCE AND FUNCTION. LAY DIRECTIONALLY PATTERNED UNITS ONE Y WITH PATTERN AS DIRECTED. FIT BORDER UNITS NEATLY AGAINST ABUTTING SURFA S. I. INSTALL UNITS LEVEL, IN UNIFORM PLANE AND FREE FROM TWIST, WARP AND DEN . S. INSTALL HOLD -DOWN CLIPS WHERE REQUIRED BY APPLICABLE CODES AND WHERE CEILING IS WITHIN 20-0" OF AN EXTERIOR DOOR. L. ADJUSTMENT. ADJUST SAGS OR TWISTS WHICH DEVELOP IN CEILING SYSTEM AND REPLACE ANY PART WHICH IS DAMAGED OR FAULTY. SECTION 096429 - WOOD STRIP AND PLANK FLOORING A GENERAL: INSTALL SHOP FINISHED ACRYLIC IMPREGNATED WOOD STRIP FLOORING SYSTEM WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION, B. PROJECT CONDITIONS: DO NOT INSTALL WOOD FLOORING SYSTEM UNTIL WET CONSTRUCTION WORK IS COMPLETED AND SURROUNDING AIR WAS MAXIMUM MOISTURE CONTENT OF 40 PERCENT. PROVIDE PERMANENT HEAT, LIGHT AND VENTILATION PRIOR TO INSTALLATION. I. MAINTAIN ROOM TEMPERATURE BETWEEN 60 -010 DEGREES F, WUMIDITY 25 -50 FOR PERIOD OF SEVEN DAYS PRIOR TO DELIVERY OF MATERIALS C. MANUFACTURER: ARCHITECTURAL SYSTEMS, INC. D. WOOD: AS INDICATED ON DRAWINGS, TONGUE AND GROOVED EDGES WITH SHOP APPLIED ACRYLIC IMPREGNATED FINISH INTENDED FOR DIRECT ADHESIVE APPLICATION TO CONCRETE. E. ADHESIVE: TYPE AS RECOMMENDED BY MANUFACTURER TO ENSURE MAXIMUM DURABILITY OVER TIME; NONTOXIC, WATERPROOF TYPE SUITABLE FOR FLOORING, SUBSTRATE, AND ACCEPTABLE TO APPLICABLE AUTHORITIES. F. 5U5FLOOR FILLER: PREMIX LATEX REQUIRING WATER ONLY TO PRODUCE CEMENTITIOUS PASTE, G. DIVIDER STRIPS: TYPE AS INDICATED IN DETAILS. H. PREPARATION: BROOM CLEAN SUBSTRATE SURFACE AND ENSURE FLOOR SURFACE 15 SMOOTH AND FIAT TO PLUS OR MINUS I/8" PER 10' -0 ", FREE OF OIL, GREASE, DUST AND FOREIGN SUBSTANCE. USE LATE( FILLER TO PATCH CRACKS AND SMALL HOLES, AND FOR MINOR LEVELING, I. GRIND CONCRETE WHERE RIDGES AND IRREGULARITIES PROVIDE UNSATISFACTORY SUBSTRATE FOR WOOD STRIP FLOORING. 1. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTION FOR DIRECT APPLICATION OF WOOD STRIP FLOORING OVER CONCRETE. 1• ENSURE JOINTS OF WOOD FLOORING ARE IN LINE; ENSURE FULL ADHESIVE CONTACT FOR PERMANENT BOND TO SUBSTRATE. 2. LAY FLOORING SYMMETRICAL. ABOUT ROOM CENTER LINE; FIT NEATLY TO VERTICAL INTERRUPTIONS. 3. PROVIDE DIVIDER STRIPS AT CENTERLINE OF DOOR OPENINGS AND WHERE FLOORING TERMINATES WITH TILE OR OTHER FLOOR FINISHES. (SEE FINISH PLAN LAYOUT) 4. PROVIDE MAXIMUM 1:12 SLOPE WHERE FINISHED FLOOR SURFACE CHANGES LEVEL BETWEEN WOOD FLOORING AND ADJACENT FLOORING, 5. PROVIDE SHEET VINYL UNDERLAYMENT MOISTURE BARRIER OVER CONCRETE OR AS RECOMMENDED BY VENDOR. SECTION 096519 - RESILIENT TILE FLOORING A. GENERAL: PROVIDE RESILIENT TILE FLOORING SYSTEM AND RESILIENT BASE, WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. 5. SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EACH TYPE OF FLOORING AND EASE COLOR AND PATTERN SELECTED. C. PROJECT CONDITIONS: ENSURE FLOOR SURFACES ARE SMOOTH AND FLAT WITH MAXIMUM VARIATION OF 1/8" IN 10-0% ENSURE CONCRETE FLOORS ARE DRY AND EXHIBIT NEGATIVE ALKALINITY, CARBONIZING AND DUSTING. D. RESILIENT TILE: 12' X 12" BY 1/8' THICK; VINYL COMPOSITION TILE CONFORMING TO ASTM 1`1066, COMPOSITION I; COLOR AND PATTERN AS INDICATED IN FINISH SCHEDULE. 1. MANUFACTURERS: ARMSTRONG WORLD INDUSTRIES, INC. OR APPROVED EQUAL FLAMMABILITY! PROVIDE MATERIALS TESTED UNDER ASTM E648, FLOORING RADIANT PANEL TEST, WITH RESULTS OF 0.45 WATTS /CM2 OR HIGHER. 2. SLIP RESISTANCE: PROVIDE MATERIALS TESTED UNDER ASTM D2047, JAMES SLIP TEST WITH MINIMUM 0.6 RATING FOR FLOORS. E. RESILIENT BASE: F5 55 -W -40, 1/8" GAGE COVED BASE AT HARD FLOOR SURFACES, STRAIGHT (TOP SET) BASE At CARPET; PROVIDE PREMOLDED END STOPS AND EXTERNAL CORNERS. 1. MANUFACTURER: ARMSTRONG; MOLDED VINYL BASE. HEIGHT: 4" OR 6' AS INDICATED IN FINISH SCHEDULE. 2. COLOR: AS INDICATED IN FINISH SCHEDULE, F. EDGE STRIPS AND ACCESSORIES: RUBBER OR VINYL EDGE STRIPS MATCHING RESILIENT FLOORING; LATEX- MODIFIED PORTLAND CEMENT BASED UNDERLAYMENT AND PATCHING COMPOUND; NONTOXIC WATER RESISTANT TYPE ADHESIVES. G. SUBFLOOR FILLER: WHITE PREMIXED LATEX - CEMENT PASTE DESIGNED FOR PROVIDING THIN 50LID SURFACE FOR LEVELING AND MINOR RAMPING OF SUBSURFACE TO ADJACENT FLOOR FINISHES; MATERIAL CAPABLE OF BEING APPLIED AND FEATHERED OUT TO ADJACENT FLOOR WITHOUT 5PALLING. H. PRIMERS AND ADHESIVES: WATERPROOF NONTOXIC TYPES AS RECOMMENDED BY FLOORING MANUFACTURER FOR SPECIFIED MATERIAL AND APPLICATION. SEALER AND WAX: TYPE RECOMMENDED BY FLOORING MANUFACTURER FOR MATERIAL TYPE AND LOCATION, J. PREPARATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS FOR PREPARATION AND WITH ASTM 1`710; REMOVE SUBFLOOR RIDGES AND BUMPS; FILL LOW SPOTS, CRACKS, JOINTS, HOLES AND DEFECTS WITH 5UBFLOOR FILLER. K. FLOORING INSTALLATION: CONFORM WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; SET FLOORING IN PLACE, PRESS WITH HEAVY ROLLER TO ENSURE FULL ADHESION; SCRIBE FLOORING TO WALLS, COLUMNS, AND OTHER APPURTENANCES, TO PRODUCE TIGHT JOINTS. 1• INSTALL MINIMUM 1/2 TILE AT ROOM AND AREA PERIMETER; TERMINATE RESILIENT FLOORING AT CENTERLINE OF DOOR OPENINGS WHERE ADJACENT FLOOR FINISH 15 DISSIMILAR; INSTALL EDGE STRIPS AT UNPROTECTED AND EXPOSED EDGES WHERE FLOORING TERMINATES. 2. SEE FINISH PLAN FOR FLOOR PATTERN DESIRED IN EACH AREA. L. BASE INSTALLATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS; APPLY TO WALLS, COLUMNS, PILASTERS, CASEWORK, AND OTHER PERMANENT FIXTURES IN ROOMS AND AREAS WHERE BASE IS REQUIRED. 1. MITER INTERNAL CORNERS; USE PREMOLDED SECTIONS FOR EXTERNAL CORNERS AND EXPOSED ENDS; SCRIBE AND FIT TO DOOR FRAMES AND OTHER OBSTRUCTIONS. M . EDGE STRIPS: INSTALL WH ERE EDG E OF TILE WOULD OTWERWISE BE EXPOSED, BUTT TO FLOORING WITHOUT GAPS; SET IN ADHESIVE. N. CLEANING: CLEAN, SEAL AND WAX FLOOR IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. SECTION 096200 - CARPETING (WALK -OFF MATI A. GENERAL: PROVIDE ENTRY CARPET TYPE FLOOR WALK OFF MATS AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PER50NS WITH DISABILITIES. C. MANUFACTURER! CONSTRUCTION SPECIALTIES, INC. REFER TO FINISH SCHEDULE. D. INSTALLATION! COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND STANDARDS. SECTION 097216 - VINYL COATED FABRIC WALLCOVERING A. GENERAL: INSTALL VINYL WALL COVERING AND PROVIDE ACCESSORIES AS RE QUIRED FOR COMPLETE FINISHED INSTALLATION, B. MAINTENANCE INSTRUCTIONS: FURNISH MANUFACTURER'S RECOMMENDED CLEANING MATERIALS IN USE C ANIN MATERIALS WHICH AND APPLICATION METHODS, INCLUDING PRECAUTIONS E OF LE G TE MAY BE DETRIMENTAL TO SURFACES. C • MANUFACTURER: WOLF - CORDON D. TYPE: VINYL WALL COVERING CONFORMING TO F5 DD -G -408, TYPE II VINYL WALL COVERING WITH CLOTH BACKING, MINIMUM 24 TO 26 OZ.; WITH MAXIMUM 25 FLAME SPREAD AND SMOKE DEVELOPED, ASTM EM (UL CLASS A, UBC CLASS 1). E. ADHESIVE: NONTOXIC TYPE RECOMMENDED BY WALL COVERING MANUFACTURER TO SUIT APPLICATION, F. PRIMER- PROVIDE NON- STAINING, NON -TOXIC RELEASE COAT PRIMER AS RECOMMENDED BY WALL COVERING MANUFACTURER, 1. PROVIDE PRIMER WHICH ALLOWS REMOVAL OF WALL COVERING FROM GYPSUM BOARD WITHOUT DAMAGING PAPER FACING OF BOARD, AND WITHOUT PREMATURE SEPARATION OF WALL COVERING FROM WALL. G. EXAMINATION: ENSURE SURFACES TO RECEIVE WALL COVERING ARE CLEAN, TRUE AND FREE OF IRREGULARITIES, DO NOT COMMENCE WITH WORK UNTIL SURFACES ARE SATISFACTORY. 1. ENSURE WALL SURFACE FLATNESS TOLERANCE DOES NOT VARY MORE THAN 1/8' IN 10' -0111 NOR VARY AT A RATE GREATER THAN 1 /I6" PER RUNNING FOOT. N. PREPARATION: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS; FILL NICKS, GOUGES AND OTHER MINOR IMPERFECTIONS OF SUBSTRATES WITH LATEX FILLER; SAND SMOOTH, FLUSH WITH SURFACE; APPLY PRIME COAT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, I. APPLICATION: HANDLE AND APPLY WALL COVERING IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUGTIONS; MIX AND APPLY ADHESIVE IN ACCORDANCE WITH ADHESIVE MANUFACTURER'5 RECOMMENDATIONS. 1. USE FABRIC PANELS IN EXACT ORDER AS CUT FROM ROLLS; USE ROLLS IN CONSECUTIVE ORDER AS NUMBERED BY MANUFACTURER. 2• HORIZONTAL SEAMS AND CUTTING AT CORNERS ARE NOT ACCEPTABLE; CUT NO CLOSER THAN 2' OF AN INSIDE CORNER, AND NOT CLOSER THAN 6" OF AN OUTSIDE CORNER. 3. FILL SPACES ABOVE AND BELOW WINDOWS, DOORS, AND SIMILAR AREAS IN SEQUENCE FROM ROLL. SECTION 097216.16 - RIGID SHEET VINYL WALLCOVERING (F.R.P. PANELS) A. GENERAL: PROVIDE PREFINISHED GLASS FIBER REINFORCED POLYESTER RESIN FABRICATED WALL PANELS, WITH TRIM PIECES AND ACCESSORIES AS REQUIRED FOR COMPLETE INSTALLATION. MANUFACTURERS: MARLITE 15. PANELS: FIBERGLASS REINFORCED PLASTIC (FRP) PANEL SYSTEM; NOMINAL 0.CAO" C. THICKNESS; WHITE. 1• FIRE - RATING: CLASS I (UL CLA55 A), MAXIMUM 25 FLAME SPREAD, 25 SMOKE GENERATION BASED ON ASTM E64. INSTALLATION. TRIM PIECES: MANUFACTURER'S STANDARD MATCHING MOLDINGS AND TRIM PIECES AS D. REQUIRED FOR COMPLETE, FINISHED INSTALLATION, AND AS REQUIRED FOR JOINTS, CORNERS AND PANEL EDGES. ADHESIVE: MANUFACTURER'S RECOMMENDED NONTOXIC, WATERPROOF ADHESIVE SUITABLE E. FOR SUBSTRATES INDICATED. PRIMER: PROVIDE NON - STAINING RELEASE COAT PRIMER AS RECOMMENDED BY WALL PANEL F. MANUFACTURER WHERE PANELS ARE APPLIED TO GYPSUM BOARD. MECHANICAL FASTENERS: CONCEALED TYPE ONLY; TYPES AS RECOMMENDED BY SYSTEM G. MANUFACTURER. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE A. REQUIREMENTS FOR FIRE RATINGS. COPE AND MITER TRIM PIECES. INSTALL PANELS IN MAXIMUM SIZE INCREMENTS AVAILABLE. I. INSTALL WALL PANELING BEFORE INSTALLATION OF PLUMBING, BASES, HARDWARE, AND SIMILAR ACCESSORIES. 2. SECURELY ADHERE PANELS TO WALL SURFACES; USE BLIND NAILING METHODS AS REQUIRED TO SUPPORT PANELS UNTIL ADHESIVE DRIES; EXPOSED MECHANICAL FASTENERS SHALL NOT BE ACCEPTABLE. REMOVE EXCF-55 ADHESIVE FROM EDGES; WIPE SEAM CLEAN WITH DRY CLOTH TOWEL. SECTION 099000 - PAINTING AND COATING GENERAL: PROVIDE PAINTING OF EXPOSED ITEMS AND SURFACES NOT PREFINISHED, AS A. REQUIRED FOR COMPLETE FINISHED INSTALLATION, 5URFACE5 NOT TO BE PAINTED: PREFINISHED ITEMS; CONCEALED AND INACCESSIBLE AREAS, B. CODE- REQUIRED LABELS, STANDARDS: PROVIDE MATERIALS APPROVED FOR USE BY APPLICABLE AIR QUALITY C. MANAGEMENT DISTRICT FOR LIMITATIONS OF VOLATILE ORGANIC COMPOUNDS FOR ARCHITECTURAL COATINGS. SUBMITTALS! FURNISH PRODUCT DATA AND SAMPLES. D. I. DUPLICATE PAINTED FINISHES OF APPROVED SAMPLES ON ACTUAL WALL SURFACES AND COMPONENTS FOR APPROVAL PRIOR TO COMMENCING WORK. DELIVERYi DELIVER MATERIALS TO JOB SITE IN ORIGINAL, NEW AND UNOPENED PACKAGES E. AND CONTAINERS BEARING MANUFACTURER'S NAME AND LABEL, MANUFACTURERS: BENJAMIN MOORE, PPG, RALPH LAUREN, MDC WALLCOVERINGS F, MATERIAL QUALITY: PROVIDE TOP LINE QUALITY COMMERCIAL GRADE (PROFESSIONAL G PAINTER) PAINTS; MATERIALS NOT BEARING MANUFACTURER'S IDENTIFICATION AS A BEST -GRADE PRODUCT SHALL NOT BE ACCEPTABLE. 1. PRIMERS: PROVIDE PREMIUM GRADE PRIMERS RECOMMENDED BY PAINT MANUFACTURER FOR SUBSTRATES INDICATED AND FOR FINISH SYSTEMS SPECIFIED. 2. UNDERCOATS AND BARRIER COATS: PROVIDE UNDERCOAT PAINTS PRODUCED BY SAME MANUFACTURER AS FINISH COATS; USE ONLY THINNERS APPROVED BY PAINT MANUFACTURER, AND USE ONLY WITHIN RECOMMENDED LIMITS. 3. FINISH COATS: PROVIDE FINISH COATS CAPABLE OF BEING WASHED WITH MILD DETERGENT WITHOUT L055 OF COLOR, SHEEN, OR PIGMENTS, 4. FIN1514 COAT COORDINATION: PROVIDE FINISH COATS WHICH ARE COMPATIBLE WITH PRIME PAINTS, UNDERCOATS, AND BARRIER COATS USED. VOLATILE ORGANIC COMPOUNDS: PROVIDE MATERIALS WITH MINIMAL VOLATILE ORGANIC COMPOUNDS (VOC); COMPLY WITH APPLICABLE REGULATIONS. COLORS AND FINISHES: PURE, NON- FADING, APPLICABLE TYPES TO SUIT SERVICE INDICATED; A. NO LEAD CONTENT PERMITTED. PREPARATION: PERFORM PREPARATION AND CLEANING PROCEDURES IN ACCORDANCE WITH I- PAINT MANUFACTURER'S INSTRUCTIONS AND AS SPECIFIED FOR SUBSTRATE CONDITION. 1. EXAMINE AREAS AND CONDITIONS UNDER WHICH PAINTING WORK 15 TO BE APPLIED. START OF PAINTING WORK INDICATES ACCEPTANCE OF SURFACES AND CONDITIONS OF SURFACES AND CONDITIONS WITHIN ANY PARTICULAR AREA, 2. REMOVE HARDWARE, ACCESSORIES, AND ITEMS IN PLACE AND NOT TO BE PAINTED, OR PROVIDE PROTECTION PRIOR TO SURFACE PREPARATION AND PAINTING; AFTER PAINTING REINSTALL REMOVED ITEMS. APPLICATION: APPLY PAINT IN ACCORDANCE WITH MANUFACTURER'5 DIRECTIONS; USE J. APPLICATORS AND TECHNIQUES BEST SUITED FOR SUBSTRATE AND TYPE OF MATERIAL BEING APPLIED. 1• APPLY ADDITIONAL COATS WHEN STAINS OR BLEMISHES SHOW THROUGH FINAL COAT, UNTIL PAINT IS A UNIFORM FINISH, COLOR AND APPEARANCE. 2• FINISH DOORS ON TOPS, BOTTOMS AND SIDE EDGES SAME AS FACES. PROVIDE EXTRA ATTENTION TO ASSURE DRY FILM THICKNESS AT CORNERS AND CREVICES 15 EQUIVALENT TO THAT OF FLAT SURFACES. 3• PAINT SURFACES BEHIND MOVABLE EQUIPMENT AND FURNITURE SAME AS SIMILAR EXPOSED SURFACES; PAINT SURFACES BEHIND PERMANENTLY -FIXED EQUIPMENT AND FURNITURE WITH PRIME COAT ONLY. 4, PAINT BACK SIDES OF ACCESS PANELS AND REMOVABLE OR HINGED COVERS TO MATCH EXPOSED SURFACES, 5• SAND LIGHTLY BETWEEN EACH SUCCEEDING ENAMEL AND EACH VARNISH GOAT. SCHEDULING PAINTING: APPLY FIRST COAT TO SURFACES THAT HAVE BEEN CLEANED, K. PRETREATED OR PREPARED FOR PAINTING AS SOON AS PRACTICABLE AFTER PREPARATION. 1. ALLOW TIME BETWEEN SUCCESSIVE COATINGS TO PERMIT PROPER DRYING. DO NOT RECOAT UNTIL PAINT FEELS FIRM AND DOES NOT DEFORM OR FEEL STICKY UNDER MODERATE THUMB PRE55URE. MINIMUM COATING T14ICKNE55: APPLY MATERIALS AT NOT LESS THAN MANUFACTURER'S L. RECOMMENDED SPREADING RATE, TO ESTABLISH A TOTAL DRY FILM THICKNESS AS RECOMMENDED BY COATING MANUFACTURER, PRIME COATS: APPLY TO ITEMS NOT PREVIOUSLY PRIMED; REGOAT PRIMED AND SEALED M. SURFACES WHERE THERE IS EVIDENCE OF SUCTION SPOTS OR UNSEALED AREAS IN FIRST COAT. FINISH COATS: PROVIDE EVEN TEXTURE; LEAVE NO LAPS, IRREGULARITY IN TEXTURE, SKID N. MARKS, OR OTHER SURFACE IMPERFECTIONS. PAINT SYSTEMS: PROVIDE MINIMUM TWO COAT PLUS PRIMER SYSTEMS, 0, I. EXT. PAINTED METAL: SEMIGLOSS 100% ACRYLIC. 2. GYPSUM BOARD WALLS: EGGSHELL (SATIN) LATEX EMULSION. 3. GYPSUM BOARD CEILINGS: FLAT LATEX EMULSION. 4 • TOILET R OOM WALLS AND CEILINGS: SEMIGLOSS ACRYLIC ENAMEL. 5• INT. PAINTED METAL: SEMIGLOSS 100% ACRYLIC 6. CONCRETE FLOORS: CLEAR PENETRATING SEAL; ONE COAT SYSTEM ACCEPTABLE. 7. FLOOR STRIPES: TRAFFIC BEARING, NON -SLIP STRIPE PAINT; ONE COAT SYSTEM ACCEPTABLE. 8. SHEENS: COMPLY WITH A5TM D523, REFLECTANCE OF PAINT. GLEAN -UP: DURING PROGRESS OF WORK, REMOVE DISCARDED PAINT MATERIALS, RUBBISH, P. GANS AND RAGS FROM SITE AT END OF EACH WORK DAY. 1. CLEAN GLASS AND PAINT - SPATTERED SURFACES IMMEDIATELY BY PROPER METHODS OF WASHING AND SCRAPING, USING CARE NOT TO SCRATCH OR DAMAGE FIN15HED SURFACES. PROTECTION: PROTECT WORK OF OTHER TRADES, WHETHER TO BE PAINTED OR NOT; Q. CORRECT DAMAGE BY CLEANING, REPAIRING OR REPLACING, AND REPAINTING, AS ACCEPTABLE TO OWNER'S PROJECT MANAGER. 1. PROVIDE 'WET PAINT" SIGNS TO PROTECT NEWLY - PAINTED FINISHES. 2• REMOVE TEMPORARY PROTECTIVE WRAPPINGS PROVIDED BY OTHERS FOR PROTECTION OF THEIR WORK, AFTER COMPLETION OF PAINTING OPERATIONS. REPAIR: AT COMPLETION OF WORK OF OTHER TRADES, TOUCH -UP AND RESTORE DAMAGED R. SURFACES OR DEFACED PAINTED SURFACES. DIVISION 10: SPECIALTIES '0009 r • • r . ..... . • C. •r • r • SECTION 102113.13 - METAL TOILET COMw�, 'ARTMENTS • • ° • • r u • • r r . GENERAL: PROVIDE FLOOR MOUNTED METAL TOILET COMPARTMENTS AND WALL MOUNTED URINAL SCREENS WITH ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATI OORDINATE WITH TOILET ACCESSORIES. • • • • • • r • • r • • w • r • COORDINATE WITH TOILET ACCESSORIES. : •' : w : 0 0 B. COD AND REGULATIONS. COMPLY WITH STATE' AND PEDE01 RMIR >'Ntrs M ENSURI ACCE55 FOR PERSONS WITH DISABILITIES. 0916 ••iJVb • V• • C. SUBMITTAL • SUBMIT PRODUCT DATA, SHOE• DRAWINGS, AN;J SAKI . D. MANUFACTU 5: SANYMETAL, GLOBAL, OR,'FLt1St'.1 METAL{,' E. TYPE: FLOOR UNTIED TOILET PARTITIONS �yND W"'.L,MCLXT 1, �'AL RHN'S. • 1. FINISH: 5 DARD BAKED ENAMEL FINISH COLOR L BY DESIGNER FROM MANUFACTU R'5 FULL LINE OF COLORS. F. PILASTER SHOES: 3' H; ASTM A666, TYPE 302/304, OL ED FINISH; STAINLESS STEEL, G. ATTACHMENTS, SCREWS A BOLTS: STAINLESS ST MP PROOF TYPE; HEAVY DUTY EXTRUDED ALUMINUM BRACK S. H. HARDWARE: MANUFACTURER'S TANDARD CPR E PLATE R SIMIL -,R FINISH. I. HINGES: NON - FERROUS T PIV , AVITY TYPE, ADJUSTABLE FOR DOOR CLOSE POSITIONING. 2, LATCH: SLIDE LATCH; DOOR D EPER WITH RUBBER BUMPER. B. COAT HOOK/BUMPER: CAST CH E PLATED COMBINATION UNIT. 4. WALL BUMPER: CAST A Y HAL NTED RUBBER BUMPER FOR OUTSWINGING DOORS. S. PULLS: COMPLY WUI ENTS FOR ROVIDING ACCESS FOR PERSONS WITH DISABILITIES. I. INTERNAL REINFORCEM OVI INTERNAL REINF EMENT IN AREAS OF ATTACHED HARDWARE AND A I R LOCATIONS OF REINFO EMENT FOR PARTITION MOUNTED WASHR E5 IE5. J. PREPARATION: EX A SIT ONDITIONS TO WHICH WORK TO BE APPLIED; TAKE SITE DIMENSIONS AFFECTING TW WORK, 1. ENSUPWRREC SPACING AND SIZE OF PLUMBING FI RES; TAKE SPECIAL NOTE OF SLXTIRES COMPARTMENTS INDICATED TO BE DES ED FOR PERSONS WITH DI ES 0 ASSURE CLEARANCES COMPLYING WITH A E55 REGULATIONS. K. INSTALLATI : I ALL UNITS IN ACCORDANCE WITH MANUFACTURER R OMMENDATIQNS AND INSTALLA ON INSTRUCTIONS, SECURE, PLUMB, LEVEL, AND SQUAR LEAVE 1/2' SPACE BETWEEN WA , PANELS AND END PILASTERS. i. A UST HINGES TO LOCATE DOORS IN PARTIAL OPEN POSITION WHEN ATCWED, CEPT ADJUST HINGES TO RETURN DOORS TO CLOSED POSITION AT S LLS ESIGNED FOR USE BY PERSONS WITH DISABILITIES. 2. ANCHOR URINAL SCREEN PANELS TO WALLS WITH TWO PANEL BRACKETS. L CLEANING: FIELD TOUCH -UP OF SCRATCHES AND DEFACED FINISHES WILL NOT BE PERMITTED; REPLACE DAMAGED, SCRATCHED AND MARRED DEFECTIVE MATERIALS WITH N UNDAMAGED MATERIALS; REMOVE PROTECTIVE MASKINGS; CLEAN SURFACES FREE OF OIL AND IMPERFECTIONS. SECTION 102613 - CORNER GUARDS A. GENERAL: INSTALL ALUMINUM CORNER GUARDS WITH ATTACHMENT DEVICES AND ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. MANUFACTURERS: PAWLING, NEW YORK METAL OR EQUAL. C. TYPE: ALUMINUM UNITS WITH MILL FINISH. SEE DWGS. D. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS. SECTION 102813 - TOILET ACCESSORIES A. GENERAL: PROVIDE TOILET ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR ENSURING ACCESS FOR PERSONS WITH DISABILITIES. C. MANUFACTURERS: BOBRICK, BRADLEY, OR AMERICAN SPECIALTIES. UM D. MATERIALS: STAINLESS STEEL, ASTM A666, COMMERCIAL GRADE, TYPE 302/304, NUMBER 4 SATIN FINISH, SATIN CHROME ACCEPTABLE WHERE STAINLESS STEEL 15 NOT AVAILABLE FOR ACCESSORY ITEM SCHEDULED; GAGES AS STANDARD WITH MANUFACTURER OF SPECIFIED ITEMS, E. TYPES; STAINLE55 STEEL ACCESSORIES AS INDICATED ON DRAWINGS; PROVIDE GRAB BARS WITH CONCEALED MOUNTING, SIZES AND SHAPES AS INDICATED AND AS REQUIRED BY APPLICABLE CODES AND REGULATIONS, 1. FASTENERS, SCREWS, AND BOLTS: HOT DIP GALVANIZED; AS RECOMMENDED BY ACCESSORY MANUFACTURER FOR COMPONENT AND SUBSTRATE. 2. CONCEALED SURFACES; PRETREAT AND CLEAN, SPRAY APPLY ONE COAT PRIMER AND BAKED ENAMEL FINISH. F. FABRICATION: WELD AND GRIND SMOOTH JOINTS OF FABRICATED COMPONENTS; FORM EXPOSED SURFACES FROM ONE SHEET OF STOCK, FREE OF JOINTS. I. PROVIDE STEEL ANCHOR PLATES AND ANCHOR COMPONENTS FOR INSTALLATION. 2. FABRICATE UNITS WITH TIGHT SEAMS AND JOINTS, EXPOSED EDGES ROLLED; HANG DOORS AND ACCESS PANELS WITH CONTINUOUS PIANO HINGES; PROVIDE CONCEALED ANCHORAGE WHERE POSSIBLE. 3. HOT DIP GALVANIZE FERROUS METAL ANCHORS AND FASTENING DEVICES. A. • AI FORM SURFACES FLAT WITHOUT DISTORTION, MAINTAIN AIN FLAT SURFACES WITHOUT SCRATCHES AND WITHOUT DENTS; FINISH EXP05ED EDGES EASED, FREE OF SHARP EDGES WHERE POTENTIAL EXISTS FOR PHYSICAL CONTACT. 5. SHOP ASSEMBLE COMPONENTS; PACKAGE COMPLETE WITH ANCHORS AND FITTINGS, G. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE CODES AND REGULATIONS• x z 1�ei �-�� A �/Wq1 ,t W �Z�C_" �t r__o Kos }mow° -", � . a ~w= oz a g CCyW�N- UO3 y N2NFP NUO w Agj M - 'N en-:G --- �oz �o- _ N Z3, -12�_ G -� 5, 45HE OK 6WUOWo 29K21C' P 5Z-r,8 €0-6q- y W_�Q _'� �z� ��,=W wNOS F. 3 Ko3w N�wSSR� �I-SS r,nrl KIJ/l�w rZ KjF~rp K -F p r.�oF -o caow°o �., .7 GNLV VJfN OZ s . r- 8 • P X -_gw Zi N «wo Q _. _2r4 0) i N - O CO O `w 0 Y N O '_j T 0 J Q N CITY Or ,43CIL,ITH MIA `� j RE.UIRED BY: REVISIONS: DATE SECTION 105100 - LOCKERS '[WILDING D��S -r. u /0T /n A. GENERAL: INSTALL OWNER FURNISHED METAL LOCKERS; PROVIDE ACCESSORIES �5 REQUIRED FOR COMPLETE FINISHED INSTALLATION. ` ' Ji�A ` =GTJ0t B. INSTALLATION: INSTALL LOCKERS IN ACCORDANCE WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, SECURE, PLUMB, ?'LEVEL; SQUARE, AND IN LINE. �r-" •n,, - y 4 I. BOLT ADJOINING LOCKER UNITS TOGETHER TO PROVIDE RIGID INSTALLATION 1/ 131Y� f _. 2. INSTALL METAL BASES, END PANELS, AND FILLER PANELS TO CL05E OFF OPENINGS AND AS REQUIRED FOR COMPLETE INSTALLATION. SECTION 105628 - MOBILE STORAGE SHELVING A. GENERAL: INSTALL OWNER FURNISHED MOVABLE COMPACT STORAGE SYSTEM; PROVIDE ACCESSORIES AS REQUIRED FOR COMPLETE FINISHED INSTALLATION. B. EXAMINATION: EXAMINE SUBSTRATES AND CONDITIONS UNDER WHICH COMPACTED STORAGE SYSTEM 15 TO BE INSTALLED. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE )SEEN CORRECTED. C. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND INSTALLATION INSTRUGTIONS. I. INSTALL UNITS AND ACCESSORIES AT LOCATIONS SHOWN IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, LEVEL, PLUMB, SECURE AND AT PROPER HEIGHT. 2. INSTALLATION TO BE 5UPERV15ED BY FACTORY TRAINED PERSONNEL; MANUFACTURER REPRESENTATIVE TO MAKE PERIODIC SITE INSPECTIONS OF INSTALLATION WHILE IN PROGRESS. D. CLEANING: CLEAN UNITS AND REPAIR OR REPLACE DAMAGED UNITS AS DIRECTED BY OWNER'S PROJECT MANAGER. TOUCH -UP MARRED FINISHES OR REPLACE COMPONENT PARTS AS NECESSARY TO ELIMINATE EVIDENCE OF DAMAGE OR DETERIORATION. E. PROTECTION: PROVIDE PROTECTION FOR INSTALLED SYSTEM TO ENSURE PERFECT OPERATING CONDITION WITHOUT DAMAGE AT COMPLETION OF PROJECT. SECTION 107313 - AWNINGS A. GENERAL: G.C. TO COORDINATE AWNING AND FRAME INSTALLATION WITH OWNER'S PROJECT MANAGER. SUBCONTRACTOR TO PROVIDE BLOCKING AS REQUIRED PER 5140P DRAWING DETAILS. C` ,_-a X18. Swernshhock, Architect AR#00155 •4 5130 Saabry Road C.r ..... :J;.. ­ 01 -! 4'?f11',)j (,t' -1_A) ""/I- _IC^•'"'1 - iNviCATE$ R• RNsm TO THS WET SHREMSHOCK Shremshock Architects, Inc. Geralel S. Shremshenk, Architect 6130 S. Sunbury Md. Westerville, OH 43091 t: 614 545 4550 , f: 61 4 545 4555 (� U 1- r I - 0 I � . 4: • t, • ku * 1, (-% : 7;