11-354-041SECTION 074213 - METAL WALL PANELS (SNAKE METAL)
A. GENERAL: PROVIDE SHOP FORMED BRAKE METAL PANEL SYSTEM WITH ACCESSORIES AS
REQUIRED FOR COMPLETE FINISHED INSTALLATION.
B. CODES: COMPLY WITH APPLICABLE CODE LOADING REQUIREMENTS
C. SYSTEM DE51GN: DESIGN METAL PANEL SYSTEM TO PROVIDE FOR MOVEMENT OF
COMPONENTS WITHOUT CAUSING BUCKLING, FAILURE OF JOINT SEALS, UNDUE STRESS ON
FASTENERS, OR OTHER DETRIMENTAL AFFECTS.
D. MANUFACTURERS: FIRM WITH MINIMUM FIVE YEARS 5UGGE55FUL EXPERIENCE FABRICATING
METAL PANEL SYSTEM AS INDICATED ON DRAWINGS.
E. METAL PANELS: FORMED BRAKE METAL PANELS AS INDICATED ON DRAWINGS.
I, EXTERIOR METAL: 16 GA. FORMED STEEL PANELS
INTERIOR METAL: .050 THICK, W/ CR15P BRAKES
2• PLYWOOD BACKING: MINIMUM AIDA C -C PLUGGED EXTERIOR GRADE PLYWOOD, 3/4'
THICK UNLESS OTHERWISE NOTED,
3. ADHESIVE: GE1200 TO BE APPLIED IN AN 'S' PATTERN.
A. PANEL FINISH: THERMOSETTING ACRYLIC (BAKED ENAMEL) OR FACTORY FORMULATED
POLYESTER TGIG POWDER COATING MATERIALS INTENDED FOR POWDER COATING
APPLICATION.
5. COLOR: AS INDICATED ON DRAWINGS, AS DIRECTED BY ARCHITECT WHERE NOT
I
OtHERW SE INDICATED.
F. SUPPORTS: CONCEALED IN FINISHED CONSTRUCTION; ASTM A36 SHAPES AND ASTM A570
AND A611 SHEET STEEL, MINIMUM 16 GAGE FURRING STRIPS; MINIMUM A5TM A123 OR A535
610 GALVANIZED FINISH.
G. ACCESSORIES: PROVIDE CONCEALED ANCHORS, CONCEALED FASTENERS, TRIM, AND CUSTOM
PIECES AS REQUIRED FOR COMPLETE, FINISHED INSTALLATION, FREE OF RATTLES AND NOISE
DUE TO THERMAL MOVEMENT AND AIR MOVEMENT.
H. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS.
SECTION 075900 - ROOF REPAIRS
A. GENERALt REPAIR EXISTING ROOFING SYSTEM AS REQUIRED FOR NEW CONSTRUCTION, WITH
COMPONENTS AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION.
B, STANDARDS: CONFORM TO NATIONAL ROOFING CONTRACTOR'S A550CIATION ROOFING AND
WATERPROOFING MANUAL, 4TW OR 5TH EDITION.
C. WARRANTY: MAINTAIN ALL EXISTING WARRANTIES, PROVIDE FOR CORRECTING FAILURE OF
ROOF REPAIRS TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND; WARRANTY
PERIOD OF TWO YEARS.
D. ROOFING SYSTEM: MATCH EXISTING ROOFING, NO SUBSTITUTIONS PERMITTED; PROVIDE
MATERIALS CAPABLE OF MAINTAINING EXISTING WARRANTIES; CONFORM TO REQUIREMENTS OF
NRCA ROOFING MANUAL.
I. SYSTEM: PROVIDE COMPLETE SYSTEM WITH ACCESSORIES AS REQUIRED FOR REPAIRS,
INCLUDING INSULATION WHERE EXISTING ROOFING 15 INSULATED.
E. ROOF SYSTEM REPAIRS: COMPLY WITH MANUFACTURER'S RECOMMENDATIONS AND
INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR ROOF TYPE SPECIFIED.
I. REMOVE EXISTING ROOFING AS REQUIRED FOR PROJECT; REMOVE ONLY AS MUCH
ROOFING AS CAN BE REPLACED IN SAME DAY UNLESS OTHERWISE APPROVED IN
ADVANCE BY OWNER'S PROJECT MANAGER,
2. INSPECT SUBSTRATES AND ROOF DECK TO ENSURE 5UBSTRATE5 AND DECK ARE
CLEAN AND SMOOTH, FREE OF DEPRESSIONS, WAVES OR PROJECTIONS, AND ARE
P TO DRAINS, PROPERLY S LOP D E RA S, VALLEY, OR EAVES,
3. INSULATION APPLICATION: ATTACH INSULATION IN ACCORDANCE WITH INSULATION
MANUFACTURER'S INSTRUCTIONS AND NRCA RECOMMENDATIONS FOR INSTALLATION OF
INSULATION ON DECK INVOLVED,
4. COMPLY WITH MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION OF COMPOSITION
TYPE BASE, WALL AND FIELD FLASHINGS.
5. COORDINATE METAL FLASWINGS AND COUNTERFLASHING.
6. COORDINATE INSTALLATION OF ROOF DRAINS AND RELATED FLA5HINGS.
7. MOP IN AND SEAL FLASWING5 AND FLANGES OF ITEMS PROJECTING T14ROUGW
MEMBRANE.
SECTION 076000 - FLASHING AND SHEET METAL
A. GENERAL, PROVIDE FLASHING AND SHEET METAL, REGLETS, AND ACCESSORIES AS
REQUIRED FOR ROOF REPAIRS AS REQUIRED FOR COMPLETE, WEATHERTIGHT INSTALLATION.
B. STANDARDS: CONFORM TO SMACNA "ARCHITECTURAL SHEET METAL MANUAL" REQUIREMENTS
FOR FLASHING AND SWEET METAL.
C. DESIGN REQUIREMENTS: ALLOW FOR MOVEMENT OF COMPONENTS WITHOUT CAUSING
DUCKLING, FAILURE OF JOINT SEALS, UNDUE STRESS ON FASTENERS OR OTHER DETRIMENTAL
EFFECTS, WHEN SUBJECT TO 100 YEAR SEASONAL TEMPERATURE RANGES.
D. SUBMITTALS: FURNIS14 PRODUCT DATA FOR MANUFACTURED PRODUCTS.
E. WARRANTY: MAINTAIN ALL EXISTING WARRANTIES, CORRECT FAILURE OF METAL FLASHING
SYSTEM TO RESIST PENETRATION OF WATER AND DAMAGE FROM WIND; WARRANTY PERIOD
TWO YEARS,
. F. FLASHING AND SWEET METAL: MATCH EXISTING, BUT NOT LESS THAN FOLLOWING.
i, GALVANIZED METAL FLASHING: ASTM A526 GALVANIZED STEEL WITH MINIMUM 0.02 AND
WITH MINIMUM G90 GALVANIZED COATING; MINIMUM 24 GAGE.
2. PREFINISHED METAL FLASHING: 24 GAGE GALVANIZED STEEL WITH FACTORY FINISHED
KYNAR 500 TYPE FLUOROPOLYMER COATING AND STRIPPABLE PROTECTIVE FILM;
COLOR AS SELECTED FROM MANUFACTURER'S FULL RANGE OF COLORS.
3. ALUMINUM FLASHING: ASTM B201, ALLOY AS REQUIRED TO MATCW FINISH SPECIFIED
FOR OTHER ALUMINUM COMPONENTS; THICKNESS MINIMUM 0.050' AT FLASHINGS.
4. STAINLESS STEEL SWEET METAL. A5TM ill 2D ANNEALED FINISH, SOFT TEMPER
EXCEPT WHERE HARDER TEMPER 15 REQUIRED FOR FORMING OR PERFORMANCE; 0.015"
(26 GAGE) TYPICAL,
5. COPPER SWEET METAL: ASTM 5370, COLD ROLLED 16 OZ, (0.0210) THICK; SOFT
TEMPER WHERE REQUIRED FOR FORMING.
G. REGLETS: FRY /SPRINGLOK OR MM SYSTEMS /SNAP -TITE REGLETS; FABRICATE OF SAME METAL
_ AS ADJACENT FLASHING AND SHEET METAL.
W. METAL TO METAL SEALANT: BUTYL TYPE; NON - STAINING, NON- CORRO51VE, NON- SWRINKING,
NON- SAGGING, ULTRAVIOLET AND OZONE RESISTANT.
1. INSTALLATION: COMPLY WITW 5MACNA MANUAL.
1. INSTALL METAL FLASHING AND SWEET METAL IN ACCORDANCE WITW 5MACNA
ARCHITECTURAL SHEET METAL MANUAL; TIGHT IN PLACE, WITH CORNERS SQUARE,
SURFACES TRUE AND STRAIGHT IN PLANES, AND LINES ACCURATE TO PROFILES AS
INDICATED ON DRAWINGS.
2. INSTALL SEALANTS WHERE REQUIRED TO PREVENT DIRECT WEATHER PENETRATION.
B. COMPLETED INSTALLATION SHALL BE FREE OF RATTLES, NOISE DUE TO THERMAL AND
AIR MOVEMENT, AND WIND WHISTLES,
SECTION 078100 - APPLIED FIREPROOFING
A, GENERAL: PATCH EXISTING FIREPROOFING AS REQUIRED BY APPLICABLE CODES FOR
CONSTRUCTION TYPE; NO ASBESTOS PERMITTED,
B. DESIGN REQUIREMENTS: PROVIDE MATERIALS CAPABLE OF ATTAINING FIRE RATINGS AS
REQUIRED FOR TYPE It FIRE RESISTIVE CONSTRUCTION.
G. PERFORMANCE REQUIREMENTS: PROVIDE MATERIALS LISTED BY UL OR INDEPENDENT
TESTING AND INSPECTION AGENCY ACCEPTABLE TO APPLICABLE AUTHORITIES,
I. FIRE RESISTANCE RATINGS: COMPLY WITW REQUIRED RATINGS BASED ON TESTS IN
ACCORDANCE WITH ASTM E111.
2. SURFACE BURNING CHARACTERISTICS: MAXIMUM 25 FLAME SPREAD AND 25 SMOKE
DENSITY WHEN TESTED IN ACCORDANCE WITH ASTM E84.
D. CERTIFICATE: SUBMIT MANUFACTURER CERTIFICATION INDICATING APPLICATOR
ACCEPTABILITY AND MATERIAL COMPLIANCE WITW APPLICABLE CODES AND CONTRACT
DOCUMENTS.
1. CERTIFICATION SHALL INDICATE NEW MATERIALS USED TO PATCH EXISTING
. FIREPROOFED MEMBERS AT NEW AND EXISTING WORK ARE COMPATIBLE WITH EXISTING
FIREPROOFING MATERIALS AND MEET ALL PERFORMANCE REQUIREMENTS.
E. QUALIFICATION OF APPLICATOR: FIRM ACCEPTABLE TO MANUFACTURER OF FIREPROOFING
MATERIALS, WITH MINIMUM FIVE YEARS SUCCESSFUL EXPERIENCE ON PROJECTS OF
51MILAR SCOPE.
F. MANUFACTURERS /PRODUCTS: MATCH EXISTING BUT NOT LESS THAN W.R. GRACE/ MONOKOTE
OR ALBI MANUFACTURING DIVISION 5TANCHEM/pURASPRAY.
RECOMMENDATIONS AND FIRE TEST
G. INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER REC O
RESULTS AS REQUIRED TO PROVIDE REQUIRED FIRE RATINGS.
I. PROTECT ADJACENT SURFACES AND EQUIPMENT FROM DAMAGE BY OVERSPRAY,
I FALLOUT, AND DUSTING; MASK ADJACENT WORK AS REQUIRED. CLOSE OFF AND SEAL
i DUCT WORK IN AREAS WHERE FIREPROOFING 15 BEING APPLIED,
1 2. CLEAN SUBSTRATE OF DIRT, DUST, GREASE, OIL, LOOSE MATERIAL, PAINTS, PRIMERS,
I F D OF SPRAYED FIREPROOFING.
AND OTHER MATTER WH GH A FECTS BON
i 3. APPLY FIREPROOFING IN SUFFICIENT THICKNESS AND DENSITY TO ACHIEVE REQUIRED
FIRE RATINGS.
A. APPLY FIREPROOFING OVER SUBSTRATE, BUILDING TO REQUIRED THICKNESS WITH AS
MANY PASSES OR STAGES NECESSARY TO COVER WITH MONOLITHIC BLANKET OF
UNIFORM DENSITY AND TEXTURE.
SECTION 078400 - FIRESTOPPING
A, GENERAL: PROVIDE PENETRATION -TYPE FIRESTOPPING FOR TIME -RATED FLOOR, WALL, AND
PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE AND HOT
GASES,
H, CODES! CONFORM TO APPLICABLE CODE REQUIREMENTS FOR BOTH F AND T RATINGS.
C. STANDARDS: PASS ASTM EB14 THROUGH- PENETRATION FIRE STOPS, ASTM i FIRE TESTS
AND ASTM E54 FLAME SPREAD /SMOKE CONTRIBUTION MAXIMUM 25/25.
D. SUBMITTALS: FURNISH SHOP DRAWINGS, PRODUCT DATA, AND CERTIFICATES OF
COMPLIANCE WITH CONTRACT DOCUMENTS AND APPLICABLE CODES.
E. MANUFACTURERS: 3M /FIRE BARRIER, STI /SPECSEAL OR PENSIL, OR WILTI /FIRESTOP
SYSTEMS.
F. GENERAL: CHOOSE PRODUCTS AND METHODS MEETING APPLICABLE CODES AND SPECIFICATION
REQUIREMENTS FOR EACH FIRESTOPPING APPLICATION, SUBJECT TO OWNER'S PROJECT
MANAGER'S ACCEPTANCE, '
G. FIRESTOPPING MATERIALS: FURNISH MATERIALS FOR PENETRATIONS IN TIME -RATED FLOOR,
WALL, AND PARTITION ASSEMBLIES CAPABLE OF PREVENTING PASSAGE OF FLAME, SMOKE,
AND HOT GASES,
I. PENETRATION TEST: FURNISH MATERIALS PASSING ASTM E614 FOR PENETRATION FIRE
STOPPING INDICATING MAINTENANCE OF TIME -RATED ADJACENT ASSEMBLIES.
2. FIRESTOPPING: MAINTAIN FIRE RATING OF ASSE M SLY IN WWICW FIRE5TOPPING 15
INSTALLED, SUCH AS FLOOR, PARTITION, OR WALL, IN ACCORDANCE WITH ASTM Vim
TESTS.
W, INSTALLATION: INSTALL IN ACCORDANCE MANUFACTURER RECOMMENDATIONS AND FIRE TEST
RESULTS AS REQUIRED 70 PROVIDE REQUIRED FIRE RATINGS.
G .
1. FIELD INSPECTIONS: MAINTAIN COPY OF MANUFACTURER'S INSTALLATION INSTRUCTIONS
AND RECOMMENDATIONS AT EACH WORK AREA.
SECTION 079200 - JOINT SEALANTS
A. GENERAL: PROVIDE EXTERIOR AND INTERIOR JOINT SEALERS NOT PROVIDED ELSEWHERE;
TYPE SUITABLE FOR APPLICATION INDICATED WITH ACCESSORIES AS REQUIRED FOR
COMPLETE INSTALLATION.
5. INSTALLER QUALIFICATIONS: FIRM WITH MINIMUM FIVE YEAR'S 5UGGE55FUL EXPERIENCE ON
PROJECTS OF SIMILAR TYPE AND SIZE, U51NG SPECIFIED PRODUCTS,
C. WARRANTY: REPAIR OR REPLACE JOINT SEALERS WWICW FAIL TO PERFORM AS INTENDED,
BECAUSE OF LEAKING, CRUMBLING, HARDENING, SHRINKAGE, BLEEDING, SAGGING, STAINING
AND LOSS OF ADHESION; WARRANTY PERIOD TWO YEARS,
D. EXTERIOR NON - TRAFFIC JOINTS: GE /51LPRUF SCS2700; DOW /7.10 OR 715; OR PECORA/664, LOW
MODULUS SILICONE SEALANT,
f. TRAFFIC BEARING JOINTS: MAMECONULKEM 245, OR PECORA/NR -200 UREXPAN,
MULTI - COMPONENT POLYURETHANE, SELF- LEVELING JOINT SEALER.
F, MILDEW- RE515TANT SANITARY 5EALANT5: GE /SANITARY SEALANT, DOH/BATHTUB CAULK, OR
PECORA/618 TRU- WHITE; PROVIDE AT INTERIOR AREAS WHERE SEALANT WILL BE EXPOSED
TO WATER.
G. GENERAL INTERIOR LATEX OR ACRYLIC EMULSION JOINT SEALER: PECORA /AC -20;
SONNEBORN/SONOLAC.
W. MISCELLANEOUS MATERIALS: PRIMERS, SEALERS, JOINT CLEANERS, BOND BREAKER TAPE,
AND SEALANT BACKER RODS AS RECOMMENDED 5Y SEALANT MANUFACTURER FOR
APPLICATIONS INDICATED.
1. OVERSIZE 15ACKER ROD MINIMUM 30% TO 50% OF
JOINT OPENING
COLORS: AS INDICATED OR AS SELECTED BY OWNER'S PROJECT MANAGER FROM
MANUFACTURER'S FULL RANGE OF COLORS.
J. PREPARATION- GLEAN JOINT SURFACES IMMEDIATELY BEFORE INSTALLATION OF JOINT
SEALER, AND PRIME OR SEAL JOINT SURFACES AS RECOMMENDED BY MANUFACTURER.
K. INSTALLATION: COMPLY WITH MANUFACTURER'S PRINTED INSTALLATION INSTRUCTIONS AND
ASTM C1113,
1. EMPLOY INSTALLATION TECHNIQUES WHICH WILL ENSURE JOINT SEALERS ARE
DEPOSITED IN UNIFORM, CONTINUOUS RIBBONS WITHOUT GAPS OR AIR POCKETS,
WITH COMPLETE "WETTING' OF BOND SURFACES,
DIVISION 08: DOORS AND WINDOWS
SECTION 081100 - METAL DOORS AND FRAMES
I
A. GENERAL: PROVIDE STEEL DOORS AND FRAMES AND ACCESSORIES AS R EQUIRED FOR
COMPLETE INSTALLATION; COORDINATE WITH SECTION 087100 - DOOR HARDWARE.
B. STANDARDS: COMPLY WITH STEEL DOOR INSTITUTE "STANDARD STEEL DOORS AND FRAMES
OR NAAMM HOLLOW METAL MANUFACTURERS ASSOCIATION "HOLLOW METAL MANUAL,"
1, FIRE RATED STANDARDS: FURNISH MATERIALS TESTED, LABELED AND INSPECTED BY
UL, WARNOCK HERSEY, OR TESTING AGENCY ACCEPTABLE TO APPLICABLE
AUTHORITIES,
C. SUBMITTALS. SUBMIT PRODUCT DATA.
D. MANUFACTURERS: AMWELD, CECO, PIONEER, OR APPROVED EQUAL.
E. HOLLOW METAL DOORS: FLUSH HOLLOW METAL DOORS FULL FLUSH TYPE; SDI MODEL I,
NAAMM TYPE B FULL FLUSH WITH UNFILLED EDGE; CLOSE TOP AT EXTERIOR DOORS,
1. CORE: PROVIDE STEEL STIFFENED CORE; INSULATED AT EXTERIOR DOORS.
GAGE: PROVIDE MINIMUM 16 GAGE AT INTERIOR DOORS, MINIMUM 16 GAGE AT EXTERIOR
DOORS.
PRESSED STEEL (HOLLOW METAL) FRAMES: MINIMUM 16 GAGE KNOCK -DOWN
(FIELD- ASSEMBLED) FRAMES.
G. FIRE RATED UNITS: CONFORM TO NFPA 80; PROVIDE UL OR WARNOCK HERSEY LABELED
DOORS AND FRAMES AS REQUIRED.
W. ACCESSORIES: PROVIDE DOOR SILENCERS, ANCHORS, AND ACCESSORIES.
I. FABRICATION: CONFORM TO REQUIREMENTS OF SDI OR NAAMM,
1. DOOR SILENCERS: PLACE MINIMUM THREE SINGLE BUMPERS ON SINGLE DOOR
FRAMES; SPACE EOUA1-1-Y ALONG STRIKE JAMBS; PLACE TWO SINGLE BUMPERS ON
DOUBLE DOOR FRAME HEADS.
J FINISH NT INTERIOR UNITS , GALVANIZE,AND PR IM E P AIN T EXTERIOR UNITS,
MINIMUM A60 GALVANIZING; CLEAN, DEGREASE AND FACTORY PRIME PAINT.
K. INSTALLATION: COMPLY WITW MANUFACTURER RECOMMENDATIONS AND EITHER SDI OR
NAAMM STANDARDS.
1. INSTALL FIRE RATED UNITS IN CONFORMANCE WITH FIRE LABEL REQUIREMENTS AND
NFPA 50.
2. INSTALL DOORS AND FRAMES PLUMB AND SQUARE, AND WITH MAXIMUM DIAGONAL
DISTORTION OF VIC'.
SECTION 051400 - WOOD DOORS
A. GENERAL: INSTALL WOOD DOORS AND WOOD DOOR FRAMES AS REQUIRED FOR COMPLETE
INSTALLATION; COORDINATE WITH HARDWARE IN SECTION 087100.
15. STANDARDS: COMPLY WITH NATIONAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA)
INDUSTRY STANDARDS FOR WOOD DOORS.
C. PROJECT CONDITIONS: DO NOT DELIVER OR INSTALL DOORS UNTIL CONDITIONS FOR
TEMPERATURE ANp RELATIVE HUMIDITY HAVE BEEN STABILIZED IN ACCORDANCE WITH
REFERENCED STANDARDS REQUIREMENTS APPLICABLE TO PROJECT LOCATION,
D H WORKMANSHIP.
I 5 EXHIBITING DEFECTS IN WORK . WARRANTY: PROVIDE FOR REANG NG WOOD DOOR
WARRANTY PERIOD TWO YEARS.
E. INSTALLATION: INSTALL WOOD DOORS IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS AND INSTALLATION INSTRUCTIONS, AND REFERENCE STANDARDS,
PLUMS AND SQUARE, AND WITH MAXIMUM DIAGONAL DISTORTION OF 1/10.
F. PROTECTION: PROTECT DOORS AS RECOMMENDED BY DOOR MANUFACTURER TO ENSURE
DOORS ARE WITHOUT DAMAGE AT TIME OF SUBSTANTIAL COMPLETION.
SECTION 083100 - ACCESS DOORS AND PANELS
A. GENERAL+ PROVIDE ACCESS DOORS AS REQUIRED FOR ACCESS TO VALVES AND CONTROLS
LOCATED BEHIND FINISHED WALLS AND CEILINGS NOT OTHERWISE ACCESSIBLE, WITW
ACCESSORIES FOR COMPLETE INSTALLATION,
I. COORDINATE WITH VARIOUS TRADES FOR CONTROLS AND VALVES WHICH MAY BE
CONCEALED.
B. SUBMITTALS: FURNISH PRODUCT DATA FOR EACH TYPE OF ACCESS DOOR AND PANEL.
C. MANUFACTURERS: MILCOR, J.L INDUSTRIES, OR KARP.
D. TYPE: FLUSH TYPE AT NON FIRE RATED CONSTRUCTION, STANDARD UL APPROVED FRAMED
TYPE AT FIRE RATED CONSTRUCTION; KEY OPERATED.
1. FRAMES- FABRICATE FROM MINIMUM 16 GAGE.
2. DOORS: FLUSH PANEL TYPE, FABRICATE FROM MINIMUM 14 GAGE STEEL,
3. WINGS: PROVIDE CONTINUOUS PIANO TYPE WINCE.
4. FINISH: FINISH WITH MANUFACTURERS FACTORY- APPLIED ENAMEL PRIME COAT APPLIED
OVER PHOSPHATE COATING ON STEEL.
E. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS AND APPLICABLE
REQUIREMENTS FOR FIRE RATINGS.
I. SET FRAMES ACCURATELY IN POSITION AND SECURELY ATTACH TO SUPPORTS WITH
FACE PANELS PLUMS OR LEVEL IN RELATION TO ADJACENT FINISH SURFACES,
2. ADJUST HARDWARE AND DOORS AFTER INSTALLATION FOR PROPER OPERATION.
3. REMOVE AND REPLACE DOORS OR FRAMES WHICH ARE WARPED, BOWED OR OTHERWISE
DAMAGED,
IEC 083326 - OVERHEAD COILING GRILLES It
A. GENERAL: INS OWNER FURNISHED OVERHEAD COILING GRILLE A S RIES
AS REQUIRED FOR TE OPERATIONAL INSTALLATION.
B. ACCESSORIES: COORDINATE EX F MATE FU WED WITH OVERHEAD
COILING GRILLES; PROVIDE ADDITION EQUIRED FOR COMPLETE
OPERATIONAL INSTALLATION.
C. NSTALLATION: INSTALL MPLETE, IN ACCORD ITH MANUFACTURER'S
INSTRUCTIO IONS.
i, F B CATE, AND ADJUST GRILLE ASSEMBLIES L ND PLUME, AND
IDE SMOOTH OPERATION.
da
GENERAL: PROVIDE EXTRUDED ALUMINUM ENTRANCE SYSTEM WITH DOORS, FRAMES, HARDWARE,
AND ACCESSORIES AS REQUIRED FOR COMPLETE WEATHERTIGHT INSTALLATION AT EXTERIOR
LOCATIONS ONLY. ARCH ALUMINUM 0 GLASS CO., INC. WURRICANE- RESISTANT ALUMINUM ENTRANCE
DOOR, GLASS 4 GLAZING, DOOR HARDWARE, AND COMPONENTS
A. MODEL TYPES OF ARCH ALUMINUM ENTRANCES INCLUDE:
I. MEDIUM STILE SWING DOOR AND DOORFRAME
(I 114" WIDE X 4 1/2' DEEP)
2, 7/16" LAMINATED DOOR GLASS
3. MIAMI -DADE COUNTY PRODUCT APPROVAL 15:
NOTICE OF ACCEPTANCE: 01- 1110.04
FLORIDA STATE PRODUCT APPROVAL * 6350.1
B. TYPE OF ARCH ALUMINUM - FRAMED STOREFRONTS INCLUDES:
1. RESISTOR IMPACT SERIES IMPACT WALL 3100/1-3100 - LARGE AND SMALL MISSILE
1 1 14'X 41/2" OFFSET To FRONT, INTERIOR GLAZED SWEAR BLOCK SYSTEM FOR 1 -5/16"
(NOM.) AND /OR 1/16" (NOM.) GLAZING
2• 1- 5/16" LAMINATED INSULATING IMPACT WALL GLASS
3. MIAMI -DADE COUNTY, PRODUCT APPROVAL NOTICE OF ACCEPTANCE 15: 01- 1022.01
FLORIDA STATE PRODUCT APPROVAL 15 # 6217.2 /•
HURRICANE ZONE OF THE FLORIDA BUILDING CODE (FBC). FOR LOCATIONS WHERE T14E PRESSURE
REQUIREMENTS DO NOT EXCEED THE DESIGN PRESSURE RATING VALUES INDICATED IN THE
APPROVED DRAWINGS, REFER TO THE ABOVE REFERENCED NOA DRAWINGS AND CHARTS FOR
ACCEPTED CONFIGURATIONS, LIMITS, ANCHOR REQUIREMENTS, AND ALLOWABLE DOOR HARDWARE.
A. STANDARDS: COMPLY WITH ARCHITECTURAL ALUMINUM MANUFACTURERS ASSOCIATION (AAMA)
'ALUMINUM STORE FRONT AND ENTRANCE MANUAL,'
B. CODES AND REGULATIONS: COMPLY WITH APPLICABLE CODES AND REGULATIONS.
C. SUBMITTALS: FURNISH MANUFACTURER'S LITERATURE, SHOP DRAWINGS, AND SAMPLES.
D. STRUCTURAL CERTIFICATES: PROVIDE CERTIFICATION 15Y STATE REGISTERED ENGINEER
INDICATING SYSTEM COMPLIES WITH CONTRACT DOCUMENTS AND APPLICABLE CODES.
E. SPECIAL PROJECT WARRANTY: PROJECT WARRANTY: REFER TO DIVISION I GENERAL
REQUIREMENTS, WORK COVERED BY CONTRACT DOCUMENTS ?FOR PROJECT WARRANTY
CONDITIONS. MANUFACTURER'S PRODUCT WARRANTY: SUBMIT, FOR OWNER'S ACCEPTANCE,
MANUFACTURER'S PRODUCT WARRANTY FOR ENTRANCE 4 STOREFRONT SYSTEMS AS FOLLOWS:
I. RESISTOR IMPACT DOOR 3000 MEDIUM STILE LARGE MISSILE, HURRICANE - RESISTANT
ENTRANCE DOOR AND GLASS SYSTEMS SHALL BE GUARANTEED AGAINST DEFECTS IN
MATERIALS AND /OR WORKMANSHIP FOR A PERIOD OF TWO (2) YEARS FROM DATE OF
SHIPMENT.
2. THE RESISTOR IMPACT SERIES, IMPACT WALL 3100/1-3100 - LARGE AND SMALL MISSILE
ALUMINUM STOREFRONT FRAMING AND GLASS SYSTEM SHALL BE GUARANTEED BY
LIMITED WARRANTY AGAINST DEFECTS IN MATERIALS AND /OR WORKMAN 5141 P AS DEFINED
BY MANUFACTURER'S PUBLISHED LIMITED WARRANTY FOR A PERIOD OF TWO (2) YEARS
FROM DATE OF SHIPMENT.
3. T14E 1 -5/16" LAMINATED INSULATING IMPACT WALL GLA55 WALL BE GUARANTEED BY
LIMITED WARRANTY AGAINST DEFECTS IN MATERIALS AND /OR WORKMANSHIP AS
DEFINED 5Y MANUFACTURER'S PUBLISHED LIMITED WARRANTY FOR A PERIOD OF FIVE (5)
YEARS.
F. MANUFACTURER: ARCH ALUMINUM 4 GLASS CO. INC., 10200 N.W. 67TH STREET, TAMARAC, FL
33321 CONTACT: DAN LUNA 800 -432 -8132
G. ALUMINUM - FRAMED ENTRANCES t STOREFRONTS
1. DOOR AND FRAME SECTIONS SHALL CONFORM TO THE MATERIAL STANDARDS OF ASTM 5
221; 6063 - T5 ALLOY 4 TEMPER
2. T14E DOOR STILE AND RAIL PROFILE DIMENSIONS FOR T14E RESISTOR IMPACT SERIES,
IMPACT DOOR 3000 MEDIUM STILE LARGE MI551LE 514ALL BE:
m. VERTICAL STILES: 3 1/2"
Ir. TOP RAIL: 3 1/2"
c. BOTTOM RAIL: 10'
B. MAJOR PORTIONS OF T14E DOOR STILES AND RAILS ARE TO BE .125" IN NOMINAL
7 ES T E . 1
4. E F E PR FILE DIMENSIONS WILL BE-
E I AL t HORIZONTAL MULLIONS: 1 114' X 4 1/2'. HORIZONTAL FOR CONCEALED
OVERHEAD CLOSER: 13/4' X 4 1/2 ".
5, OINT ALA : SEE ECTIO 07'120
H. GLAZING: E 5 ION 100.
1. GLAZING ACCESSORIES: SEE SECTION 066100.
J. MISCELLANEOUS MATERIALS:
I. STEEL REINFORCEMENT AND BRACKETS: MANUFACTURER'S STANDARD WITH MINIMUM 2 OZ.
NOT -DIP ZINC COATING, ASTM A123, APPLIED AFTER FABRICATION.
2. BITUMINOUS PAINT- COLD- APPLIED MASTIC, 55PC PAINT 12, COMPOUNDED FOR 30 MIL
THICKNESS PER GOAT
3. FLASHING: SEE SECTION 076000.
4. ANG14ORING DEVICES. CORROSION RESISTANT TYPE CAPABLE OF SUPPORTING
ENTRANCE SYSTEM AND SUPERIMPOSED DESIGN LOADS; DESIGN TO ALLOW
ADJUSTMENTS OF SYSTEM PRIOR TO BEING PERMANENTLY FASTENED IN PLACE.
K. FABRICATION: FABRICATE ALUMINUM ENTRANCE AND STOREFRONT SYSTEM TO ALLOW FOR
CLEARANCES AND SHIM SPACING AROUND PERIMETER OF ASSEMBLIES TO ENABLE
INSTALLATION; PROVIDE FOR THERMAL MOVEMENT.
I. ACCURATELY FIT TOGETHER JOINTS AND CORNERS; MATCH COMPONENTS ENSURING
CONTINUITY OF LINE AND DESIGN; ENSURE JOINTS AND CONNECTIONS ARE FLUSH,
HAIRLINE AND WEATHERPROOF.
2. SEPARATE D1551MILAR MATERIALS WITH BITUMINOUS PAINT OR PREFORMED
SEPARATORS WHICH WILL PREVENT CORROSION,
L. INSTALLATION: INSTALL ALUMINUM FRAMED STOREFRONT ASSEMBLIES, INCLUDING ENTRANCES, IN
ACCORDANCE WIT14 MANUFACTURER'S RECOMMENDATIONS AND TO MEET DESIGN REQUIREMENTS
INDICATED, FOR WEATHERTIGHT INSTALLATION..
1. ENSURE A55EMBLIE5 ARE PLUMS, LEVEL AND FREE OF WARP OR TWIST; MAINTAIN
DIMENSIONAL TOLERANCES AND ALIGNMENT WITH ADJACENT WORK.
2. USE SUFFICIENT ANCHORAGE DEVICES TO SECURELY AND RIGIDLY FASTEN ASSEMBLIES
TO BUILDING.
3. INSTALL HARDWARE IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, USING
PROPER TEMPLATES. COORDINATE INSTALLATION OF CYLINDERS WITH SECTION 087100•
4. INSTALL SILL MEMBERS AND THRESHOLDS IN BED OF COMPOUND, JOINT FILLERS OR
GASKETS TO PROVIDE WEAT14ERTIGWT CONSTRUCTION,
5, GLASS INSTALLATION: COMPLY WITW GANA GLAZING MANUAL AND GLAZING
MANUFACTURER INSTRUCTIONS, DO NOT ALLOW GLASS TO TOUCH METAL SURFACES.
SECTION 064126 - ALL-GLASS ENTRANCES AND STOREFRONTS
GENERAL: SECTION INCLUDES: PROVIDE SPECIAL FRAMELESS ALL -GLASS ENTRANCES
AND STOREFRONTS, INCLUDING SAFETY GLASS DOORS, RELATED HARDWARE, ADJA NT
LAZING AND ACCESSORIES AS REQUIRED FOR COMPLETE, OPERATIONAL INSTAL ION.
RELATED WORK: SECTION 087100: CYLINDERS FOR DOOR LOCKS.
B. RE RENCE5
1. G 55 ASSOCIATION OF NORTH AMERICA (GANA): GLAZING MA L.
2. BU ERS HARDWARE MANUFACTURERS A550CIATION (BHMA 13 / AN51
A156.18, TANDARDS FOR MATERIALS A ND FINISHES.
C. SYSTEM D CRIPTION
1. PERFOR GE REQUIREMENTS. PROVIDE ASSEMBLIES G OF IT14STANDING
MINIMUM UNI RM TEST PRESSURE OF 20 PSF INWARD W D PRESSURE WHEN
TESTED) IN A RDANCE WITH ASTM E330.
D. SUBMITTALS t 1
1. PRODUCT DATA: URNISH MANUFACTURER'S LIT
2, SHOP DRAWINGS: DICATE COMPONENT DETAI TE LS, FINISHES, DIMENSIONS,
HARDWARE AND FITTI S, AND METHOD OF A E.
3. SAMPLES- FURNISH 5 PLES OF METAL FIN
E. QUALITY ASSURANCE
1. INSTALLER QUALIFICATIO : FIRM WITH IMUM E YEARS SUCCESSFUL
EXPERIENCE IN INSTALLATIO F ENTRA�Ill R TO THOSE SPECIFIED; APPROVED
BY SYSTEM MANUFACTURER.
2. REGULATORY REQUIREMENTS: TH EQUIREMENTS OF APPLICABLE BUILDING
CODES AND AMERICANS WITH DIS 5 T ACCE551BILITY GUIDELINES (ADAAG)
TO ENSURE ACCESS TO PERSON DI BILITIES,
F. PROJECT CONDITIONS
1, CHECK OPENINGS BY FIEL MEASURE TS BEFORE FABRICATION TO ENSURE
PROPER FITTING AND TIGH T5; 00 INATE FABRICATION WIT14 SHOP DRAWINGS
OF ADJACENT CONSTRUC �rNECE5 RY TO AVOID DELAYS,
G. MANUFACTURERS:
1, SEE ARCHITEGTU IN
2. SUBSTITUTIONS: E TO ECTION 016200
H. MATERIALS:
1, ALL-GLASS E E STEMS: PROVIDE COMPL E SYSTEM,
a. GLA55: E THAN NOMINAL 1/2" THICK AS INDICATED ON DRAWINGS,
LOW -IRON, 5ELE GLAZING QUALITY CLEAR TEMP ED GLA55 COMPLYING WITH
AST 8, KI FT.
FET GLASS: CONFORM TO ANSI Z17.1 AND PLICABLE CODES AND
U IONS.
. P VIDE HORIZONTALLY TEMPERED GLA55 WITNQ TONG MARKS;
VE ICAL TEMPERING PERMITTED ONLY WHERE TONG RKS CAN BE
ALLY CONCEALED IN FIN15WED INSTALLATION,
POLISH SIDE EDGES TO BE EXPOSED OR TO RECEIVE 5 LANT; CUT
GLA55 TO TOL)~1RANGES NECESSARY TO PROVIDE EVEN, vb' OINTS WITHIN
PLUS OR MINUS 1/16 ".
6, DOOR FITTINGS: PROVIDE CUSTOM "PATCH" TYPE FITTINGS A INDICATED
ON DRAWINGS AND AS REQUIRED TO SUPPORT DOORS,
1. FINISH: REFER TO DOOR SCHEDULE
c. FRAMELESS GLASS DOOR HARDWARE: MANUFACTURER'S STANDARD MET AND
FINISH TO MATCH DOOR RAILS, UNLESS OTHERWISE INDICATED. REFER TO
ARCHITECTURAL DRAWINGS.
d. ANCHORAGES AND FASTENINGS: MANUFACTURER'S STANDARD TYPES,
CONGEALED EXCEPT A5 OTHERWISE REQUIRED; FINISH EXPOSED FASTENE TO
MATCH ADJACENT METAL SURFACES.
. SEALANT: HIGH MODULUS STRUCTURAL SILICONE DESIGN 5 UGTURAL
ZING.
1. SEALANT COLOR: CLEAR
MANUFACTURERS:
A. DOW CORNING /SILICONE RUBBER SEAL
. GENERAL ELECTRIC /SILICONE CONG G5 1200 SEALANT.
C. ECORA /b63 GLAZING SILICONE.
D. EMCO /PROGLAZE 51LICONE.
E. 5U TITUTIONS: REFER TO 30
f. SIDELIGHT GLAZI CHANNELS: FINISH DOOR PATCHES; SIZED A5
REQUIRED TO 5UPP0 GLA55;
1. EXPOSED FINIS , ATCH FI H FOR R SYSTEM.
J. FABRICATION
1. LOCATE AND PROVIDE HOLES S TO RECEIVE HARDWARE BEFORE
TEMPERING GLASS; DO NOT PE G, DRILLING OR OTHER GLASS
ALTERATIONS AFTER TEMPERI
a. POLISH EXPOSED ENDS 0 55; OUND EDGES SLIGHTLY.
2. FABRICATE ALL-GLASEdENTRA SYST TO ACCOMMODATE REQUIRED HARDWARE
AND ACCESSORY ITEM
PLANT; T 0 FINAL I A N MOVE ONLY A5 REQUIRED FOR F
3. INSTALL HARDWA C T
FINISHING OPERAT OR DELIVERY AND I ALLATION OF WORK AT PROJECT
SITE,
K. EXAMINATION
1. EXAMINE A CONDITIONS UNDER WHICH WORK TO BE INSTALLED.
2. BEGIN NJ LATION SIGNIFIES ACCEPTANCE OF CON TIONS.
L. INSTALLATION
1. CO WIT MANUFACTURER'S RECOMMENDATIONS AND INST LATION
IN .
N N
1� IN IN ACCORDANCE WITH MANUFACTURER'S IN RUCTIONS AND
'f ALL GLAZING T
A GLAZING MANUAL.
2, UNITS PLUMB, LEVEL AND TRUE TO LINE, WITHOUT WARP OR RA - ANCHOR
5E RELY IN PLACE,
SEPARATE ALUMINUM AND OTHER CORRODIBLE METAL SURFACES FROM 5 CES OF
CORROSION OR ELECTROLYTIC ACTION AT POINTS OF CONTACT WITW OTHER
MATERIALS.
. ADJUSTING: ADJUST OPERATING HARDWARE TO ENSURE PROPER OPERATION.
N. CLEANING: CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED CLEANING METHOD .
SECTION 087100 - DOOR HARDWARE
A GENERAL: PROVIDE DOOR HARDWARE FOR HOLLOW METAL DOORS AND FOR WOOD DOORS,
AND PROVIDE CYLINDERS FOR DOORS PROVIDED WITH HARDWARE, WITH ACCESSORIES AS
REQUIRED FOR COMPLETE OPERATIONAL DOOR INSTALLATIONS,
B. STANDARDS: COMPLY WITH BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)
ANSI /BHMA 156 5ERIE5 STANDARDS.
C. CODES AND REGULATIONS: COMPLY WITH STATE AND FEDERAL REQUIREMENTS FOR
ENSURING ACCESS FOR PERSONS WITH DISABILITIES.
FIRE RATED DOORS: COMPLY WITH REQUIREMENTS OF NFPA 60 AND APPLICABLE CODES
FOR FIRE RATED DOOR HARDWARE; PROVIDE HARDWARE BEARING UNDERWRITERS
LABORATORY (UL) LABELS.
D. SUBMITTALS: FURNISH SHOP DRAWINGS, PRODUCT DATA INCLUDING KEYING SCHEDULE, AND
5AMPLE5 OF EACH REQUIRED STYLE AND FINISH,
1. SUPPLY TEMPLATES TO DOOR AND FRAME MANUFACTURERS FOR PROPER AND
ACCURATE SIZING AND LOCATIONS OF CUT -OUTS FOR HARDWARE.
Z G T
E. GENERAL MATERIALS: PROVIDE COMPLETE HARDWARE WITH ACCESSORIES AS REQUIRED F OR
DOORS AND APPLICATIONS INDICATED AND NOT PROVIDED UNDER OTHER SECTIONS.
F, HINGES: WAGER, LAWRENCE, MCKINNEY, OR STANLEY; FULL MORTISED BUTT HINGES; SIZE
AND NUMBER AS RECOMMENDED BY MANUFACTURER; NONREMOVABLE PINS AT EXTERIOR
OUTSWINGING DOORS, BALL- BEARING WINGES AT FIRE RATED DOORS AND DOORS WITH
CLOSERS,
G, LOCK5ETS /LATCW5ET5: SCHILAGE, SARGENT, YALE, SIMPLEX OR U- CHANGE; FULL MORTISE
LOCKSETS TYPICAL AT DOORS TO PUBLIC AREAS, CYLINDRICAL LOCKSETS AND
LATGHSETS AT OTHER LOCATIONS; SOLID LEVER TYPE WITW ROSE; KEYING AS DIRECTED
BY OWNER; PROVIDE CYLINDERS . FOR DOORS FUR NISH ED WI H T LOCK 5 U CHANGE /
SECURITY SYSTEMS CUSTOMER SERVICE: 1 -600- 253 - 5625),
P. PUSWBUTTON ACCESS CONTROL LOCK5ET MANUFACTURER: SIMPLEX LI071 AT SPECIAL PUBLIC
DOOR ROOM ONLY, KEY OVERRIDE, PRIVACY FUNCTION, HANDLE STYLE WL LEVER, FINISH
26D SATIN CHROME, PACKAGING 41 - I PER BOX. USE ONLY IF DWGS. SPECIFY.
OVERHEAD CLOSERS: LCN /4000 SERIES OR NORTON/7500 FULLY ADJUSTABLE; MODERN TYPE
WITH COVER,
J. ACCESSORIES: PROVIDE DOOR STOPS, THRESHOLDS, WEATHERSTRIPPING, TRIM,
COORDINATORS AND ACCESSORIES AS REQUIRED FOR COMPLETE OPERATIONAL
DOOR INSTALLATION.
I, THRESHOLDS, STOPS, TRIM, AND MISCELLANEOUS WARDWARE1 PROVIDE AS INDICATED,
AS SPECIFIED, AS INCLUDED IN HARDWARE SCHEDULE, AND AS REQUIRED FOR
COMPLETE INSTALLATION,
2. WEATHERSTRIPPING: PROVIDE CONTINUOUS WEATHERSTRIPPING AT TOP AND SIDES OF
EXTERIOR DOORS.
3. FIRE RATED GASKETS: PROVIDE CONTINUOUS FIRE RATED GASKETS AT TOP AND SIDES
OF FIRE RATED DOORS.
4. THROUGH BOLTS: THROUGH BOLTS AND GROMMET NUTS SHALL BE AVOIDED ON DOOR
FACES IN HIGHLY VISIBLE AREAS, UNLESS NO ALTERNATIVE 15 POSSIBLE, AS
DIRECTED AND APPROVED, AND SHALL NOT BE USED FOR SOLID WOOD CORE DOORS.
K. FINISH: 13WMA 626 (US26D), SATIN FINISHED CHROMIUM PLATED UNLESS OTHERWISE
INDICATED.
L. INSTALLATION: COMPLY WITH MANUFACTURER RECOMMENDATIONS, BHMA, AND APPLICABLE
REQUIREMENTS FOR ACCESS AND FOR FIRE RATINGS.
1. FIT HARDWARE PRIOR TO PAINTING, THEN REMOVE FOR PAINTING OF DOORS AND
FRAMES BEFORE FINAL INSTALLATION OF HARDWARE.
2. WEIGHTS TO COMPLY WITW APPLICABLE CODES AND 5HMA RECOMMENDATIONS.
3. HARDWARE GROUPS: REFER TO DRAWINGS.
SECTION 088100
A. GENE L: INSTALL GLASS; PROVIDE GLAZING ACC S5ORIE5 AS REQUIRED FOR COMPLETE
INSTA LATION.
B. STAND : COMP Y WIT GIBS ASS IATION F NORTW AMERICA (GANA) "GLAZING MANUAL ",
G. CODES :SAF WI NUUBER PRODUCT STANDARD W. Cl 1201, AND
SHALL HAVE PASSED ANSI Z'17.1.
D. SUBMITTALS: FURNISH PRODUCT DATA AND SAMPLES OF EXPOSED GLAZING MATERIALS.
E. MANUFACTURERS: PILKINGTON (1.411,2473731), GUARDIAN (1.248.340,1800), OR
PPG (l,bbb.774.4332) OR APPROVED EQUAL.
F. GLAZING: ASTM 61046, KIND FT, FULLY TEMPERED SELECT GLAZING QUALITY GL
GLAS5; A " S Y 55 U 5 I
1. TER10 , I/2" 5/6 OR 3/4" THI K TEMPERED GLAZING, AS INDICATED ON DRAWINGS.
2. EXTERIOR: 1 5/16' INSULATING LAMINATED GLASS (MAKEUP: 1/4" CLEAR TEMPERED,
I/2 "
SP AC ER 1/10 L AMINATED
1-A55 WITH I14 A
C
LEAR HEAT STRENGTHENED GLASS,
,0'0- PV13 INTERLAYER, 1 14' CLEAR HEAT STRENGTHENED GLASS)
XPOS AND UT ESS I ED
4 ER ES: - CO RS
H EXPOSED EDGES POLISHED
G. GLAZING ACCESSORIES: OF TYPE RECOMMENDED 5Y MANUFACTURER TO SUIT SECURITY
LOCATIONS AND APPLICATIONS FOR DRY GLAZING INSTALLATION.
H. WINDDORNE- DEBRIS- IMPACT RESISTANCE: PROVIDE EXTERIOR GLAZING THAT PA55E5 5A51C
PROTECTION TESTING REQUIREMENTS IN ASTM E 1116 FOR APPROPRIATE WIND ZONE WHEN
TESTED ACCORDING TO ASTM E 1666. TEST SPECIMENS SHALL BE NO SMALLER IN WIDTH AND
LENGTH THAN GLAZING INDICATED FOR USE ON THE PROJECT AND 544ALL BE INSTALLED IN
SAME MANNER A5 GLAZING INDICATED FOR USE ON THE PROJECT.
i, LARGE - MISSILE TEST: FOR GLAZING LOCATED WITHIN 30 FEET (1.Im) OF GRADE.
2. SMALL- MISSILE TEST: FOR GLAZING LOCATED MORE THAN 30 FEET (1.1m) ABOVE GRADE.
3. LARGE- MISSILE TEST: FOR ALL GLAZING, REGARDLESS OF WEIGHT A50VE GRADE.
I. WINDBORNE- DEBRIS- IMPACT - RESISTANT LAMINATED GLASS: ASTM C 1172, AND COMPLYING WITH
TESTING REQUIREMENTS IN 16 CFR 1201 FOR CATEGORY II MATERIALS, WITH
u
WINDBORNE- DEBRIS - IMPACT RESISTANCE"
PARAGR A PH ABOVE, AND WITH OTHER REQUIREMENTS
SPECIFIED, USE MATERIALS THAT HAVE A PROVEN RECORD OF NO TENDENCY TO BUBBLE,
DISCOLOR, OR L05E PHYSICAL AND MECHANICAL PROPERTIES AFTER FABRICATION AND
INSTALLATION.
1. CONSTRUCTION: LAMINATE GLASS WITH THE FOLLOWING TO COMPLY WITH INTERLAYER
MANUFACTURER'S WRITTEN RECOMMENDATIONS:
a. POLYVINYL BUTYRAL INTERLAYER,
2, INTERLAYER THICKNESS: PROVIDE THICKNESS NOT LESS THAN THAT INDICATED AND AS
E G R IRE T
1, 3. III AVER COLOR: CLEAR UNLESS OT ERWIS INDICATED,
J. GLAZING SEALANT: DOW- CORNING 115 SILICONE GLAZING SEALANT.
K. SETTING BLOCKS AND SPACERS: NEOPRENE OR EPDM, 51LICONE COMPATIBLE WHERE IN CONTAC
ITH S (GONE EALA .
L. P : C G G NE ND MI M T CE LA
IMMEDIATELY BEFORE GLAZING; REMOVE COATINGS NOT FIRMLY 50NDED TO SUBSTRATE.
M. INSTALLATION: COMPLY WITW GANA GLAZING MANUAL AND SEALANT MANUAL AND GLAZING
MANUFACTURER INSTRUCTIONS.
1. DO NOT ALLOW GLASS TO TOUCH METAL SURFACES,
2, COMPLY WITH NFPA 60 FOR GLASS IN FIRE RATED OPENINGS.
3. PLACE SETTING BLOCKS AT QUARTER POINTS IN TWIN COURSE OF SEALANT.
4. INSTALL REMOVABLE STOPS WITW GLASS CENTERED IN SPACE WITH SPACER SHIMS AT
2' -0' INTERVALS ON 50TH SIDES OF GLASS, 1/4" 5ELOW SIGHTLINE.
5, SEALANT GLAZING- FILL GAP BETWEEN GLASS AND STOPS WITW SEALANT TO DEPTH
EQUAL TO 51TE OF FRAME ON GLASS BUT NOT MORE THAN 3/5" BELOW SIGHTLINE,
SECTION 088300 - MIRRORS
A. SUMMARY: THIS SECTION INCLUDES NEW INAtJ h)OUN'��ED GLAWN, ROR�. : • • • w
• • • Y Y • V � W
• • . r Y •
B. QUALITY ASSURANCE • • • • • • • •
I. INSTALLER QUALIFICATIONS: AN EXPERIENCED INSTALLER WHO HAS COMPLETED MIRROR
GLAZING SIMILAR IN MATERIAL, DESIGN, "AND, EXTENTYTO T,AAT mr -AT0; WHOSE
55 THAN 5
WORK HAS RESULTED IN MIRROR INSTA�L�,T�JN,� Wltw A R,�GOP_.D'"C�F NOT LE. T
YEARS OF SUCCESSFUL IN- SERVICE PERFGRMACE. ; 0 & r
•
• YfW •Y• •ff YYf
2. SOURCE LIMITATIONS FOR MIRRORS: 05TAIN MIRRORS FROM ONE
SUPPLIER/MANUFACTURER FOR EACH TYPE OF MIRROR INDICATED.
U 1 f Y N v r .+ ....
3. SOURCE LIMITATIONS FOR GLAZING k-MOORIE5: ,.�03TAIN, GLAZING ACCESSORIES FROM
ONE SOURCE FOR EACH TYPE OF ACCESSORY INDICATED.: • r
• 0 W •
4, GLAZING PUBLICATIONS: COMPLY WITW THE APPLICABLE RECOMMENDATIONS OF THE
FOLLOWING. WHERE RECOMMENDATIONS CONFLICT THE MORE STRINGENT 514ALL APPLY:
A. GLASS ASSOCIATION OF NORTH AMERICA (GANA): "GLAZING MANUAL"
AND THE MIRROR DIVISION'S "MIRRORS, HANDLE WITH EXTREME CARE:
TIPS FOR THE PROFESSIONAL ON THE CARE AND HANDLING OF MIRRORS."
B. NATIONAL GLASS ASSOCIATION (NGA): "CUSTOM MIRRORS,
FABRICATION AND INSTALLATION.
G. DELIVERY, STORAGE,
AND HANDLING.
1, PROTECT MIRRORS ACCORDING TO MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS
AND AS NEEDED TO PREVENT DAMAGE TO MIRRORS FROM CONDENSATION,
TEMPERATURE CHANGES, DIRECT EXPOSURE TO SUN, OR OTHER CAUSES,
2. COMPLY WITH MIRROR MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SHIPPING,
STORING, AND HANDLING MIRRORS AS NEEDED TO PREVENT DETERIORATION OF
SILVERING, DAMAGE TO EDGES, AND ABRASION OF GLASS SURFACES AND APPLIED
COATINGS, STORE INDOORS, PROTECTED FROM MOISTURE INCLUDING CONDENSATION.
D. PROJECTION CONDITIONS: ENVIRONMENTAL LIMITATIONS - DO NOT INSTALL MIRRORED
GLASS UNTIL AMBIENT TEMPERATURE AND HUMIDITY CONDITIONS ARE MAINTAINED AT
LEVELS INDICATED FOR FINAL OCCUPANCY.
E. SILVERED FLAT GLASS MIRROR MATERIAL: 6,0 mm THICK AND COMPLYING WITH ASTM C
1503, MIRROR SELECT QUALITY FOR USE IN VISUALLY DEMANDING APPLICATIONS REQUIRING
MINIMAL DISTORTIONS AND BLEMISHES,
F. FABRICATION
I, CUTOUTS: FABRICATE CUTOUTS FOR NOTCHES AND HOLES IN MIRRORS WITHOUT
MARRING VISIBLE SURFACES, LOCATE AND SIZE CUTOUTS SO THEY FIT CLOSELY
AROUND PENETRATIONS IN MIRRORS,
2. MIRROR EDGE TREATMENT:
A. CUTTING AND POLISHING--
1, TYPICAL MIRRORS: FLAT EDGES WHERE THE CLEAN CUT 'SQUARE'
EDGE OF THE GLA55 15 FLAT AND SURFACE EDGES ARE SLIGHTLY
ARRISSED. AFTER GRINDING THE ARIS5ES, EDGES SHALL BE
POLISHED TO A HIGH GLOSS SURFACE WHERE TOE SURFACE
REFLECTIVITY 15 SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF
THE GLAS5,
2. BEVELED EDGED MIRRORS: PROVIDE BEVELED EDGED MIRRORS
WHERE THE SURFACE EDGE OF THE GLASS IS BEVELED TO WIDTH
INDICATED ON T14E OWNER FURNISHED DRAWINGS. THE ANGLE FORMED
BY THE INTERSECTION OF THE PLANE OF THE BEVEL WITH THE MAJOR
SURFACE FACE OF THE GLASS SHALL BE BETWEEN 3 TO 10 DEGREES.
THE BEVELED SURFACE AND TWE N05E OF THE BEVEL 5WALL BE
POLISHED TO A HIGH GLOSS SURFACE WHERE THE SURFACE
REFLECTIVITY 15 SIMILAR IN APPEARANCE TO THE MAJOR SURFACE OF
THE GLASS.
3. EDGE SEALING! IMMEDIATELY AFTER CUTTING THE FINAL SIZES, AND
APPLYING EDGE TREATMENT, FACTORY SEAL EDGES OF MIRRORS WITW
EDGE SEALER TO PREVENT CHEMICAL OR ATMOSPHERIC PENETRATION
OF GLASS COATING,
G. MISCELLANEOUS MATERIALS
I. SETTING BLOCKS: NON- RUBBER OR NON- NEOPRENE 15ASED ELASTOMERIC MATERIAL
MANUFACTURED FOR SETTING SILVERED FLAT GLA55 MIRRORS, COMPATIBLE WITH
ADHESIVE USED FOR PLACEMENT, WITH A TYPE A SWORE DUROMETER HARDNESS
OF 85, PLUS OR MINUS 5. 1/6" WIDE x 114" HIGH x 4" LONG.
2. EDGE SEALER: COATING COMPATIBLE WITH GLASS COATING AND APPROVED BY
MIRROR MANUFACTURER FOR USE IN PROTECTING AGAINST SILVER DETERIORATION
AT MIRROR EDGES.
3. MIRROR MASTIC: PALMER "QWICKSET MIRRO- MASTIC "; PALMER PRODUCTS CORP.
(502) 8'13 -3668 OR (800) 431 -6151 / FAX (502) 815 -1253 I ,
4. DRYWALL AND PLYWOOD PAINT (POROUS SUBSTRATE PRIMER): "KILLZ ORIGINAL"
(OIL BASED PRIMER) FROM MASTERC14EM (OR APPROVED EQUAL)
5. TOP AND BOTTOM ALUMINUM J CHANNELS: ALUMINUM EXTRU51ONS WITH A RETURN
DEEP ENOUGH TO PRODUCE A GLAZING CHANNEL TO ACCOMMODATE G:mm THICK
MIRRORS AND HEAVY BODIED MIRROR MASTIC SPECIFIED AND IN LENGTHS REQUIRED
TO COVER BOTTOM AND TOP EDGES OF EACH MIRROR IN A SINGLE PIECE. THE ENDS
OF THE BACK LIPS OF ALL CHANNELS SHALL BE FACTORY SNIPPED AND FILED 50
TWAT THEY WILL NOT BE SEEN AFTER INSULATION.
A. BOTTOM TRIM: C.R. LAURENCE CO. INC., 114" STANDARD 'J" CHANNEL
(CATALOG NUMBER Dil POLISHED FINISH), (600)421 -6144, FAX (600)262 -3211,
J- CHANNELS FORMED WITH FRONT LEG AND BACK LEG NOT LESS THAN 3/6"
AND 7/6" IN HEIGHT, RESPECTIVELY.
5. TOP TRIM: C.R. LAURENCE CO, INC,, 114' DEEP NOSE "J' CHANNEL (CATALOG
NUMBER D645P POLISHED FINISH) (600)421 -6144 /FAX (600)262 -3211.
J- CHANNELS FORMED WITW FRONT LEG AND BACK LEG NOT LESS THAN 5/8"
AND 1- 3116" IN HEIGHT, RESPECTIVELY.
6. STUD FASTENERS: PROVIDE $6 GAGE DIAMETER, 1 -5/e" LONG, PHILLIPS BUGLE HEAD,
SELF- DRILLING TYPE, FINE THREADED STEEL SCREW FASTENERS IN QUANTITY AS
REQUIRED FOR SUPPORT AND FASTENING OF WOOD TRIMS AND MIRROR CHANNELS TO
DRYWALL STUD FRAMING AND SHEET METAL BACKER PLATES. WILTI KWIK -PRO SELF
DRILL DRYWALL SCREWS, ORDERING NAME: 6X 1'5/8 P5W 5D, ITEM #: 00066216; HILTI
CORPORATION (800) 671 -8000.
7, PLASTIC WOOD FILLER: COMMERCIAL QUALITY WOOD FILLER SPECIFICALLY
MANUFACTURED TO ADVANCE T14E FINAL BUILD AND SMOOTHNESS OF TWE INSTALLED
WOOD TRIM SURFACE BY FILLING DENTS, SCRATCHES, MITER JOINTS, AND VOIDS
A5OVE COUNTERSUNK FASTENER HEADS. THE SELECTED FILLER 514ALL BE EITHER
NEUTRAL OR TINTED TO MATCH THE COLOR OF T14E WOOD TRIM,
S. PLYWOOD FASTENERS: PROVIDE MINIMUM $4 GAGE DIAMETER, PHILLIPS FLAT HEAD,
SHARP POINTED, COARSE THREADED, STEEL WOOD SCREW FASTENERS IN QUANTITY AS
REQUIRED. FURNISH PLYWOOD FASTENERS IN LENGTH AS REQUIRED TO SPAN
THROUGH WOOD MIRROR TRIM, AND MIRROR CHANNELS, PLUS 314 ".
H. 1, WOOD MIRROR TRIM,
EXAMINATION
I. EXAMINE SUBSTRATES, OVER WHICH MIRRORS ARE TO BE MOUNTED, WITH INSTALLER
PRESENT, FOR COMPLIANCE WITH INSTALLATION TOLERANCES, SUBSTRATE
PREPARATION, AND OTHER CONDITIONS AFFECTING PERFORMANCE.
A. VERIFY COMPATIBILITY AND SUITABILITY OF SUBSTRATES, INCLUDING
COMPATIBILITY OF MIRROR MASTIC WITH EXISTING FINISHES OR PRIMERS.
PROCEED WITH MIRRORED GLASS INSTALLATION ONLY AFTER UNSATISFACTORY
J CONDITIONS HAVE BEEN CORRECTED AND SURFACES ARE DRY.
PREPARATION
I. COMPLY WITW MASTIC MANUFACTURER'S WRITTEN INSTALLATION INSTRUCTIONS FOR
PREPARATION OF SUBSTRATES.
A. MIRROR, DRYWALL AND PLYWOOD SUBSTRATES 514ALL BE FREE OF DUST, BE
CLEAN, AND DRY PRIOR TO APPLICATION OF MIRROR MASTIC AND DRYWALL
AND PLYWOOD PAINT, IF PLYWOOD OR DRYWALL SURFACES HAVE BEEN
PAINTED PRIOR TO APPLICATION OF T14E SPECIFIED DRYWALL AND PLYWOOD
PAINT THE EXISTING PAINT SHALL BE SANDED THROUGH T14E ORIGINAL
SURFACE AND THE SUBSTRATE CLEANED PRIOR TO THE APPLICATION OF
K DRYWALL AND PLYWOOD PAINT.
GLAZING
1. GENERAL: INSTALL MIRRORS WITW MIRROR GLAZING CHANNELS TO COMPLY WITH
WRITTEN INSTRUCTIONS OF MIRROR AND MIRROR GLAZING CHANNEL MANUFACTURERS,
WITW REFERENCED GANA AND NGA PUBLICATIONS, OWNER FURNISHED DRAWINGS, AND
AS SPECIFIED. MOUNT MIRRORS PLUMB, IN LINE AND IN A MANNER THAT AVOIDS
DISTORTING REFLECTED IMAGES. CITY O r Sill Ix IA N11 ,
I"1UIi DIN0, DEPT.
'".(,`Tl..,fC'1"'1.�R ",/1k �!"Ii
;PPOVL.D ray .
...n/�)) .- �,.....�,,,,,, r.
:.H r � Il
_.
6 &fold S. t-hrel•I shock, Architect
6130 SLlnhi Read
%7will"
7
FZ <y! O K
-• K
w ° �iW - 0_ wwfd In
o K z
c -_ A --O: °�i #;
�,D. WM# ow ^r9 tfl �g �E�:o,
� �1. 0 r. w° �
( ..� W - i !q__-1j
.n - .r5- w o?� !3
<dVU ,z = -z
<
Z Uz w W.-P _9
o
x_131" to '. NFU - -.,
i w Z
,=g i
WS9
ili��EIIG
°`Ylw dower.+ `'�Fiix�
1M�� %� 8ipbb
O" m w W 5 p 0 �� `i
`�w l E F-i •,x
w
mop : 3o
WwA Fi- U -v � c �
y. <Nuio
" It - a N� 2- - mow=
f, u W T
r . - - LN Lq p Z em � = �w
V° ' W
S
W _
Ill
N � O
r
� N O
(4 0
O
0.. J -
O
Z 1
4 i
L.
Q
w
.1
O•
ll 0 i