11-198-0071 1 • J f i All : I c J I I i I ELECTRICAL SPECIFICATIONS 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH THE ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE NEC 2008, FBC 2007, FFPC 2007, NFPA 72 2002, LOCAL CODES, ORDINANCES, INCLUDING ALL AMENDMENTS TO THE N.E.C.. EQUIPMENT, WHERE APPLICABLE, WILL BE LISTED WITH THE UNDERWRITERS LABORATORIES, INC. QUALITY AND WORKMANSHIP ESTABLISHED BY DRAWINGS AND SPECIFICATIONS ARE NOT TO BE REDUCED BY THE ABOVE MENTIONED CODES. 2. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST -CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND ACCEPTANCE OF THIS SYSTEM BY THE ENGINEER MUST BE A CONDITION OF THE SUB CONTRACT. 4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 7. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 8. CONTRACTOR TO PAY FOR ALL PERMITS, FEES INSPECTIONS AND TESTINGS. 9. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND TELEPHONE COMPANIES. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL POWER AND TELEPHONE COMPANIES PRIOR TO START OF CONSTRUCTION. 10. ALL WIRING SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL AREA OF BE #12 AWG, EXCLUDING CONTROL WIRING. ALL CONDUCTORS SHALL BE COPPER WITH WORK L_ THWN/THHN INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID; ALL THOSE #8 AND LARGER TO BE STRANDED. 11. ALL UNDERGROUND RACEWAYS SHALL BE MINIMUM 3/4 ", GALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY WITH GOVERNING CODES. WHERE RIGID STEEL IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST RESISTANT BITUMASTIC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. RIGID STEEL SHALL ALSO BE USED WHEN CONDUIT IS EXPOSED TO EXTERIOR ENVIRONMENT SUCH AS EXTERIOR OF BUILDING OR WHERE IT IS EXPOSED AND SUBJECT TO DAMAGE, INSIDE OF BUILDING. 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. ALL BOXES SHALL BE RECESSED (FLUSH) IN WALLS OR CEILINGS WHENEVER POSSIBLE. 13. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK -MAKE, QUICK -BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.C. AND LOCATION (WEATHERPROOF, EXPLOSION PROOF, ETC.). ENGRAVED LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED ON ALL DISCONNECT SWITCHES, CONTACTORS AND STARTERS. 14. ALL FUSES FOR SAFETY SWITCHES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE FUSES SHALL BE THOSE MANUFACTURED BY EITHER BUSSMAN OR LITTLEFUSE. THE CONTRACTOR SHALL FURNISH TO THE OWNER ONE SPARE FUSE FOR EACH SIZE AND TYPE OF FUSE INSTALLED. FUSES 600 AMPS OR LESS SHALL BE CLASS RK1, TYPICAL UNLESS OTHERWISE NOTED. FUSES OVER 600 AMPS SHALL BE CLASS L 15. ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. CATALOG NUMBERS LISTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES BY PASS do SEYMOUR, BRYANT. OR ARROW HART WILL BE ACCEPTED. COLOR OF DEVICES AND PLATES SHALL BE WHITE UNLESS DICTATED OTHERWISE BY ARCHITECT /OWNER. A. SWITCHES: LEVITON JCSB1 -20W B. RECEPTACLES: LEVITON IBR20 -W C. COVER PLATES: SMOOTH PLASTIC NOTE ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. 16. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT BE PLACED IN PROPER WORKING ORDER. 17. A SEPARATE, GREEN TYPE THWN COPPER GROUND CONDUCTOR SHALL BE RUN FROM GROUND LUG OF EACH GROUNDED RECEPTACLE TO AN APPROVED CONNECTION INSIDE THE ENCLOSING STEEL OUTLET BOX. DEVICE MOUNTING SCREWS SHALL NOT BE CONSIDERED AN APPROVED GROUND. A SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT AND RACEWAY AND SECURELY BONDED IN AN APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RUN. THE GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH TABLE 250 -122 OF THE N.E.C. CONTRACTOR SHALL SIZE CONDUIT TO ACCOMMODATE ADDITIONAL CONDUCTOR. 18. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME OF DESIGN. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. 19. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR IS TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. 20. FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING, AND CONNECTIONS ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING FROM C.U.TO A.H.U. ,TERMINATION SHALL BE PERFORMED BY MECHANICAL CONTRACTOR. 21. ALL FLUORESCENT LIGHT FIXTURES SHALL HAVE IN LINE FUSING AND ENERGY SAVING BALLASTS. (ONLY REQUIRED IN MIAMI DADE COUNTY) 22. ALL SWITCHGEAR, PANELS, STARTERS, CONTACTORS ETC., SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, THE SYSTEM DESIGN IS BASED ON SQUARE "D "; HOWEVER, COMPARABLE EQUIPMENT BY G.E. do SIEMENS ONLY WILL BE ACCEPTABLE TANDEM AND HALF -SPACE CIRCUIT BREAKERS SHALL NOT BE USED. PANEL SCHEDULE LB (SEC 2) Rated Voltage: 2771480V 3PHAW Manufacture: EXISTING Mounting: SURFACE Rated Amps: (Cu bus) 200A SPACES: 42 Location: SEE FLOOR PLAN Type: NEMA 1 Main: MLO Project No: 11002.00 A.I.C: EXISTING KVA KVA CONDUIT SIZE CIRCUIT DESIGNATION O.C.P. AWG MAX DIST.(ft) VOLT DROP RCPT LGT /HEAT MOTOR PH RCPT LGT /HEAT MOTOR MAX. DIST.(ft) VOLT DROP AWG O.C.P. CIRCUIT DESIGNATION 1 1/2* 1 EXISTING LIGHTING 20/1 12 351 3% 2.00 2.10 A 2.00 2.10 351 3% 12 20/1 EXISTING LIGHTING 2 3 EXISTING LIGHTING 20/1 12 351 3% 5' -0" TO 6' -0" A.F.G. 2.00 GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. THERE SHALL BE NO TYPE 'NM', ELECTRICAL B 2.00 2.10 351 3% 12 20/1 EXISTING LIGHTING 4 5 EXISTING LIGHTING 20/1 12 351 3% 2.00 C REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND CONDUIT FILL 2.00 502 351 3% 12 20/1 EXISTING LIGHTING 6 7 EXISTING LIGHTING 20/1 12 351 3% I, 2.00 PHASE A - BLACK PHASE A - BLACK PHASE A - BROWN LEFT TO RIGHT, FRONT PHASE B - RED PHASE B - ORANGE PHASE B - PURPLE TO BACK A ® 2.00 TRANSIENT VOLTAGE SURGE SUPPRESSOR INTERMATIC SEE PNL SCHEDULE FOR MDL 351 1 3% 1 12 20/1 1 EXISTING LIGHTING 8 9 EXISTING LIGHTING 20/1 12 351 3% 7.47 2.00 B 7.47 2.00 UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, 351 3% 12 20/1 EXISTING LIGHTING 10 11 EXISTING LIGHTING 20/1 12 351 3% 16 2.00 C 7.47 2.00 351 3% 12 20/1 EXISTING LIGHTING 12 13 EXISTING LIGHTING 2011 12 351 3% A 2.00 A 349 2.00 8 351 3% 12 20/1 EXISTING LIGHTING 14 15 EXISTING LIGHTING 20/1 12 351 3% 23 2.00 B C 2.00 351 3% 12 20/1 EXISTING LIGHTING 16 171 EXISTING LIGHTING 20/1 1 12 351 3% 2.00 2.00 2.50 C 3% 2.00 70/3 1 351 3% 1 12 20/1 1 EXISTING LIGHTING 18 19 EXISTING LIGHTING 20/1 12 351 3% 9.00 2.00 3.00 A 2.00 2.00 2.50 351 3% 12 20/1 EXISTING LIGHTING 20 21 EXISTING LIGHTING 20/1 12 351 3% 2.00 502 B 12 2.00 FAN 5HP 351 3% 12 20/1 EXISTING LIGHTING 22 23 EXISTING LIGHTING 20/1 12 351 3% 4.00 1 200 C C 2.00 36 351 3% 12 20/1 EXISTING LIGHTING 24 25 EXISTING LIGHTING 20/1 12 351 3% 2.10 2.00 3% A 20/3 2.00 38 351 3% 12 20/1 EXISTING LIGHTING 26 27 EXISTING LIGHTING 20/1 12 351 3% 2.10 2.00 41 B 45/1 200 78 351 3% 12 20/1 EXISTING LIGHTING 28 29 EXISTING LIGHTING 20/1 12 351 3% SEE RISER 2.00 C 300 1.00 1.00 SEE RISER 100/3 PANEL'3H' 30 31 EXISTING LIGHTING 20/1 12 351 3% 1.00 2.00 A 300 1.00 1.00 • 32 33 CORRIDOR/SPACE C11B LIGHTS 2011 12 334 3% 1.00 2.10 1 B 3.00 1.00 1.00 34 - 35 ----------- - - - - -- SPACE - - -- - -- - -- -- - - - -- - - -- - - - -- C 6.0 0.0 77.5 : SUBTOTAL CONNECTED LOAD SPACE 36 37 SPACE A SPACE 38 39 SPACE B SPACE 40 411 SPACE C SPACE 42 SUBTOTAL CONNECTED LOAD: 0.0 34.1 0.0 1 9.0 31.0 3.0 : SUBTOTAL CONNECTED LOAD note 1 � enfv ma \. O C. P. D �\ ith nameplate note 2 lockable circtul breaker note 3 non - concurrent load note 4 G F.0 I. t.pe circuit breaker note 5 photo cell controlled SEE SECTION 1 note 6 time siNitch controlled note 7 mechamcalh- held lighting contactor BRANCH CIRCUIT CONDUIT SIZE WIRE SIZE CONDUIT SIZE 12-------------------- MAX. DIST.(ft) ----------- ----- 10------------------------------- --------- - ---- _x/26 .... _.......... ................ ----------------- 8 .........0 311C 6 3 e 4 1' 3...................... I .................... 2 -------- - - - - -- - - -V ------ - - - - -- 1 1/2" 1 1 1/2* 23. PROVIDE IDENTIFICATION FOR ALL PANELS, CABINETS, ENCLOSURES, DISCONNECTS do TRANSFORMERS USING ENGRAVED NAMEPLATES, WHITE LETTERING ON A BLACK BACKGROUND. NAMEPLATES SHALL IDENTIFY O.C.P. PANEL DESIGNATION (NAME,) VOLTAGE, PHASE do WIRE CONFIGURATION. PROVIDE TYPEWRITTEN DIRECTORIES MAX. DIST.(ft) UNDER PLASTIC COVER FOR ALL PANEL BRANCH CIRCUITS, CLEARLY INDICATING AREA AND TYPE OF LOAD RCPT BRANCH CKT PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED WILL NOT MOTOR gSEERAVEED��BpY�E�ACH 24. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED RCPT RISER DIAGRAM LEGEND ON ALL PANELS AND SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. 25. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RIGID STEEL ELBOWS AND RIGID STEEL SYMBOL DESCRIPTION SECTIONS AT SLAB PENETRATIONS WHERE SUBJECT TO POSSIBLE DAMAGE. WHERE RIGID STEEL CIRCUIT DESIGNATION REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. 1 rxn ' 20/3 LOADCENTERS - QO PANELBOARD - NQOD 277/480 PANELBOARD - NF IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST - RESISTANT BITUMASTIC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. 26. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL POWER COMPANY AT THE SITE PRIOR TO CONSTRUCTION. AT THAT TIME, THE CONTRACTOR SHALL COORDINATE Na , 2.10 (PNLS SHALL BE MTD ® +60 " A.F.F. U.N.D) 2.10 502 3% ALL RELATED WORK WITH THE UTILITY COMPANY'S RESPONSIBILITIES TO MEET THE OWNER'S SCHED. 20/3 ® 2 METER MLO 27. ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, RIGID 2.10 „o, 5' -0" TO 6' -0" A.F.G. FEED THRU BUS GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. THERE SHALL BE NO TYPE 'NM', ELECTRICAL 5 2.10 C 2.10 6 NON - METALLIC TUBING, do FLEXIBLE METAL CONDUIT USED FOR BRANCH CIRCUITING. MAXIMUM NUMBER OF 120V CIRCUITS ALLOWED IN A COMMON CONDUIT SHALL BE SIX (6). "MC" TYPE CABLE 20/3 12 1464 FUSED DISCONNECT SHALL NOT BE USED AS HOME RUNS. THE CONTRACTOR SHALL STRICTLY CONFORM TO THE N.E.C. 0.83 5' -0" TO 6' -0" A.F.G. REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND CONDUIT FILL 2.10 502 3% 12 20/3 B 8 MAIN CIRCUIT BREAKER DISCONNECT 28. CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: 208V SYSTEM 240V (HIGH LEG) SYSTEM 480V SYSTEM PHASE SEQUENCE NEUTRAL - WHITE NEUTRAL -WHITE NEUTRAL - WHITE /STRIPE ABC, TOP TO BOTTOM 083 B 5' -0" TO 6' -0" A.F.G. I, GROUND SYSTEM PHASE A - BLACK PHASE A - BLACK PHASE A - BROWN LEFT TO RIGHT, FRONT PHASE B - RED PHASE B - ORANGE PHASE B - PURPLE TO BACK PHASE C - BLUE PHASE C - BLUE PHASE C - YELLOW GRD.CON - GREEN GRD.CON - GREEN GRD.CON - GREEN ® 0.83 TRANSIENT VOLTAGE SURGE SUPPRESSOR INTERMATIC SEE PNL SCHEDULE FOR MDL LIGHTING CONTACTOR (MECHANICAL LATCH) 29. CONTRACTOR SHALL BE RESPONSIBLE FOR SEALING ALL CONDUIT PENETRATIONS MADE THROUGH FIRE RATED WALLS, CEILINGS, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L ASSEMBLY STANDARDS. 13 ESCALATOR 15HP O TIME- SWITCH BY INTERMATIC 30. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DRAWINGS AT JOB SITE WITH -------------- --------- ------ MDL#ET70815CR. - ---------------------------------------._---------__---_------_------------ ._.------------- __ - - - - -_ COLORED MARKINGS INDICATING PROGRESS OF WORK. THIS SET OF CONTRACT DRAWINGS IS TO BE SEPARATE FROM AND IN ADDITION TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF 7.47 EXISTING TO REMAIN EQUIPMENT, DEVICE, CONDUIT AND WIRE IS TO MARKED WHEN INSTALLED. USE GREEN TO INDICATE INSTALLATION AS SHOWN ON DRAWINGS AND USE BEM TO INDICATE FIELD CHANGES. 7.47 BOLD LINES DENOTE NEW WORK OR EQUIPMENT UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, 8 AND BECOME PROPERTY OF THE ELECTRICAL ENGINEER. w,nu,En 31. IF ELECTRICAL CONTRACTOR HAS QUESTIONS, OR IN THEIR OPINION FINDS OMISSIONS OR rn/u�srasMex ERRORS ON ELECTRICAL DOCUMENTS, IT IS THEIR RESPONSIBILITY TO BRING THIS TO THE ATTENTION OF THE ELECTRICAL ENGINEER IMMEDIATELY. IF ELECTRICAL CONTRACTOR PROCEEDS WITH &ff CHANGES TO THE CONTRACT DOCUMENTS, WITHOUT WRITTEN PRIOR APPROVAL FROM THE ELECTRICAL ENGINEER, CONTRACTOR WILL NOT BE COMPENSATED. 480A V TO 208Y/120 V DRY TYPE TRANSF. VOLTAGE DROP CALCULATIONS 1. 3% VOLTAGE DROP CALCULATED FOR EVERY BRANCH CIRCUIT SHOWS MAXIMUM DISTANCE ALLOWED FOR THE SPECIFIED WIRE SIZE BASED ON DESIGNED LOAD. 2. ALL CIRCUITS HAVE BEEN VERIFIED ON FLOOR PLANS BASED ON HORIZONTAL STRAIGHT RUNS WITH ADDITIONAL 30 FEET OF VERTICAL RUNS. ACTUAL DISTANCES FOR EVERY CIRCUIT RUN SHALL BE FIELD MEASURED BY THE ELECTRICAL CONTRACTOR. CONTRACTOR SHALL PROVIDE NEXT WIRE SIZE FOR RUNS OVER MAXIMUM DISTANCE SHOWN ON PANEL SCHEDULES. PANEL SCHEDULE HHB (SEC 1) Rated Voltage: 277/480V 3PHAW Manufacture: EXISTING Mounting: SURFACE Rated Amps: (Cu bus) 400A SPACES: 42 Location: SEE FLOOR PLAN Type: NEMA 1 Main: MLO (WITH FEED THRU) Project No: 11002.00 A.I.C: EXISTING KVA KVA CIRCUIT DESIGNATION O.C.P. AWG MAX. DIST.(ft) VOLT DROP RCPT LGT /HEAT MOTOR PH RCPT LGT /HEAT MOTOR MAX DIST.(H) VOLT DROP AWG O.C.P. CIRCUIT DESIGNATION REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. 1 FAN 5HP 20/3 12 579 3% 2.10 A 2.10 502 3% 12 20/3 FAN 5HP 2 3 2.10 B 2.10 4 5 2.10 C 2.10 6 7 FAN 1.5HP 20/3 12 1464 3% 0.83 A 2.10 502 3% 12 20/3 FAN 5HP 8 9 083 B 2.10 10 11 0.83 C 2.10 12 13 ESCALATOR 15HP 40/3 8 402 3% 7.47 A 7.47 349 3% 8 40/3 ESCALATOR 15HP 14 15 7.47 B 7.47 16 17 7.47 C 7.47 18 19 ESCALATOR 15HP 40/3 8 402 3% 7.47 A 7.47 349 3% 8 40/3 ESCALATOR 15HP 20 21 7.47 B 7.47 22 23 7.47 C 7.47 24 25 PANEL'HLB' (SUBFEED SPACE) 175/3 SEE RISER 9.00 5.00 3.00 A 2.00 2.50 1352 3% 4 70/3 PANEL THB' 26 27 9.00 5.00 3.00 B 2.00 2.50 28 29 9.00 5.00 3.00 C 2.00 2.50 30 31 ATS 100/3 SEE RISER 6.00 4.00 2.00 A 2.10 502 3% 12 20/3 FAN 5HP 32 33 6.00 4.00 200 B 2.10 34 35 6.00 4.00 2.00 C 2.10 36 37 EWH 25/1 10 288 3% 4.00 A 2.10 502 3% 12 20/3 FAN 5HP 38 39 EWH 25/1 10 288 3% 400 B 2.10 40 41 EWH 45/1 12 78 3% 9.00 C 2.10 42 PANLE 'LB' (SEC 2) FEED THRU 20/2 SEE RISER 300 23.00 1 00 A 300 23.10 1.00 B 3.00 1900 1.00 C SUBTOTAL CONNECTED LOAD: 54.0 92.1 88.6 6.0 0.0 77.5 : SUBTOTAL CONNECTED LOAD CONNECTED LOAD PHASE A: 93.7 CONTINUOUS & LARGEST MOTOR @ 25 %: 23.0 note 1 %enf}• max O C.P.D NNnh nameplate CONNECTED LOAD PHASE B: 93.8 CONNECTED MOTOR LOADS @ 100 %: 166.1 note 2 lockable circtnt breaker CONNECTED LOAD PHASE C: 94.7 CONNECTED LIGHTING LOAD @100 %: 92.1 note 3 non- concurrent load TOTAL CONNECTED LOAD: 282.2 note 4 G F C.I. type circuit breaker RECEPT. CONNECTED LOAD: 60.0 RECEPEPTACLE COMPUTED LOAD: 35.0 note 5 photo cell controlled TOTAL COMPUTED LOAD: 316 KVA note timesx), itch controlled 380 AMPS note 7 mechanicalh, held hght,ng contactor MAIN ELECTRICAL ROOM ��--- I NEW SPACE 'C11B' em 10 ion EXISTIGN ELECTRICAL RISER " ° " °' "" N.T.S. =.E TO THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED HEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE APPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF 'HENZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSION OF HENZ ENGINEERING INC. 1, THOMAS E. HENZ, P.E. #34261, CERTIFY THAT 1 CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE ELECTRICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AU PNr 3880 TO PROVIDE THE ENGINEERING SERVICE. flFnZ FnG1nFFR1nG, In cons l inG Ef1GIf Tins 2320 NE 9th Street, Suite 200 Fort Lauderdale, Florida 33304 T 954.523.4933 F 954.523.5052 PROJECT No.: 11002.00 architect NORBERTO ROSENSTEIN ARCHITECT , INC. 126 S. FEDERAL HIGHWAY SUITE # 202 DAN IA �BEACH, FLORDA 33004 PH: (954) 922 -&9 FAX: (954) 922 -7388 EMALWooroe otakwchfieCI.COm WEB WWWJ u11ArchReCLem STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYINGWT 020M NORDERTO IRDUMTEIN APX:G CTECT, INC. ALL 11R6G4T8 IESERVED. TFQB DOCUMENT OR PARTS THMOP, MAY NOT ISE REPRIODUCED IN ANY FORM UTWOUT PER R19000N. DESIGNED WARNING! ' '�� '••. / v ',,;.; •; MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL TH u 1 --(( COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL FE,SSION 1rTNEER Nt�34�6 REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE ' F; ORI O ` PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. i` ''•4� CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING ' �r PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF n ' REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. 'DATE. t- I r flFnZ FnG1nFFR1nG, In cons l inG Ef1GIf Tins 2320 NE 9th Street, Suite 200 Fort Lauderdale, Florida 33304 T 954.523.4933 F 954.523.5052 PROJECT No.: 11002.00 architect NORBERTO ROSENSTEIN ARCHITECT , INC. 126 S. FEDERAL HIGHWAY SUITE # 202 DAN IA �BEACH, FLORDA 33004 PH: (954) 922 -&9 FAX: (954) 922 -7388 EMALWooroe otakwchfieCI.COm WEB WWWJ u11ArchReCLem STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYINGWT 020M NORDERTO IRDUMTEIN APX:G CTECT, INC. ALL 11R6G4T8 IESERVED. TFQB DOCUMENT OR PARTS THMOP, MAY NOT ISE REPRIODUCED IN ANY FORM UTWOUT PER R19000N. DESIGNED AS `! DRAWN AS CHECKED TEH - I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. R E V I S 1 0 N S COMM. 2011 -12 DATE 1/4/2011 5701 SUNSET DR SUITES C11A AND C11B WHITE BOX SOUTH MIAMI FLORIDA, 33143 ELECTRICAL SPECS, RISER AND SCHEDULES E -2 2