Loading...
11-198-006I GENERAL DEMOLITION NOTES: I 1 ANY SALVAGE RESULTING FROM CLEARING, GRUBBING, GRADING, DRAINING, REMODELING OR ALTERING ANY EXISTING FACILITIESON THIS SITE SHALL BE THE PROPERTY OF THE OWNER. THIS MATERIAL SHALL BE PILED OR STACKED ON THE SITE IF THE OWNER DESIRES THIS MATERIAL IF THIS MATERIAL IS NOT DESIRED BY THE OWNER, IT SHALL BE DISPOSED OF BY THE CONTRACTOR AT HIS EXSPENSE. THIS INCLUDES, BUT IS NOT LIMITED TO AC UNITS, CABINETRY, AND LIGHTING FIXTURES. 2 THE CONTRACTOR SHALL SEND PROPER NOTICES. MAKE ALL NECESSARY ARRANGEMENTS AND PERFORM ALL OTHER SERVICES REQUIRED FOR THE CASE. PROTECTION AND MAINTENANCE OF ALL PUBLIC UTILITIES. INCLUDING MAIL BOXES, FIRE PLUGS, TELEPHONE POLES AND WIRE, AND ALL OTHER ITEMS OF THIS CHARACTER ON OR AROUND THE SITE. 3 THE CONTRACTOR SHALL KEEP THE PREMISES FREE FROM ACCUMULATION OF WASTE MATERIAL AND RUBBISH AND AT THE COMPLETION OF THE WORK HE SHALL MOVE FROM THE PREMISES ALL RUBBISH. IMPLIMENTS AND SURPLUS MATERIALS AND LEAVE THE BUILDING BROOM CLEAN. 4 THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INCIDENTAL TO PATCHING UP ALL CUTS, OPENINGS, DAMAGED AREAS, ETC. THAT OCCUR AS A RESULT OR WORK UNDER THIS CONTRACT. ALL PATCHING SHALL CONFORM TO THE ADJOINING WORK, MATCHING THE FINISH AND QUALITY OF WORKMANSHIP AND MATERIALS. 5 DISCONNECT ALL ELECTRICAL OUTLET BOXES AND SWITCHES IN DEMOLISHED AREAS TO NEAREST JUNCTION BOX NOT AFFECTED BY DEMOLITION. 6 TELEPHONE SYSTEM DEMOLITION: DISCONNECT TO NEAREST TERMINAL BOARD NOT UNDER DEMOLITION. RE— CONDUIT NEW LINES TO NEW LOCATIONS FROM CLOSEST EXISTING TERMINAL BOARD. 7 FIRE ALARM DEMOLITION: IN CASE OF TOTAL DEMOLITION, DISCONNECT TO NEAREST TERMINAL CABINET. IN CASE OF REMOVAL AND RELOCATION, DISCONNECT TO NEAREST JUNCTION BOX UNLESS EXISTING WIRE CAN BE PROPERLY EXTENDED TO NEW LOCATION WITHOUT SPLICING. LIGHT FIXTURE LEGEND SYMBOL DESCRIPTION CEILING MTD. EXIT SIGN W/ BATTERY BACK UP AND WITH SELF DIAGNOSTICS. B LITHONIA MDL #LQM S W 3R 120/277 EL N SD OR EQUAL HATCH AREA INDICATES FACE OF SIGN EMER. LIGHTING FIXTURE W/ BATTERY BACK UP. AND WITH SELF DIAGNOSTICS. (PROVIDE LITHONIA MR24 LAMPS 1 0/2771OR QUAD FRM,U.N.D) -------------------------------------------------------------------------------------------------------------------------------------------------------------------------- jEMERGENCY LIGHTING FIXTURE W/ BATTERY PACK AND WITH SELF DIAGNOSTICS. MULE LIGHTING MDL#SQRXU /SD ................... .... .. ................................................................................................................... ......................... . . . . .. LIGHT SWITCH ( +48' A.F.F. TO TOP. U.N.D) 3 WAY LIGHT SWITCH ( +48' A.F.F, TO TOP. U.N.D) ------------------ - - - - -- ------------------------------------------------------------------------------------------------------------------- ---- --------------------- - - - --- ® MULTI- TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR SENSORSWITCH, MDL# CM PDT 10 WH _ PROVIDE POWER PACK MDL# PP20 - -� - - - -- --------- - - - - -- -- - - .....- .__.._......... - - - -- - ------------------------------------------------------ EXHAUST FAN (SEE MECHANICAL PLANS FOR SPECS) ------------------ - - - - -- ------------------------------------------------------------------------------------------------------------------- ------------------------- ------ ® CEILING MTD. DUPLEX NOTES 1. NOT ALL SYMBOLS MAY APPEAR ON PLANS. 2.IF THERE IS NO DESIGNATION NEXT TO FIXTURE, THEN ASSUME R IS A NEW FD(TURE. F NOT EXISTING, LOCATE R AS SHOWN ON PLANS. 3. PROVIDE A DISCONNECTING MEANS FOR ALL DOUBLE ENDED FLUORESCENT LAMPS WITH BALLAST AS PER NEC41&73(G). DESIGNATION / DESCRIPTION +84` DENOTES HEIGHT ABOVE A DO � FIXTURE TO BE DISCONNECTED FINISHED FLOOR AFCI ARC FAULT CIRCUIT INTERRUPT UND UNLESS NOTED DIFFERENTLY GFCI GROUND FAULT CIRCUIT INTERRUPT NA NIGHT LIGHT WP WEATHER PROOF ENCLOSURE T/S TIME SWITCH IG ISOLATED GROUND PC PHOTO CELL N NEW FIXTURE LC LIGHTING CONTACTOR R RELOCATED FIXTURE MWC MINIMUM WORK CLEARANCE E INDICATES AN EXISTING OCP OVER CURRENT PROTECTION FIXTURE TO REMAIN OC ON CENTER TA TWIST LOCK WAREHOUSE CONSTRUCTION NOTE: ELECTRICAL CONTRACTOR SHALL INSTALL SUSPENDED LIGHT FD(TURE.S OR ANY CONDUIT GREATER THAN r IN DIAMETER DI WAREHOUSE AREAS MINIMUM 12' HM90NTAL FROM ANY 1ESFR' TYPE SPRINKLER HEAD. 1 J G F 7 �I J I i v�i 1 N, LB 33 R' I •` i NEW 3/4" EMT WITH PULL STRING TELEPHONE SERVICE RISER NOT TO SCALE HOLLISTER Co; 'C11A' TO REMAIN ;LUGGAGE AT SUNSET ELECTRICAL PLAN KEY NOTES: O CONNECT EXIT SIGNS AND EMERGENCY BATTERY LIGHTS TO NEAREST LIGHT AHEAD OF LIGHTING SWITCH AND MOTION SENSOR. O2 DISCONNECT EXISTING LIGHTS FROM TENANT 'C11A' PANELS AND ABANDOM. O3 RELOCATED THESE TWO LIGHT FIXTURE FROM ADJACENT ROOM. ® DISCONNECT ALL EXISTING CIRCUITS FROM TENANT 'C11A' PANELS CROSSING NEW WALL INTO NEW SPACE 'C11B', ABANDOM EXISTING RECEPTACLES AND OTHER ELECTRICAL DEVICES NOT SHOWN IN THIS PLAN. O 3 /4'EMT STUB 12" IN NEW SPACE FOR FUTURE TELEPHONE BOARD. © 2 0EMT STUB 12' IN NEW SPACE FOR FUTURE ELECTRICAL PANEL. =.e V --- - - - - -- t 4 1 p:0 LSE.: •t=;'iv4 :.r C. t 1 t UNTIL 11S9ITI iliii9gf R_1: i''�rS�wli IS,, ARE ISSUPP4 SCALIR 1/8" — 1 ' -0" A PFt 0'w E�"Di ILI), y I WARNING! MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAI REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS. CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. SPIN WATER C A14 f0 THE BEST OF MY KNOWLEDGE, THE PLANS AND SPECIFICATIONS SUBMITTED IEREWITH COMPLY WITH EXISTING INTERPRETATIONS AND PROVISIONS OF THE NPPLICABLE BUILDING CODES. THIS DRAWING IS THE SOLE PROPERTY OF HENZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISSIOI DF HENZ ENGINEERING INC. 1, THOMAS E. HENZ, P.E. #34261, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE ELECTRICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61G15- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHORIZATION„ #381t80 TO PROVIDE THE ENGINEERING SERVICE. ;'• i ,� COf1SULIIf1G E(1GIf im t: E c 2320 NE 9th Sheet, Suite 200 �( Fort Lauderdale, Florida 33304 FPSSIONMj_r;1G1NEER X61: T 954.523.4933 1 F�O ( F 954.523.5052 www.henz.com (, I DATE:I ' PROJECT No.: 11002.00 architect NORBERTO ROSENSTEIN ARCHITECT , INC. X0VECW - NrM DPI -RAW 126 S. FEDERAL HIGHWAY SURE f 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922-6551 FAX- (954) 922 -7388 WE$ wwwrosavdehlarchitseLcom STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COP1'RZGWT Q209 NOI®ERTO ROSENSTEAN ARCFIITECT, Dr— ALL Rr.*" RESERVED. T148 DOCUMENT OR PARTS TFERECP, MAY NOT OE REPRODUCED IN ANY FORM Un4C1UT PERhR66UX DESIGNED As DRAWN j AS.,, - a F,�•;r CHECKED t- ' TEH I HEREBY CERTIFY THAT THESE PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES. R E V I S 1 0 N S COMM. 2011 -12 DATE 1/4/2011 5701 SUNSET DR SUITES C11A AND C11B WHITE BOX. SOUTH MIAMI FLORIDA, 33143 ELECTRICAL PLAN E -1 2