Loading...
11-198-001PROJECT DIRECTORY ARCHITECT: NORBERTO ROSENSTEIN ARCHITECT, INC. 126 S. FEDERAL HWY DANIA BEACH, FL 33004 T. 954 - 922 -6551 F. 954 - 922 -7388 E. INFO@ROSENSTEINARCHITECT.COM MEP ENGINEER: FIRE STOPPING DETAILS HENZ ENGINEERING M -1 2320 NE 9th STREET, f,200 MECHANICAL PLAN FT. LAUDERDALE, FL 304 E -1 T. 954 - 523 -4933 ELECTRICAL PLAN F. 954 - 523 -5052 E -2 E. DAVID@HENZ.COM ELECTRICAL PLAN LANDLORD / CLIENT P -1 SIMON PLUMBING AND SANITARY PLAN TENANT COORDINATOR FP -1 DAVID FLETCHER FIRE PROTECTION PLAN 115 WASHINGTON STREET INDIANAPOLIS, INDIANA 46204 T. 317 263 2287 a�. S' .Jij`.q � Y . 'r s E. DFLETCHE @SIMON.COM ;$ : : �;a."�%�ae h ,4• �. -' fir, �h, �q : ' ��.f�h�,y '' ¢(�ro� J SYMBOL NOTES INDICATES DETAIL NUMBER INDICATES SHEET UPON WHICH DETAIL APPEARS ROOM NUMBER OR O DOOR NUMBER DETAIL REFERENCE E1 j( EQUIPMENT NUMBER �t�+, H %/1 ,: •k SS ., „�, • -&- - SECTION REFERENCE ' J( 6. ' •'' r �:':'i � ELEVATION Gi:L , r��"Y,b f3 ,%fb, I S:i 9 !' rl�"' -t �feS 41- /'':Sy7,y��,�r/ ELEVATION REFERENCE y ' , s' � s�i� gay ,�• ���Jy�,��,s',.��'yJ� � y..' • � ' "r J � %r TOILET ACC. REFERENCE 0- O COLUMN LINE NUMBER WALL TYPE REFERENCE 011 " (0A N r- FL White Box Sunset Mall RENOVATION 5701 SUNSET DRIVE, SOUTH MIAMI. FL PROJECT LOCATIO SHEE T INDEX A -1 BLDG DATA LOCATION PLAN A -2 DEMOLITION PLAN A -3 ARCHITECTURAL & REFLECTED CEILING PLAN A -4 FIRE STOPPING DETAILS M -1 MECHANICAL PLAN E -1 ELECTRICAL PLAN E -2 ELECTRICAL PLAN P -1 PLUMBING AND SANITARY PLAN FP -1 FIRE PROTECTION PLAN SITE MAP >: •� .� `°` r� i s J 3'`:. �1 i .; ,.� : / , ' ' ••-'/ ps iy, ' 1:: g • w.;Y . , ..; i.kv Mill .%a �' r6' S , % / /.j{rri :i �rT�y //'�,,, �S//.f�, yamg,si( $; .. : .S���''�lh?k' �' •" ' %J / /., i'. ` /� t ' ,. a�. S' .Jij`.q � Y . 'r s ,. , / -f ys•. �sx ,� 4 �: rr;y�" „thy; �''� Ar" ./, '.. ;$ : : �;a."�%�ae h ,4• �. -' fir, �h, �q : ' ��.f�h�,y '' ¢(�ro� J " �ry.•y�.�1 I f .. � -� a /fir Q:, ,� 4 � j� ;� , oa�,� 11 ilY i fifaj 'x <r. %;�:� %.. '% .% , '�a•�' Jo9 ' /•,.�,..i0 9 '/ri4y.rJ /,.'�. r "S��&, • ..: %r %J"5{�hR •'c'.',`f' �' �r /a�' 4�,,{;.ti 7�6Y%;�f 'n -"�'' 6Gf %ii.r,'f 6 ;, jig 2m5 •/' s. ,/, , -„ti � �..�6 � �t�+, H %/1 ,: •k SS ., „�, • $tm �'•% tab _ 8 � :' '�" gyy9c'r:Affl' C'.f�+ �r '� ' J( 6. ' •'' r �:':'i � /�f7:f,yy &� i % �. � .�.. ' %r• r.' /%� ; r,..... %G�' a rga-L" ;�.,L`�7� a p�r„�;n ,qy .sf ..�.ifH•' i/ / fk` .�.:� .G�, ! � ,q fW i " �y %Y� f���� f� v d��Jj; � � ,` �/� /� r ii/ 3 'A.f> "/S /:.�a %•"ij%ggaEE X37 s �1 � rye iY ia' 3 `• '..!a,- Jrc i/('J�` s Gi:L , r��"Y,b f3 ,%fb, I S:i 9 !' rl�"' -t �feS 41- /'':Sy7,y��,�r/ y ' , s' � s�i� gay ,�• ���Jy�,��,s',.��'yJ� � y..' • � ' "r J � %r Sr �,. ,%��`.�.f�. �;; 'S y " 6 '$w ° r�asr as J i;�f .1J %� y y� PROJECT LOCATIO N PLAN xe ' S 0 S.W. 57th Ave. (Red Rd.) s ON 1b] EA OF WORK PROJECT DESCRIPTION: SPACE REMODELING - NO CHANGE IN USE - NEW DEMISING WALL AUTHORITY. SOUTH MIAMI BUILDING DEPARTMENT 6130 SUNSET DRIVE SOUTH MIAMI, FL 33143 TEL: • 305 - 663 -6325 BUILDING CODE: 2007 FLORIDA BLDG. CODE AMENDMENTS: STATE AND LOCAL PLUMBING CODE: 2007 FLORIDA PLUMBING CODE MECHANICAL CODE: 2007 FLORIDA MECHANICAL CODE GAS CODE: 2007 FLORIDA FUEL GAS CODE ELECTRICAL CODE: 2008 NATIONAL ELECTRIC CODE FLORIDA FIRE PREVENTION CODE: 2007 CODE CONSTRUCTION TYPE: TYPE: 11 B USE: TYPE A MERCANTILE BUILDING IS SPRINKLERED NUMBER OF STORIES: TWO AREA OF CONSTRUCTION: 3,321 S.F. OCCUPANT LOAD PER TABLE 1003.1: C11 B 3,321/300 = 12 TOTAL (12 MAX.) * (SEE IDENTIFYING DEVICES, BELOW) EXITING WIDTH: 12 X 0.2 = 2.4" 2.4712" = .2 L.F. REQ'D. C11B 1 EXITS PROVIDED @ 2' -10 "= 2' -10" L.F. GENERAL NO TES DIVISION 1 GENERAL REQUIREMENTS 1. THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION OF THIS PROJECT, COMPLETE AND FUNCTIONAL IN ALL RESPECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO WORK NECESSARY AND REASONABLY INCIDENTAL FOR THE COMPLETE CONSTRUCTION OF THE PROJECT SHALL NOT BE CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS RESPONSIBILITIES. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. FAILURE TO DO SO CONSTITUTES ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. THE CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME OR MONEY REQUIRED TO RECTIFY THE SITUATION. 3. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE DRAWINGS. 4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PURCHASED, FABRICATED AND FINISHED ITEMS FOR REVIEW BY THE ARCHITECT UNLESS WAIVED BY THE SAME. 5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED INTO THE PROJECT SHALL BE NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB CONSTRUCTION INCLUDING A SAFE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT TO THE WORK AREA. 8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS NECESSARY FOR PROPER COMPLETION OF WORK, UNLESS NOTED OTHERWISE. 9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT REQUESTING CLARIFICATION. THE CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE BY THE CONTRACTOR WITHOUT PRIOR CLARIFICATION BY THE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE. 10. ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES. 11. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE CONTRACTOR ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A WATERTIGHT, WEATHER TIGHT PROJECT. 12. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT OVER BEAM OR COLUMN UNLESS DIRECTED OTHERWISE BY OWNER. 13. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES (WOOD TO BE FIRE RETARDANT). 14. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND APPROVAL UNDER SEPERATE PERMIT BY OWNER /CONTRACTOR. 15. ALL ANGLES AT 45"" OR 90^ UNO. DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO ALLOW FOR ALL PROPOSED NEW WORK. 2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT AREAS WHERE DEMOLITION HAS BEEN REQUIRED. 3. PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES PRIOR TO DEMOLITION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. 5. THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO START OF WORK, THE REQUIREMENTS FOR CORING OF FLOOR SLAB FOR ALL REQUIRED WORK. 6. THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER SUBSTANCES. 8. COMPLY WITH APPLICABLE CODES AND /OR ORDINANCES CONCERNING DEMOLITION OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. DIVISION 3 CONCRETE 1. VICLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT FLOOR COVERING. DIVISION 5 METALS 1. STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LINTELS, CLIP ANGELS, SHOES, REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATIONS INDICATED. 2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3 -1/2 INCH x 25 GAGE MIN. (20 GAGE FOR STUDS OVER 14' -0" IN HEIGHT AND AT WALL AT WATER HEATER /MOP SINK ENCLOSURE). DIVISION 8 DOORS & WINDOWS 1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARDS SET FORTH IN THE UNIFORM BUILDING CODE. 2. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. 3. MANUALLY OPERATED EDGE OR SUK- IOUNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY OTHER? I „ _ OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR ARE PROHIBITED. WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOORKNOB OR SURFACE - MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE UNIFORM BUILDING CODE. THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 TO 44 INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. DIVISION 9 FINISHES 1. INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND MAXIMUM SMOKE DEVELOPMENT RATING OF 450. 2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL LOAD OF 5 PSF AS FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB FLOOR WITH 300# POWER DRIVEN PINS AT 48" O.C. ICBO #1639 3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE LIGHT ORANGE PEEL FINISH, UNLESS NOTED OTHERWISE, 4. THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE CAULKING WHERE NECESSARY. DIVISION 10 SPECIALTIES - 1. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / MODIFICATION TO THE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT SHOP DRAWING TO GOVERNING AUTHORITY FOR REVIEW W/ PERMIT SET. DIVISION 12 FURNISHINGS 1. ALL MILLWORK TO BE CUSTOM GRADE AS CHOSEN BY OWNER. PROVIDE CASEWORK WITH ALL NECESSARY HARDWARE HINGES AND PULLS. EXISTING PORTION3 dF GU;LI PIGS SHALL CO.iPLY WITH THE PROVISIONS OF EXI'il• l",,O OC(;t;i',�•i,= �1�:i, AS SET FORTH I14 TKE FLORIDA FIR' P:,EV21;:'110M (;Ou -_ F.0 0CC,,p ;a. 1.Cy rEP?,flTTED UNTIL. ADDITIONAL LIFE SAFE i i PERNIITS ARE ISSUE - M IAM,I -DARE r, �01�,,i- i'QK O SpK WA it'd No] i� eCrl�NaON i nA-m G% )1 I y d 0 WNER' S REVIEW OF THESE CONSTRUCTION DOCUMENTS CITY OF SOUTH MIAMI.' THE CONSTRUCTION CONTRACT FOR THIS PROJECT IS TO BE NEGOTIATED DIRECTLY BETWEEN BUILDING DEPT. THE OWNER AND THE CONTRACTOR, AND THEY WILL ACT IN UNISON TO PROPERLY EXECUTE sTI %C; unL sccTloN THE INTENT OF THESE AND OTHER DESIGN AND CONTRACT DOCUMENTS. THIS SET OF DOCUMENTS (SHEETS A -1 THROUGH A -4) COVERS GENERAL DEMOLITION ITEMS AND EXCLUDES ANY DESIGN OF SITE, OR FIRE PROTECTION WORK. ALSO EXCLUDED ARE ANY EQUIPMENT ITEMS. ta;,1T: ALL THESE EXCLUSIONS ARE COVERED UNDER SEPARATE DESIGN """"•' �` WORK BY DESIGNERS WORKING DIRECTLY FOR THE CONTRACTOR AND /OR THE OWNERS CLIENT. BY USE OF THESE DOCUMENTS, THE OWNER AND THE CONTRACTOR CERTIFY THAT THEY HAVE REVIEWED THEM AND ARE IN AGREEMENT WITH THEIR CONTENT; ALSO THAT IF ANY CHANGES ARE REQUIRED THEY WILL BE DONE IN ACCORDANCE WITH ALL APPLICABLE CODES AND UNDER THE CONTRACTOR'S OR OWNER'S SUPERVISION. THE CONTRACTOR ASSUMES RESPONSIBILITY FOR COORDINATING THE VARIOUS OTHER CONSTRUCTION DOCUMENTS WITH THESE DESIGN DOCUMENTS TO ASSURE CODE COMPLIANCE AND CORRECTNESS OF WORK. THE CONTRACTOR AND OR OWNERS ASSIGNED AGENT IS ALSO RESPONSIBLE FOR OBTAINING FINAL COMMENTS AND APPROVAL FROM ALL GOVERNING AGENCIES. ANY AS BUILT OR CHANGES TO THE DOCUMENTS AFTER THE JOB IS PERMITTED ARE ON THE COD BASIS AND IS TO BE PAID IN FULL TO THE APPROPRIATE PARTY. "APPROPRIATE PARTY" PER APPROVED CHANGE ORDER[S] BY CLIENT. architect NORBERTO ROSENSTEIN ARCHITECT , INC. M0UECM - NTEWR DESItlV - P .WW 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL- infoorosensteinarchitectcom WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2006 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOTT.H�R�ODUCED IN ANY FORM WITHO PEUT RMISSIORt., DESIGNED 1Ci� ••• ��'� N.R. QQ '•,:y1��i� �, •�• � %'! DRAWN C,\ I r` J. G. CHECKED N.R. I HEREBY CERTIFY THAY''THESE"PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES, R E V I S 1 0 N S COMM. DATE 2011 -12 2/14/2011 5701 SUNSET DR SUITES C11 B WHITE BOX SOUTH MIAMI FLORIDA, 33143 LOCATION PLAN BUILDING DATA A-1 °F 4 •• - • 0 0 0 - - - - s---ti - N PLAN xe ' S 0 S.W. 57th Ave. (Red Rd.) s ON 1b] EA OF WORK PROJECT DESCRIPTION: SPACE REMODELING - NO CHANGE IN USE - NEW DEMISING WALL AUTHORITY. SOUTH MIAMI BUILDING DEPARTMENT 6130 SUNSET DRIVE SOUTH MIAMI, FL 33143 TEL: • 305 - 663 -6325 BUILDING CODE: 2007 FLORIDA BLDG. CODE AMENDMENTS: STATE AND LOCAL PLUMBING CODE: 2007 FLORIDA PLUMBING CODE MECHANICAL CODE: 2007 FLORIDA MECHANICAL CODE GAS CODE: 2007 FLORIDA FUEL GAS CODE ELECTRICAL CODE: 2008 NATIONAL ELECTRIC CODE FLORIDA FIRE PREVENTION CODE: 2007 CODE CONSTRUCTION TYPE: TYPE: 11 B USE: TYPE A MERCANTILE BUILDING IS SPRINKLERED NUMBER OF STORIES: TWO AREA OF CONSTRUCTION: 3,321 S.F. OCCUPANT LOAD PER TABLE 1003.1: C11 B 3,321/300 = 12 TOTAL (12 MAX.) * (SEE IDENTIFYING DEVICES, BELOW) EXITING WIDTH: 12 X 0.2 = 2.4" 2.4712" = .2 L.F. REQ'D. C11B 1 EXITS PROVIDED @ 2' -10 "= 2' -10" L.F. GENERAL NO TES DIVISION 1 GENERAL REQUIREMENTS 1. THE INTENT OF THESE DOCUMENTS IS TO PROVIDE FOR THE CONSTRUCTION OF THIS PROJECT, COMPLETE AND FUNCTIONAL IN ALL RESPECTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THIS RESULT. THE OMISSION OF EXPRESS REFERENCE TO WORK NECESSARY AND REASONABLY INCIDENTAL FOR THE COMPLETE CONSTRUCTION OF THE PROJECT SHALL NOT BE CONSTRUED AS RELEASING THE CONTRACTOR FROM HIS RESPONSIBILITIES. 2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, CLEARANCES AND CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. FAILURE TO DO SO CONSTITUTES ACCEPTANCE AND RESPONSIBILITY FOR ALL EXISTING CONDITIONS. THE CONTRACTOR WILL NOT BE ALLOWED ADJUSTMENTS IN THE TIME OR MONEY REQUIRED TO RECTIFY THE SITUATION. 3. DO NOT SCALE DRAWINGS. GIVEN DIMENSIONS SHALL GOVERN. LARGE SCALE DRAWINGS SHALL GOVERN OVER SMALL SCALE DRAWINGS. 4. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF ALL PURCHASED, FABRICATED AND FINISHED ITEMS FOR REVIEW BY THE ARCHITECT UNLESS WAIVED BY THE SAME. 5. ALL EQUIPMENT, MATERIALS AND ARTICLES INCORPORATED INTO THE PROJECT SHALL BE NEW AND UNDAMAGED. ALL WORKMANSHIP SHALL BE WITHIN INDUSTRY STANDARDS. 6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIR AND REPLACEMENT OF DAMAGE TO AREAS CAUSED BY HIS WORK AT NO ADDITIONAL COST TO THE OWNER. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY CONDITIONS RELATING TO JOB CONSTRUCTION INCLUDING A SAFE ENVIRONMENT FOR OCCUPANTS OF AREAS ADJACENT TO THE WORK AREA. 8. THE CONTRACTOR SHALL PAY ALL FEES FOR PERMITS NECESSARY FOR PROPER COMPLETION OF WORK, UNLESS NOTED OTHERWISE. 9. SHOULD THE CONTRACTOR OBSERVE ERRORS, DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENTS, HE SHALL PROMPTLY NOTIFY THE ARCHITECT REQUESTING CLARIFICATION. THE CONTRACTOR SHALL NOT PROCEED WITH WORK AFFECTED BY SUCH ERRORS, DISCREPANCIES OR OMISSIONS WITHOUT RECEIVING CLARIFICATIONS. ADJUSTMENTS INVOLVING SUCH CONDITIONS MADE BY THE CONTRACTOR WITHOUT PRIOR CLARIFICATION BY THE ARCHITECT, SHALL BE AT THE CONTRACTOR'S OWN RISK. COMPLICATIONS ARISING FROM PROCEEDING WITHOUT CLARIFICATION SHALL BE RESOLVED AT THE CONTRACTOR'S EXPENSE. 10. ALL WORK PERFORMED ON THIS PROJECT SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL CODES, LAWS AND ORDINANCES. 11. ANYTHING IN THE CONTRACT DOCUMENTS NOT WITHSTANDING, THE CONTRACTOR ACCEPTS THE RESPONSIBILITY OF CONSTRUCTING A WATERTIGHT, WEATHER TIGHT PROJECT. 12. CONTRACTOR SHALL COORDINATE LOCATION OF ALL NEW ROOF MOUNTED EQUIPMENT WITH OWNER PRIOR TO INSTALL. CENTER EQUIPMENT OVER BEAM OR COLUMN UNLESS DIRECTED OTHERWISE BY OWNER. 13. CONTRACTOR SHALL PROVIDE 2x BLOCKING AT ALL WALL MOUNTED EQUIPMENT OR ACCESSORIES (WOOD TO BE FIRE RETARDANT). 14. ALL SIGNS, INCLUDING WINDOW SIGNS, TO BE SUBMITTED FOR REVIEW AND APPROVAL UNDER SEPERATE PERMIT BY OWNER /CONTRACTOR. 15. ALL ANGLES AT 45"" OR 90^ UNO. DIVISION 2 DEMOLITION; HAZARDOUS MATERIALS 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DEMOLITION REQUIRED TO ALLOW FOR ALL PROPOSED NEW WORK. 2. PATCH, REPAIR, REPLACE AND FINISH ANY FLOOR, WALL OR CEILING TO MATCH ADJACENT AREAS WHERE DEMOLITION HAS BEEN REQUIRED. 3. PROVIDE PROPER SHORING AND DISCONNECTION OF ALL UTILITIES PRIOR TO DEMOLITION. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING THE SITE FREE OF DEBRIS. 5. THE CONTRACTOR SHALL COORDINATE WITH BUILDING OWNER PRIOR TO START OF WORK, THE REQUIREMENTS FOR CORING OF FLOOR SLAB FOR ALL REQUIRED WORK. 6. THE ARCHITECT AND ENGINEERS, AND CONSULTANTS SHALL HAVE NO RESPONSIBILITY FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER TOXIC SUBSTANCES. 7. THE CONTRACTOR SHALL BE FULLY RESPONSIBLE FOR THE DISCOVERY, PRESENCE, HANDLING, REMOVAL OR DISPOSAL OF OR EXPOSURE OF PERSONS TO HAZARDOUS MATERIALS IN ANY FORM AT THE PROJECT SITE, INCLUDING BUT NOT LIMITED TO ASBESTOS, ASBESTOS PRODUCTS, POLYCHLORINATED BIPHENYL (PCB) OR OTHER SUBSTANCES. 8. COMPLY WITH APPLICABLE CODES AND /OR ORDINANCES CONCERNING DEMOLITION OPERATIONS, REFUSE REMOVAL, AND DISPOSAL. DIVISION 3 CONCRETE 1. VICLEAN, GRIND AND FILL EXISTING CONCRETE TO ACCEPT FLOOR COVERING. DIVISION 5 METALS 1. STEEL FRAMING: WITH EACH TYPE OF METAL FRAMING REQUIRED, PROVIDE MANUFACTURER'S STANDARD STEEL RUNNER, BLOCKING, LINTELS, CLIP ANGELS, SHOES, REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY THE MANUFACTURER FOR THE APPLICATIONS INDICATED. 2. METAL STUDS: OPEN BOX SHAPED SECTIONS, 3 -1/2 INCH x 25 GAGE MIN. (20 GAGE FOR STUDS OVER 14' -0" IN HEIGHT AND AT WALL AT WATER HEATER /MOP SINK ENCLOSURE). DIVISION 8 DOORS & WINDOWS 1. ALL GLASS SUBJECT TO HUMAN IMPACT SHALL CONFORM TO THE STANDARDS SET FORTH IN THE UNIFORM BUILDING CODE. 2. ALL EXITS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. 3. MANUALLY OPERATED EDGE OR SUK- IOUNTED FLUSH BOLTS AND SURFACE BOLTS OR ANY OTHER? I „ _ OF DEVICE THAT MAY BE USED TO CLOSE OR RESTRAIN THE DOOR ARE PROHIBITED. WHERE EXIT DOORS ARE USED IN PAIRS AND APPROVED AUTOMATIC FLUSH BOLTS ARE USED, THE DOOR LEAF HAVING THE AUTOMATIC FLUSH BOLTS SHALL HAVE NO DOORKNOB OR SURFACE - MOUNTED HARDWARE. THE UNLATCHING OF ANY LEAF SHALL NOT REQUIRE MORE THAN ONE OPERATION. 4. PANIC HARDWARE, WHERE INSTALLED, SHALL COMPLY WITH THE UNIFORM BUILDING CODE. THE ACTIVATING MEMBER SHALL BE MOUNTED AT 36 TO 44 INCHES ABOVE THE FLOOR. THE UNLATCHING FORCE SHALL NOT EXCEED 15 POUNDS WHEN APPLIED IN THE DIRECTION OF TRAVEL. DIVISION 9 FINISHES 1. INTERIOR FINISHES TO HAVE A MAXIMUM FLAME SPREAD RATING OF 200 AND MAXIMUM SMOKE DEVELOPMENT RATING OF 450. 2. STUD PARTITIONS TO BE ANCHORED SO AS TO RESIST A LATERAL LOAD OF 5 PSF AS FOLLOWS, BOTTOM PLATE: ANCHOR TO SUB FLOOR WITH 300# POWER DRIVEN PINS AT 48" O.C. ICBO #1639 3. GYP BOARD WALLS TO BE TAPED, SANDED AND HAVE LIGHT ORANGE PEEL FINISH, UNLESS NOTED OTHERWISE, 4. THE CONTRACTOR SHALL PROVIDE AND INSTALL FIRE CAULKING WHERE NECESSARY. DIVISION 10 SPECIALTIES - 1. CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND INSTALLATION / MODIFICATION TO THE FIRE SPRINKLER SYSTEM. CONTRACTOR SHALL SUBMIT SHOP DRAWING TO GOVERNING AUTHORITY FOR REVIEW W/ PERMIT SET. DIVISION 12 FURNISHINGS 1. ALL MILLWORK TO BE CUSTOM GRADE AS CHOSEN BY OWNER. PROVIDE CASEWORK WITH ALL NECESSARY HARDWARE HINGES AND PULLS. EXISTING PORTION3 dF GU;LI PIGS SHALL CO.iPLY WITH THE PROVISIONS OF EXI'il• l",,O OC(;t;i',�•i,= �1�:i, AS SET FORTH I14 TKE FLORIDA FIR' P:,EV21;:'110M (;Ou -_ F.0 0CC,,p ;a. 1.Cy rEP?,flTTED UNTIL. ADDITIONAL LIFE SAFE i i PERNIITS ARE ISSUE - M IAM,I -DARE r, �01�,,i- i'QK O SpK WA it'd No] i� eCrl�NaON i nA-m G% )1 I y d 0 WNER' S REVIEW OF THESE CONSTRUCTION DOCUMENTS CITY OF SOUTH MIAMI.' THE CONSTRUCTION CONTRACT FOR THIS PROJECT IS TO BE NEGOTIATED DIRECTLY BETWEEN BUILDING DEPT. THE OWNER AND THE CONTRACTOR, AND THEY WILL ACT IN UNISON TO PROPERLY EXECUTE sTI %C; unL sccTloN THE INTENT OF THESE AND OTHER DESIGN AND CONTRACT DOCUMENTS. THIS SET OF DOCUMENTS (SHEETS A -1 THROUGH A -4) COVERS GENERAL DEMOLITION ITEMS AND EXCLUDES ANY DESIGN OF SITE, OR FIRE PROTECTION WORK. ALSO EXCLUDED ARE ANY EQUIPMENT ITEMS. ta;,1T: ALL THESE EXCLUSIONS ARE COVERED UNDER SEPARATE DESIGN """"•' �` WORK BY DESIGNERS WORKING DIRECTLY FOR THE CONTRACTOR AND /OR THE OWNERS CLIENT. BY USE OF THESE DOCUMENTS, THE OWNER AND THE CONTRACTOR CERTIFY THAT THEY HAVE REVIEWED THEM AND ARE IN AGREEMENT WITH THEIR CONTENT; ALSO THAT IF ANY CHANGES ARE REQUIRED THEY WILL BE DONE IN ACCORDANCE WITH ALL APPLICABLE CODES AND UNDER THE CONTRACTOR'S OR OWNER'S SUPERVISION. THE CONTRACTOR ASSUMES RESPONSIBILITY FOR COORDINATING THE VARIOUS OTHER CONSTRUCTION DOCUMENTS WITH THESE DESIGN DOCUMENTS TO ASSURE CODE COMPLIANCE AND CORRECTNESS OF WORK. THE CONTRACTOR AND OR OWNERS ASSIGNED AGENT IS ALSO RESPONSIBLE FOR OBTAINING FINAL COMMENTS AND APPROVAL FROM ALL GOVERNING AGENCIES. ANY AS BUILT OR CHANGES TO THE DOCUMENTS AFTER THE JOB IS PERMITTED ARE ON THE COD BASIS AND IS TO BE PAID IN FULL TO THE APPROPRIATE PARTY. "APPROPRIATE PARTY" PER APPROVED CHANGE ORDER[S] BY CLIENT. architect NORBERTO ROSENSTEIN ARCHITECT , INC. M0UECM - NTEWR DESItlV - P .WW 126 S. FEDERAL HIGHWAY SUITE # 202 DANIA BEACH, FLORIDA 33004 PH: (954) 922 -6551 FAX: (954) 922 -7388 EMAIL- infoorosensteinarchitectcom WEB: www.rosensteinarchitect.com STATE REG. NO. AR0016674 NATL. REG. NO. 69178 COPYRIGHT © 2006 NORBERTO ROSENSTEIN ARCHITECT, INC. ALL RIGHTS RESERVED. THIS DOCUMENT OR PARTS THEREOF, MAY NOTT.H�R�ODUCED IN ANY FORM WITHO PEUT RMISSIORt., DESIGNED 1Ci� ••• ��'� N.R. QQ '•,:y1��i� �, •�• � %'! DRAWN C,\ I r` J. G. CHECKED N.R. I HEREBY CERTIFY THAY''THESE"PLANS WHERE PREPARED BY ME OR UNDER MY SUPERVISION, AND TO THE BEST OF MY KNOWLEDGE, COMPLY WITH ALL APPLICABLE CODES, R E V I S 1 0 N S COMM. DATE 2011 -12 2/14/2011 5701 SUNSET DR SUITES C11 B WHITE BOX SOUTH MIAMI FLORIDA, 33143 LOCATION PLAN BUILDING DATA A-1 °F 4