11-05-003
a CY Cr 0 Er C' a i D c ELECTRICAL SPECIFICATIONS 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH THE ADOPTED EDITION OF THE NATIONAL ELECTRIC CODE, N.F.P.A., LOCAL CODES, ORDINANCES, INCLUDING ALL AMENDMENTS TO THE N.E.C. EQUIPMENT, WHERE APPLICABLE, WILL BE LISTED WITH THE UNDERWRITERS LABORATORIES, INC. QUALITY AND WORKMANSHIP ESTABLISHED BY DRAWINGS AND SPECIFICATIONS ARE NOT TO BE REDUCED BY THE ABOVE MENTIONED CODES. 2. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD AN EXAMINATION BEEN MADE, WILL NOT BE AVOWED. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST -CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND ACCEPTANCE OF THIS SYSTEM BY THE ENGINEER MUST BE A CONDITION OF THE SUB CONTRACT. 4. ALL WORK TO BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. 6. CORRECTION OF ANY DEFECTS TO BE COMPLETED WITHOUT ADDITIONAL CHARGE AND TO INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 7. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 8. CONTRACTOR TO PAY FOR ALL PERMITS, FEES INSPECTIONS AND TESTINGS. 9. ELECTRICAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND TELEPHONE COMPANIES. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL POWER AND TELEPHONE COMPANIES PRIOR TO START OF CONSTRUCTION. 10. AH WIRING SHALL BE IN CONDUIT UNLESS OTHERWISE NOTED, MINIMUM WIRE SIZE SHALL BE #12 AWG, EXCLUDING CONTROL WIRING. ALL CONDUCTORS SHALL BE COPPER WITH THWN/THHN INSULATION. CONDUCTORS #10 AND SMALLER MAY BE SOLID; ALL THOSE #8 AND LARGER TO BE STRANDED. 11. AV UNDERGROUND RACEWAYS SHAH BE MINIMUM 3/4 ", GALVANIZED RIGID STEEL CONDUIT OR SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY WITH GOVERNING CODES. WHERE RIGID STEEL IS USED, IT SHAH BE COMPLETELY COATED WITH AN ALKALI AND RUST RESISTANT BITUMASTiC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. RIGID STEEL SHALL ALSO BE USED WHEN CONDUIT IS EXPOSED TO EXTERIOR ENVIRONMENT SUCH AS EXTERIOR OF BUILDING OR WHERE IT IS EXPOSED AND SUBJECT TO DAMAGE, INSIDE OF BUILDING. 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS IN WET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER CLASSIFIED AREAS. AH BOXES SHALL BE RECESSED (FLUSH) IN WALLS OR CEILINGS WHENEVER POSSIBLE. 13. DISCONNECT SWITCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK -MAKE, QUICK -BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.C. AND LOCATION (WEATHERPROOF, EXPLOSION PROOF, ETC.). ENGRAVED LAMINATED PLASTIC IDENTIFICATION PLATES SHAH BE FURNISHED AND INSTALLED ON ALL DISCONNECT SWITCHES, CONTACTORS AND STARTERS. 14. ALL FUSES FOR SAFETY SWITCHES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE. FUSES SHALL BE THOSE MANUFACTURED BY EITHER BUSSMAN OR UTTLEFUSE. THE CONTRACTOR SHAH FURNISH TO THE OWNER ONE SPARE FUSE FOR EACH SIZE AND TYPE OF FUSE INSTALLED. FUSES 600 AMPS OR LESS SHALL BE CLASS RK1, TYPICAL UNLESS OTHERWISE NOTED. FUSES OVER 600 AMPS SHALL BE CLASS L 15. ALL GENERAL PURPOSE SWITCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER. CATALOG NUMBERS LISTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES BY PASS & SEYMOUR, BRYANT, OR ARROW HART WILL BE ACCEPTED. COLOR OF DEVICES AND PLATES SHALL BE WHITE UNLESS DICTATED OTHERWISE BY ARCHITECT /OWNER. A. SWITCHES: LEVITON #CSB1 -20W B. RECEPTACLES: LEVITON #BR20 -W C. COVER PLATES: SMOOTH PLASTIC NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. 16. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT BE PLACED IN PROPER WORKING ORDER. 17. A SEPARATE, GREEN TYPE THAN COPPER GROUND CONDUCTOR SHAH BE RUN FROM GROUND LUG OF EACH GROUNDED RECEPTACLE TO AN APPROVED CONNECTION INSIDE THE ENCLOSING STEEL OUTLET BOX. DEVICE MOUNTING SCREWS SHALL NOT BE CONSIDERED AN APPROVED GROUND. A SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT AND RACEWAY AND SECURELY BONDED IN AN APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RUN. THE GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH TABLE 250 -122 OF THE N.E.C. CONTRACTOR SHAH SIZE CONDUIT TO ACCOMMODATE ADDITIONAL CONDUCTOR. 18. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TIME OF DESIGN. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. 19. CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR IS TO PROVIDE CIRCUITS AND ROUTING OF CONDUITS TO SUIT JOB CONDITIONS. 20. FURNISH AND INSTALL DISCONNECT SWITCHES, WIRING, AND CONNECTIONS ON AIR CONDITIONING SYSTEM AS SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND WIRING FROM C.U.TO A.H.U. ,TERMINA11ON SHALL BE PERFORMED BY MECHANICAL CONTRACTOR. 21. ALL FLUORESCENT LIGHT FIXTURES SHAH HAVE IN LINE FUSING AND ENERGY SAVING BALLASTS. (ONLY REQUIRED IN MIAMI DADE COUNTY) 22. ALL SWITCHGEAR, PANELS, STARTERS, CONTACTORS ETC., SHALL BE THE PRODUCT OF A SINGLE MANUFACTURER, THE SYSTEM DESIGN IS BASED ON SQUARE "D "; HOWEVER, COMPARABLE EQUIPMENT BY G.E. & SIEMENS ONLY WILL BE ACCEPTABLE. TANDEM AND HALF -SPACE CIRCUIT BREAKERS SHALL NOT BE USED. 23. PROVIDE IDENTIFICATION FOR ALL PANELS, CABINETS, ENCLOSURES, DISCONNECTS & TRANSFORMERS USING ENGRAVED NAMEPLATES, WHITE LETTERING ON A BLACK BACKGROUND. NAMEPLATES SHALL IDENTIFY PANEL DESIGNATION (NAME,) VOLTAGE, PHASE & WIRE CONFIGURATION. PROVIDE TYPEWRITTEN DIRECTORIES UNDER PLASTIC COVER FOR ALL PANEL BRANCH CIRCUITS, CLEARLY INDICATING AREA AND TYPE OF LOAD SERVED BY EACH BRANCH CKT PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED WILL NOT 24. ENEGRA��VED, LAMINATED PLASTIC IDENTIFICATION PLATES SHAH BE FURNISHED AND INSTALLED ON AH PANELS AND SWITCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, INDICATING PANEL NAME, VOLTAGE AND AMPERAGE. 25. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RIGID STEEL ELBOWS AND RIGID STEEL SECTIONS AT SLAB PENETRATIONS WHERE SUBJECT TO POSSIBLE DAMAGE. WHERE RIGID STEEL IS USED, IT SHAH BE COMPLETELY COATED WITH AN ALKALI AND RUST - RESISTANT BITUMASTIC PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. 26. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WITH THE LOCAL POWER COMPANY AT THE SITE PRIOR TO CONSTRUCTION. AT THAT TIME, THE CONTRACTOR SHAH COORDINATE ALL RELATED WORK WITH THE U11UTY COMPANY'S RESPONSIBILITIES TO MEET THE OWNER'S SCHED. 27. AV ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, IMC, RIGID GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. THERE SHALL BE NO TYPE 'NM', ELECTRICAL NON- METALLIC TUBING, & FLEXIBLE METAL CONDUIT USED FOR BRANCH CIRCUITING. MAXIMUM NUMBER OF 120V CIRCUITS ALLOWED IN A COMMON CONDUIT SHALL BE SIX (6). "MC" TYPE CABLE SHAH NOT BE USED AS HOME RUNS. THE CONTRACTOR SHAH STRICTLY CONFORM TO THE N.E.C. REQUIREMENTS OF DERATING FOR CONDUCTOR AMPACITY AND CONDUIT FILL 28. CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: 208V SYSTEM 480V SYSTEM PHASE SEQUENCE NEUTRAL -WHITE NEUTRAL - WHITE /STRIPE ABC, TOP TO BOTTOM PHASE A - BLACK PHASE A - BROWN LEFT TO RIGHT, FRONT PHASE B - RED PHASE B - PURPLE TO BACK PHASE C - BLUE PHASE C - YELLOW GRD.CON - GREEN GRD.CON - GREEN 29. CONTRACTOR SHAH BE RESPONSIBLE FOR SEALING ALL CONDUIT PENETRATIONS MADE THROUGH FIRE RATED WALLS, CEILINGS, SLABS, ETC. PENETRATION SEALS SHALL BE PER U.L ASSEMBLY STANDARDS. 30. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DRAWINGS AT JOB SITE WITH COLORED MARKINGS INDICATING PROGRESS OF WORK. THIS SET OF CONTRACT DRAWINGS IS TO BE SEPARATE FROM AND IN ADDITION TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF EQUIPMENT, DEVICE, CONDUIT AND WIRE IS TO MARKED WHEN INSTALLED. USE GREEN TO INDICATE INSTALLATION AS SHOWN ON DRAWINGS AND USE ED TO INDICATE FIELD CHANGES. UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, AND BECOME PROPERTY OF THE ELECTRICAL ENGINEER. 31. IF ELECTRICAL CONTRACTOR HAS QUESTIONS, OR IN THEIR OPINION FINDS OMISSIONS OR ERRORS ON ELECTRICAL DOCUMENTS, IT IS THEI R RESPONSIBILITY TO BRING THIS TO THE ATTENTION OF THE ELECTRICAL ENGINEER IMMEDIATELY. IF ELECTRICAL CONTRACTOR PROCEEDS WITH ANY CHANGES TO THE CONTRACT DOCUMENTS, WITHOUT WRITTEN PRIOR APPROVAL FROM THE ELECTRICAL ENGINEER, CONTRACTOR WILL NOT BE COMPENSATED. DATA ROOM EXISTING 3 - #4, 1 - #8 GND, AWG THWN CU IN 1 "EMT EXISTING UPS 12KVA PROVIDE 45 MINUTES MIN. OF BATTERY BACK -UP @ 100% OF RATING 208Y/12OV -10,3W NEMA 1 NEW 4 -#1/0, 1-#1/0 GND, AWG FTT- EXISTING 4 - #3/0, 1 - #1/0 GND, THWN CU IN 2 "EMT I I I AWG THWN CU IN 2 "EMT II I I I I I I I I I NEW PANEL WITH SYMBOL DESCRIPTION p,�ptE7, 1 - #1/0 GND, AWG LOADCENTERS - Q0 `' THWN CU IN 2 "C PANELBOARD - NQOD VLO 277/480 PANELBOARD - NF "E" ^' EXISTING (PNLS SHALL BE MTD 0 +60" A.F.F, U.N.D) METER MLO M 5' -0" TO 6' -0" A.F.G. FEED THRU BUS 400 AMP FUSED DISCONNECT D73C, A 5' -0" TO 6' -0" A.F.G. PANEL MAIN CIRCUIT BREAKER 120V/208Y ® DISCONNECT 'LA' 5' -0" TO 6' -0" A.F.G. 3 PHASE LC m 0000 ®o ®�� EXISTING bPB BUILT -IN 150A 3P 5' -0" TO 6' -0" A.F.G. 200A I I' GROUND SYSTEM MCB MCB TRANSIENT VOLTAGE SURGE SUPPRESSOR LIGHTING CONTACTOR INTERMATIC SEE PNL SCHEDULE FOR MDL. - CIRCUIT BREAKER LIGHTING CONTACTOR (MECHANICAL LATCH) `J TIME- SWITCH BY INTERMATIC NEMA 1 MDL#ET70815CR. EXISTING TO REMAIN I I BOLD LINES DENOTE NEW WORK OR EQUIPMENT vEa+mn,ce TRANSFORMER aHnx�aa;r' I Ham., TYPICAL. 480 A 277 V TO 208Y7270 v 800A DRY TYPE NEMA 1 NEW EXISTING EXISTING EXISTING EXISTING MCB PANEL PANEL PANEL PANEL PANEL ° I 'LF' 'H A' 'LC' 'LD' 'LE' LC ITC] 225A 225A r� I ° 225A MLO 225A 225A MLO CONNECT TO 2ND MLO MLO MLO FLOOR ZONE I ° CONTROL ZONE IN 480Y/277V EXISTING LIGHTING NEMA 1 NEMA 1 RELAY PANEL I � NEMA 1 NEMA 1 NEMA 1 I I 208Y/120V 3P,4W RISER DIAGRAM LEGEND SYMBOL DESCRIPTION p,�ptE7, 1 - #1/0 GND, AWG LOADCENTERS - Q0 `' THWN CU IN 2 "C PANELBOARD - NQOD VLO 277/480 PANELBOARD - NF "E" ^' EXISTING (PNLS SHALL BE MTD 0 +60" A.F.F, U.N.D) METER MLO M 5' -0" TO 6' -0" A.F.G. FEED THRU BUS 400 AMP FUSED DISCONNECT D73C, A 5' -0" TO 6' -0" A.F.G. PANEL MAIN CIRCUIT BREAKER 120V/208Y ® DISCONNECT 'LA' 5' -0" TO 6' -0" A.F.G. 3 PHASE LC TRANSFER SWITCH 5' -0" TO 6' -0" A.F.G. 200A I I' GROUND SYSTEM MCB MCB TRANSIENT VOLTAGE SURGE SUPPRESSOR INTERMATIC SEE PNL SCHEDULE FOR MDL. - CIRCUIT BREAKER LIGHTING CONTACTOR (MECHANICAL LATCH) `J TIME- SWITCH BY INTERMATIC NEMA 1 MDL#ET70815CR. EXISTING TO REMAIN BOLD LINES DENOTE NEW WORK OR EQUIPMENT vEa+mn,ce TRANSFORMER aHnx�aa;r' I Ham., TYPICAL. 480 A 277 V TO 208Y7270 v DRY TYPE TRANSF. PROVIDE NEW - 150A -3P CIRCUIT BREAKER EXISTING 4 -#4/0, EXISTING 4 - #3/0, 1-#1/0 GND, AWG 1 - #1/0 GND, AWG THWN CU IN 2 1 /2 °C THWN CU IN 2 "C EXISTING EXISTING EXISTING 400 AMP PANEL PANEL 120V/208Y 'LB' 'LA' 3 PHASE LC 225A 200A 3400A 400A MCB MCB EXISTING NEMA 1 NEMA 1 VENTILATED NEMA 1 150 KVA TRANSFORMER 480 A V TO 208Y/120 V DRY TYPE NEMA 1 EXISTING ,, GND. TO " POSE BUILDING EXISTING 2 SETS OF 4-#500 0 AWG THWN CU IN 4"EMT EACH SET r� r EXISTING s 1-#4 GND, AWG THWN CU IN 2"C EXISTING 3-#4/0, GND, • G THWN CU IN 2"C =1 r•= MAIN FUSE rr 1000A 00 ME Fgvz M i t 6 architect 'ARCHITECT INC. i • ' D :r: t RRM 126 S. FEDERAL SUITE # 202 DANIA BEACH, FLORDA 33004 (954) 922-6551 .. •Ltd• •• « «. WEB: wwwrosensteinarddecLeom 1 ♦ AROOI&&74 1 ♦ &V78 r r -LVLJ COPYIRIC4-IT 0 2010 NOINMER170 j �TNN Af?j�-C;T, INC, TO MAIN IN MAIN ALL RIC*4TS RESERVE0. 1146 00=11ENT EXISTING > ELECTRICAL ROOM 3 SETS OF DESIGNED 4-#400 KCMIL, 1-#210 AWG GND CU THWN IN 4"NMC AS DRAWN AS CHECKED TEH HEREBY CERTIFY THAT PLANS WHEREPREPARED MY SUPERVISION, BEST OF r COMPLY APPLICABLE elton + leniz • U IT E C T 0 S A S • C IA .0 RUT •a r VITACURA MOUND N.T.S. NOTES: 1. WITHIN 30 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER AS PER FBC 13- 413.1.ABC.2.1. 2. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER AS PER FBC 13- 413.1.ABC.2.2. OVERRIDE TIME SHALL BE SET AT 30 MINUTES MAX. THE BEST OF MY KNOWLEDGE, r SPECIFICATIONS SUBMITTE) . COMPLY REWITH • PROVISIONS PLICABLE BUILDING r DRAWING IS THE SOLE PROPERTY .NZ ENGINEERING INC.' AND IS AN INSTRUMENT RO OF PDUCED IN WHOLE OR IN PART WITHOUT THE EXPRESS WRITTEN PERMISS] HENZ ENGINEERING INC. 1, THOMAS E. HENZ, P.E. #34261, CERTIFY THAT I CURRENTLY HOLD AN ACTIVE LICENSE IN THE STATE OF FLORIDA AND I AM COMPETENT THROUGH EDUCATION OR EXPERIENCE TO PROVIDE ENGINEERING SERVICES IN THE ELECTRICAL DISCIPLINE CONTAINED IN THIS PLAN. I FURTHER CERTIFY THAT THIS PLAN WAS PREPARED BY ME OR UNDER MY RESPONSIBLE CHARGE AS DEFINED IN CHAPTER 61615- 18.001 F.A.C. MOREOVER I CERTIFY THAT THE COMPANY OFFERING THE ENGINEERING SERVICES, 'HENZ ENGINEERING INC', HOLDS AN ACTIVE CERTIFICATE OF AUTHORIZATION #3880 TO PROVIDE THE ENGINEERING SERVICE. WARNING! �1,,. ot• , ®, N(1Z EC1G1f1E�If1G, I�1C. MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND ` '` 2320 NE 9th Street, Suite 200 TH,b LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL C COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAL G •T Fort Lauderdale, Florida 33304 REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE P ESSIONA�EIGGE1 g {fj{p.347', ` .; T 954,523.4933 PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS, ° ,STATF�gFA &I yd F 954.523,5052 CHANGES TO EQUIPMENT AND /OR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING : -tD� ��ff f www.henz.com PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS. DATS" • • • . • .1,c ` PROJECT Na ~; 10148.00 r comm. DATE 2010-41B 12-20-2010 5701 SUNSET D SUITE Bm10 RENOVATION I SOUTH t FLORIDA � w, � wv-© ,