11-05-002POWER LEGEND
SYMBOL
DESCRIPTION
EXISTING CONNECTION TO REMAIN
NEW CONNECTION
E
EXISTING CEILING MOUNTED DUPLEX RECEPTACLE
�E
EXISTING DUPLEX RECEPTACLE MOUNTED TO CALEIDOSCOPE
GRID SYSTEM.
EXISTING QUAD RECEPTACLE MOUNTED TO CALEIDOSCOPE
E
GRID SYSTEM.
NEW QUAD RECEPTACLE, 15A, MOUNTED TO CALEIDOSCOPE
GRID SYSTEM. FIELD COORDINATE EXACT LOCATION WITH
NEW
CALEIDOSCOPE GRID SYSTEM MANUFACTURER.
JUNCTION BOX (4X4" GALVANIZED STEEL, 18 ",U.N.D)
PANELBOARD ( +60" A.F.F O.0 OF PNL, U.N.D)
RASE ' —DASHED LINE DENOTES BRANCH CKT
NEUTRAL --- SOLID LINE DENOTES HOMERUN
'"-CIRCUIT NUMBER
ISOLATED GND.
3
FUSE SIZE _ �.-. WIRE IN FREE AIR SUPPORTED
60A
AME SIZE TO BLDG. STRUCTURE
NUMBER OF POLES
NOTES
1. NOT ALL SYMBOLS MAY APPEAR ON PLANS
2 IF THERE IS NO DESIGNATION NEXT TO FIXTURE, THEN
ASSUME IT IS A NEW FIXTURE. IF NOT EXISTING, LOCATE
IT AS SHOWN ON PLANS
DESIGNATION / DESCRIPTION
+84° DENOTES HEIGHT ABOVE TR TAMPER RESISTANT
FINISHED FLOOR LIND UNLESS NOTED DIFFERENTLY
AFCI ARC FAULT CIRCUIT INTERRUPT N/L NIGHT LIGHT
GFCI GROUND FAULT CIRCUIT INTERRUPT T/S TIME SWITCH
WP WEATHER PROOF ENCLOSURE PC PHOTO CELL
IG ISOLATED GROUND LC LIGHTING CONTACTOR
N NEW FIXTURE MWC MINIMUM WORK CLEARANCE
R RELOCATED FIXTURE OCR OVER CURRENT PROTECTION
E INDICATES AN EXISTING OC ON CENTER
FIXTURE TO REMAIN EN EXISTING LOCATION
T/L TWIST LOCK WITH NEW DEVICE
Fil
8, -g„
8> 9„
C
"PD 207 VISUA ___ -IT I I I I I CALEIDOSCOPE
7E"7,mn 6 —GRID SYSTEM
NEW PANEL 'LF'
L 2ND FLOOR
ELECTRICAL PLAN
teE ❑
OFFICE
2Q9
SCALE. 1/8" = 1' -0"
NOTES:
°' 1. DISCONNECT EXISTING HOME RUN FROM PANEL 'LE' AND RECONNECT TO PANEL
CORR 'LF' AS SHOWN. EXTEND EXISTING CIRCUIT TO PANEL 'LF' AS REQUIRED.
2. PROVIDE W CIRCUIT AS SHOWN.
3. CONNECT TO EXISTING CRCUTI WITH 3#12-1/2-C AS SHOWN.
rml
w
m
WARNING!
MECHANICAL EQUIPMENT ORDERED AND DELIVERED TO THE CONSTRUCTION SITE WITH THE WRONG
ELECTRICAL CHARACTERISTICS IS A MAJOR SOURCE OF CONSTRUCTION DELAYS, EXTRA COSTS AND
LITIGATION. THE CONTRACTOR IS HEREBY NOTIFIED THAT IT IS THEIR RESPONSIBILITY FOR FINAL
COORDINATION BETWEEN TRADES TO GUARANTEE THAT ALL EQUIPMENT HAS THE CORRECT ELECTRICAI
REQUIREMENTS FOR THE ELECTRICAL DESIGN. THE ENGINEERS' REVIEW OF SHOP DRAWINGS IS FOR THE
PURPOSE OF ATTEMPTING TO HELP THE CONTRACTOR CONFORM TO PLANS AND SPECIFICATIONS.
CHANGES TO EQUIPMENT ANDIOR CHARACTERISTICS CANNOT BE MADE THROUGH THE SHOP DRAWING
PROCESS. CHANGES TO EQUIPMENT SPECIFICATIONS CAN ONLY BE MADE THROUGH THE ISSUANCE OF
REVISED SIGNED AND SEALED PLANS AND SPECIFICATIONS.
fO THE BEST OF • r
HEREWITH COMPLY r PROVISIONS OF
APPLICABLE BUILDING rr ES. THIS DRAWING IS THE SOLE PROPERTY O
HENZ ENGINEERING INC.' AND IS AN INSTRUMENT OF SERVICE NOT • BE
'�EPRODUCED IN WHOLE OR IN PART WITHOUT
OF HENZ ENGINEERING INC.
• r- ! � r •r !
.�i, • r
i
KH U
i
2320 NE 9th Street, Suite 200
Fort Lauderdale, • •i 33304
s • c .. T 954.523.4933
954.523.5052
• ... • ROSENSTEI
126 S. FEDERAL
SUITE # i
DANIA BEACH, FLORDA 33004
PH: (954) 922-6551
FAX: (954) 922-7388
���� alb • iisl 1 - I � •'la ' ri 11
ST,4TE REG. NO. AR001roro74
NATL. REC-s. NO. &9178
- zip i' v— ;-
.— W. . c - li - :.. .��.
HEREBY
WHERE PREPARED ` OR UNDER
MY SUPERVISION, D TO THE : •
OF O i
APPLICABLE CODES.
%frorlImNal"Im"
A R Q U IT E C T 0 S A S 0 C I A D 0 S
RUT :76.575.840 -8
AURELIO GONZALEZ 3330
VITACU RA
R E V I S I O N S
comm. !'-
2010-41B 12-20-2011
i 4
SOUTH MIAMI
FLORIDA, 33143
FLOOR
ELECTRICAL
i
�o�